| 1 | SCHEDULE A BOQ |
| 2 | M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as specified and as directed. |
| 3 | M & L Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil and removing excavated soil outside MD land complete all as specified and as directed |
| 4 | M & L Hardcore (broken stone or boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed |
| 5 | M & L PCC 1:3:6, Type C-2 using 40mm graded aggregate in foundations, filling and mass concrete etc complete all as specified and as directed |
| 6 | M&L for Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete all as specified and as directed |
| 7 | M&L for providing Cement concrete 100mm thick, type D-2, 1:4:8 (40mm gradedaggregate) under floors complete all as specified and as directed |
| 8 | M&L for providing Cement concrete 25mm thick, type B-0, 1:2:4 (12.5mm graded aggregate) under floors complete all as specified and as directed |
| 9 | M&L for Damp proof course 40mm thick in cement concrete 1:2:4 type B-0 (using 12.5mm graded aggregate) mixed with WPC to horizontal or vertical surfaces including necessary formwork complete all as specified and as directed |
| 10 | M&L for Polythene sheet 150 micron over a coat of Polymerized bitumen @ 1.5 Kg/Sqm complete all as specified and as directed |
| 11 | M & L Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed inside the MoD land complete all as specified and as directed |
| 12 | M & L Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed |
| 13 | M & L for M25 RCC using 20mm graded aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed |
| 14 | M & L for M25 RCC using 20mm graded aggregate for Columns, pillars, piers, posts and struts complete all as specified and as directed |
| 15 | M & L for M25 RCC using 20mm graded aggregate for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed |
| 16 | M & L for M25 RCC using 20mm graded aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed |
| 17 | S&F for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat rough finished surfaces of concrete complete all as specified and as directed |
| 18 | S&F for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces concrete rectangular in shape complete all as specified and as directed |
| 19 | S&F for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces concrete complete all as specified and as directed |
| 20 | S&F for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces concrete complete all as specified and as directed |
| 21 | M&L Pre-cast cement concrete block masonary with solid blocks, exc. 10 cm in width type B-1 1:2:4 using 20mm graded stone aggregate and setting in mortar 1:4 straight or curved on plan exc 6m mean radius, complete all as specified and as directed |
| 22 | M&L for Cement concrete type C-1, 1:3:6 using 20mm graded aggregate as in plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 23 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed |
| 24 | M&Lplain cement concrete (1:1(1/2):3), type A-1 (using 20 mm graded mechanically crushed stone aggregates),as in post hole concrete filling, hardstanding (including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume)), etc. surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | M&L Providing precast cement concrete (PCC 1:2:4 type B-1) using 20mm graded stone aggregate inlandings, cover slabs (for man holes etc.) chullah hoods, chajjas,water troughs, mangers, shelves and similar articles with plain faces set in cement mortar CM 1:4 complete all as specified and as directed. |
| 26 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed. |
| 27 | M&L TMT bars 6-8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed. |
| 28 | M&L Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:4 in 2 coats (5 mm thick setting coat with WP compound/liquid as per manufacturer’s instructions over 10 mm thick backing coat) finished even and smooth without using extra cement complete all as specified and as directed (Water proofing compound shall be measured and paid seperately) |
| 29 | Supply only water proofing compound complete all as specified and as directed. |
| 30 | M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 31 | M&L Rendering 5 mm thick cement plaster on concrete surface in CM 1:4 finished even and smooth without using extra cement as in ceiling etc complete all as specified and as directed. |
| 32 | M&L Preparing new surfaces ofplastered wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed |
| 33 | M&L Preparing new surfaces ofplastered or unplasteredceilling and applying three coats of white wash complete all as specified and as directed |
| 34 | Providing and laying / fixing TPO (Thermoplastic Polyolefin) water proofing membrane of non-flammable waterproofing of roof which shall be a 1.5mm thick loose laid membrane using Fosroc Proofex ORG membrane, layers are overlapped to achieve a minimum weld of 110mm. Hot air welding can be either hand applied or by means of automatic machines and the roll\"s either end are overlapped with 110mm are in stagered positions and the membrane shall be laid over the layer of non-woven geotextile fiber (Minimum 200GSM). The separation layer provided to prevent the mechanical abrasion and cushioning between the Fosroc Proofex ORG membrane and the concrete substrate. The termination of Fosroc Proofex ORG by aluminium strop anchoring and sealant filling shall be as per manufacturer\"s specification. Water proofing membrane should be all weather proof and UV resistance. The TPO membrane shall have the following properties:(i)Thickness: 1.5mm(ii) Tensile Strength : >9 N/mm²(iii) Elongation at break : > 950% (ASTM D 412)(iv) Puncture resistance > 1000mm : Pass (EN 12691)(v) Water impermeability : Pass (EN 1298 & EN 12691)(vi) Tear Resistance : 470 N (EN 12310 - 1)(vii) Root Resistance : Pass Test - No Penetration(viii) Lap joint strength : Pass Test (EN 12317 & UEATc)Preparation of Surfaces: Surfaces should be free from cavities and projecting nibs. All surfaces shall be dry and free from frost, surface laitence and contamination. |
| 35 | Note for Water proofing treatment:(i) The work shall be carried out through authorized and qualified applicators of the following manufacturer\"s only. MOU to be submitted before commencement of work. Make:M/s FOSROC(ii) A performance guarantee certificate for 10 years shall be submitted by the contractor to the GE on completion of work as specified.(iii) The unit rate quoted is deemed to include taking down cables, wires, earthing strips, ac pipeline etc found on roof and refix the same at the original position after complete treatment of roofs.(iv) The unit rate quoted shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto any height from natural ground level.(iv) The unit rate quoted shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto any height from natural ground level.(vi) Necessary safety arrangement like safety belts, ropes, helmets, netting etc which are required for safety of working labour at height exc 3m to be provided by the contractor and the rate for this provision is deemed to be inclusive in the quoted rate. |
| 36 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft and loose soil complete all as specified and as directed |
| 37 | S&F 150mm dia uPVC pipes laid in trenches and jointed complete all as specified and as directed |
| 38 | M&L for Cement concrete bed in 1:3:6 type C-2to drain pipes including packing under, and haunching against the sides of 150mm bore of pipes after they are laid and tested complete all as specified and as directed |
| 39 | M&L Brickwork with fly ash bricks in one brick thick honey-comb walling, built in cement mortar 1:4 complete all as specified and as directed. |
| 40 | M&L for Loose filling of broken bricks of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed. |
| 41 | Providing and laying Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and colour pigment complete all as specified and as directed |
| 42 | S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.Note: Cutting holes, mortices, etc. chases in old concrete, brick or stone structures and making good after steel/iron work is fixed. The making good shall be done with a mix of mortar or concrete not leaner than cement mortar 1:2 or PCC 1:2:4 type B1 and to the satisfaction of Engineer-In-Charge. |
| 43 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed |
| 44 | M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 45 | M & L Providing 75mm thick plain cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in sub base etc complete all as specified and as directed. |
| 46 | M&L Preparing new surfaces ofplastered or unplastered wall and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and as directed |
| 47 | Excavating in post holes (or similar holes) each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding50m and making good surface as in hard / dense soil complete all as specified and as directed |
| 48 | S & F Steel work in tubular trusses/ post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240 complete all as specified and as directed |
| 49 | M&L MS Plates (Plain or chequered)channels (confirming to Fe 410 W Gde E-250 A quality),squarecutor notched (ordinaryand countersunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed |
| 50 | M&L for Joist, channel, angle, or tee sections, fixed independently(confirming to Fe 410 W Gde E-250 A quality), without connecting plates, etc. complete all as specified and as directed |
| 51 | S&F Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheetof any approved colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed |
| 52 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mmthick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 53 | M&L MS flat iron wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc. , and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed |
| 54 | M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm complete all as specified and directed |
| 55 | M&Lplain cement concrete (1:1(1/2):3), type A-1 (using 20 mm graded mechanically crushed stone aggregates),as in post hole concrete filling, hardstanding surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 56 | M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width type C-1 1:3:6 using 20mm graded stone aggregate and setting in mortar 1:6 straight or curved on plan exc 6m mean radius, built incement mortar 1:6 complete all as specified and as directed |
| 57 | M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 58 | M&L Preparing new surfaces ofplastered wall surface and applying two coats of oil bound distemper complete all as specified and as directed |
| 59 | Taking down Chowkats or frames with shuttersexceeding 1.5 Sq.m each but n exc 4 sq.m each with shutter (without taking off shutters from the frame)complete all as specified and as directed.Note for Item 1 to 5:- The quoted rate shallinclude the cost of scaffolding required for upto 15 Mtr high buildings |
