Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-01-2026 | CorrigedndumNo1dated19Jan2026 | Other | 17-02-2026 |
| Sl. No. | Item Description |
| 1 | Note:- Please refer Schedule \"A\" Notes given on serial page No. 19 to 24 of tender documents. |
| 2 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 3 | Lump sum price worked out by the contractor for BUILDING WORK as listed in Schedule \"A\" Part-I brought forward from serial page No.25 |
| 4 | Lump sum price worked out by the contractor for EXCAVATION AND EARTHWORKS (SITE CLEARANCE) as listed in Schedule \"A\" Part-II brought forward from serial page No.26 |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule \"A\" Part-III brought forward from serial page No. 27 to 31. |
| 6 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule \"A\" Part-IV brought forward from serial page No. 32. |
| 7 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule \"A\" Part-V brought forward from serial page No. 33 & 34. |
| 8 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule \"A\" Part-VI brought forward from serial page No. 35. |
| 9 | Lump sum price worked out by the contractor for CHAIN LINK FENCING AND STEEL GATE WORKS listed in Schedule \"A\" Part-VII brought forward from serial page No. 36 & 37. |
| 10 | Lump sum price worked out by the contractor for ROAD AND PATH WORKS as listed in Schedule \"A\" Part-VIII brought forward from serial page No. 38 to 40. |
| 11 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule \"A\" Part-IX brought forward from serial page No. 41. |
| 12 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule \"A\" Part-X brought forward from serial page No. 42 to 45. |
| 13 | Lump sum price worked out by the contractor for SOLAR WATER HEATER WORK as listed in Schedule \"A\" Part-XI brought forward from serial page No. 46 & 47. |
| 14 | Misc items of Works(To be quoted by Bidder) as listed in Schedule \"A\" Part-XII |
| 15 | INTERNAL ELECTRIFICATIONWORKS |
| 16 | Material & labour for point wiring with 1.5 sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit medium grade 20mm dia (minimum) or higher size as specified and cutting chasing on wall complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc/ fittings ISI marked for modular fittings andbrass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed.Note:- Cost of Metal boxes and modular accessories like cover plates will be paid seprately in respect items (a)Fan point/ exhaust fan point /one light point/bell/buzzer controlled by one switch/bell push. |
| 17 | (b)One socket outlet 5 pin 5 Amp controlled by one, one way switch on same board. |
| 18 | (c) One socket outet point 5 amps on the independent board. |
| 19 | (d) One light point controlled by two nos of two way switch. |
| 20 | All as Ser item 4.01 here in before but with 2.5 sq mm wire and earth wire of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet. |
| 21 | Supply and fix modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 8 module complete all as specified and directed. |
| 22 | Supply and fix modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 12 module complete all as specified and directed. |
| 23 | Supply and fixing modular white cover plate with frame, 12 module complete all as specified and directed. |
| 24 | Supply and fix modular Dummy plate complete all as specified and directed. |
| 25 | Supply and fixing LED energy efficient LED bulb B22 9 watt complete all as specified and directed. |
| 26 | Supply and fixing VTPN DB’s 4 Way, Double door, 415V, IP43, suitable size and length of CRCA steel sheet, dust protection duly powder painted including factory fitted suitable size copper bus bar, 01 No of MCCB TPN as incomer and 04 Nos TP as outgoing with neutral link, earth bar, din bar for mounting MCB and blanking plate a complete all as specified and directed. Note:- MCB shall be measured and paid for separately. |
| 27 | Supply and fixing TV socket/Telephone socket and connector complete with all necessary fittings all as specified and directed. |
| 28 | Material & labour for wiring with 1100 volt grade one single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 1.5 sqmm (FOR INVERTER) drawn into PVC conduit with all accessories fixed concealed complete all as specified and directed. Note: One run of 1.5 sqmm PVC FRLS multi stranded copper cable wire with seperate colour coding for inverter should be used, no extra cost will be paid in this account. |
| 29 | Supply and fix LED tube light fitting for all purpose surface and wall mounted with single side connection polycarbonate LED batten with 125 Lum/watt system efficancy polycarbonate housing and integrated electronic driver of capacity 20 W, four feetand connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. |
| 30 | Supply and fix wall/ceiling mounting LED 9/10 Watt tube light fitting with polycarbonate housing and integrated electronic driver complete withall acessories 1x9 Watt LED, with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed. |
| 31 | Supply and fix bldg street fitting made up of pressure dai cast aluminum housing with high efficiency LEDs as a lighting source and lens embedded PC Cover Having TOP oppening seperate driver compartment with IP 66 protection and impact resistance of IK07, CCT 5700 K, of wattage 25 Wattincluding connection with 3 core PVC insulated overall sheathed flexible cable with multi stranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal all as specified and as directed. |
| 32 | Supply and fix GI pipe bracket made of GI pipe light grade 32mm dia and bend to shape 1.5 mtr long MS clamp made out of MS flat iron2 Nos of size 32mm x 4mm with nut and bolts washer fixed to walls/ poles complete including drilling of holes for nut and bolts etc complete all as specified and directed. |
| 33 | Supply and fix energy saving new generation 10 watt LED built up, 6000kbulk head luminaire with opal diffuser light fitting complete with all acessories and connection complete. |
| 34 | Supply and fixing Decorative LED wall light fittings, including 9/10 Watt, 220 W LED Lamp B22 base complete all as specified and directed. |
| 35 | Supply and fix Bed side light fitting wall type aluminium base body flush mount 6 watt LED fixed on wall at suitable height all as specified and directed. |
| 36 | Supply and fix Kitchan Wall Fan 300 mm sweep,1350 RPM, of Elegantly designed fan base in round shape for 50 cub mtr/min air delivery and minimal noise levels with pull code control for speed & oscillation upto 90 degree total flexibility, double \"z\" shielded ball bearing, sturdy brazed wire guards with power coating ensures corrosion resistance conforming to IS 2997-1964 complete all as specifed and directed. |
| 37 | Supply and fix Kitchan Chimney Dry Heat Auto Clean Technology Stainless with Air outlet 150 mm, Steel Finish Front Matte Black Glass panel with Digtal Display Touch Control Panel with 3 Speed Gesture motion, Heavy Duty Baffle Filters, minimium Air flow 1180 M3/h Energy Saving LED Light of suitable wattage, Copper winding BLDC Motor, 62dba max noise level and voltage 220-240 V/50 Hz including making hole in the wall and making good the distubed surface of wall including all accessories all as specified and directed. Make : KAFF Model No.SKU NEVISHC90 or eqvt in Hindware/ Faber. |
| 38 | Supply, installation, testing & commissioning of 3-Φ, 4 Wire, AC Static Direct connected, Smart Pre-paid Energy Meters, ISI marked of different makesas per BIS-16444, with communication technology including GPRS/RF/Hybrid (RF Mesh Network+GPRS)/any other advanced technology as per CEA/TRAI regulations) with current range 10-60 Amp, 415 V, accuracy class 1.0 UC1 category and above along with in-built load control switch, containing provision for TOD & RTC, capable to define multiple tariff slabs complete all as specified and directed.Meter should support the following data:- (i) 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, daily and monthly billing survey for Cumulative Energy and Max Demand(ii) Meter should have connect / disconnect functionality operable for MDM/billing software and prepaid features would be operable for MDM / Billing end as per IS: 15959 Part-2.(iii) Meter should support communication protocol through RF/ 5G/4G/NB IOT with the existing software in stn all as required at site and directed (cost of 5G/4G/NB IOT sim with two year recharge facilities, mapping, vending portal charges etc deemed to included in rate quoted for meter). (iv) The meter should support open communication protocol DLMS with the existing software.Make: Anchor/L&T/HPL/Secure.Note:- (i) The smart meter would be compatiable with existing software/DCU in Stn.(ii) The rate of sim as well as data pack of 24 months from date of completion for connectivity is deemed to be including in the quated rates. |
| 39 | Supply & fixing of Transparent polycarbonate Meter Box of suitable size with IP-54 for 3-Φ, 4 wire, Smart Energy meter mentioned here-in-above at Sch. Item No. 53. The Polycarbonate meter box shall comply with IS-14772:2000 and IS-11000:1984. It shall be totally shock proof, safe weater proof, rust roof, dust proof, water proof, halogen free, silica free and having internally embeded gasket technology, transparent hinged lid and sealing provision including bakelite connector, complete all as specified and directed. Make: Anchor by Panasonic/L&T/ HPL/Secure. |
| 40 | INTERNAL WATER SUPPLY WORKS |
| 41 | Supply & fixing 15mm CP brass health faucet (hand shower), inlet length 100mmfixed to angle valve with and including decorative choice flexible pipe, wall hanger etc complete all as specified and directed. |
| 42 | Supply and fixing for 15mm bore fancy type central hole single lever basin mixer with 450 mm swivel spout Connecting Legs & wall Flanges & including all necessary fittings all as specified and directed. |
| 43 | Supply and fixing for two way bib cock with single handle and wall flange 15mm dia, fancy type chromimum plated including all necessary fittingsall as specified and directed. |
| 44 | Supply and fixing for 15 mm bore Sink Mixer with Swinging Spout (Wall Mounted) with 150mm long braided connection pipes & including all necessary fittings all as specified and directed. |
| 45 | Supply and fixing for 15mm dia Wall Mounted Bib Cock, Chromium plated, with wall fang and aerator including all necessary fittings all as specified and as directed |
| 46 | CHAIN LINK FENCING & STEEL GATE WORKS |
| 47 | Supply only 3.15mm dia PVC coatedgalvanised wire chain link fencing, size of mesh 75x75mm complete all as specified directed. |
| 48 | ROAD AND PATH WORKS |
| 49 | Supply and fix Road safety convexPolycarbonate reflective mirrors of size 100 cmsbody made of ABS/Fibre/Plastic with hood and mounting hardware with100mm GI Pipe 1.50m long embedded in PCC bed block of size 300x300x400mm in PCC 1:3:6 type C-1 using 20mm graded stone aggregate complete all as specified and directed. |
| 50 | EXTERNAL WATER SUPPLY WORKS |
| 51 | Material & labour For Taping from existing DI 150 mm to DI 100 mmincluding cutting , jointing and inserting tee and all accessories complete all as specified and directed. |
| 52 | Supply and lay of centrifugally cast (Spun) ductile iron pressure pipe with Spigot & Socket end,100 mm dia class K-7 conforming to IS : 8329/2000 including for rubber gasket jointing with centrifugally applied inside cement mortar lining with portland slag cement and external metallic zinc coatingwith finishing layer of Bitumen coating on external surface including Ethylene propylene diene monomer (EPDM) rubber gasket conforming IS :5382 of bulb type -2 as per IS 5382 complete all as specified and directed. |
| 53 | Material & labour for valve pits and constructing of brick masonary pits of internal dimensions 900mmx900mmx900mm(bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be constructed in PCC (1:3:6) 50 cms thick with 20 mm stone aggregate , inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. The sluice valve and other fittings should be housed in center of the pit. The vertices of the pit should in right angle and champhered. The top cover of the pit will be made out of MS sheet min 2 mm thick with angle iron frame made out of MS angle 50 mm x50 mm x 6mm with galvanized steel hindges two nos and locking arrangements duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide complete all as specified and directed. |
| 54 | EXTERNAL ELECTRIFICATION WORKS |
| 55 | Supply Install, testing and commissioning ofMain LT Distribution Panel (CPRI type tested ) cubicle type IP-65,outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extensionlinks of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of plateform. The plateform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class\"B\") work duly plastered in CM 1:3 and PCC copping (1:2:4) not less than 50 mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge.. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seventank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-Note : (i ) LT panel board should be Type Tested from CPRI (A copy of valid CPRI type test report to be enclosed while obtaining approval from GE)(ii)SLD diagrame for LT panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door.(iii)Rate for the same deemed to include in the quoted rates. |
| 56 | Incomer of LT Panel :- (i)MCCB 4 pole 415 Volt, 350 Amps, 36 KA, with fixed magnetic & thermal adjustable-01 Nos(ii) Bus bars : 600A TPN + Ebusbars running throughout the length of panelOutgoing feeders : (i)MCCB 4 pole 415 Volt, 350 Amps, 36 KA, with with fixed magnetic & thermal adjustable-01 Nos(ii) Voltmeter 0 to 500 volts digital type with selector switch -01 Nos(iii) Ampere Meter 0 to 400 amps digital type with selector Switch-01 Nos(iv) LED Phase Indicator Lamp = set of three(v) All connection From MCCBs to bus bar & bus bar to MCCB shall be made with suitable size of all aluminium strip thimble lugs.(vi) Pre-wired with copper conductor cable single core strand PVC insulated with aluminum thimble lugs etc all as specified & directed by Engr-in-charge. |
| 57 | Supply Install, testing and commissioning of Main LT Panel 2 , LT Distribution Panel (CPRI type tested ) cubicle type IP-65,outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extensionlinks of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of plateform. The plateform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class\"B\") work duly plastered in CM 1:3 and PCC copping (1:2:4) not less than 50 mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge.. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seventank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-Note : (i ) LT panel board should be Type Tested from CPRI (A copy of valid CPRI type test report to be enclosed while obtaining approval from GE)(ii)SLD diagrame for LT panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door.(iii)Rate for the same deemed to include in the quoted rates. |
| 58 | Incomer of LT Panel :-(i)MCCB 4 pole 415 Volt, 350 Amps, 36 KA, with fixed magnetic & thermal adjustable-01 Nos(ii) Bus bars : 600A TPN + Ebusbars running throughout the length of panelOutgoing feeders : (i) MCCB 125 Amp 4P 25 KAwith fixed magnetic & thermal adjustable-04 Nos (ii) MCB TP 415 Volts 25 Amp -01 Nos.(iii) MCB TPN10 Amp-02 No(iv) Digital Timer Switch with astronomical function for switchingON/OFF street lights 2 module-01 Nos(v) Contactor 32 Amp TPN,Capacity and MCB TPN Outgoing 16 amp -02 Nos (For Street Light Feeders)(vi) Voltmeter 0 to 500 volts digital type with selector switch -01 Nos(vii) Ampere Meter 0 to 400 amps digital type with selector wwitch-01 Nos(viii) LED Phase Indicator Lamp = set of three(ix) All connection From MCCBs to bus bar & bus bar to MCCB shall be made with suitable size of all aluminium strip thimble lugs.(x) Pre-wired with copper conductor cable single core strand PVC insulated with aluminum thimble lugs etc all as specified & directed by Engr-in-charge. |
| 59 | Material & Labour for construction of platform for mounting of outdoor type transformer using brick masonary of sub class \"B\" brick (old size) .The platform size is 3000mmx3000mmx1200mmsuitable for cap160 KVA including 1 meter working space all around . Surface excavation including depth of footing upto 550 mm below the normal ground level including PCC 1:5:10 type E-2 of 100mm thick for brick work and brick work in double brick 450mm depth upto ground and full brick work upto 1200 mm height. The inside of plinth/platform shall be filled with 40 mm thick aggregate filling up to 950 mm height above the normal groung level, 150 mm thick PCC 1:4:8 type D-2 ( using 40 mm graded stone aggregate) and there after PCC 1:2:4 type B-1 ( using 20 mm graded stone aggregate) of thickness 100 mm over plateform and 15 mm thick rendering CM 1:6 complete all around including two coat of cement base paint over a coat of primer on plateform wall and any other type of civil work, earth work,excavation required. Theplinth/ platform should have brick steps (90 cm width) on one side for approach to top of platform. The plinth/ platform fencing 1 mtr space all around platform shallhave 3 to 4 mm dia PVC coated galvanised mild steel chain link fencing of mesh size 75X75 mm upto height 2.0 mtr all around the area and fixing of chain link fencing with angle iron of 50X50X6mm angle iron fixed in ground upto depth of 45 CM in concrete 1:2:4 and fixing of chain link with mild steel screw or bolts with hexogonal or square heads including 10 mm dia steel bars and4X danger plate for 11000 V fixed to each side of Transformer fencing. Provision of one opening gate size 1 m wide & 2.1 m in height with locking arrangement with angle iron including 2 coat of synthetic paint over a coat of red oxide primer enamel complete all as specified and directed by Engr-in-charge.Note :- Any Excavtion/ earth work and PCC work shall be deemed to be including in the quoted rates. |
| 60 | Supply,laying & fixing of double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc. ofsize 63mm outer dia and 50 mm inner dia. complete all as specified and directed. |
| 61 | Supply,laying & fixing of double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc. ofsize 80 mm outer dia and 63 mm inner dia.complete all as specified and directed. |
| 62 | Material & labour for drilling hole under the road, pavment, hardstanding by Mechanically or mannually by boringg with bockee for making suitable size of holes for passing LT cable of any size with provn of DWC HDPE pipe of suitable sizescomplete all as specified and directed. |
| 63 | Supply and fixing LED street Light Fitting 45 Watt,230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver ,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 Protection complete all as specified and directed. |
