|
| 1 | Supply of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size : 3.5 core x 120 sq.mm. Aluminium armoured Cable. |
| 2 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 3 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5 X 120 sq. mm (45mm) |
| 4 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 5 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A, 16 KA, TPMCCB |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire. |
| 7 | Supplying and fixing 63 A rating, 415 V, 10 kA, \"C\" curve,miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing andcommissioning etc. as required. Triple pole. |
| 8 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door. |
| 9 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100A |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq.mm + 1 X 2.5 sq. mm earth wire. |
| 12 | Supplying and fixing suitable size GI box / CPVC Box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 13 | Supplying and fixing suitable size GI box / CPVC Box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 14 | Supply and Fixing of 63 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (Havells / Anchor / L&T / Schneider / ISI / Branded) |
| 15 | Supply and Installation of 10 sq.mm. Single core copper cable with accessories. (Make : Finolex / KEI) |
| 16 | Supply and Installation of 600 x 600 x 3 mm Copper Plate Earthing with 25 x 5 mm (3 Meters) and 40 mm watering pipe with funnel 3 meter along with Charcoal, Salt and earthing with accessories and pit cover. |
| 17 | ESE Lightning ArresterSupply and Installation of Stormflash ESE lightning air terminal with the below technical parametersΔT - 60 Micro SecondsMETU lab tested as per NF C 17-102 (2011) standardHIZAL lab tested as per NF C 17-102 (2011) standard70 KA lightning impulse current tested20 Years manufacturing warrantyProtection Radius = 79 mtrs |
| 18 | Supply and Installaion of Optical Lightening Counter (6 Disgit) with IP 65 Protection |
| 19 | Supply and Installation of GI Support Mast 5 Meter with accessories |
| 20 | Supply, Laying and installation of 70 sq. Mm. Single core copper cable with accessories |
| 21 | Supply and Installation of 600 x 600 x 3 mm Copper Plate Earthing with 25 x 5 mm (3 Meters) and 40 mm watering pipe with funnel 3 meter alongiwth Charcoal, Salt and earthing with accessories and pit cover. |