| 60 | S&F in replacement of siemens wireless Fire Alarm Control Panel: Using wireless technology that is highly secure, the Automatic alarm grade 10 to 30 mA, Ac input power 230V, addressable 5 loop control panel no of addresses 505 upto 8 loop extended programble input output 12 nos long battery life and unmatched wireless robustness. A perfect solution for monitoring service providers who require high performance at a low cost. Suitable for large residential and small to mid-size business installations. Two-way communication eliminates lost alarms and unnecessary re-transmissions. Efficiently overcomes interference and jamming through multi-channel frequency all as specified and directed by Engr-in-Charge. |
| 61 | S&F in replacement of Siemens Wireless Smoke and Heat Detector: 24 Vdc, PVC white automatic, photo electric reliably sends early warnings in case of smoke or fire with a fully supervised, photoelectric smoke and heat detector. It alerts occupants of the room by activating the built-in 85db alarm buzzer and flashing LED light when smoke or temperature exceeding 57°C (135°F) are detected. At the same time, it transmits a coded signal to the control panel to activate the system siren, alerting the end user and/or central monitoring station to send on site assistance complete all as specified and directed by Engr-in-Charge. |
| 62 | S&F in replacement of Siemens Wireless Outdoor Siren: is a two-way wireless outdoor siren (IP55). It provides the perfect security solution for home owners with a Power Master system who are looking for an affordable and easy to install outdoor siren complete all as specified and directed by Engr-in-Charge |
| 63 | S&F in replacement of Siemens Loop Card: The new Loop Card is designed to fully comply with Vigilon range of panels. The increased power allows for up to sensor-sounder-strobes, managing up to 200 devices in total.Benefits Improved efficiency with 2 times more alarm power with no loss of standby Supports up to 100 S-Quad Sensor-Sounder-VADs it will design and update software to support new techonology to control panel and ddetector through zone card complete all as specified and directed by Engr-in-Charge |
| 64 | S&F in replacement of Manual Call Point: The call point is an addressable break glass manual call point which has a simple rotary decade switch at the rear of the unit for addressing. A specialist test key may be inserted into the bottom/upper of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.complete all as specified and directed by Engr-in-Charge |
| 65 | Supply and fix in replacement of RS 485 Communication module complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply and installation in replacementof Modbus TCP/IP interface module. Requires an RS485 card to be fitted in the control panel & MI-RJ-45 Cable complete all as specified and directed by Engineer-in-Charge |
| 67 | Supplying, drawing, connecting, testing & commissioning of 2 core, 1.5 Sqmm stranded copper conductor, PVC insulated PVC sheathed, aluminium myler tape shielded FRLS wire in draw through existing conduit complete all as specified and directed by Engineer-in-Charge |
| 68 | Supply and laying of 25/20mm Dia PVC conduits fixing on wall/roof/ceiling etc including concealed in wall and securing with proper saddle and making good disturbed surface and well finishing (For Fire Detection) all accessories complete all as specified and directed by Engineer-in-Charge. |
| 69 | S&F in replacement of HONEYWELL Smoke Detector: The HM Series photoelectric smoke detectors by Honeywell have a completely new detection chamber design, the result of many years of research and development. This delivers improved responsiveness, reduced sensitivity changes caused by settling dust and reduced false alarms resulting from ingress of insect and other debris. The plug-in unit uses sophisticated processing circuitry that incorporates smoothing filters to help eliminate transient environmental noise conditions that can be the cause of unwanted alarms.Available with or without short circuit isolation Dual integrated LED for 360Deg visibility Advanced protocol and smoothing filter to suppress false alarm Enhanced smoke chamber design to reduce false alarms by dust or contamination Worldwide proved reliability Certifications: EN54-17: 2005 EN54-7: 2000+A1:2002+A2:2006 LPCB approved complete all as specified and directed by Engr-in-Charge |
| 70 | S&F in replacement of HONEYWELL Sounder: VAD-series wall mount sounder beacon is a high quality loop powered device designed to alert building occupants of an emergency. It utilises the B501AP base for improved installation flexibility. When triggered by the fire panel its powerful sounder and intense beacon give a visible and audible warning. A choice of output levels and tones make the device suitable for a wide variety of applications Faster installation Reduced full life costs Flexible installation Reduced inventory count Excellent system performance Certifications: EN54-23 approved LPCB VdS Approved & Listed to AS 7240.3 SAI Global Listing# SMK40640-5 AS 7240.23 complete all as specified and directed by Engr-in-Charge.Locations: New ATC, DWR, JFS Test Cell |
| 71 | Supply and fix in repairs of Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module without SIL-2 complete all as specified and directed by Engr-in-Charge. |
| 72 | Supply & fix in repairs of battery maintenance free 6 volt 7 AH complete all as specified and directed by Engineer in Charge. |
| 73 | Supply & fix of addressable type loop card for Edward panel addressable complete all as specified and directed by Engineer in Charge. |
| 74 | Supply and fix in replacement of SMPS unit suitable size and capacity for siemens fire alram panel complete all are specified and directed by Engr-in-Charge |
| 75 | M&L for analysing defects after installation of unsv items and get rectification of minor defects on working condition including replacement of minor parts, soft ware upgradation and other required works all as specified and direted by Engr-in-Charge. |
| 76 | M&L Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl Stove enemelled steel conduitwith accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet fixed surface to wallsand 1.5 sqmm PVC insulated, unsheathed copper conductor multistrandedcable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for |
| 77 | One light point/fan/bell point controlled by one switch |
| 78 | S&F Switch flame proof rotary type with termination box inLM6, 16A, single pole 250V complete all as specified and as directed. |
| 79 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size |
| 80 | S&F Flame proof class 1 zone 1 weather proof wall mounting fan 15\" (380mm) sweep 1440 RPM single phase suitable rated 240 volts 50 cycle with CMR/CPRI hazardous area gas group IIA/Iib with fabricated construction casing suitable propeller wheel with dynamically balanced blades to avoid frictional spark hazardous front and rear wire guards 01 No, M-20 cable entry etc suitable for wall/bracket mounting arrangement etc duly dark grey epoxy powder coated as per shade 632 of IS-5 complete in all respect including wiring MES No 2 CM height with synthetic enamelled black paint all as directed. |
| 81 | Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen \"A\" clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 82 | S&F junction box dia 120x70H complete all as specified and as directed. |
| 83 | Supply and fixing flame proof MCB DB SPN 4 way 230 volt incing MCB 32 Amps SPN-01 No and MCB SP-6 Amps 10 KA outgoing -02 Nos complete all as specified and directed |
| 84 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly inground (Earth pit not less than 2.25 Mtr deep below normal ground level )with topedge of the plate not less than 1.5 Mtr belownormal ground level connecting with galvanizediron GI earth wire 4mm dia by means ofbolt nut check nuts and washersof galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate,earth work in any type of soil,all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessaryearth work, PCC pit, RCC cover, funnel with watering pipe, GI earth wire upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing complete all as specified and as directed. |
| 85 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and as directed. |
| 86 | Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 87 | Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed. Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge. |
| 88 | M&L Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as specified and directed. |
| 89 | Supply and fixing 4 feet, LEDlight fitting 18 watts(T-8) with out put of not less than 110lumens/watts , boxtype made with epoxy white powder coated CRCA sheet steel(decorative) light fitting having G13 bipin holders compitable for mounting on wall/ceiling/surface,ermisible limit of CRI range,with recommended burning hours ,4000K/6500Ketc , 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, including provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting with integrated driver ofLED tube rod 4\" x 18 watts complete all as specified and as directed. |
| 90 | S&F modular switch 1 way 6 Amps, 1 module complete all as specified and as directed. |
| 91 | S&F white cover plate with frame, 3 Module complete all as specified and as directed. |
| 92 | S&F metal flush box 3 module complete all as specified and as directed. |
| 93 | Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 94 | M&L cable with AI conductor PVC round sheathed (flexible) industrial cable complete all as specified and as directed. |
| 95 | S&F ceiling rose, surface type Bakelite 65x55mm3 terminal complete all as specified and as directed. |
| 96 | S&F Air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and as directed. |
| 97 | S&F Triple and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 amps complete all as specified and as directed. |
| 98 | S&F of sheet metal enclosure for DB double door triple pole and neutral 415V 50 Hz 4 Way complete all as specified and as directed. |
| 99 | Supply and fixing MCB SP 6-32 amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996 complete all as specified and as directed. |
| 100 | S&F 415 V, 10 KA TP 25 to 63 Amps C curve MCB of current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed. |
| 101 | Supply and fixing RCBOs for earth leakage overload & short circuit protection 100 amps 4 pole 100 mA complete all as specified and as directed. |
| 102 | M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable4 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.Note :5 runs of cable and one run of PVC conduit measured as one unit. |
| 103 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as specified and as directed. |