| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified |
| 2 | M&L PCC 1:3:6, type C-1(using 20mm graded crushed stone aggregate) in foundation , filling and mass concrete all as specified and directed. |
| 3 | M&L for mild steel works in fencing post and struts incl cutting tops to shape as directed, drilling holes, notiching wire, etc, FI Filitres(for securing wire mesh etc) incl all necessary drilling bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 of any section and sizes, including taking down old gates or ladders of any size and in any position complete all as specified and directed. |
| 4 | M&L for Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire including dismantling old unservicable mesh complete all as specified and directed. |
| 5 | Supply in replacement ofchain link MS galvanised fencing any size or type all as specified and directed |
| 6 | S&F Framed work such as grills,gratings, gates with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 of any section and sizes, including taking down old gates or ladders of any size and in any position complete all specified and directed. |
| 7 | M&L for preparation of new steel and iron surfaces of any description over 10 Cm in width or grith, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 8 | M&L for preparation of new steel and iron surfaces of any description over 10 Cm in width or grith and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint complete all as specified and directed |
| 9 | M&L Pre-Cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar 1:6 complete. |
| 10 | M&L PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggrgate)as in foundation filling and mass concerte complete all as specified and directed |
| 11 | M&L for preparing newly plastered surface of Walls and applying with three coats of white wash complete all as specified and directed. |
| 12 | Rendaring 10 mm thick in cement and sand mortar 1:6 on concrete or brick work surface all as specified and directed. |
| 13 | M&L in replacementfor earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mmby means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soilto a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),\"mild steel angle iron frame\" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia mediumgrade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate lay in replacement ers of charcoal dust and common salt complete all as shown inelectrical \"plate No \"3\" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed. Note: After completion earth resistance shall be recorded with earth megger and the record should be submitted to to department duly signed by contractor. |
| 14 | Earthing complete with galvanised steel pipe electrode in replacement, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test pointwith and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),\"mild steel angle iron frame\" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia mediumgrade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate lay in replacement ers of charcoal dust and common salt complete all as shown inelectrical \"plate No \"3\" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed.all as specified and indicated including testing on completion |
| 15 | Removing old paint of LT Panel by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth |
| 16 | M&L for preparation of LT Panel steel surfaces and applying one coat of red oxide primer and one coat of synthetic enamel paint complete all as per |
| 17 | Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size(Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBsof capacityUP TO630 Amps,4 Pole, 36 KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed. |
| 18 | All as per item No 17.00 here in before but of capacity 315-400 Amps, 4 pole, 35 KA |
| 19 | All as per item No 17.00 here in before but of capacity 250 Amps, 4 pole, 25 KA |
| 20 | All as per item No 17.00 here in before but of capacity 200 Amps, 4 pole, 25 KA |
| 21 | All as per item No 17.00 here in before but of capacity 160 Amps, 4 pole, 16KA |
| 22 | All as per item No 17.00 here in before but of capacity 125 Amps, 4 pole, 16 KA |
| 23 | All as per item No 17.00 here in before but of capacity 100 Amps, 4 pole, 16 KA |
| 24 | All as per item No 17.00 here in before but of capacity 63 Amps, 4 pole, 16 KA |
| 25 | S&F in replacementOFF-Load changeover switch (In sheet steel enclosure), AC 21 (Side Handle), 4 pole of capacity 200 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed. |
| 26 | S&F in replacement OFF-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 100 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed. |
| 27 | S&F in replacement OFF-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 63 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed. |
| 28 | Supply only of aluminium cable lugs of following sizes :- |
| 29 | 16to 25 Sqmm Size |
| 30 | 35to 50 Sqmm Size |
| 31 | 70to 95 Sqmm Size |
| 32 | 120to 150 Sqmm Size |
| 33 | 185to 240 Sqmm Size. |
| 34 | S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 25*20cm all as specified and directed by Engr-in-Charge. |
| 35 | M&L 100mm thick for moorurn/ red bajini filling including spreading leveling watering and consolidated to gradiant and camber required all as specified and as directed |
| 36 | Hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 37 | M&L for Shingles or gravels , spread , levelled and consolidated to gradient required of 50 to 75mm spread thickness as specified for transformer yards etc. all as specified and directed. |