| 1 | Complete removal of all existing roof treatment from RCC roof including old hussion felt, tiles etcand preparation of surface with bire brush and cleaning with water complete all as directed. |
| 2 | M&L for 40 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregateto roof , floor,chajja, RCC shelves etcat water retaning surfaces with WPC and make proper good slope as directed (Note-wpc will be measured and paid seprately) |
| 3 | M&L for preparation of concrete roof surfaces and applying 10mm thick plaster in CM 1:4 and finished the surface even and without using extra cement complete all as specified and directed. |
| 4 | Supply only liquid water proofing compound.ISI Marked |
| 5 | M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces |
| 6 | M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed |
| 7 | M&L for applying two coats aluminium paint over bituminous surface of membrane |
| 8 | M &L providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in lintel upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, stringcourses lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones bed plates,kerbs incl weathering slightly rounded or chemfered angles and throating as directed. |
| 9 | Taking down eaves gutters and rain water pipes (any size or patterns)including all fittings,heads,shoes,bends,swan-necks etc complete all as specified and as directed by Engr-in-Charge. |
| 10 | S&F PVC(SWR)pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp complete all as specified and as directed by Engr-in-Charge. |
| 11 | S&F PVC(SWR)bends any radius 110 mm dia complete all as specified and as directed by Engr-in-Charge. |
| 12 | Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar |
| 13 | M &L for Brickwork with fly ashmodular bricks, strainght or curved on plan exc 6M mean radious radius built in Cement mortar 1:6complete all as specified and directed. |
| 14 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 15 | M&L for rendering 15 mm thick in cement mortar 1:4on wall of brick work or concretesurface, finished fair and even all as specified and directed. |
| 16 | M&L for rendering 15 mm thick in cement mortar 1:6on wall of brick work or concretesurface, finished fair and even all as specified and directed. |
| 17 | M&L for rendering 5 mm thick in cement mortar 1:3on ceilingof brick or concretesurface, finished fair and even all as specified and directed. |
| 18 | Material and labour for preparation of OLD plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 19 | Material and labour for preparation of NEW plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 20 | Materials & labour for prepration of NEW plastered surface and finishing the surfaces of wallwith wall putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. |
| 21 | Materials & labour for prepration of OLD plastered surface and finishing the surfaces of wallwith wall putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. |
| 22 | Material & Labour for preparation of new plastered surfaces applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified & directed.. |
| 23 | M & L for complete removal and preparation of old plastered surfaces applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified & directed.. |
| 24 | M&L forrepair and rendering 10mm thickin cm 1 :3on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete includingcleaning of viisible reinforcementandtreating with cement slurry also necessary repair to cracked concreteif any with cement concrete1:2:4 Type B-0 using 12.5mm gradedaggregateincluding necessary scafolding work for double/single storey bldgs all as directed . |
| 25 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 26 | M &L forVirified Ceramic tiles Double charged 8 to 10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 27 | As per item No 18 in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 28 | Taking down Rolling Shutter exc 10 Sqm but n.exc 18.00 Sqm each with shutter without taking of shutter from framed complete incl removing from site |
| 29 | S &F Steel rolling shutters,1.25 mm tk of laths with out ball bearing, as specified including top cover, an choring rod, Guide channel, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type and incl Safety lever locks mild steel with 4 levers for rolling shutters-2 Nos complete all as specified and directed. |
| 30 | S &F Steel rolling shutters,1.25 mm tk of laths with out ball bearing, as specified including top cover, an choring rod, Guide channel, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: but gear operated type with bevel gear box and crank handleand incl Safety lever locks mild steel with 4 levers for rolling shutters-2 Nos complete all as specified and directed. |
| 31 | S&F of Ball bearing for rolling shutterscomplete all as specified and directed. |
| 32 | M/L for preparing the new surface of any description not otherwise described over 10 cm width or girth on steel surface and applying 02xcoats of synthetic enamel paintall as specified |
| 33 | Taking down chowkhat with shutter without taking off shutter from chowkhat exceeding 1.5 Sqm but n.exc 4sqm each complete all as specified and as directed by Engr-in-Charge |
| 34 | S&F powder coated alumunium glazed door shutter with two panel made of vertical style of size 85x44.5x1.5mm and Top rail size 114.30x44.5mmx1.5mm bottom rail 150mmx44.5mmx1.5mm and middle rail 114.3mmx44.5mmx1.5mm all alumunium section including all fittings as per door shutter such as alumunium door handles round type-2 Nos ,stainless steel hinge 100mm size -4Nos,central mortice lock ,alumunium tower bolts 300mm-2 Nos double leg alumunium anodised door stopper and hydraullic door closer ,designation No 2, universal type ,cast iron body ISI marked and necessary clips rubber packing and alumunium beading to receive and including 5.5mm thick plain tined glass or 6mm thcik alumunium composite panel in top and bottom panel. complete all as specified and as directed by Engr-in-Charge. (Note: Door shutter will be measured outer to outer frame and no extra will be paid). |
| 35 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, and necessary clips rubber packing and alumunium beading to receive and including 5.5mm thick plain tined glass or 6mm thcik alumunium composite panel in top and bottom panel. complete all as specifiedall complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 36 | Demolition of cement concrete in ground floors and paving exc 15cm thickness(below or above ground level) all as directed. |
| 37 | M/L for 75 mm thick cement concrete1:3:6 type C2,using 40 mm stone aggregate finished even & smooth without using extra cement as in plinth protection etc. complete all as specified & directed. |
| 38 | M&L 40 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate), as in floors including finishing cement concrete surface even and smooth without using extra cement complete all as specified & directed. |
| 39 | Supply only glass dividing strips 3mm thick and 38 mm Wide complete all as specified and directed. |
| 40 | M&L forCement concrete work in pavement/hard-standing of flexural strength 40kg/per square centimetre in field using400 kg of cement per cubic metre,thickness of concrete 25 cm or less complete all as specified and directed. |
| 41 | M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound. Complete all as specified & directed. |
| 42 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide,filled with sealing compound Complete all as specified & directed. |
| 43 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed. |
| 44 | Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good thedisturbed surfaces of walls,floors roofs etc complete all as specified and directed. |
| 45 | Taking down Old/ Unserviceable MCBDBs SPN/TPN/ Main Switchesby disconnection of electric connection including old unsvMCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specifiedand directed. |
| 46 | M&L point wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed.Note: Therate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing ofswitch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces. |
| 47 | All as per Ser item No 46 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 48 | All as per Ser item No 46 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 49 | All as per Ser item No 46 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 50 | S&F Switch modular 1 way 6 Amps single pole complete all as specified & directed. |
| 51 | S&F Switch modular singlepole , one way 16 Amps complete all as specified and directed. |
| 52 | S&F Socket modular 2/3 pin combined 6 Amps complete all as specified and directed. |
| 53 | S&F Socket modular 2/3 pin combined 6/16 Amps complete all as specified & directed. |
| 54 | S&FCeiling rose,3 terminal PVC/polycarbonatecomplete all as specified and directed. |
| 55 | S&F modular Fan step regulator 230 Volts single phase 120 watt, 2 modulecomplete all as specified and directed. |
| 56 | M&L for submain complete with 2x4 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm diaas per site requirement along walls/ceilingetc including4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces.(iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length) |
| 57 | Supply and fixMCBDB SPN 8 way double door with metal door suitable forhousing of MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 58 | Supply and fix MCCBDB VTPN 4 way with metal door suitable forProvision ofincommer and out going MCCBs/MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 59 | Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed. |
| 60 | S&F in replacement ofMCB SP 6 to 32 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 61 | S&F in replacement of MCB DP 40Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles. |
| 62 | S&F in replacement ofisolator DP 63 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 63 | S&F in replacement of LEDtube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting withaluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed. |
| 64 | S&F wall monted fan AC single phase, 230Volts of size 450 mm sweep, WM SSTORM 2 (Metal blade & Base)complete includingnecessary electric connection complete all as specified and directed. |
| 65 | S & F Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air dilivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 66 | S&F in replacement of building LED security light fitting 25 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device.luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site. |
| 67 | Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductorcable all as directed. |
| 68 | Excavation intrenches in loose/soft soil not exceeding 1.5 metrewide and not exceeding 1.5 metredeep for laying of cables,poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as specified. |
| 69 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and directed. |
| 70 | Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick |
| 71 | Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed. Note : Punned down thickness shall be considered for measurement |
| 72 | Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed |
| 73 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earthstripof size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I filling with charcoal dust , and common salt,including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EICNote :(i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate. |
| 74 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |