| 1 | RMO of IEI & fans, DG Set, Fire Extinguishers, CCTV camera, EPBAX system, Submersible P/set, Water coolers, RO, Desert coolers, A/C at office complex & staff quater at Paschim VIhar per inventory, terms and conditions attached by deploying the following staff:-i) Wireman Gr-I – 1 No. per day in general shift & as and when required.ii) Khallasi - 1 No. per day in general shift & as and when required.iii)Operator Gr.-II -1 No. per day in general shift & as and when required. |
| 2 | Supplying & replacement of following accessories/items i/c connection, installation, commissioning, testing etc. in all respect complete as required.2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 3 | 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 4 | 4 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 5 | S.P. 5/6 amps, one way switch, piano type ISI marked. |
| 6 | S.P. 15/16 amps, one way switch, piano type ISI marked. |
| 7 | 6 pin 15/16 & 5/6 ampssocket outlet, piano type ISI marked. |
| 8 | S.P. 5/6 amps, one way modular switch, ISI marked. |
| 9 | S.P. 15/16 amps, one way modular switch, ISI marked. |
| 10 | 6 pin 15/16 amps modular socket outlet, ISI marked. |
| 11 | 3 pin 5/6 amps modular socket outlet, ISI marked. |
| 12 | Stepped type Modular Fan regulator (1 module). |
| 13 | Stepped type Fan regulator (1 module) piano type. |
| 14 | Bell push, piano type. |
| 15 | Pvc batten 25x16mm. |
| 16 | 6 amps. to 32 amps. ratings , SP MCB, “C” curve, 10 KA breaking capacity. |
| 17 | 32 amps, DP MCB, “C” curve, 10 KA breaking capacity. |
| 18 | 100 Amp FP MCCB, 30kA breaking capacity. |
| 19 | 63Amps, DP MCB \"C\" curve 10 KA breaking capacity. |
| 20 | 25 mm dia pvc conduit. |
| 21 | buzzer bell. |
| 22 | 3 pin, 5/6 ampssocket outlet, piano type ISI marked. |
| 23 | 16 amp 3 pin plug top. |
| 24 | 6 amp 3 pin plug top. |
| 25 | Pvc flexible conduit 25mm. |
| 26 | Remote control wireless call bell. |
| 27 | Supplying & replacement of suitable size of phenolic laminated sheet 3mm thick cover in front etc. as reqd. i/c cutting for switches / socket, fixing of piano type switch, connection testing etc. as required. |
| 28 | Rewiring for circuit/sub main wiring along with earth wire with the following sizes FRLS PVC insulated copper conductor, single core cable in Existing surface/recessed steelconduit i/c testing and commissioningas reqd.(a)2x1.5 sq. mm + 1x1.5 sq mm earth wire. |
| 29 | (b)2x4 sq.mm +1x4 sq.mm earth wire. |
| 30 | (c) 2x10 sq.mm+1x6 sq.mm earth wire. |
| 31 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 32 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 33 | Supplying and replacement following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door. |
| 34 | LED Batten light (System lumen efficacy >105<120lm/Watt)Supplying, installation, testing & commissioning of LED surface mounted Batten light of following body material and construction as per IS:10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating volatge AC 140-24 volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10% P.F.> 0.95, IP-20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000 K/ 4000K/ 5700K/6000K/6500K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be relevant BIS standard and trade mark certificate (T.C.). Manufacturer Word Mark/Name Engraved/Embossing/Screen printing on housing complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >105<120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90OC). CRCA sheet body (thickness > 0.50mm)a) 18-22 watt |
| 35 | Repairing, rewinding & servicing of 1 HP single phase burnt out self priming monoblock pump set and refixing the same i/c labour cahrges connection testing, commissioning etc required. |
| 36 | Servicing of window/Split type air conditioners of 1.5/2 ton capacity i/c cleaning with chemical of condenser coil, evaporator coil, lubrication & washing of complete A.C. with front grill and replacement of air filter Pads, re-installation Of Air Conditioner in the position etc. as required. |
| 37 | Servicing of water cooler 100/120 ltrs. Capacity oiling of fan, cleaning of base plate with chemical and cleaning of water tank, and painting etc. complete as required i/c TDS value got checked by TDS meter and submitting the TDSvalue certificate. |
| 38 | Supplying and replacement ofthe following suitable parts of water coolers 100/120 ltr./ air conditioners 1.5/2 ton i/c connection, testing etc. as required.(a) Running capacitor |
| 39 | (b) Starting capacitor. |
| 40 | (c) Overload protector. |
| 41 | (d) Thermostate. |
| 42 | (e) Fan motor. |
| 43 | (f) Compressor. |
| 44 | (g) Charging of refrigerant gas. |
| 45 | Supplying and replacement with regulator cooler kit(fan motor) suitable for 18”/20” size desert cooler i/c dismantling of existing desert cooler kit(fan), connection, testing etc. complete as required. |
| 46 | Supplying and replacement of 18\" x 20\" desert cooler body having water tank made out of 20 SWG MS sheetwith front grill, openable type side covers made out not less than 24 SWG suitable for 18\"/20\" sweep dia motor, selector switch, front grill one set wooden wool pads, 1/2 \" distribution pipe, one plug top 15 amp and 3 core round wire 1.5 sq.mm. & PVC flexible pipe.i/c testing connection etc required. |
| 47 | Supplying and replacement of wood wool pad set (set of 3 pieces) with steel wire jail, suitable for 18”/20” desert cooler i/c disposing the existing pad, cleaning of water tank complete etc. as required. |
| 48 | Supplying and replacement of Submersible pump set suitable for 18”/20” desert cooler with 1mtr, wire i/c dismantling refixing, connection, testing etc complete as required. |
| 49 | Supplying & replacement of following capacity of capacitor in the existing desert cooler/fan i/c connection, testing etc complete as required.a) 4MFD |
| 50 | b) 3.15 MFD |
| 51 | Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos., canopies, shackle kit, safety rope, copper winding, steel/AI body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including saferty pin, nut bolts, washers, temperature rise = 75 degree C (max.) insulation resistance more than 2 mega ohm, suitbale for 230 V, 50 Hz, single phase AC Ceiling Fan complaint to IS 374:2019 fan supply, earhting etc. complete as req.a) 1200 mm, service value > 5.1 CM/Min/Watt, air delivery 130 CM/Min. |
| 52 | Supplying and replacement of 300 mmsweep size exhaust fan with complete in all respect with louvers suitable for single phase 230 volt,50 Hz AC supply i/c connection, testing etc. complete as required. |
| 53 | Supplying and replacement of 300 mmsweep size wall fan with complete in all respec with louvers suitable for single phase 230 volt,50 Hz AC supply i/c connection, testing etc. complete as required. |
| 54 | Supplying & replacement ofM.S angle iron cooler stand having four legs andheight approx 80-100 cm (upto window of room) & length, breath according to cooler body Size having 18\"/20\"i/c fixing, testing,Connectionetc required. |
| 55 | Dismantlingthe existing damaged /burn out ceiling fan of 1200 mm sweep and rewinding the same with copper winding and replacement of ball bearing etc. and fixing the ceiling fan i/c connection,testing complete as required. |
| 56 | Lowering of submersible pump set in the existingbore with G.I. pipes i/c replacement of existing nuts & bolts, connections of delivery line, valves cable jointing, testing etc. completed as reqd. |
| 57 | Lifting of submersible pump sets along with G.I. pipes and accessories i/c dismantling of pump set from delivery line etc. complete as reqd. |
| 58 | Supplying & replacement of suitable sizepolycarbonated combined junction box i/c providing & fixing 6 pin 5/6 & 15/16 amp socket outlet & 15/16 piano type switch, connections etc. complete as required. |
| 59 | Supplying & replacement of suitable sizepolycarbonated double combined junction box i/c providing & fixing 2 no. 6 pin 5/6 & 15/16 amp socket outlet & 2 no. 15/16 piano type switch, connections etc. complete as required. |
| 60 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).CRCA Sheet Body (Thickness ≥ 0.50 mm)36 watt |
| 61 | Repairing, rewinding & servicingof 5 HP submersible motor pump set (Single phase) i/c refixing the delivery line with the pump sets, painting, connection, dismantling & testing etc. complete as required. |
| 62 | Servicing of 50 KVA D.G Set of Ashoka Leyland Make i/c replacement of lubrication oil, mobil oil, air filter, oil filter, coolant in radiator, diesel filter, battery terminal etc. complete as required. |
| 63 | Supplying of following sizes of XLPE insulated of 1.1 KV Grade Al. cond. armoured power cable including laying as per site requirement with clamping and saddling, connection, testing etc. as required.a)3.5 x35 sq. mm. |
| 64 | Supplying and replacement of water cooler of 60 ltr. Per hour coolingcapacity,storage capacity 120 ltr i/c Stainless steel tank, high energy efficient compressor, installation ,testing, commissioning etc. complete as required. |
| 65 | Supplying and replacement of 50 ltr/hr. commercialRo system potable water purifier,fully automatic shutoff function automatically switched off the machine when water tank get full complete as required , i/c installation, testing,commissioning, connection with existing water cooler. |
| 66 | Supplying and installation of 1 No. inverter having capacity minimum 1650 VA,suitable for double battery capacity minimum 140AH i/c supplying of 2 Nos. battery having capacity minimum 140 AH with suitable size trolley (Double battery inverter combo with trolley) i/c installation, testing & commissioning of new inverter and battery etc. as required. |
| 67 | Supplying of high speed diesel for operation of DG set i/c cartage, storage, filling and arrangement of minimum 200 ltrs capacity tank at sitein tank etc. complete as required. |