| 1 | Taking down cementplaster on brickor stone masonrysurfaces of walls etc includingrakingout joints, hackingfor key, scrubbingdown with water etc complete all as specified and directed. |
| 2 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, for ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling. Complete all as specified and directed. |
| 3 | M & L for Pre-cast cement concrete block masonry (1:2:4) Type B1 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar (1:4) Complete all as specified and directed. |
| 4 | M&L rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 5 | M&L rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement mixed with intergral water proofing compound @ 2% by weight of cement (WPC measured and shall be paid separately) all as specified and as directed. |
| 6 | M&Lpreparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over one coat of primer with and including 3mm thick wall care putty (Birla white or equivalent) complete all as specified and directed. |
| 7 | M & L for two coats of cement base paint over a coat of primer with alkali resistant priming paint on newely plastered surfaces of wall including preparation of walls etc. Complete all as specified and directed. |
| 8 | M&L for three coats of white wash on new plastered surface including prepration of wall surface. Complete all as specified and directed. |
| 9 | M&L for preparation of old plastered/unplastered white washed surfaces of walls and applying one coat of white washing complete all as specified and as directed by Engr-in-charge. |
| 10 | M&L for preparation of old plastered/unplastered white washed surfaces of walls and applying two coat of white washing complete all as specified and as directed. |
| 11 | M&L for preparation of old distempered surfaces of walls and applying one coat of distemper oil emulsion white or tinted over a coat of primer complete all as specified and directed. |
| 12 | M&L for complete removal of the existing treatment on walls by scrapping and washing down with water including making good the surfaces and applying two coats of distemper oil emulsion over one coat of primer with and including wall care putty not less than 1 mm thick (one or more coat) complete all specified and directed. |
| 13 | M&L for preparation of old decorated surfaces of walls and applying one coats of cement based paint complete all as specified and directed. |
| 14 | M&L for complete removal of the existing treatment on walls by scrapping and washing down with water including making good the surfaces and applying two coats of cement base paint complete all as specified and directed. |
| 15 | M&L preparing old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete al as specified and directed. |
| 16 | M & L for preparing old painted steel and iron surfaces of any description over 10 cm width or girth including CGI sheet in roof etc and applying one coat of synthetic enamel paint complete al as specified and directed. |
| 17 | M&L preparing old painted steel and iron surfaces of any description over 10 cm width or girth including CGI sheet in roof etc and applying two coat of synthetic enamel paint over a coat of primer including complete removal of existing treatment complete al as specified and directed. |
| 18 | M&L for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high. Complete all as specified and directed. |
| 19 | M&L for complete removal of the existing treatment on walls by scrapping and washing down with water including making good the surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specifed and directed. |
| 20 | Supply only integral water proofing compound complete all as specified and as directed. |
| 21 | Taking down chowkhatsor frame exc 1.50 sqm but n.exc 4.00 Sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed. |
| 22 | S & F pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. Complete all as specified and directed. |
| 23 | S & F 35mm thick factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply, 2nd class HW rail & style, the size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressed treated. |
| 24 | M & L for two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer on steel surfaces of any description, over 10 cm in width or girth, not otherwise described including preparation of new surfaces complete all as specified and directed. |
| 25 | M & L for two coats of synthetic enamel paint over a coat of pink primer on wood based surfaces of any description, over 10 cm in width or girth, not otherwise described including preparation of new surfaces complete all as specified and directed. |
| 26 | S & F in repair 6mm thick transparent / translucent /opaque acrylic sheet as in door, window & ventilators. Complete all as specified and directed. |
| 27 | Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/slabs/blanketsany thickness, including cover fillets complete all as specified and as directed. |
| 28 | Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work) all as specified and directed. |
| 29 | Dismantling timber fillets, rails, posts rafters purlins etc under 40 Sqcm in section fixed, in any position (framed work) complete all as specified and directed. |
| 30 | S&F GI frame work of size 605 x 605 mm, for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equalflanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 31 | S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 32 | S&F 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium /G.I./M.S as per specification and drawing. |
| 33 | S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 34 | S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 35 | Taking down Chowkhats or frames not exc 1.5 sq. m each but with shutters (without taking off shutters from the frame) of PVC door with shutter complete all as specified & directed. |
| 36 | S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. Complete all as specified and directed. |
| 37 | S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and Prelam PVC sheet for top rail , lock rail and bottom rail on either side and as gap insert for top rail and bottom rail , panelling of both side Prelam PVC sheet to be fitted in the MS framewelded/ sealed to the stiles and rails with suitable PVC sheet beading , and jointed together with solvent cement in the frame at site as per specification. Complete all as specified and directed. |
| 38 | S & F Butt hinges, 100 mm size, heavy weight, cold rolled mild steel, and fixed. Complete all as specified and directed. |
| 39 | S & F Mild steel barrel tower bolts 200 mm, stove enamelled black, with bright bolt and fixed. Complete all as specified and directed. |
| 40 | S & F 150mm long aluminium handle cost type anodised. Complete all as specified and directed. |
| 41 | S&F of 250 mm long aluminium alloy, anodised slidingdoor bolts with haps staple(bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed completeall as specified and directed. |
| 42 | S&F in repair sheet glass, ordinary quality 3mm thick, glazing with oil putty not exceeding 0.50 Sqm in each pane, complete all as specified and directed. |
| 43 | S & F in repairfor 600x450mm bovelled edge mirror of selected quality glass mounted on 6mm thick AC building board of commercial ply wood and fixed to wooden plugs with chromium plated brass secrews and cup washers including taking down. Complete all as specified and directed. |
| 44 | S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed inclding taking down. Complete all as specified and directed. |
| 45 | S & Fin repair Soap dish, any type, fixed to plugs with chromium plated brass screws. Complete all as specified and directed. |
| 46 | S & F in repair Vitrous China wash down water closet pan pedestal pattern white, inclusive of PVC seat cover white recess bottom type mild steel chromium plated or aluminium handing device andfixing \"P\" or \"S\" trap, connecting to union of flushing cistern and drain pipe complete all as specified and directed. |
| 47 | S & F in repair vitreous china squatting pan, Orissa pattern, size 580 x 440mm white, with itegral foot rests water closet complete includingprovision of lime concrete bedding. Complete all as specified and directed. |
| 48 | S&F in repairs 10 Ltr capacity PVC Valveless symphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including bracket and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as per specified and directed. |
| 49 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. Complete all as specified and directed |
| 50 | M & L forNon - skid Ceramic tiles 7 to8 mm thick area of eachtile exceeding 0.18 sqm but not exceeding 0.38 sqm, infloors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed. |
| 51 | M & L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surfaces of tile over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed. |
| 52 | M&L for Vitrified ceramic dark shade tiles 10 mm thick (Square/Rectangular) polished, area of each tile not exceeding 0.36 sqm, infloors etc, set and jointed in neat cement slurry and pointed with coloured cement to match over and incl 15mm thick screed bed in cm (1:6) in flooring complete all as specified and directed. |
| 53 | All as per item No.52 here in before but on vertical surfaces over and including 10 mm thick back coat in CM (1:4) complete all as specified and as directed. |
| 54 | Taking up or down 20mm dia steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 55 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 56 | S & F in repair 15mm dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 57 | S & F in repair 15 mm dia bib tap standard of PTMT fancy type high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms/20mm) complete all as specified and directed. |
| 58 | S & F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 59 | S & F in repair Vitreous China wash basin, flat back, size 550x400mm white, including waste pipe, 32mm dia chromium plated(CP) waste coupling chain and plug waste filling, union brackets, cutting for & plinning in ends of brackets or erecting stands complete all as specified and directed. |
| 60 | S & F in repair 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe compete all as specified and directed. |
| 61 | S & F in repair stop cock 15 mm bore cast copper alloyscrewed down high pressure fancy type, chromium plated with long shank and cup (concealed type) complete all as specified and directed. |
| 62 | S&F in repair brass 15mm dia CP basin mixer for mixing hot & cold water screwed down for iron pipe and fixed etc all as speified. |
| 63 | S & F in repair Vitreous China Urinal, Half stall type, white complete including providingand fixing plugs, bedding urinalagainst wall in cement mortar1:2, securing urinal to plugs withand including 60mm long brassscrews, pointing around urinalback in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushingcistern, trap and waste pipe) complete all as specified and directed. |
| 64 | S & F in repair urinal spreader of PTMT any colour to fixing with 15mm dia pipe (minimum weight 60 gms) complete all as specified and directed. |
| 65 | S & F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 66 | S&F in repair PVC (SWR) \"P\" trap 110 mm bore complete all as specified and directed. Complete all as specified and directed. |
| 67 | S&F in repair PVC (SWR) \"S\" trap 110 mm bore complete all as specified and directed. Complete all as specified and directed. |
| 68 | S&F in repair 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 69 | S & F in repair PVC (SWR) pipe 75mm bore single socketed in any length with rubber ring joint laid in trenches or in floor (ISI Marked ) complete all as specified and directed. |
| 70 | S & F in repair PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joint laid in trenches or in floor (ISI Marked) complete all as specified and directed. |
| 71 | S&F in repair PVC ( SWR ) bends 75 mm bore complete all as specified and directed. |
| 72 | S&F in repair PVC ( SWR ) bends 110 mm bore complete all as specified and directed. |
| 73 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws incl taking down existing old sheets complete all as specified and directed by Engr-in-Charge. |
| 74 | S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws inclding taking down existing old sheets complete all as specified and directed by Engr-in-Charge. |
| 75 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface. Complete all as specified and directed by Engr-in-Charge. |
| 76 | M&L for PCC (1:3:6) type C-2 (40mm grade aggregate) in foundation of post holes complete all as specified and directed. |
| 77 | S&F for structural steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etcconfirming to FE 410-W (Gde- E- 250) quality - A including dismanting existing oldstructural steel Complete all as specified and directed. |
| 78 | S & F structural steel work in tubular tresses, purlins including special shaped washer etc. compolete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 as in frame work for sun shade, roof, projection etc. including dismanting existing oldstructural steel complete all as specified and directed. |
| 79 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness(below or above ground level) complete all as specified and directed. |
| 80 | M&L 75mm thick PCC (1:3:6) type C-2 (Using 40 mm graded aggreate) as in floors & paving finished even & smooth without using extra cement complete all as specified and directed. |
| 81 | Dismantling boarding, anydescription, fixed in any position with screws complete all as specified and directed. |
| 82 | M & L for 3.2/3.3 mm thick Linoleum, Jaspe type, sealed down with an approved adhesive in floors including stretching, cutting and fitting including taking up or down existing linoleum flooring complete all as specified and directed. |
| 83 | S & F 18mm thick Plywood, grade BWP, type BB,fixed with screwsto angle iron frame work as in floors including taking up or down existing plywood flooring complete all as specified and directed. |
| 84 | Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment. |