| 64 | Supply and fixing of three core PVC insulated cable with stranded copper conductor of size 1.5 Sqmm complete all as specified |
| 65 | Supply & installation hot dip galvanised octagonal poles 7 mt long ,top dia 70 mm ,bottom dia 130 mm having sheet thickness 3 mm, base plate 200 mm x 200 mm x12 mm (LxBxT) including foundation bolt size 4x20 mm dia, 200 mm pitch circle dia, 600 mm bolt length, 100 mm projected bolt length, having door opening of sizes 90x500 mm above GL and having hot dip galvanized single arm plane arm bracket 1000 mm long for pole having top 70 mm dia, for mounting street light fitting fixed on the top with nut bolts washers including provision of cable 2.5 sqmm 3 core & cable connector for three phase supply and one no MCB SP of 0.5 A to 6 A complete alongwith necessary earth work , PCC, with iron work all as specified by the manufacture as approved by GE and as directed. |
| 66 | ARBIRICULTURE |
| 67 | Surface excavation not exceeding30 cm deep and averaging 15cm deep and getting outin soft/loose soil , seprate the roots/grass and good earth by sieving with suitable seive size ,stacking of good earth & mixed with suitablemanure of ratio 5:1 including supply of manure,screened through sieve of 1.5 designation 4.75 mm and spreading the mixture of good earth & manure , applying suitable pesticides , watering to a depth of15cms, including removal of roots/grass out of site Material andlaying of \"DOOB GRASS\"/ Carpet Grass planting complete as aprroved and as directed by the Garrison engineer. |
| 68 | Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting outthe existing earth and planting the trees straight inside the pit and filling up the pit with and including the approvedearth along with and manure (composit) in the proportion (3:1) and including SupplyandPlanting \" Bottle Palm Tree\" with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed. |
| 69 | Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting outthe existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved earth along with and manure (composit) in the proportion (3:1) and including SupplyandPlanting \" Fristle Palm Tree \" with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed. |
| 70 | Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting outthe existing earth and planting the trees straight inside the pit and filling up the pit with and including the approvedearth along with and manure (composit) in the proportion (3:1) and including SupplyandPlanting \" Golden Duranta Hedge \" with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed. |
| 71 | Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting outthe existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved earth along with and manure (composit) in the proportion (3:1) and including SupplyandPlanting \" Golden palm Tree \" withproportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed. |
| 72 | Provision of tree guard ( MS Angle with GI net) of suitable size around trees upto a height of 60cm all as specified and directed by Garrison Engineer. |
| 73 | (MAINTENANCE AND UPKEEPING OF NEWLY DEVELOPED PLANTS/ GARDENS UNDER ITEMNO 10.01 to 10.06 FOR 12 MONTHS)Day to Day maintenance of newly developed plants/gardens/Trees plants by deploying minimum 02 gardner (experienced Mali) for guarding / security of the plants/ gardens including triming, suitable support for trees, etc as required as per standard practice all as specified and all as directed bythe Garrison Engineer.NOTES :-(i) Periodical deweeding of unwanted vegitation growth around the plants and garden area.(ii) Watering all the Plants/Gardens/Trees as required for the proper growth.(iii)Periodical Lawn Mowing.(iv) Treating the plants and soil with required manure , pesticides and fertilizer including necessarytopping of red earth and finally fine dressing, levelling etc(v) During the maintenance of any plant, if itis found dead, not true to the name or size as specified or not in satisfactory growth, plant of approved size & shape shall be replaced by the contractor without any extra cost to the Department.(vi) Supply and application of manure, sweet earth & pesticides, fertilisers, cartage as required etc are included in quoted unit rate during maintenance period.(vii) Commencement of maintenance period of two years will commencedonly after certified date of completion of work.(viii) Water willbe supplied by MES .(ix) Hose pipe required for watering will be provieded by the contractor and their cost is deemed to be included in the unitrates quoted by the contractor.(x) Cost of maintenance and upkeep will be deemed to be inlcuded in quoted rates. (xi) Necessary T&P required shall be arranged by the contractor |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail