Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-02-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-02-2026 |
| 2 | 22-01-2026 | Corrigendum1 | Financial Bid | 04-02-2026 |
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each and removing from site, complete all as specified and directed. |
| 2 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but not exc. 4 Sqm each and removing from site, complete all as specified and directed. |
| 3 | Pressed steel frames of size 105x60mm for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 25x3mm flat iron 230mm long hold fast etc, complete all as specified and directed. |
| 4 | Pressed steel frames of size 125x60mm for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 25x3mm flat iron 230mm long hold fast etc, complete all as specified and directed. |
| 5 | 35mm thick flush shutters, solid core construction with block board core and plywood face panels commercial type on both sides, complete all as specified and directed by Engr-In-Charge. |
| 6 | Factory made 2nd class hard wood (Sal) glazed and Skelton door shutters 35mm thick open rebated and prepared to receive glass gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass or gauge etc., size of members of shutter as specified in clause 8.24 (a) of part-I, fitted to chowkats, complete all as specified and directed. |
| 7 | Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges shall be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 180 of MES SSR 2020 Part-II, complete all as specified and directed. |
| 8 | Factory made fully glazed (frosted/ground/obscured) / fully gauged PVC window/ ventilator shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5 mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement,suppling & fixing in the frame at site, as per specifications and drawing complete all as as specified and directed. |
| 9 | Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion and packing filling of chowkhats in PCC M-15, type B-0, 04 nos of each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf.(iii) MS tower bolt 150mm long - 2 No per leaf. (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) Fabrication & fixing arrangement as per drg No. CEPZ/ TD 06/07. Note:- (i) Above referred drawing has not been made part of tender. The same can be seen in the office of GE during working hours on any working day. |
| 10 | M&L WPC (Wood Polymer Composit) Double Prelam Door Frame (Chowkhat) of Size 120mm x 50mm with a wall thickness of 5mm(+/- 0.25), made out of extruded 5mm(=0.25) mm thick PVC Sheet of Density 600kg/cbm manufactured y an ISO 9001-2015 certified company and by joining 3 Nos heat moulded PVC Sections. The high section of size 35 x35 mm shall be maid from plain colour PVC sheet of 5mm(=/- 0.25 mm) thickness. The inside section will be covered with 5mm thick PVC sheet\"C\" shape covering section of size 120mm x 50mm. At centretop position 5mm(+0.25mm) thick 50 x50 x50 mm pattam section should be pasted with solvent cemen adhesive to make double pattam of frame. The frame shall be mitre cut at two corners & joined with 4 nos of 150mm long \"L\" brackets of 19 x 19 mm MS square, Tube or fusion heat welding process. The two vertical door frames are to be reinforced with 25 x 25 mm MS square Tube of 19 gauge throughout the frame. The Door Frame shall be fixed to the wall using 8/100mm fischer screws. A minimum of 4 nos of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member etc. complete as per manufacture\"s specification & direction of engineer-in charge. |
| 11 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of solid core single Leaf Flush Door of 25mm thickness, lipped with 15mm (5mm x 3) thick x 30 mm width on one stiles and top rails & 10mm (5mm x 2) thick x 30 mm width on the other stiles & bottom rails. The inner panel Laminated with 2mm thick termite proof, water proof & fire resistant moulded PVC sheet with 2,4,6 raised panel design in different plain &/or prelam colors on one side after routing the mouldd design on flush door & 2mm plain and/or prelam PVC sheet on other side using rubber based adhesive on flush door & solvent cement adhesive on the lipping etc. complete as per direction of Engineer-in-charge, manufacture\"s specification and drawing. |
| 12 | Sheet glass 3mm thick ordinary quality and glazingwith oil putty/wooden beads in squares, not exc. 0.5sqm in each pane, complete all as specified and directed. |
| 13 | 3mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 Sqm in each pane, complete all as specified. |
| 14 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks of glavanised wire staple fixed with stainless steel wire staples, fixed, complete all as specified and directed. |
| 15 | Applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surfaces of any description, exc. 10cm width or girth including preparation of surfaces, complete all as specified and directed. |
| 16 | Butt hinges (ISI marked), medium weight, cold rolled, mild steel 100mm long, complete all as specified and directed. |
| 17 | Extruded aluminium alloy handles (ISI marked, fabricated type, anodised, of size 150mm, complete all as specified and directed. |
| 18 | Aluminium anodised, (ISI marked), barrel tower bolts of extruded section, length of bolt 150mm, fixed, complete all as specified and directed. |
| 19 | Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 250mm with lipping frame to match, complete all as specified and directed. |
| 20 | Ordinary rat tail rod pattern springs 300mm, including roller and roller plate complete all as specified and directed. |
| 21 | S&F for Steel locking bolts with mild steel electrogalvanised plate and bright bolt not less than 10mm dia 100mm size all as specified. |
| 22 | Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed. |
| 23 | 2nd classhard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as as specified and directed. |
| 24 | Prelaminated particle board 18/19mm thick interior grade prelaminated both side with decorative choice lamination and other side balancing white lamination and fixed with screws to timber frame work as on wall panelling cup boards shutters/shelves (sliding or fixed), complete all as specified and directed. |
| 25 | Extra over rates of 18/19mm thick block board or veneered particle board/ prelaminated board for external teak wood lipping, 6mm thick fixed with nails, complete all as specified and directed. |
| 26 | Continuous (piano) hinges, mild steel, bright finish or electrogalvanised Width of flaps (when open) in 40mm, complete all as specified and directed. |
| 27 | Extruded aluminium alloy handles (ISI marked), fabricated type, anodised, of size 100mm, complete all as specified and directed. |
| 28 | Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified and directed. |
| 29 | Dismantling timber scantlings 40 sqcm and over in section, in any position, unframed work, complete all as specified and directed |
| 30 | Dismantling boarding, any discription fixed in any postion with nails, complete all as specified and directed |
| 31 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. |
| 32 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. |
| 33 | Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. |
| 34 | Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. |
| 35 | Non skid, Premium class Igrade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, as in skirting, dado etc . set and jointed in neat cement slurry and includingincluding 10mm thick rendering in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed. including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed. |
| 36 | Glazed coloured tiles of size 350mmx250mm / 450x350/ 300mm x 450 x7 to 8mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry and pointed with coloured cement to match and including 10mm thick plastering in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 37 | Machine cut kota stone slab flooring 18-20mm thick of size not less than 550 mm X 550mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC sub base, complete all as specified and directed. |
| 38 | Plain cement concrete M-15, nominal mix, type B-0, using 12.5mm graded mechanically crushed stone aggregate as inflooring, 25mm thick, surface finished even and rough to receive top finish or chamfering of RCC chajja with proper slope to drain off storm water surface, complete all as specified and directed. |
| 39 | Plain cement concrete M-10, nominal mix, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5cm deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), complete all as specified and directed. Note:- The unit rate include for use of form work (straight or curved). |
| 40 | Demolition of cement concrete (un-reinforced) of any description and any position not otherwise specifically provided for, including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. |
| 41 | Plain cement concrete 1:5:10, nominal mix, type E-2, using 40mm graded mechanically crushed stone aggregate as in sunken floors, filling and mass concrete, complete all as specified and directed. |
| 42 | Water proofing treatment of sunken floor using SHALIURETHANE- BTD OF STP MAKE OR EQUIVALENT as approved by GE, high solid content single component water based liquid applied elastomeric water proofing membrane as ASTMC 836 and ASTMD 6083, thickness of the membrane shall be 1.5mm, having solid content of more than 80% elongation of 500+(-) 50%, laid over reinforcing layer on non woven geo-textile mesh of 40/50, 50 gms, including applying self primer coat by diluting with 1:1 ratio @ 0.4 kg per sqm and surface including 10 mm thick 1:3 plaster including cleaning of existing treatment complete all as specified and directed |
| 43 | Rendering cement plaster 10mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers ( 5mm thick first layers and 5mm thick 2nd layer) mixed with WPC @ 3% weight of cement on fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and as directed by Engr-In-Charge. |
| 44 | Plain cement concrete M-15, nominal mix, type B-1, using 20mm graded mechanically crushed stone aggregate as in sunken floor, 25mm thick, surface finished even and fair, complete all as specified and directed. |
| 45 | Mild steel galvanized iron water tubing 32mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. as in spout of sunken floor, including taking down old pipe, complete, all as specified and directed. |
| 46 | 75mm thick Plain cement concrete M-10 nominal mix, C-2, using 40mm graded mechanically crushed stone aggregate as in sub base flooring, complete all as specified and directed. |
| 47 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 48 | Dismantling stone slabs and tiles of any description or thickness, laid bedded and pointed in any mortar in floors, aprons etc.including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. |
| 49 | Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for, including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. |
| 50 | TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 51 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping)etc. for fair finished flat surfaces of concrete, complete all as specified and directed. |
| 52 | Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, including formwork, complete all as specified and directed. |
| 53 | Marble 18 to 20mm thick, green marble, (table rubbed and polished and moulding of outer edges) as in kitchen cooking platform /shelf and verticle surfaces duly machine cut in skirting /dado and like laid over and including 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade green marble type, complete all as specified and directed. |
| 54 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 55 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 56 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 57 | Dismantling and breaking up PVC drain pipes 75/110mm dia, fixed to walls, laid in floors or in trenches and removal of demolished materials from the site, complete all as specified and directed. |
| 58 | PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75mm, fixed, complete all as specified and directed. |
| 59 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors, trenches, of bore 110mm, complete all as specified and directed. |
| 60 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, in floors, trenches, of bore 75mm, complete all as specified and directed. |
| 61 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 75mm, complete all as specified and directed. |
| 62 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 110mm, complete all as specified and directed. |
| 63 | PVC (SWR) junction single, (Single T) equal or unequal, 75mm bore, provided with oval access door, fixed in repair, complete all as specified and directed. |
| 64 | PVC (SWR) junction single, (Single T) equal or unequal, 110mm bore, provided with oval access door, fixed in repair, complete all as specified and directed. |
| 65 | PVC (SWR) bends any radius, 110mm bore jointed with solvent cement (fitted with or without oval access door), fixed in repair, complete all as specified and directed. |
| 66 | PVC (SWR) bends any radius, 75mm bore jointed with solvent cement (fitted with or without oval access door), fixed in repair, complete all as specified and directed. |
| 67 | PVC (SWR) vent cowl 110mm bore fixed in repair, complete all as specified and directed |
| 68 | Rotational moulded polyethylene water storage tank 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including PVC float ball valve 20mm dia epoxy coated aluminium rod with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, complete including taking down old tank and removng to store all as specified and directed. |
| 69 | Sink with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connectingunion to pipe, including 40mm dia waste pipe & CP waste coupling, overall size 915mm x 460mm bowl size 405mm x 355mm x 178 mm, Cat No Blue Star SSSB-52 Silver Shine oror equivalent in makes specified in Appendix \"C\"fixed in repair complete all as specified and directed. |
| 70 | Soap dish, chromium plated, fixed to plugs with chromium plated, brass screws, fixed in repair, complete all as specified and directed. |
| 71 | Sheet glass shelf assembly 55cm long consisting of 5.50mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, selected quality as approved by GE, fixed in repair, complete all as specified and directed. |
