| 1 | SCHEDULE \"A\" SECTION-I(BUILDINGS/STRUCTURE WORKS) |
| 2 | Lump sum price worked out by the Contractor for “Buildings / Structure Work” as listed in Schedule ‘A’ Section-I. |
| 3 | SCHEDULE ‘A’ SECTION-II (INTERNAL WATER SUPPLY WORKS)Lump sum price worked out by the Contractor for “Internal Water Supply Works” as listed in Schedule ‘A’ Section-II. |
| 4 | SCH ‘A’ SECTION-III (INTERNAL ELECTRIFICATION WORKS)Lump sum price worked out by the Contractor for “Internal Electrification Works” as listed in Schedule ‘A’ Section-III. |
| 5 | SCHEDULE \"A\" SECTION-IV (SEWAGE DISPOSAL WORKS)Lump sum price worked out by the Contractor for “Sewage Disposal Works” as listed in Schedule ‘A’ Section-IV. |
| 6 | SCHEDULE \"A\" SECTION-V (EXTERNAL WATER SUPPLY WORKS)Lump sum price worked out by the Contractor for “External Water Supply Works” as listed in Schedule ‘A’ Section-V. |
| 7 | SCHEDULE \"A\" SECTION-VI (EXCAVATION AND EARTH WORK)Lump sum price worked out by the Contractor for “Excavation and Earth Work” as listed in Schedule ‘A’ Section-VI. |
| 8 | SCHEDULE ‘A’ SECTION-VII (MISCELLANEOUS WORKS) |
| 9 | Supply & fixing 15mm bore Angle stop valve, fancy type with long shank and cup of cast copper alloy chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified & as directed. |
| 10 | Material & labour for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium grade, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etcall as per IS, terminated in & including new sunken type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed.Note : (i) Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall be deemed for include for modular metal flush boxes of requisite module as approved by GE. |
| 11 | All as per serial item No. 10.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified & as directed. |
| 12 | All as per serial item No. 10.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified & as directed. |
| 13 | All as per serial item No. 10.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified & as directed. |
| 14 | Material & labour for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metallic rigid PVC conduit (medium grade, ISI marked, not less than 20mm) with all accessories fixed on surface ofwalls/ceiling by means of PVC sleeves / dash fasteners with cadmium plated screws all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed.Note : Cost of cutting/leaving, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 15 | Supply and fixing LED light fitting retro fit type with high out put diffuser 4 feet long, 18/20 watt, 230 Volt, 50 Hz, with replacable rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified & as directed. |
| 16 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 Volts, 50 Hz, AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed. |
| 17 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 Volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cables of suitable size complete all as specified & as directed. |
| 18 | Supply and Fixing Light Emitting Diode (LED) based Flood light fitting, 70 Watt with & including LED lamp, housing made up of LM6 pressure epoxy powder coated die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt, a minimum system lumen output of not less than 7000 lumens, Correlated Colour Temperature (CCT) shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 300 V, AC, frequency 50-60Hz, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 10%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/ polycarbonate/ toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked),including wall/pole mounting bracket made of 40mm bore GI pipe ‘light grade’ not less than 0.60m long, bent to shape of 120 degree angle end welded at required, fixed to wall/pole with & including mild steel clamps (02 Nos) made out of flat iron 40x6mm with nuts, bolts & washers, complete necessary fixing arrangement on wall/pole complete all as specified and as directed. |
| 19 | S&F LED based street/security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, system luminous efficacy of minimum 100 lumens per watt and a minimum system lumen output of not less than 3500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/ polycarbonate/ toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), including wall/pole mounting bracket made of 40mm bore GI pipe ‘light grade’ not less than 0.60m long, bent to shape of 120 degree angle end welded at required, fixed to wall/pole with & including mild steel clamps (02 Nos) made out of flat iron 40x6mm with nuts, bolts & washers, complete necessary fixing arrangement on wall/pole complete all as specified and as directed. |
| 20 | NOTES FOR LED LIGHT FITTINGS :(i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13.(ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80.(iii) Contractor has to furnish a on site replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :-(a) Manufacturing defects.(b) Failure due to mechanical and electrical impact.(c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries. |
| 21 | Supply and fixing MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volts, 16 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed. |
| 22 | Supply and fixing MCB, 40 Amps, Single Pole & Neutral, 240 Volts, 16 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed. |
| 23 | Supply and fixing MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed. |
| 24 | Supply and fixing MCCB, 4 Pole, 100 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, fixed Thermal - Magnetic, complete all as specified and as directed. |
| 25 | Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, rupturing capacity 10 kA, ‘C’ Curve, complete all as specified and as directed. |
| 26 | Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CMM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint complete all as specified and as directed.Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates. |
| 27 | Supply and fixing Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, 300mm sweep, 230V, 50 Hz, 1200 RPM, Copper winding and connecting with & including 1 Sqmm, three core, flexible multistranded copper conductor cable and connected from ceiling rose to fan complete all as specified & as directed. |
| 28 | M&L for sub main wiring with two runs of 1.5 sqmm (nominal area) size main cable & one run of 1.5 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI markedcables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 20mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete all as specified & as directed.Notes :-(i) 02 runs of 1.5 sqmm size main cable, 01 run of 1.5 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 29 | M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI markedcables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete all as specified & as directed.Notes :-(i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 30 | M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI markedcables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete all as specified & as directed.Notes :-(i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 31 | Material and labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4mm dia (upto the test point / cross arms earth lead upto 7.5 meter length from top of earth plate) by means of GI bolts/nuts/washers, protected by 15mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20mm bore GI medium grade pipe for watering and including funnel, wire mesh, Pit cover & frame including necessary excavation & earth work, complete all as specified & shown in electrical plate No. 3 of SSR Part-I. Notes :- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes GI pipe and earth lead upto 7.5 meter length from top of earth plate. |
| 32 | Supply and fixing 12mm thick toughned Glass Door (double leaf) with 2 Nos 450mm long Stainless steel handles and heavy duty hydraulic floor door spring per shutter with locking and fixing arrangement like clamps etc complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fixing tower/pillar type 2.0 Ton Air conditioner unit comprising indoor and outdoor unit electric driven, single phase 230 Volt, 50 Hz having copper condenser coil 1 star BEE Rating, energy efficient with R22 or latest refrigerant. Noise level should not be more then 50 decibels. It should have Dual control , LCD/ LED graphic display for time and temperature, fan speed controller and child lock switch. It should also have elecrical and thermal overload protection device complete all as specified and directed by Engineer in Charge.Note : Quoted rate should be inclusive of copper tubing required and fitting arrangments of outdoor unit. |
| 34 | Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and of capacity 5 KVA including testing complete all as specified & as directed. |
| 35 | M&L for construction of valve pipe internal size 90cmx90cmx90cm of double brick masonary with internal plastering from the top of surface including cover of MS sheet 3.15 thick and angle iron 40mmx40mmx6mm with hinges and locking arrangement including painting with two coats of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 platering in cement and sand mortar 1:3 , foundation concrete 1:3:6 including necessary earthwork complete all as specified and as directed and shown on drawings (CEJZ/TD/2004/26 Sheet No. 1/3 to Sheet No. 3/3). |
| 36 | Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified and directed.Note:- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 37 | Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified and directed.Note:- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 38 | Material & labour for river unwashed dry sand cushioning using sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed. Note :- Punned thickness shall be considered for payment purpose. |
| 39 | M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed. |
| 40 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed. |
| 41 | Material & labour for Galvanized iron tubing, 40mm bore medium grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of electric cable complete all as specified & as directed.Note :- Excavation & earthwork shall be measured & paid for separately. |
| 42 | Supply and fixing sheet metal enclosure, distribution board, double door type, suitable for fixing MCCBs/MCBs, TPN with 200 Amps rated copper bus bar, 4 way, 415 Volts, suitable for MCBs fitted, flushed in wall, fixed, complete all as specified and as directed.Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 43 | Subtotal (Total of Schedule \"A\" Section-VII) |