| 1 | Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | CEMENT CONCRETE 1:5:10 [One Cement, Five sand and Ten hard broken stone jelly] using 40 mm gauge hard broken granite stone jelly for FOUNDATION including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification. |
| 3 | Refilling with Excavated Earth other than sand with an initial head load of 100 mts. and depositing the earth in places shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification |
| 4 | Supplying and filling in foundation, basement, etc with filling GRAVEL in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 5 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.. |
| 6 | Brick work using using Country Bricks of size 8-3/4\" x 4-1/4\" X2-3/4\" in Cement Mortar 1:6 (One cement and six crushed stone sand) including curing neat finishing, etc., complete complying with standard specifiction. |
| 7 | For Foundation and basement |
| 8 | For Superstructure in Ground floor |
| 9 | For Superstructure in First floor |
| 10 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as COLUMN FOOTINGS, COLUMN PEDESTALS, PLINTH BEAMS, BED BLOCK, GRADE BEAMS, STAIRCASE STEPS, etc., which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc., complete in all floors complying with standard specifcation. [Payment for centering shall be given after the concrete is laid]. |
| 11 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height For plane surfaces as detailed below , in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). |
| 12 | FOR PLANE SURFACES SUCH AS RCC FLOOR SLAB, ROOF SLAB, RECTANGULAR BEAMS, ELL BEAMS, LINTELS, LANDING WAIST SLAB, CONAPY SLABS BED BLOCKS etc., |
| 13 | FOR PLANE SURFACES SUCH AS RECTANGULAR OR SQUARE RCC COLUMNS TOP AND BOTTOM SLABS OF RCC BOXING TO WINDOWS RCC SUNSHADES etc., |
| 14 | Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 15 | For Foundation and basement |
| 16 | For Superstructure in Ground floor |
| 17 | For Superstructure in First floor |
| 18 | Supplying, fabricating and placing in position MILD STEEL / RIBBED TOR STEEL grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. [Contractor has to make his own arrangements for the supply of steel and binding wire] |
| 19 | Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly for DUMMY COLUMNS, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. |
| 20 | For Superstructure in First floor |
| 21 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. First Floor |
| 22 | Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 23 | PLASTERING with Cement Mortar 1:5 [One Cement and Five crushed stone sand], 12 mm thick in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 24 | SPECIAL CEILING PLASTERING and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 [One Cement and Three crushed stone sand] 10 mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. |
| 25 | Supplying and fixing in position best approved of BIS quality of 110mm dia PVC RAIN WATER DOWN FALL PIPES having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.110mm dia |
| 26 | Supplying and erecting pull and push type rolling shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc., ROLLING GRILLS (WITH ISI MONOGRAM) Gear operated (from 8 m2 to 12 m2 area) |
| 27 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) sliding Windows of casement type (open) of approved standard quality. The window should be of multi chambered sections with wall thickness of 2mm reinforced with hot dip galvanised to 125GSM and 100% corrosion free.Including vat and transportation charges etc., complete. |
| 28 | Fabrication, supply and fixing in position of \"N\" type ventilators using M.S. angle of size 25 x 25 x5 mm for frame and M.S. Flat of size 20 x 3 mm for fixing the weld mesh and using 25 x 22 x3 mm \"T\" section for frame glass. Special type of Hold fast welded to the frame of 45 degree inclined towards centre for wall and fxing the weldmesh 25mm square including cost of 3mm thick pinheaded glass panes for all panels and fixing the glass panels with necessary clips & putties with required bolts, nuts and washers and one coat of red oxide primer etc. including necessary dismantling, making holes in RCC columns, beams, masonry wherever necessary with power drill to the extend required and made good to the original conditions after fising as directed by the departmental officers. |
| 29 | Providing and Fixing Stainless Steel Hand rail made out of SS304 grade 50.80mm dia Stainless Steel tube of 1.60mm thick at required locations to a height of 1000mm from finished floor level welded to 38.30mm dia Stainless Steel tube post of 1.60mm thick as vertical at 100mm centre to centre with 3 Nos. of 25.40mm dia horizontal stainless steel tubes of 160mm thick in between as per details shown in the drawing and as directed. The rate shall include for grounding with concrete into necessary supporting arrangements of handrail verticals and in floor, welding the base cub of the post into slab reinforcement polishing, buffing and protecting the handrail surface etc., complete complying with standard specification and as directed by the departmental officers. |
| 30 | Manufacturing, supplying and fixing in position plain cement concrete precast pavement slab of size 450mm x 450mm of 50mm thick in Cement Concrete 1:2:4 (One cement, Two crushed stone sand and Four jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three Sand) to full depth of slab etc., complete complying with standard specification and as directed |
| 31 | Supplying and fixing with best approved quality fine polished Granite Stone Slabs for work table of size 1200 x 600 of 18 / 20mm thick of Jet Black with machine cut edges laid over a cement mortar 1:2 (one cement and two sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width joints and pointing the joints with white cement mixed with matching colouring pigments etc., the granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 32 | Supplying and fixing M.S. Grill of approved design for open courtyard, grill, grill works to doors and window opeings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification |
| 33 | Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 34 | Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., complete complying with standard specification. |
| 35 | Painting two coats of newly plastered wall surface with ready mixed Interior plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 36 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 37 | Nosing the granite for kitchen table top with requied shape and design with hand machine etc., complete complying with standard specification and as directed by the departmental officers. |
| 38 | Providing ANTI-TERMITE treatment to soil adjacent under building foundation, plinth periphery of the building by application of chemicals of ISI 63613 part I to IV in stages to suit the progress of work as per the detailed specification as below. Including breaking of termite mounds, making holes with clow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. |
| 39 | Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete. |
| 40 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End (DATA A) |
| 41 | Supply and fixing of Havells LED Low Bay 50W Fitting with MS clamp set with Bolt and nut and to be suspended with ss chain 32mm width with end Hooks with PVC unsheathered Copper Leads from Terminal to the fitting. (DATA B) |
| 42 | Supply and fixing of single box type 4\"20 W LED fitting with TW round blocks on wall or celling with PVC unsheathed Copper leads from terminals to the fitting. (DATA -C) |
| 43 | Supply and fixing of 1200mm (48\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp (SD 110) |
| 44 | Supply and fixing of 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 390) |
| 45 | Supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting . (SD 447) |
| 46 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40 A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Lower End (SD 515) |
| 47 | Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1\"x1/8\"copper flat) on TW plank of size 375mmx300mmx19mm with supporting TW reepers of 1\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40Amp 30 MA Double Pole RCD / RCCB (Lower End) with suitable necessary connection |
| 48 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion.(SD 337) |
| 49 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class \"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD 211) |
| 50 | Supply and Run of 1 of No.8 SWG copper wire for earth connection (SD 370) |
| 51 | Supply and Run of 2 of 10 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade on 7/20 GI wire for service connection mains (SD 364) |
| 52 | Supply and Run of 2 of 10 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in 25mm dia GI pipe (class B ) suitably bent at both ends with necessary angle iron upright and end support for service connection mains (SD 365) |
| 53 | GST 18% Please Enable Macros to View BoQ information |