| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified all as specified and directed. |
| 3 | S & F prepainted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof, fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F Steel work as in tubular section for post, purlins etc including special shaped washer, angle cleat, holdfast, gusset plate etc., complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240cut or notched forming holes, without any attachment including drilling, fitting, riveting and or welding or connecting with bolts and nuts (including rivet or nut and bolts) providing and fitting angle cleats Gusset plates etc also for welding plumbing, truing up and fixing complete as directed by Engr-in-Charge. |
| 5 | S&F 1.25mm mild steel, plain, black sheet in ridges, hips, valley gutters, drip and straight flashings with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required |
| 6 | M&L for applying two coats of synthetic enamel paint on newsteelsurfaces of any description, over 10 cm in width or girth over a coat of red oxide primer complete all as specified and directed by Engr -in-Charge. |
| 7 | M&L for Brick work with sub class `B\" bricks straight or curved on plan exceeding 6 metremean radiusbuilt in cement mortar 1:6, complete all as specified and directed by the Engineer-in-Charge. |
| 8 | M&L 15mm thick rendering on fair faces of wall in CM 1:6 onbrick/concrete surfaceand finishing the surface even and smooth with out using extra cement. |
| 9 | M&L 15mm thick rendering on fair faces of wall in CM 1:4 onbrick/concrete surfaceand finishing the surface even and smooth with out using extra cement. |
| 10 | M&L 150mm thick hardcore of gauge broken boulders & stone n.exc 63mm, deposited,spread and levelled in layers n.exc 15 cm thick, watered and rammed in two layers to a true surface complete all as specified and directed by Engr -in-Charge. |
| 11 | M&L for plain cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregates ) infoundation filling and mass concrete, complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for Vitrified Ceramic tiles (Light shade/ Double charged/ Ultra charged) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured, laid over and including 15mm thick screed bed or bedding layer in cement mortar1:6, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 13 | M&L Chequered cement concrete tiles 20cmx20cmx25mm thick as in path etc. set and jointed with grey cement and pigments as in floors and over and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and directed. |
| 14 | M&L 25mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregates as in levelling course of flooring complete all as specified and directed. |
| 15 | M&L for cement concrete 1:2:4 type B-1using 20 mm graded stone aggregate as in copings, weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by the Engineer-in-Charge. |
| 16 | M&L for preparing new plastered surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces complete all as specified and directed. |
| 17 | M&L 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregates) as in plinth protection/path finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 18 | S&F TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 19 | S&F TMT steel bars 5mm dia and over, upto and including 10mm dia as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 20 | Use and waste of formwork for rough finished surfaces of concrete to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintel beam, cantilevers, shelves including supports, overhangs etc, complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L for RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) nominal mix as in tie beams, gable beams, cantilevers, bressummers, lintels over 1.5 mtr clear span,complete all as specified and directed. |
| 22 | S&F Anodised aluminium frame (powder coated minimum thickness of powder coating 50 micron) for doors, windows, partition wall with one or more rebates including joining cleat for fixing, rubber packing, anodised aluminium snap on beading for fixing glass panes in frame etc complete all as specified and directed. |
| 23 | S&F Anodised aluminium(powder coated minimum thickness of powder coating 50 micron) door shutters, powder coated of any colour aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, anodised aluminum snap beading screws etc. frame will be fixed to wall ,complete all as specified and directed by the Engineer-in-Charge. |
| 24 | S&F Galvanisedmild steel wire cloth, 0.56mm nominal dia of wire and avgerage width of aperature 1.18 mm fixed with tinned tacks, or galvanised wire staples. |
| 25 | S&F 5mm thick , plain sheet glass, selected quality and glazing with oil putty in squares exc 0.5 sqm in each pane complete |
| 26 | S&F brass mortice lock, vertical type 4 levers, size 100 mm,complete all as specified and directed by the Engineer-in-Charge. |
| 27 | S&F door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed, complete all as specifiedand as directed by the Engineer-in-Charge. |
| 28 | S&F GI frame work size of grid 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofit at approx 900 mm centre to centre with GI cleat and steel expansion fasterner with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips acress the intermediate channel at 457mm centre to cnetre including hangers 6mm dia.GI (upto 1200mm length) adjusting level fixed tp roof slabs by means of ceiling cleats made out ofGI flat 40 x 3mm size 60mm ling and expansion hold fasterner 12.5mm dia 40mm long including 12mm thick gypsum board of size 600 x 600mm as in ceiling fixed on GI/ Aluminium frame work, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Returning, filling in trenches including spreading levelling, watering well, ramming in layers n.exc 25cm in soft/loose soil (from available soil) all as specified and directed by Engr-in-Charge. |
| 30 | Removing excavated material ( soils )exc 250 mtrbut n exc 500m depositing where directed complete all as specified and directed. |
| 31 | Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete with fittings and fixtures such as switches,ceiling rose ,pendents, regulators, socket, lamp holders brackets,bulk head fitting, etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and also making good distrubed surfaces of wall,floors etc, complete all as specifiedand directed by the Engineer-in-Charge. |
| 32 | M&L for concealed point wiring for one light point / fan point controlled by one switch using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) wiring with FRLSH cable PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and including not less than 2mm thick PVC conduit with all accessories and earth continuity connected to common earth duly accommodate modular box surface/ flush type with modular white cover plate with frame for mounting fittings such as switches, sockets, fan regulators etc complete all as specifiedand directed by the Engineer-in-Charge. |
| 33 | All as per Srl item No 32 here in before butfor one light/ fan point controlled by one No. switch 5 Amps and wiring (non-concealed) with FRLS , Multistranded copper conductor cables in PVC Casing and caping.Note : Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc. |
| 34 | All as per Srl item No 33 here in before but for one bell point controlled by one No. bell push.Note : Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc. |
| 35 | All as per Srl item No 32 here in before but for one multi pin socket outlet on same board, complete all as specified and as directed by the Engineer-in-Charge. |
| 36 | All as per Srl item No 33 here in before but for one multi pin socket outlet on the sameboard, complete all as specified and as directed by the Engineer-in-Charge.Note: Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc. |
| 37 | All as per Srl item No 32 here in before but for one multi pin socket outlet,5/6 Amp, controlled by one No. one way switch on independent board, complete all as specified and as directed by the Engineer-in-Charge. |
| 38 | All as per Srl item No 33 here in before but for one multi pin socket outlet,5/6 Amp, controlled by one No. one way switch on independent board, complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | All as per serial item No 32 here-in-before ,but for one socketout let 15 Amp on the independent board with 2.5 sqmm copper conductor multistranded PVC insulated and unsheathed electric cable 1100 volts(ISI MARKED) including PVC insulated and unsheathedelectric cable 1100 volts, 2.5 sqmm copper stranded conductor as continuous earth wire connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. |
| 40 | All as per serial item No 33 here-in-before ,but for one socketout let 15 Amp on the independent board with 2.5 sqmm copper conductor multistranded PVC insulated and unsheathed electric cable 1100 volts(ISI MARKED) including PVC insulated and unsheathedelectric cable 1100 volts, 2.5 sqmm copper stranded conductor as continuous earth wire connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. |
| 41 | S & F modular switch piano button flush type, single pole one way 6 amps complete all as specified as directed. |
| 42 | S & F modular socket 6A, 2/3 pin combined 2 module complete all as specified as directed. |
| 43 | S & F modular switch piano button flush type, single pole one way 16 amps complete all as specified as directed. |
| 44 | S & Fmodular socket 6A/16A, 2/3 pin combined 2 module complete all as specified as directed. |
| 45 | S&F ceiling rose surface bakelite 3 terminals 65 x 50mm complete all as specified and as directed by Engineer-in-Charge. |
| 46 | S&F Fan step modular regulator, 1 module, complete all as specified and directed. |
| 47 | S & Fmodular bell push 6A, 1 module, one way, complete all as specified as directed. |
| 48 | S & F White cover plate with frame, 2 module, complete all as specified. |
| 49 | S & F White cover plate with frame, 3 module, complete all as specified. |
| 50 | S & F White cover plate with frame, 4 module, complete all as specified. |
| 51 | S & F White cover plate with frame, 8 module, complete all as specified. |
| 52 | S & F Metal flush box 1/2 module, complete all as specified. |
| 53 | S & F Metal flush box 3 module, complete all as specified. |
| 54 | S & F Metal flush box 4 module, complete all as specified. |
| 55 | S & F Metal flush box 8 module, complete all as specified. |
| 56 | S&F LEDLights fitting 20 watt, 220V, AC Decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 57 | Supply and fixing in replacement of angular type Lamp holder PVC polycarbonate type with back plate including Lamp 9 Watt complete all as specified. |
| 58 | Supply and fixing sheet metal enclosure for MCB\"s, double door SPN 240 volts, 8 way with 200 amps rated bus bar, neutral link, earth barand making good to disturbed surfaces of floors, walls etc, complete all as directed. |
| 59 | S&F MCB SPN, 40-63 Amps, 240 volts, 10 kA rupturing capacity, \"C\" curve type, complete all as specified and as directed by the Engineer-in-Charge. |
| 60 | S&F MCB SP, 6 -32 Amps, 240 volts, 10 kA rupturing capacity, \"C\" curve type, complete all as specified and as directed by the Engineer-in-Charge. |
| 61 | Supply and laying, testing and commissioning of cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cable( heavy duty) 1100 Volts grade with stranded aluminuim conductor of size 16 Sqmm 2 core. |
| 62 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep soft/loose soil and getting out for laying of cables etc of any size. |
| 63 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding1.5 mtr above the starting point. |
| 64 | Material and labour for old size bricks well burnt as covering to under ground cables class `B`, laid dry flat over the cables with width equal to length of cables complete all as specified. |
| 65 | S&L dry river sand as cable cushioning in trenches 5cm below the cable & 18 cm above the cable punned to the thickness of 13cm and covering complete all as directed.Note:- Punned thicknesss of sand shall be measured. |
| 66 | M & L for earthingcomplete with galvanized steel earth plate electrode60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanised iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover. |
| 67 | Note:-An amount of Rs. Rs 1,212.00 on account of credit schdule for Sch \"A\" Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. |