| 72 | Chromium plated brass shower rose, fancy type (as approved by GE/Engr-In-Charge), 125mm size with shower arm, chromium plated, 195mm longh with bend of 45 degree with flange suitable for 15mm bore pipe with or without swivel joint fixed to pipe, fixed in repair, complete all as specified. |
| 73 | Angle/stop valve, cast copper alloy, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle,screwed both ends for 15mm bore iron pipe or for unions and fixed in repair, complete all as specified and directed. Make : Make:Cat. No.: F360006 of \"HINDWARE\" orF1016201CG of \"CERA\" orCat No. 8110 of \"PRAYAG\" orCat No. TQT-526N of \"ESSCO\". or equivalent in makes specified in Appendix \"C\" |
| 74 | Stop valve, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed in repairs, complete all as specified and directed. Make:Cat. No.: F360007 of \"HINDWARE\" orF2014361 of \"CERA\" orCat No. 8118/8120 of \"PRAYAG\" orCat No. TQT-514A of \"ESSCO\". or equivalent in makes specified in Appendix \"C\" |
| 75 | Bib taps, fancy type 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, chromium plated screwed for iron pipe or for brass ferrule and fixed in repairs, complete all as specified and directed.Make:Cat. No.: F360004 of \"HINDWARE\" orF2005152 of \"CERA\" orCat No. 8108 of \"PRAYAG\" orCat No. TQT-512 of \"ESSCO\". or equivalent in makes specified in Appendix \"C\" |
| 76 | Supply and fixed in repair PVC valveless, crystal white, syphonic action type flushing cistern 10 litres capacity low level with inlet, ball valve, float and handlewith brackets including 32mm dia PVC long bend flush pipe 90cm long snd 15mm dia PVC connection 600mm with CP brass coupling nuts and PVC washers at both ends, fixed, complete all as specified and directed. ake:Cat. No.:B1010105 of \"CERA\" orCat No. 504 of \"PRAYAG\"or equivalent in makes specified in Appendix \"C\" |
| 77 | Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, snow white, with Cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate and making connection to trap complete all as specified, fixed in repair, complete all as specified and directed. Cat. No.: CABLE 3020105of \"CERA\" or Cat. No.: 20004 of \"HINDWARE\" orCat No. 4053/4054/4056 of \"PRAYAG\" orCat No. ECS-WHT-453 of \"ESSCO\". or equivalent in makes specified in Appendix \"C\" equivalent in makes specified in Appendix \"C\"\" |
| 78 | Brass Chromium Plated, Tubular towel rail, 20mm dia, D type, 60cm long between flanges, with brackets, fixed with chromium plated screws, fixed in repair, complete all as specified. |
| 79 | Wash hand basins, Vitreous China (Table top basin) of size 550mm x 400mm oval shapecoloured, fixed in granite counter by making suitable holes, new brackets with and including cutting for and pinning on ends of brackets, fixed, 450mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, completeall as specified. as per Cat No : ECS-WHT-841 of ESSCO, Cat No 4655 of \"PRAYAG\"starwhite Cat. No.: 10055 of \"HINDWARE\" or Cat. No. S2040161 of \"CERA\" as directed by Engr-in-charge, |
| 80 | Looking mirror 600mmx450mm bevelled edgeof selected quality with 6mm thick polished glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers fixed, complete all as specified and directed. |
| 81 | Brass CP sink mixer with 165mm long swivel spout, connecting legs and wsll falanges for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed. Make:Cat. No.: F1020501of \"CERA\" or equivalent in makes specified in Appendix \"C\"\". |
| 82 | Chromium plated centre hole Mixer for Wash hand basin for mixing hot or cold water with 450mm braided connection pipe (without pop-up) screwed for iron pipe, complete all as specified and directed.Make:Cat. No.: F12002461 of \"CERA\" or equivalent in makes specified in Appendix \"C\". |
| 83 | Brass chromium plated Wall mixer with provision of long bend pipe with connecting legs and wall flanges screwed down for iron pipe and fixed, complete all as specified and directed. Make:Cat. No.: F2002511 of \"CERA\" orequivalent in makes specified in Appendix \"C\"\". |
| 84 | Polyethlene and unplastcised PVC pipe, 32mm dia Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm all as specified and directed. |
| 85 | Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. |
| 86 | Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers on fair faces of brick or stone walls finished even and smooth without using extra cement, mixed with WPC, complete all as specified and directed.Note : Supply only Water proofing compound shall be measured and paid for seperately. |
| 87 | Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) on internal fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 88 | Material and Labour for taking down existing plaster including raking out joints for waterproofing of exterior wallsand applying two coats of acrylic polymer modified high performance coating (Smartcare Ultra Block 2k). The treatment shall be done from ground level and including 15mm thick cement plaster in CM 1:4 finished even and smooth all as directed. Make: \"ASIAN PAINTS/BERGER/NEROLAC\" |
| 89 | Rendering cement plaster 10mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) on ceiling surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 90 | Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over & including 2mm thick wall care putty, complete all as specified and directed. |
| 91 | Preparation of old treated plastered surface of wall by complete removal of existing treatment and applying two coats of oil bound distemper over & including 2mm thick wall care putty, complete all as specified and directed. |
| 92 | Preparation of new plastered or unplastered surfaces of wall to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. |
| 93 | Preparation of old plastered or unplastered surfaces of wall including complete removal of existing treatment and finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. |
| 94 | Preparation of new plastered surfaces of ceiling with 2mm thick wall care putty and applying one coat of oil bound distemper, complete all as specified and directed. |
| 95 | Preparation of old plastered surfaces of ceiling including complete removal of exising treatment and applying one coat of oil bound distemper, complete all as specified and directed. |
| 96 | Taking down cement plaster/decayed concrete from RCC roof projections/upward parapet walls/down facia/soffits and fins of RCC chajjas/beams/columns/balconies etc. Supply and fixing by means of nailing wire netting of galvanised wire 1.40mm dia and mesh size 20mm and brushing neat cement slury with 3.00 Kg of cement/sqm and M&L for 20mm thick cement rendering in two layers of 10mm each (top/final layer shall be rendered after final setting of under layer) in CM 1:3 on concrete surfaces including scaffolding at a height upto 7.00 mtrs ect, complete all as specified and directed. |
| 97 | Taking up or down 15mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. |
| 98 | Taking up or down 20mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. |
| 99 | Taking up or down 25 mm to 32mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. |
| 100 | Supplying and laying of CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 101 | Supplying and laying of CPVC pipes 32mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 102 | Tank Adaptor CPVC pipes of 32mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. |
| 103 | Female Brass Threaded Adaptor (FTA/ FBTA) for CPVC pipes of 20mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. |
| 104 | Supply only intergal water proofing compound, complete all as specified and directed. |
| 105 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls, complete all as specified and directed. |
| 106 | Plain cement concrete M-15, nominal mix, B-1 using 20mm graded mechanically crushed stone aggregate as in lintels upto 1.50 metre clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as specified and directed.Note :- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately. |
| 107 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars, including removal of debris to a distance exc 1.5 km but n.exc 2 Km, complete all as specified and directed. |
| 108 | Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 109 | Brick work with old sizefly ash bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 110 | S&F in repair 25mm dia powder coated mild steel, chromium plated curtain rod including brackets, complete all as specified and directed. |
| 111 | Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe.290 Gde E-165, steel work, complete all as specified and directed. |
| 112 | Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. |
| 113 | Steel plate rack of size 600mmx750mmx250mm made of stainless steel 1.00mm thick fixed with plugs, washers and steel screws including fixed inwall with screws ands PVCsleeve of required or fixing arrangement complete all as specified |
| 114 | Preparation of old painted steel surfaces of any description and otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 115 | Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm, fixed in repair, complete all as specified and directed. |
| 116 | Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5m in depth and getting out, complete all as specified and diercted. |
| 117 | Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point, complete all as specified and directed. |
| 118 | Plain cement concrete 1:3:6, type C-1 using 20mm graded mechanically crushed stone aggregate as in surface channel and drains, complete all as specified and directed. |
| 119 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick each layer of soil, complete all as specified and directed. |
| 120 | Demolition and breaking up drain pipes (Salt glazed stone ware, AC or RCC pipes) 150 mm dia and removal of demolished materials from the site as directed |
| 121 | Reinforced concrete pipes, class NP2, laid and jointed complete with collars,bore of pipe 150mm, all as specified. |
| 122 | Plain cement concrete 1:4:8 type D-2 nominal mix using 40mm graded aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for internal dia of pipe 150 mm, all as specified. |
| 123 | Taking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including switches, sockets, holders, (batten or pendent type), ceiling rose, switch board, bell/buzzer, bell push, and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes, complete all as specified and directed. |
| 124 | Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surfaces, complete all as specified and directed. |
| 125 | M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and includingconcealed PVC conduit(ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable sizeincluding concealedMS pressed steel (Modular sunken box) terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and Modular cover plate as top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/Exhaust fan point controlled by one switch, complete all as specified and directed. Note : i)Wiring Colour code i.e. Red/Yellow/Bluefor Phase, Black for neutral and Green for earth shall be maintained.ii) Rate of cutting chases, cement plaster, white wash and making surface good as existing surface included in quoted rate.iii) Point wiring is considered for Modular Switches and sockets. Rate of Metallic Sunken box and modular sheet cover plate and other connected accessories required for modular point wiring included in quoted rate.iv) Rate of modular switch and sockets will be paid seperately under relevant item. |
| 126 | All as per serial item No \"126\" above, but for one 3 pin 5 Amps socket outlet on the same board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. |
| 127 | All as per serial item No \"125\" above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. |
| 128 | All as per serial item No \"125\" above, but for one light point controlled by two way switches, complete all as specified and directed. |
| 129 | All as per serial item No \"125\" above, but for 5 pin 15 amps socket out let on independentwith 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed. |
| 130 | S & F for modular switch 6A one way, single module, complete all as specified and directed. |
| 131 | S & F for modular switch 16A one way, single module, complete all as specified and directed. |
| 132 | S & F for modular socket for 6A 2/3 pin combined, 2 module, complete all as specified and directed. |
| 133 | S & F for modular socket for 6A/16A, 5 pin combined, 2 module, complete all as specified and directed. |
| 134 | S & F for modular bell push 6A, single module, complete all as specified and directed. |
| 135 | S & F for modular Bell/buzzer, Ding Dong with indicator 6 Amp, one module, complete all as specified and directed. |
| 136 | Supply and Fixing sheet metal enclosure with socket plugtop with MCB of a two pin and earth plug and a socket complete with one double pole MCB of 20 Amps rated, complete all as specified and directed. |
| 137 | S & F for modular switch two way 6A, single module, complete all as specified and directed. |
| 138 | M & L for ceiling rose 65 x 50mm three terminals, fixed, complete all as specified and directed. |
| 139 | Sheet metal enclosures factory made flush fixed for DBs when MCBs to be used, single pole and neutral (double Door powder coated), 8 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed. |
| 140 | Supply and fix distribution board iron clad TPN DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface, complete all as specified and directed. |
| 141 | S & F for MCB SP 6 to 40 amps 240 Volt,10 KA, \"B\" series, complete all as specified and diercted. |
| 142 | S & F for MCB SPN 32 amps 240 Volt, 10 KA, \"B\" series, complete all as specified and diercted. |
| 143 | S & F MCB,TPN,63 Amp capacity, 415 V, 10 KA, B series including taking down old MCB 4 Pole, complete all as specified and directed.Note: The connection to the MCBs shall be done through thimble/ lugs and no direct wire shall be connected to MCBs. |
| 144 | M & L for submain wiring in and including PVC conduit 1.8 mm thick, 20 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 6 sqmm (FRLS) and one run of PVC insulated, unsheathed multistranded copper conductor 6 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM).Note: (a) Insulation test of point wiring to be carried out on completion of work.(b) Proper colour coding is to be maintained. (Ph-Red, N-Black,Earth- Green)(c) Two runs of single core cable with one run of earth cable and suitable size of conduit shall be measured as one RM.(d) Cutting chases for sub main wiring concealed PVC rigid conduit shall be deemed to be included in the quoted rate of item. |
| 145 | S&F in repair wall mounted LED tube light fitting integral type 1x 10 W, 230V,connector block etc completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light, complete all as specified and directed. |
| 146 | S&F in repair wall mounted LED tube light fitting integral type 1x 20 W, 230V,connector block etc completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light, complete all as specified and directed. |
| 147 | S&F LED tube light fitting inverter type 1x 20 W, 220V, decorative type with driver, ultra slim square profile LED lighting fixture, environment friendly, energy efficient ready to use completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed. |
| 148 | Supply and installing of the electric water storage heater (Geyser) of ABS body type of 25 litre capacity with rated power 2 KW, BEE, 5 star rated, vertical type, thermally insulated Mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostate, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm dia bore GI hexagonal adopters/Nuts on both side of inlet (cold water supply) and outlet (hot water supply) and including provision of wall mounting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation, complete all as specified and as directed by Engr-In-Charge. |
| 149 | Supply and hanging ceiling fan including fan regulator step flush type speed controllorwith complete fixing arrengement of size 1200 mm sweep blade minimum air delivery 210 CFM with service value 6.00 BEE, five star rated (BLDC) including provision of copper multi stranded PVC insulated 1100 volts grade three core flexible cable for main connection with existing ceiling rose at point wiring complete all as specified and directed by Engr-in-Charge. |
| 150 | Supply and fixing for AC exhaust fans, Steel body, single phase, 230 volts, 250 mm sweep including grouting the ragged bolts in wall, fixing the frame on the exhaust side and connecting up with PVC insulated three core 1.50 sqmm copper cablefrom ceiling rose to exhaust fan, complete all as specified and diercted. |
| 151 | Endura Pearl 35 Watt new generation energy saving and environmental friendly long life LED Bldg security light made up of pressure die case aluminium housing with high power LED as lighting source an lens enbedded PC cover having TOP opening seperate toughted glass/verminproof driver compartment, SPDs with IP66 protenction and impact resistancee of IK07 connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of suitable size, Make : Havells HSN Code-8537 or equivalent in Crompton/ Wipro/ Bajaj/Philips. |
| 152 | Taking down AC Meter, checking and repairing at site by repair/replacement of contacts, terminals, indicators, glass cover, plate screws, electronic circuits etc and refixing in same position complete all as specified. |
| 153 | Supply, installation of meter box suitable for installation of MCCB as incomer, 04 Nos Meters, 03 Nos MCBs SPN 40 Amps, meter box double door type, fixed type wall mountedincluding locking arrangementfactory fabricated weather and vermin proofmade out of 2.00 mm thick MS Sheet CRCA Sheetwith front opening doors, handle type locking arrangement suitable to accomodate and including following accessories including taking down/out DB,:INCOMING:(a) MCCB FOUR POLE 100 amps, AC,415 VOLTS16 KA=01 No (b) Indicating lamp set (RYB) - 03 NosOUTGOING:(c) MCB SPN 40 amps = 03 Nos (for outgoings) complete all as specified and diercted.(d) Refixing of existing electric metersNote :- (i) TInternal wiring of panel shall be done with 6 Sqmm PVC insulated, unsheathed multistranded copper conductor using appropriate size thimbles.(ii) Bidders may visit the site to see the space in the bldg for installation of panel box before submitting priced bid.(iii)All the vacant holes of the box shall be provided with blank plates of appropriate size. (iv) Cutting chasing shall be part of job at no extra cost. |
| 154 | Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 35 sqmm x 3.5 core, 1100 Volts grade, complete all as specified and diercted. |
| 155 | Sand cushioning to under ground cables, 8cm thick layer before laying and testing the cable and 15cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I, complete all as specified and directed by Engr-in-Charge. |
| 156 | Sub class \"B\" bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed. |
| 157 | Mild steel galvanised light grade 50mm dia tubing with all fitting; laid in trenches, across road or on pole, complete all as specified and directed. |
| 158 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.50m below ground level, connecting to galvanised iron wire 4.00mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.NOTE :- Item of earthing includes the cost of 7.5 m long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail