| 1 | UP- GRADATION OF ELITE HOSTEL AND ALLIED ELECTRICAL WORKS AT SAI NSRC LUCKNOW |
| 2 | Providing and fixing powder coated aluminium work (minimumthickness of powder coating 50 micron) consisting of tee/ anglesections, of approved make conforming to IS : 733 in frames of falseceiling including aluminium angle cleats with necessary C.P. brass/stainless steel sunk screws, aluminium perimeter angles fixed towall with stainless steel rawl plugs @ 450 mm centre to centre andfixing the frame work to G.I. level adjusting hangers 6 mm dia. withnecessary cadmium plated machine screws all complete as perapproved architectural drawings and direction of the Engineer-incharge(level adjusting hangers, ceiling cleats and expansion holdfasteners to be paid for separately). |
| 3 | Providing and fixing false ceiling at all heights with integral densifiedcalcium silicate reinforced with fibre and natural filler false ceilingtiles of Size 595x595mm of approved texture, design and patternsas per CPWD Specification 2019, to be laid in true horizontal levelsuspended on inter-locking metal T-Grid of hot dipped galvanisediron section of 0.33mmthick (galvanized @ 120 grams per sqmincluding both sides)comprising of main-T runners of size 24x38mm of length 3000 mm,cross - T of size 24x32 mm of length1200 mm and secondary intermediate cross-T of size 24x32 mmof length 600mm to formgrid module of size 600 x 600 mm,suspended from ceiling usinggalvanised mild steel items (galvanizing@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm diafully threaded hanger rod upto 1000 mm length and L-shape leveladjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require,fixed with Glavanised iron perimeter wall angle or size 24x24x0.40mm of length 3000 mm to be fixed on periphey wall / partition withthe help of plastic rawl plugs at 450mm center to center and 40 mmlong dry wall S.S screws. The workshall be carried out as perspecifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick Tegular edged lightweight calciumsliciate false ceiling tiles |
| 4 | Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shadeof the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 5 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm includingpointing the joints with white cement and matching pigment etc.,complete. |
| 6 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm |
| 7 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. |
| 8 | Providing and fixing fly proof galvanized M.S. wire gauge to windowsand clerestory windows using wire gauge with average width of aperture1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 9 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 10 | Making connection of drain or sewer line with existing manholeincluding breaking into and making good the walls, floors with cementconcrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) cement plastered on both sideswith cement mortar 1:3 (1 cement : 3 coarse sand), finished with afloating coat of neat cement and making necessary channels forthe drain etc. complete :For pipes 100 to 250 mm diameter |
| 11 | Dismantling stone slab flooring laid in cement mortar includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead. |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 13 | 12 mm cement plaster finished with a floating coat of neat cement ofmix :1:3 (1 cement: 3 fine sand) |
| 14 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm)on existing cement paint surface |
| 16 | Removing white or colour wash by scrapping and sand papering andpreparing the surface smooth including necessary repairs to scratchesetc. complete |
| 17 | Providing and fixing panelling or panelling and glazing in panelled orpanelled and glazed shutters for doors, windows and clerestory windows(Area of opening for panel inserts excluding portion inside grooves orrebates to be measured). Panelling for panelled or panelled and glazedshutters 25 mm to 40 mm thick : Ply wood 7 ply, 9 mm thick, Decorative plywood one side decorative veneerand commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type |
| 18 | Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item): With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm) |
| 19 | Supplying , Installation, Testing and Commissioning of AirCooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU toODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase ACsupply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year OriginalEquipment Manufacturer (OEM) warranty both compressorand Printed Circuit Board (PCB). Must comply : Electricalcable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as perCPWD specification and IS : 1391 Part II 2023. The systemshall be able to operate up to 50 0C (out door ambienttemperature). Inverter Type - Cooling only: 1.5 TR with 5 Star BEE Rating (makemitsubishi,ogeneral,or equivalent) |
| 20 | Supplying, Installation, Testing and Commissioning of AirCooled Cassette type Air conditioners complete with Indoorunit(IDU), Out door unit (ODU), R-32/R410A/R-407 GreenRefrigerant, wireless Remote, inbuilt drain pump, suitablefor 400/230V, 50 Hz ,1 /3 phase AC supply, includingsurface / concealed copper Refrigerant piping withinsulation (closed cell elastomeric nitrile rubber tubular pipesection) upto 5.5 Mtr (IDU to ODU), copper power andcontrol cable upto 5.5 Mtr (IDU to ODU) including drainpipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filteration & ventilation offollowing capacity with Scroll/rotary compressor with min 5year Original Equipment Manufacturer (OEM) warrantyboth compressor and Printed Circuit Board (PCB) asspecified. The system shall be able to deliver 100% of therated capacity as per relevant IS Code. The lab testingreports as per IS: 1391 shall be submitted from NationalAccreditation Board for Testing and CalibrationLaboratories (NABL) accredited as per InternationalElectrotechnical Commission (IEC) 17025standards/Central Power Research Institute (CPRI)/Electrical Research and Development Association(ERDA)with Original Equipment Manufacturer (OEM) etc.complete as per CPWD specification and as per IS: 1391as required.Inverter Type- Cooling only : 2.5 TR with 5 Star BEE Rating (makemitsubishi,ogeneral,or equivalent) |
| 21 | Supply & installation of LED surface light (with frame) 60X60cm of 30W capacity all complete as per direction of EIC (make: philips,Wipro or equivalent). |
| 22 | Supplying, Installation, Testing and Commissioning of centralized exhaust system comprising of following systems1. Kitchen Exhaust & Fresh Air Exhaust Fan4000 CFM 35mm SP(Qty-1 nos)2.SITC of Fresh Air System for Kitchen (Qty-1 nos)3. Fabricated GI Duct SITC of Factory Fabricated GSS Sheet meta rectangular Ducting complete with Neoprene rubber gasket, Elbows, splitter dampers , vanes , hangers, supports etc as per approved drawing and spectication of the following sheet thickness complete as require.(Qty-550 Sqft.)4. Grilles SITC of Powder coated Aluminium extruded Grills (Qty-07 nos)5. Exhaust Hood SITC of fabricated Stainless Steel SS-304 Exhaust Hood with Baffe Filter (Qty-18 nos)including Installation Charges &Freight Charges all complete as per direction of EIC(make: Daikin, airvex or equivalent) |
| 23 | Un-Installation of existing window/split/cassate AC including all accessories & fittings and repairing of walls & closing the openning with requisite materials as per specifications with seepage treatment all complete as per direction of EIC. |