| Sl. No. | Item Description |
| 1 | Excavation mechanically (using excavators like JCB /Poclain/with bucket) in all types of soil, including all type of debris, road surface, murrum, soft rockfor foundations, wall, columns, plinth beams, basement, raft, ducts, trenches, underground sumps, septic tanks, soak well including shoring and strutting, bailing out water/pumping off water if required, removing and stacking or Disposing simultaneously the excavated soilanywhere outside ACTREC Campus and/or spreading soils in layers for site development. All complete as per specification and as directed by the Engineer-in charge. upto 3 m Depth. |
| 2 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two coats of paint after scrapping and removing old paint as per the instruction of engineer incharge. |
| 3 | Installation and removal of Temporary Barricading of PPGI sheet with structural steel support outside the gate till the work is completed. This includes all the work in progress signages and fluorescent tape. |
| 4 | Providing and fixing of heavy duty speed breakers on existing road with specifications as below.Body material : Synthetic rubberSize : 350mm X 250mm X 50mmLoad capacity : 70 TonnesFull UV Stabilized colours (No colour fading)Heavy metal fastener bolts (For tough grip)Prismatic Reflector studded (better night visibility)Interlocking system for longer life spanAll installations must have a warranty period of 3 years |
| 5 | Providing and fixing end caps to speed breaker. All installations must have a warranty period of 3 years |
| 6 | Dry stone rubble soling/pitching of 150 mm to 250mm size shall be approved quality, hard, free from cracks, durable, preferably black trap. Rubble shall be laid on leveled base close to give compact, surface. If base is not properly leveledsame will have to be done without any extra cost. Voids in the joints shall be filled with selected chips. A sample of paving shall be prepared and got approved before proceeding ahead. After stones are laid with thickness of 200mm and packed with chips, sandshall be spread and watered to fill remaining voids. Sandshall be allowed to go into joints till final packing is obtained. Rate quoted shall be for materials, labour, watering, leveling site, before paving, consolidating etc. complete. |
| 7 | Providing and laying in position ready mixed M20 grade plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, including the cost of centering, scaffolding, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineerin-charge. |
| 8 | Structural Steel work including MS Post and frame for partition, doors and Post: Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer & paint of approved colour, including welding and bolted with special shaped washers etc. complete. |
| 9 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material anywhere in ACTREC campus as per direction of Engineer-in-charge |
| 10 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. :25 mm nominal dia Pipes |
| 11 | Providing and fixing brass ball valve with all fixtures as per the instruction of Engineer incharge. - 25mm dia |
| 12 | Granite Cladding: Providing and laying Polished Granite stone flooring in required design and patterns on compound wall, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. :Polished Granite stone slab of all colour and texture |
| 13 | Providing and fixing Stainless Steel Signage in any language as specified in the tender and as per the drawing provided including cost of transportation and fitting . The Letters shall be \" TATA MEMORIAL CENTRE ADVANCED CENTRE FOR TREATMENT RESEARCH & EDUCATION IN CANCERKHARGHAR, NAVI MUMBAI\" |
| 14 | Providing and fixing Stainless Steel LOGO of ACTREC, TMC and DAE in any language as specified in the tender and as per the drawing provided including cost of transportation and fitting . |
| 15 | Providing and fixing LOGO of ACTREC on the ACP Panel. |
| 16 | Providing and fixing Stainless Steel for \" ENTRANCE ONLY\" or \"EXIT ONLY\" in any language or dual language as specified in the tender and as per the drawing provided including cost of transportation and fitting . |
| 17 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M30 grade with minimum cement content of 370 kg /cum |
| 18 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/ 125 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 19 | External Plastering: 20mm thick cement Plaster of mix 1:4 (1 cement: 4 fine sand) on rubble stone masonry as per the instruction of Engineer incharge. |
| 20 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including curtain wall system of 4mm thick matching existing ACP Panel or approved colour and makefixing over aluminium frame of 50mm x 25mm thick in grid form including cutting bending, ACP to required size and shape, fixing on Aluminium frame with weatherproof Silicon sealant and finishing the groove with black colour sealant as per manufacturer’s specification complete all inclusive of wastage, labour, shifting, transportation etc.as directed and instructed by Engineer incharge. The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant,backer rods etc all complete as per the instruction of Engineer incharge. Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design |
| 21 | Extra for using Hydraulic cranes, Lift to reach required height to complete the ACP Panel including removing damaged panels and replacing with new ACP of required size and shape complete as directed and instructed. |
| 22 | Providing & fixing 16mm thick multi wall bendable polycarbonate sheet of min weight of 3250 gms/sq. Meter, withextruded UV Protected (co. Test report shall be submitted) with special anti-glare protection to prevent glare and sun streaks, with vertical standing seam at both sides sun streaks, with vertical standing seam at both sides of panels, wielding or gluing of up stands or standing panels shall have a grip-lock double tooth locking mechanism to ensure maximum uplift capability. Panel ends shall be closed with additional End cap of Aluminium U-profile (anodized/powered coated) The work shall be fitted on existing MS Structure perpendicular to direction of sheet with purine spacing as specified by manufacturer ofas approved and directed by Engineer in-charge. Colour of Sheet will be Opal weight /Green/brown or other colured as approvedThe rate shall include cost of all scaffolding equipments, hardware, wastage etc working at all levels and heights. |
| 23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 24 | Preparation of Lawn and landscaping for planting on ground:Transporting and disposing of bad soil and debris into a suitable place out of the centre at this own cost. Filling the excavated areas by red soil (including the cost of red garden soil) for desire level, spreading of red garden soil to the required thickness .All over the area, mixing, rough dressing of area, spreading of 5cm thick layer of manure (including the cost of manure) and mixing properly with soil consolidation with water, fine dressing with preparation of beds by maintaining proper level and slope. |
| 25 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). This is including 2 coat primer and 2 coat external painting work for the kerb stone with approved colour. |
| 26 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 27 | Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) - in approved colour |
| 28 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 29 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 30 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.l. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design: With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 31 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe |
| 32 | Pruning of tree with all statutory permission as required and as per the instruction of Engineer incharge |
| 33 | CONCRETE BREAKING: Breaking of the existing concrete/brickwork by chiselling at all level including scaffolding and staging and the work shall be carried out so as to cause minimum inconvenience to hospital activity including cost of all material, labour, tools etc. carting away the debris out of hospital premises all complete as specified and directed. Rates also includes core cutting in concrete |
| 34 | Providing and fixing P.V.C. Rainwater pipes of mentioned outer diameter and having wall thickness of 2.2 to 2.7mm confirming to I.S.13592-1992 including proper rain water receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall afixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer incharge etc. complete.- 160 mm Dia |
| 35 | Precast GRC designer Jaali with Frame structure as per the 3D design |
| 36 | COMPUTER TABLE: Providing making & supplying computer table made out fo 19mm commercial ply for table top, mounted on the verticalside fo 19mm commercial ply and cabinet made out of19mm commercial ply for sides, shelves & shutters makingconcealed monitor arrangement by providing 8mm thick clear glass on table top of required size with edge polishas shown in drawing drawer and ready madekey board drawerwith heavy sliding channels with powder coated handle for shutter,cable manager drawers all edges shall be lippedwith 6mm thick T.W. lipping patti. All exposed faces shouldbe 1.5mm thk laminate of approved colour and non laminated area should be french polished inclu. cost of other materialslabor etc. as per drawing and as specified and directedby Engineer-In-Charge. Computer Table with all inner surface with 1mm thk approved laminate. |
| 37 | WOODEN CABINETProviding & fixing cabinet made up of 19 mm. Commercialply of approved make for top, bottom, sides & shelves &8mm commercial ply approved make for back side Door shutter made up of 19mm thick commercial ply andouter surfaces and top of shelves for open type cabine shouldbe laminated with 1.5mm thick approved plastic laminatesheet of required colour including all brass fittings such ashinges, tower bolts, ball catches, stopper, handle, kNosbs as per shown in drawing or approved by Engineer-In-Charge etc.and all exposed edges lipping with 6mm Thick T.W. lipping patti.locking arrangement with Godrej multipurposelock etc. allcomplete as specified & directed by Engineer-In-Charge. Openable type with angle support and laminate of approved colour on all sides and inside as per the instruction of Engineer incharge. |
| 38 | Providing and fixing portable cabin having two European style water closet and sink arrangement alongwith 500 liter sintex tank on roof. The size of porta cabin shall be 25 feet * 12 feet in dimension. Doors to all rooms to be provided as per the instruction of Engineer incharge. The top of porta cabin shall have manglorian type tiles on a sloping roof. |
| 39 | Electrical |
| 40 | POWER CABLES FOR DISTRIBUTION BOARD Allworks are SITC works |
| 41 | Supply, installation ,testing & commissioning the following cable on wall/floor/ceiling/structure member or on cable trays or down through PVC pipes, using MS spacers and GI saddles, cable clamp etc. complete in all respect. Cable, conforming to IS: 1554/Part 1/1998, XLPE, Aluminium stranded conductor, armoured, 1100 V class |
| 42 | Supplying,erecting &terminating FRXLPE insulated, galvanised steel formedwire armoured(strip)cable,1100 V 3.5 core 50 sq.mm.aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 43 | SITC of cable gland 50sqmmdouble compression type including black PVC shroud on gland |
| 44 | SITC of 50sqmm lugs aluminium type |
| 45 | SITC of 25sqmm lug aluminium type |
| 46 | EARTHING |
| 47 | SITC of Hot Dipped GI Earth Plate Electrode 600 x 600 x 6.3 mm earth station 2.5 mtr below the ground level --- Same as above-- as per drawing & specifications complete with all required materials like coke/charcoal, salts , brass nut bolts & washers, watering arrangement, GU pipe 25 mm pipe (B class) concrete/brick chamber, heavy duty cast iron cover plate & excavation in ground, refilling& removing of excess earth within a radius of 500 mtr.etc. scope also includes dewatering, shoring, & consolidation etc. |
| 48 | SITC GI Strip 25 x 3 mm including all fixing accessories |
| 49 | GI wire 8 SWG, (1 Run) |
| 50 | POWER DISTRIBUTION BOARD |
| 51 | Providing & erecting 4 PoleMCCB,415V, upto100A, rated short-circuit breaking capacity 25 kA(Ics=100% ofIcu),adjustable thermal(overload) setting andfixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel. |
| 52 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 100/300 mAsensitivitywithearthleakagetrip indicationcompleteasper specification no. SW-RCCB. |
| 53 | Supplying, erecting & marking SP MCB 6A to 32A, C-series with ratedshort - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB |
| 54 | Supplying & erecting triplepole andneutraldistribution board12 way(TPNDB),for mounting mentioned incomer and outgoingcables feeders with door, 1.2mm thickness outdoor stand mounted , IP67 Protection providedOutdoor type double doorincluding DGitigal 24 Hrs timerand all type fixing arrangements rain canopy , and MS angle foundation support , glands for incoming and outgoing cables Provision for voltmeters, ammeters, and KWH meters, often digital, to monitor supply parameters. , R Y B and ON OFF Trip Indication for incoming MCCBcomplete with tagging and as directed by EIC ES |
| 55 | Supplying and fixing following ratings 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles including metal enclosure box , earthing and fixing accessories with connections,Testing and commissioning etc. as required. As per technical specifications in tender. |
| 56 | Supplying, erecting & marking DP MCB 6A to 32A, C-serieswith ratedshort - circuitbreaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB |
| 57 | SITC of DP MCB Enclosure box Metal type IP 67 with waterproof PVC Glands |
| 58 | SITC of SPN DB 12way 63 A DP MCB Incomer , Outgoing SP MCB 16AMP 10 Nos all MCB c curve type including all fixing accessories |
| 59 | CABLING FOR LIGHTING |
| 60 | SITC of 3 x 6 sq. mm copper conductor armoured cable |
| 61 | Supplying, erecting& terminating FR XLPEinsulated,galvanisedsteel wire armoured(round)cable,1100 V 3 core2.5 sq.mm.aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/ALat all juncture waterproof connector box to be places where lighting connection / tapping is provided |
| 62 | Supplying, erecting& terminating FR XLPEinsulated,galvanisedsteel wire armoured(round)cable,1100 V 3 core1.5 sq.mm.aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe at all juncture waterproof connector box to be places where lighting connection / tapping is provided |
| 63 | SITC of Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVCconduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireincluding PVC conduicts , bends , and all fixing accessories( Rate for one mtr circuit i.e.3 x 2.5sqmm wire) for power points |
| 64 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable including surface/ recessed medium class PVC conduit asrequired. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire FOR POWER POINTS |
| 65 | LIGHTING |
| 66 | LED Flood Light, powder coated pressure die cast aluminum(System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powdercoated pressure die cast aluminum body with built in or separate driveras per the requirement with Driver efficiency >85%, Input voltage: Inputvoltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMCas per CISPR -15 , lenses for beam angle 30 deg-120deg as per theapplication and the project requirement deg., suitable tilt able fitting, life time(LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolationIES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (Asper ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximumpower consumption should not more than the specified rating and Fixtureshall be of relevant BIS standard complete in all respect i/c connectionswith 1.5 sq mm FRLS, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test reportfrom NABL lab for all testing required for LED fixtures as per BIS shallbe submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink ofaluminum housing such that LED junction temperature shall not rise above90°C) |
| 67 | 100 WATT IP 67 |
| 68 | 60/ 70 WATT IP 67 |
| 69 | Supplying and erecting Gate/ gardenlightfittingwith 300mm dia.glass bowl suitable for upto 12W to 15 wattLEDLampIP 67 , Light fixture of 12w to 15 w is also includeddecorative type roun d/ square pole design as approved by EIC ES |
| 70 | SITC of LED Down lighter22 watt square type (System lumen efficacy ≥ 105 < 120lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed/ surfaceDown lighter (Round/ square/ Rectangular) SMD type of following bodymaterial with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI>80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below5%), life time (LED,Driver & electrical circuitary), of minimum 50000Burning Hours with 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) <3, Maximum powerconsumption should not more than the specified rating and Fixture shallbe confirming to relevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing Complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. System lumen efficacy ≥105and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for alltesting required for LED fixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LEDjunction temperature shall not rise above 90°C) |
| 71 | Power Pointsfor inside cabin |
| 72 | Supplying and fixing following size/ modules, PVC / GI box alongwith modular base & cover plate for modular switches in surface orrecess etc. as required. • All the power socket tagging to be provided , PVC tags to be provided.• All the power sockets inside and power panel insidewiring ferruling to be done as instructed by EIC ES |
| 73 | 3 Module |
| 74 | 6 Module |
| 75 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. |
| 76 | Modular switch 6A/16A |
| 77 | Modular Socket 6A/16A |
| 78 | Boom Barrier Electro mechnaical boom barrier as per tender specifications up to 6 mtr |
| 79 | Supplying andlaying (including excavationof suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugated pipes(DWC) ofHDPE for enclosing cable below ground/road surface, complete. |
| 80 | STREET LIGHT POLE |
| 81 | Installation of 7 Mtr. hot dip galvanised Octagonal street light pole with 1.5M long single arm bracket, suitable for 44 m/sec wind speed with suitable foundation bolts, bakelite with 1 no. 6A SP MCB and stud type terminal block/connector box of approved make suitable for terminating cable up to 4Cx16 sqmm size ACTREC Will provide 7 Mtr pole agency has to shift the pole to gate no 3 and installation to be done. |
| 82 | Casting of new foundation for 7 Mtr. poles of above type inlcuding excavation of pole pit. The concrete mix for RCC foundation of Octagonal pole shall be M20. The scope shall also include grouting of foundation bolts including curing& provision of DWC HDPE pipe for passage the cable and finishing the surface (Composite). |
| 83 | LED Street light fixture 90 WATT IP 67 , powder coated pressure die castaluminum body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LEDfixture powder coated pressure die cast aluminum body with driver asper the requirement with Driver efficiency >85%, Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade,internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driverefficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMCAs per CISPR -15, lenses for beam angle as per IESNA type I/II/III asper the width of the road and the project requirement., suitable to fit in up to65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard DeviationColor Matching) <5, Maximum power consumption should not more thanthe specified rating and Fixture shall be of relevant BIS standard completein all respect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Wattoutput . LM79 & LM80 Test report from NABL lab for all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C).1.12 |
| 84 | SITC of double arm for the7 Mtr pole the arm design to be matching with existigngpole and material |
| 85 | SITC of3 Mtr. Decorativepost top type pole having spigot on top of pole, suitable for 44 m/sec wind speed with foundation bolts, bakelite with 1 no. 6A SP MCB and stud type terminal block/connector box of approved make suitable for terminating cable up to 4Cx16 sqmm size |
| 86 | Casting of new foundation for 3 Mtr. poles of above type inlcuding excavation of pole pit. The concrete mix for RCC foundation of Octagonal pole shall be M20. The scope shall also include grouting of foundation bolts including curing& provision of DWC HDPE pipe for passage the cable and finishing the surface (Composite). |
| 87 | Supply ,Installation,Testing & Commisioning of45 Watt LED or equivalent Post top Light having pressure die-cast aluminimum housing with Coated with epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint, suitable to following features. - Luminaires suitable with base plate and fitted on a existing site Pole.-In built electronic LEDdriver,-High Transmisivity diffuser>85%,-IP-65/67,-Warm White-THD<20%-High Efficacy gretaer than or equal to 100 lm/watt,-Provide Uniform low glare lighting ,-CRI-70,-Operatable voltage - 220-240 V,50 Hz, PF>0.9,-Colour Temperature-4000K ,5000K. |
| 88 | Supply, fabrication & installation of MS angle/ Strip/ plate / rod/ channel etc. as per given design duly painted with 2 coats of red oxide & 2 coats of enamel paint of approved shade all as per the instruction of EIC. 20 mm dia 1.5 long |
| 89 | Supply, laying, testing & commissioning of 1.1 KV AC grade of 4corex 16sq. mm Aluminiumarmoured Conductor cableconforming to IS: 1554/Part 1/1998, XLPE,1100 V class PVC insulated ISI markarmored, bright annealed Aluminium conductor cable in ground at 900 mmback filling & re-instatement, consolidation & removal of excess earth with in a radius of 500 mtr including clamping , saddling , cable route tag , laying of cable tiles / bricks, sand fillingthrough out under ground route. for sports lighting |
| 90 | 16sqmm cable gland double compression type |
| 91 | 16sqmm lug aliminium type |
| 92 | Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16SWG GIsheet of 150mmwidth& 75 mm height complete with necessary coupler plates & hardware. |
| 93 | SITC of 3 x 2.5 sq. mm PVC flexible cable copper |
| 94 | CCTV and Telephone Technical Specification attached. |
| 95 | SITC of 5 MP IP Bullet Camera with(2mm to 4mm at lower end) & (9mm to 15mm at higher end) auto focus motorized optical zoom or better vandal proof metal body 1/2.8” or better , IR 50 Mtr or morePoE Support, NAS Storage,SD Card(256GB or better ) Support, , In-built Microphone True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming Cyber Security Features: STQC Certified including all required fixing accessories , and as per technical specificatons mentioned in tender documents |
| 96 | SITC of 32 Channel NVR with 4K Support as per technical specifications , 32 IP Channel Inputs; 4K HDMI, 1/1 Audio I/O and 2/1 Alarm I/O , 4 SATA HDDor better Support (18TB ore moreCapacity per Slot, Hard Disk Not Included) including video management software for client PCincluding all required fixing accessories , and as per technical specificatons mentioned in tender documents |
| 97 | SITC of 512 GBSD card for camera as per technical specifications in tender documents |
| 98 | 18TB Sata Enterprise Hard disk |
| 99 | SITC of fully loaded RJ-45 24 port Patch Panel with tool-less keystone jacks having the compliance / Certifications for ISO 9001:2015 & ROHSincluding all required fixing accessories , and as per technical specificatons mentioned in tender documents |
| 100 | SITC of 24 Port 24 x 10/100/1000BASE-T PoE,PoE Network Switch ,including all required fixing accessories , and as per technical specificatons mentioned in tender documents |
| 101 | SITC of IT rack -19\" Wall mounted rack 15U(double section)with acrylic glass door with the accessories -[Two Fan position tray with two 90 CFM fans(AC 230V),3 Horizontal cable manager- 3nos, AC power panel strip with 5 X 5 AMP /15Ampsockets ,fuse and on/off switch, 1 packet mounting hardwareincluding all required fixing accessories , and as per technical specificatons mentioned in tender documents |
| 102 | Supplying, installation, testing and commissioning of Media Convertor Lc type 1 gig1000BASE-T to 1000BASE-LX Media Converter: SM, Max distance 15km. 1 RJ-45&1 fiber port (LC) |
| 103 | SITC of SFP Module 10Gfiber support10km |
| 104 | SITC of PATCHCORD, SM (OS2), DUPLEX LC-LC, PC TYPE, 3M, LSZH |
| 105 | SITC of PATCHCORD, SM (OS2), DUPLEX LC-LC, PC TYPE, 10M, LSZH |
| 106 | Supplying and fixing (rack dressing) 2 meter length, UTP Patch cord of Cat 6 type in position having the compliance / Certifications for ISO 9001:2015 & ROHS. |
| 107 | SITC ofCAT-6Armoured cable cable throughcasing-capping, PVC conduit for camera to switch connectivity. Cat6 cable series consists of 100- Ohm impedance, 4-pair UTP cables for horizontal installations in local area networks (LANs). All cables meet and exceed Category 6/Class E requirements in TIA 568-C.2, and ISO/IEC11801. These cables are UL Listed and UL & ETL verified. |
| 108 | SITC of HDPE Pipe 32mm for armoured Cat 6 cable laying |
| 109 | SITC of Accessories & Connecotrs RJ45 & DC Pins Pair |
| 110 | SITC of PVC Box 4 x 4 weather proof for camera Outdoor type IP 67 |
| 111 | SITC of HDMI cable 10MTr |
| 112 | SITC of metal Bracket for Camera installationas per site requirements |
| 113 | Supply of single phase ,230 volt , 50Hz ,2KVA ONLINE UPS system with battery bank, battery rack , connectionn links , having minimum 30 min. power back up. |
| 114 | SITC of client workstation: Intel Core i7 14th Gen Processor16 GB Ram, 512 GB SSD + 1 TB Seagate SATA HDD8 GB Graphic Card, Wired Keyboard & Mouse23.8” or more Monitor, 2 Port Serial Card, 1 Port Parallel CardWindows 11 Pro Preloaded, 1 Yrs Warranty by OEM as per technical specifications mentioned in Tender. |
| 115 | SITC of 43\" LED 4K UHD smart LED TV with VGA input ,2HDMI port with Wallmount Stand, with remote and other accessories as per site installation and as directed by OIC-EIC Resolution: 4K Ultra HD (3840x2160) | Refresh Rate: 60 hertzConnectivity: Wi-Fi (Built-in) | 3 HDMI portse | 1 USB ports to connect hard drives and other USB devices | eARC | Bluetooth 5.0 | Optical | EthernetSound: 20 Watts Output | 2.0 Ch Speaker | AI Sound (Virtual Surround 5.1 up-mix) | Auto Volume Levelling | Bluetooth Surround ReadySmart TV Features: AI ThinQ & WebOS 22 with User Profilesα5 Gen5 AI Processor 4K | Display: 4K Ultra HD LED Display | 4K Upscaler | AI Brightness Control |
| 116 | Configuration and integration charges for New CCTV system, and installation of software in work station. Providing View at Santi Sadan Security. |
| 117 | Fiber cable |
| 118 | SITC of 12 Core outside Optical Fibre cable corrugated steel tape armoured loose tube, gely filled, 9/125 micron single mode OS2 specification in trench cable tray/ clamping on wall with suitable clamps, saddles bolts, etc. through HDPE pipe including connections/terminations in distribution box (LIU\"s) in rack with connectors and couplers having the compliance/certifications for ISO 9001:2015 & ROHS. |
| 119 | SITC of Slicing of fiber core |
| 120 | SITC of 12 Fibre LC Type SM fully Loaded LIU with pigtail OS2 Lazrspeed fully loaded fibre tray which includes adaptors, pigtails, splice protectors, etc. for the terminations of 12 core singh mode fibre cablehaving the compliance/certifications for ISO 9001:2015 & ROHS |
| 121 | Supplying andlaying (including excavationof suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugated pipes(DWC) ofHDPE for enclosing cable below ground/road surface, complete. |
| 122 | SITC of Cat 6 type I/O with RJ 45 socket with Box, faceplate and fixing screws, having the compliance/certifications for ISO 9001:2015 & ROHS |
| 123 | IT and Networking |
| 124 | SITC of IT rack -19\" Wall mounted Rack 15U(double section 600 x 600)with acrylic glass door with the accessories -[Two Fan position tray with two 90 CFM fans(AC 230V),3 Horizontal cable manager- 3nos, AC power panel strip with 5 X 5 AMP /15Ampsockets ,fuse and on/off switch, 4 packet (Pack of 10) mounting hardware. |
| 125 | SITC of CAT 6 fully loaded 24 port Patch Panel with cable management bar at rear side keystone jacks having the comliance with punch down tool and compliance / Certifications for ISO 9001:2015 & ROHS |
| 126 | SITC of Cat 6 type I/O with RJ 45 socket with Box, faceplate and fixing screws, having the compliance/certifications for ISO 9001:2015 & ROHS |
| 127 | SITC of CAT 6 LAN cable for DATAincluding 25mm PVC Conduit Supply ,Installation,Testing & Commisioning of of UTP 23 AWG 4 pair CAT 6 LAN Cableto TIA/ EIA 568 B.2.1.in the surface/ recessed steel/ PVC conduit as required. All the cabe to be connected in IT rack with RJ 45 connector. |
| 128 | Supplying and fixing (rack dressing) 1 meter length, UTP Patch cord of Cat 6 type in position having the compliance / Certifications for ISO 9001:2015 & ROHS. |
| 129 | Supplying and fixing (rack dressing) 2 meter length, UTP Patch cord of Cat 6 type in position having the compliance / Certifications for ISO 9001:2015 & ROHS. |
| 130 | SITC of 24 Port 10/100/1000 Gigabyte PoE Network Switch ,24 Nos RJ 45 ,10/100/1000 PoE++ ports and 4 SFP+ 10G ports (RJ-45 interface andSFP+ port ), power cords and mounting accessories and equivalent to technical specification mentioned in tender documents. |
| 131 | SFP Module 10Gfiber campatible with supplied switch supports 10km |
| 132 | PATCHCORD, SM (OS2), DUPLEX LC-LC, PC TYPE, 3M, LSZH |
| 133 | SITC of 12 Core Armored Optical Fibre cable corrugated steel tape armoured loose tube, gely filled, 9/125 micron single mode OS2 specification in trench cable tray/ clamping on wall with suitable clamps, saddles bolts, etc. through HDPE pipe including connections/terminations in distribution box (LIU\"s) in rack with connectors and couplers having the compliance/certifications for ISO 9001:2015 & ROHS. |
| 134 | Supplying andlaying (including excavationof suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugated pipes(DWC) ofHDPE for enclosing cable below ground/road surface, complete. |
| 135 | SITC of 12 Fibre LC to LC Duplex Type SM fully Loaded LIU with pigtail OS2 Lazrspeed fully loaded fibre tray which includes adaptors, pigtails, splice protectors, etc. for the terminations of 12 core single mode fibre cablehaving the compliance/certifications for ISO 9001:2015 & ROHS |
| 136 | Splicing of fiber core |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy