| 1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 2 | G.S. Sheet |
| 3 | Asbestos Cement sheet |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 5 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 7 | For thickness of tiles 10 mm to 25 mm |
| 8 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per directionof Engineer - in - charge. |
| 9 | Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) |
| 10 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 11 | All kinds of soil. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 13 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from naturalsources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) |
| 14 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 16 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 18 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 19 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 20 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 22 | Foundations, footings, bases of columns, etc. for mass concrete |
| 23 | Suspended floors, roofs, landings, balconies and access platform |
| 24 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 25 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 26 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete. |
| 27 | Hot finished welded type tubes |
| 28 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 29 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 30 | Two or more coats on new work |
| 31 | Providing and fixing bolts including nuts and washers complete. |
| 32 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section. |
| 33 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 34 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigmentto match the shade of the tiles, including rubbing and polishing complete,on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : |
| 35 | Light shade pigment using white cement |
| 36 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 37 | Size of Tile 600x600 mm |
| 38 | 12 mm cement plaster of mix : |
| 39 | 1:4 (1 cement: 4 fine sand) |
| 40 | White washing with lime to give an even shade : |
| 41 | New work (three or more coats) |
| 42 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 43 | Granite stone slab colour black, Cherry/Ruby red |
| 44 | Area of slab over 0.50 sqm |
| 45 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 46 | Two or more coats on new work |
| 47 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : |
| 48 | New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 49 | Finishing walls with water proofing cement paint of required shade : |
| 50 | New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 51 | Providing and laying hollow cement concrete hollow walling 200mm thick consistiing of hollow block of size 400mm x 200mm x 200mm of mix 1:3:6 (1 cement : 3 Pulverised sand : 6 graded stone aggregate 10 mm nominal & sown size laid in cement mortar 1:6 (1 Cement : 6 Pulverised sand) upto-floor-V level. |
| 52 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick stone aggregate 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 53 | Providing and fixing in position eave or facia board with 20 mm thick non asbestos plain sheet of HILUX Board and 30cm wide including nailing etc. Complete as per the direction of Engineer-in-charge. |