| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 6 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 8 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Finishing walls with water proofing cement paint of required shade : |
| 10 | New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 12 | Two or more coats on new work |
| 13 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litreof approved brand andmmanufacture to give an even shade : |
| 14 | Old work (one or more coats) |
| 15 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 16 | 1:3 (1 cement: 3 fine sand) |
| 17 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 18 | Of area 3 sq. metres and below |
| 19 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 20 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 21 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 22 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 23 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 24 | 6 mm thick Cement fiber board as per IS: 14862 |
| 25 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 26 | Electric resistance or induction butt welded tubes |
| 27 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 28 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 29 | Two or more coats on new work |
| 30 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work |
| 31 | 15 mm dia nominal bore |
| 32 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 33 | 25 to 40 mm nominal bore |
| 34 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 35 | 25 mm nominal bore |
| 36 | Providing and fixing brass bib cock of approved quality : |
| 37 | 15 mm nominal bore |
| 38 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 39 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. |
| 40 | Size of Tile 600x600 mm |
| 41 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: |
| 42 | White glazed fire clay kitchen sink of size 600x450x 250 mm |
| 43 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 44 | Semi rigid pipe |
| 45 | 32 mm dia |
| 46 | Providing and laying Hollow cement concrete black walling 150 mm thick consisting of hollow block of size 400x150x200mm of mix 1:3:6 (1:cement:3 pulverised sand: 6 graded stone aggregates of 10 mm normal size) laid in cement martar 1:6(1cement: 6 sand). |
| 47 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Palverised sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick stone aggregate 40 mm nominal size, well rammed and consolidated and grouted with Pulverised sand including necessary excavation, levelling & dressing & finishing the top smooth. |
| 48 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 49 | Providing and fixing panelling of panelling and glazing in panelled of panelled and liazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick: |