| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out Soft/loose soil, returning,filling in and ramming earthor broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface. |
| 2 | M&L for cement concreteType C-2, 1:3:6, ( 40 mm graded stone agg ) infoundation filling and mass concrete, all as specified and directed by Engr-in-Charge. |
| 3 | S&F Steel work as in tubular section for Post, Purline etc including special shaped washer , angle cleat, holdfast, gussete plate etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240cut or notched forming holes, without any attachment including drilling, fitting, riveting and or welding or connecting with bolts and nuts (incl rivet or nut and bolts) providing and fitting angle cleats Gussete plates etc also for welding plumbing, truing up and fixing complete as directed by Engr-in-Charge. |
| 4 | S&F Fe 410-W (Gde-E-250) quality-A Roof trusses ( framed), trused purlins , crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified. |
| 5 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws as specified |
| 6 | painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 7 | M&L Preparation of new untrerated surface and applyingtwo coats of Synthetic enamel painting on newsteelSurfaces of any description ,over 10 cm in width orgirth over a coat of red oxide all as specified and directed by Engr -in-Charge. |
| 8 | M&L 100 mm thick cement concrete type D-2,1:4:8(40 mm graded aggregate) as in sub base all as specified and directed by Engr -in-Charge. |
| 9 | M & L 25 mm thickSand filling under floors or in foundations including watering and consolidation |
| 10 | M&L machine pressed precast coloured concrete interlocking paver blocksany shape and size confirming of IS 15658: 2006 of 60mm thick , M-35 laid and jointed with grey cement and pigment. |
| 11 | Material and labour for cement concrete 1:2:4 Type B-1using 20 mm graded stone aggregate as in copings, weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by the Engineer-in-Charge. |
| 12 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and gatting out Soft/loose soil all as specified and directed by Engr -in-Charge. |
| 13 | M&L 150mm thick hardcore of guage brocken boulders & stone n.exe 63mm, deposited,spread and levelled in layers n.exe 15 cm thick,watered and rammed in two layers a true surface all as specified and directed by Engr -in-Charge. |
| 14 | M&L 100 mm thick PCC 1:2:4 type B2(40mm graded stone aggregate) as in floors laid in panels, rough finished Finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 15 | Removing excavated material ( soils )exc 250 mtrbut n exc 500m depositing where direced complete all as specified and directed. |
| 16 | Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade \"A\" thickness of concrete slab in 100 mm complete all as specified and directed. |
| 17 | M&L for Forming Contraction (Dummy)joints 50 mm deep x 10mm wide, filled with sealing compound® grade A incl bituminous filler complete all as specified and directed. |
| 18 | Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade \"A\" |
| 19 | S & F for5mm thick PVC sheet fillet of width10 mm for wall paneling inclusive offixing on to wall to make PVC Frame asper specification and drawing. |
| 20 | S & F Solid PVC Wall Lining consisting of5mm thick Plain colour PVC sheetinclusive of solvent cement and fixing atsite on PVC frame as per specificationsand drawing |
| 21 | Supply laying testing and comminssioning ofXLPE insulatedLT U/G cable heavy duty , 1100 volts grade, galvanizedwire armoured and PVC sheathed with multistranded aluminium conductor of size2 core6 Sqmm laid in trenches or fixed on wall (including saddle clip) or drawn through pipes complete |
| 22 | Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. |
| 23 | Supply & lay 50 mm bore HDPE pipe PN -10 in protection of cable at road crossing /hard standing, fixed with clamps as per site requirement etc all as specified anddirected. |
| 24 | Supply and fixingceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm sizecomplete all as specified & directed. |
| 25 | Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring. |
| 26 | Supply and fixing sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 4 way with 200 amp copper bus bar,and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified directed. |
| 27 | Supply and fixing MCB, SP, AC, 240 volts of 06 to 32 Amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. |
| 28 | Supply and fixing MCB, SPN, AC, 240 volts of 40 Amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. |
| 29 | Supply and fixing LED flood light 70 watts230 volt, AC outdoor type with thermal management in multiple optics and all assy duly prewired and pressure die cast aluminium housing,heat resistant tough glass with frame,IP 66 protection and with impact and corrosion resistant complete with driver and lamp included 10KV SPD ans better optic for uniform distribution complete all as specifed and as directed. |
| 30 | Supply and fixing LED flood light 100 watts230 volt, AC outdoor type with thermal management in multiple optics and all assy duly prewired and pressure die cast aluminium housing,heat resistant tough glass with frame,IP 66 protection and with impact and corrosion resistant complete with driver and lamp included 10KV SPD ans better optic for uniform distribution complete all as specifed and as directed. |
| 31 | Taking down and refixing hanger high bay lights towards roof with adjustant to birdnet up to15 mtr height with support of hydra machine / required T & P completeall as specified and asdirected |
| 32 | S & F LED flood light 350 Watt IP 65 fixing in hanger up to 15 mtr hight with support of hydra machine/required T& P along with all necessary fixing arrangement complete all as specified and as directed. |
| 33 | S & F LED flood light 400 Watt IP 65 fixing in hanger up to 15 mtr hight with support of hydra machine/Rrequired T & P along with all necessary fixing arrangement complete all as specified and as directed. |
| 34 | M&L for sub main wiring using two run single core 4 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 vots grade, ISI mrked complete with PVC casing caping accessories like bends tees etc and PVC insulatd copper cable 4 Sqmm for earth ire and connecting to earth dolly |
| 35 | M&L for sub main wiring using two run single core 6 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 vots grade, ISI mrked complete with PVC casing caping accessories like bends tees etc and PVC insulatd copper cable 6 Sqmm for earth wire and connecting to earth dolly. |
| 36 | Supply and fixingVTPNMCCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCCB as incommer complete all as specified and directed. |
| 37 | Supply and fixing MCB DB 8 way SPN sheet metal enclosure 240 volts, 50 Hz, with IP-43 protection, double door withsuitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified and directed. |
| 38 | S & F MCCB 100 Amp 25 KA 4pole suitable for VTPN DB complete all as specified and as directed. |
| 39 | S & F MCB SP 6 to 32 ampC curve complete all as specified and as directed. |
| 40 | S & F MCB SPN 40 AmpC curve complete all as specified and as directed. |
| 41 | Supply & Lay XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100V grade with stranded aluminium conductor of size 35 Sq mm 4 corecomplate all as specified and directed. |
| 42 | S & F conical shape canopy made fromMS sheet 4 mm thick having size suitable for fixing at existinghigh bay light to avoid sitting of birds completeall as specified and as directed. |
| 43 | Note for all items :- If any item gets repeated in this schedule, the lowest rate quoted for those same items by the L-1 bidder shall be considered for payment and decision of Accepting Officer i.e. GE(AF) Baroda in this regard shall be final and binding. |