Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface dressing n. exc 15 cm deep and getting out in any type of soil complete all as specified and directed. |
| 2 | Removing excavated materialn exc. 50m and depositing where directed at a level n exc 1.5mabove the starting point complete all as specified and directed. |
| 3 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes, pier holes, etc. but not exceeding 10 Sqm on planand getting out insoft/ loosesoil complete all as specified and directed. |
| 4 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5m in depth but not exceeding 3.0 m in depth; for foundations etc. or for shafts, well cess pits, manholes, pier holes, etc. but not exceeding 10 Sqm on planand getting out insoft/ loosesoil complete all as specified and directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick each layer in loose/soft soil complete all as specified and directed. |
| 6 | Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick each layer, spread, levelled and rammed including watering as required complete all as specified and directed. |
| 7 | M&L Plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations / mass concrete complete all as specified and directed. |
| 8 | M&L Treating the backfill in contact with foundation and at junction of wall and floor upto ground level at the rate of 7.5 litres of emulsionper square metre of vertical surface (as per IS:6313 Part-2, Fig-4) complete all as specified and directed |
| 9 | M&L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 10 | M&L Treating the soil under plinth protection at the rate of 5 litres of emulsionper square metre of surface area complete all as specified and directed |
| 11 | M&L Treating the soil along with external perimeter of building at the rate of 2.25 litres of emulsion per metre of the perimeter wall complete all as specified and directed |
| 12 | M&L forreinforced cement concrete Design mix M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams , plinth beams , base for coloumnsand mass concreteetc. complete all as specified and directed. |
| 13 | M&L forreinforced cement concrete Design mix M-25(using 20 mm graded stone aggregate) as incoloumns, pillars, piers, posts and struts etccomplete all as specified and directed. |
| 14 | M&L forreinforced cement concrete Design mix M-25 (using 20 mm graded stone aggregate) as in chajjas,etc. complete all as specified and directed. |
| 15 | M&L forreinforced cement concrete Design mix M-25 (using 20 mm graded stone aggregate) as in Roof beam, lintel band, cantilevers bressummers, lintels over 1.5m spanetc. complete all as specified and directed. |
| 16 | M&L forreinforced cement concrete Design mix M-25(using 20 mm graded stone aggregate) as in slab supported on walls ,beams, columns in floor , roof , landing complete all as specified and directed. |
| 17 | Use & waste of Formwork to sides of concrete, in foundations, footings,base ofcolumns & plinth beams, etc in flat for rough finshed surfaces of concrete complete all as specified and directed. |
| 18 | Use & waste of Form work to Columns, square/rectangular, rough finish surfaces of concrete complete all as specified and directed. |
| 19 | Use & waste of Formwork to soffits of suspended slab such as roof slab, floor slabs, landing and similar work; not exc 200mm thick complete all as specified and directed. |
| 20 | Use & waste ofFormwork to edges of concrete flats, treads, breaks in floors, window cills concrete railings, opening in concrete walls, floor and roofs slab n. exc 20 cm wide and sides of RCC/PCC bands in walls, exc 10cm and n.exc 20cm wide complete all as specified and directed. |
| 21 | Use & waste ofFormwork to chullah hoods, chajjas, troughs and similar items including edges comlete all as specified and directed. |
| 22 | Use & waste of formworkto sides and soffits of floor or roof beams, beam haunchings, lintel bands, cantilevers shelves incldng sup-ports, overhangs, etc comlete all as specified and directed. |
| 23 | M&Lfor mild steel TMT bars ,10mm dia and over, cut to length, bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 24 | M&Lfor mild steel TMT bars ,6 mmto 8 mm diaover, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 25 | M&Lfor mild steel TMT bars 5 mmand overuptoand including 10 mm dia , as in stirrups , spacers ,and binders, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 26 | M&L hard core of broken stone boulder of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 27 | M&L 75 mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate), finished even and smooth without using extra cement as in plinth protection including forming of joints 10mm wide and 75mm deep and joint filled with bitumin and sand mixture in 1:1 ratio complete all as specified and directed. |
| 28 | M&L for 75 mm thick PCC(1:4:8) type D-2, (using40 mm graded stone aggregate),as in sub base for floor, finished even and rough complete all as specified and directed. |
| 29 | M&L 25 mm thick cement concrete 1:2:4 Type B-0, (using 12.5 mm graded stone aggregate), as in levelling course complete all as specified and directed. |
| 30 | M&L Non-skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchh over and including 15 mm thick screed bed in CM 1:6 as in floors complete all as specified and directed. |
| 31 | Ditto- but tiles in vertical surfaces of wallset and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 32 | M&L non skid ceramic colouredtiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles, over & including screed bed or bedding layer 15 mm thick of cement mortar 1:4 complete all as specified and directed. |
| 33 | M&L forglazed ceramic coloured tiles in vertical surface 350mm x 250mm x 7mm/ 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed inwhite or colour cement to match, aid over and including rendering 10 mm thick on fair facesbrick work or concrete surface in cement plaster 1:4 complete all as specified and directed. |
| 34 | M&L for Brick work with sub class ‘B’bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed |
| 35 | M&L for Brick work with sub class `B\" bricks straight or curved on plan exc 6m mean radius, built in CM 1:4, in half brick thick wallscomplete all as specified and directed. |
| 36 | M&L, 15mm thick rendering on brick or stone/concrete any surfaces in cement mortar 1: 4 on mixed with WPC @ 0.4% by weight of cement, surface finished even and smooth withoutusing extra cement complete all as specified and directed.Note : WPC shall be measured & paid seperately. |
| 37 | Supply only integral liquid water proofing compound (ISI marked) complete all as specified anddirected. |
| 38 | M&L for 10 mm thick rendering in cement mortaron fair faces of brick work or concrete surfaces in cement mortar (1:6) and surface finishedeven and smooth, complete all as specified and directed. |
| 39 | M&L for 5 mm thick renderingin Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 40 | Preparation of new plaster surfaces of wall, and applying two coats of distemper oil emulsion over a coat of 1-2 mm wall putty & over a coat of alkali-resistant primming paintcomplete all as specified and directed. |
| 41 | M&L applying two coats of cement base paint, including preparation of newly plastered surface of walls complete all as specified and directed. |
| 42 | M&L Preparing new plastered surfaces of ceiling and applying three coats of white wash all as specified and directed. |
| 43 | S&F pressed steel frame of size 125mmx60mm for doors with one or more rebates including necessary fixing lungs and hinges, lock strike plate,etc complete all as specified and directed |
| 44 | M&L for second class hard wood 35mm thick glazed and skeleton shutters, devided into square with plain chamfered or rounded mitred and rounded rebated sash bars any numbers for window shutter, prepared to receive glass, gauze,etc, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc,all as per SSR Pt-l, complete all as specified and as directed. |
| 45 | M & L for factory made Flush shutters, 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 46 | S&F solid PVC doors frames of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, in opening as per specification complete all as specified and as directed. |
| 47 | S&F factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails, MS frame shall be covered withheat moulded plain colour PVC`C` channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles ad plain colour PVC sheet for top rail, lock rail & bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame complete all as specified and directed and shown on drawings of SSRPart-II . |
| 48 | S & F Box Type steel windows, Ventilator with side hung shutters (double shutters for glass and gauge ) joined together with and including grills using 12 mm square bars @ 10 mm c/c as per TD No CEBZ/TD/14/2011, Sheet no -1/7 to 7/7 Including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and weldedand preparing new steel surfaces, exc. 10 cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed. |
| 49 | S&F for 3mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding0.5 sqm in each pane including hacking out old broken glass of any thickness and any description from wooden/ steel frame/ stone,concrete or brick surrounds complete all as specified and directed. |
| 50 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 51 | S&F for aluminium door closer hydraulically regulated,designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixedcomplete all as specified and directed. |
| 52 | S&F for Butthinges, 100 mm size, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and directed. |
| 53 | S&F forAluminium handles, cast type anodised of Size 150 mm complete all as specified and directed. |
| 54 | S&F for 150 mm long aluminum anodized barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 55 | S & F 250 mm aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet , cast or extruded sections or cast aluminium alloy complete all as specified and directed. |
| 56 | S&F for 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed |
| 57 | S&F for curtain rod of Stainless steel 23-25 mm dia pipe thickness not less than 0.8mm of pipe with fixing bracket, side nobes etcfixed on walls with screws with PVCrawl plugs etc complete all as specified and directed. |
| 58 | M & L for applying two coats of synthetic enamel paint subsequent coat on new steel surfaces for grills, guard bars, shutter etc including preparation of surfaces and including and over one coat of red oxidecomplete all as specified and directed. |
| 59 | S&F 75 mm diaPVC (SWR ) pipes single socketedin any length with rubber ring jointslaid in trenches or in floorcomplete all as specified and directed |
| 60 | S&F 110 mm diaPVC (SWR ) pipes single socketedin any length with rubber ring jointslaid in trenches or in floorcomplete all as specified and directed |
| 61 | S&F 110 mm diaPVC (SWR ) pipes single socketedin any length with rubber ring joints fixed on wall with necessary clampcomplete all as specified and directed |
| 62 | S&F, PVC (SWR) bends any radius, 75 mm bore, provided with access doorcomplete all as specified and directed. |
| 63 | S&F, PVC (SWR) bends any radius, 110 mm bore, provided with access doorcomplete all as specified and directed. |
| 64 | S&F, 75 mm bore, PVC (SWR) junction single (single T), equal or unequal,provided with access door complete all as specified and directed. |
| 65 | S&F 110mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed. |
| 66 | S&F for 110mm dia PVC(SWR) vent cowl, complete all as specified and directed. |
| 67 | M&L PVC floor trap ,plain with grating including jointing to waste pipe with solvent cement dia of outlet 75mm complete all as specified and directed. |
| 68 | M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 69 | S&F for 1000 ltr capacity rotational moulded polythene water storage tank two layers ISI Marked (cylindrical vertical with closed top ) hoisted and fixed in position complete all as specified and directed. |
| 70 | S&F Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe of 20mm bore of brass ferrule complete all as specified and directed |
| 71 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fixed to walls and ceiling or laid in floor etccomplete all as specified and directed. |
| 72 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fixed to walls and ceiling or laid in floor etccomplete all as specified and directed. |
| 73 | S&F 25mm stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union fixed complete all as specified and directed. |
| 74 | S&F for Stainless Steel Peg Set of 6 hooks ISI marked medium weight complete all as specified and directed. |
| 75 | S&F for 600 x 450 mm size bevelled edge Mirror of selected quality glass mounted on 6 mm thick commercial plywood water proof with aluminium frame all around and fixed on wall with wooden/Plastic cleats and brass chromium plated screws complete all as specified and directed. |
| 76 | S &F tublar towel rail 20mm dia D type 60 cm long between flange Aluminium anodised complete all as specified & directed. |
| 77 | S&F PVC connection of 600 mm length complete all as specified and directed. |
| 78 | S&F wall mixturecast copper alloy ,with capstan heads chromium plated screwed down high pressurewith lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixedcomplete all as specified and directed. |
| 79 | S&F bib taps fency type 15 mm caste copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe and fixedcomplete all as specified and directed. |
| 80 | S&F stop cock fency type 15 mm caste copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe and fixedcomplete all as specified and directed. |
| 81 | S&F vitreous china wash hand basin white flat back of size 550 x 400mm excluding taps waste chain and plug and porcelain stopper but including brackets complete all as specified and directed. |
| 82 | S&F central hole basin mixture cast copper alloy ,with capstan heads chromium plated screwed down high pressurewith lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixedcomplete all as specified and directed. |
| 83 | S&F waste fitting for wash basins and sinks with inlet and outlet, screwed for pipe or connections, and with one cleaning cap, 32mm bore complete all as specified and directed. |
| 84 | S & F vitreous China Urinal, full stall type, whiteincluding providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement (excluding flushing cistern, flush pipe and waste pipe). |
| 85 | S & F urinal spreader of cast copper alloy,fancy type with chromium plated, screwed both ends for iron pipe or for unions, fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed. |
| 86 | S & F vitreous china urinal partition white of size 310x700 mm terminating about 40 cm above floor line including brackets, clamps and necessary items to fix on wall complete all as specified and directed. |
| 87 | S&F for shower rose brass chromium plated without swivel joints, 100 mm in size including fixing to steel pipe complete all as specified and directed. |
| 88 | S&F for viterous china wash down water closet pan (pedestal pattern) or wall mounted white fixing bolts, excluding flushing cistern and flush pipe including Seat cover, connection to drain and to flushing pipe syphonage pipe etc and mild steel chromium plated or aluminised hinges device & CP Jet complete all as specified and directed. |
| 89 | S&F for PVC valveless syphonic action type flushing cistern low level white with inlet ball valve,float end handle handle including bracket complete of capacity 10 litres, complete all as specified and directed. |
| 90 | S&F Health faucet ( ABS body) mild steel chromium plated suitable for 15mm dia pipe with1.25 metre long flexibleand ABS wall hoock including making connectionand fixing in position complete all as specfied and directed |
| 91 | S&F 32 mm bore PVC waste pipeand 65 cm long flexible complete all as specified and directed. |
| 92 | S&F for Soap dish of CP fixed with pvc rawal plugs and screw, complete all as specified and directed. |
| 93 | S & F grating doom 100mm dia of Chromium plated (Minimum weight 25gms to Nahani traps ect complete all as specified and as directed. |
| 94 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm longcomplete all as specified and directed |
| 95 | M&L 10mm thick screed on top of roof surfaces of any description in cement mortar 1:4mixed with liquid WPC @ 0.4% by weight of cement, surface finished even and smooth withoutusing extra cement complete all as specified and directed.Note : WPC shall be measured & paid seperately. |
| 96 | M&L bitumenous based primer conforming to IS-3384-1965 @ 0.40 Kg / Sqm including preparation of roof surface complete all as specified and as directed. |
| 97 | M&L for APP based polymeric membrane minimumweighing 3.0 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application method complete all as specified. |
| 98 | M&L for after laying the membrane apply coat of bituminouse aluminium paint @ 200 gm/Sqm (minimum) in two coats complete all as specified and as directed. |
| 99 | Surface excavationn. exc 30cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and directed. |
| 100 | M&L for 100 mm thick PCC(1:4:8) type D-2, (using40 mm graded stone aggregate), as in sub base for floor, finished even and rough complete all as specified and directed. |
| 101 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed |
| 102 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 103 | M&L 80 mm thickness machine pressed precast concrete interlocking paver block M-40 any shape and size confirming to IS 15658-2006 in grey cement and pigment glossy finish rubber mould casted laid dry over sandcushioning complete all as specified and directed. |
| 104 | M&L for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) in bed to drain pipe including packing under and hunching against the sides of pipes after they are laid and tested complete for pipe size of 150mm bore complete all as specified and directed. |
| 105 | M&L for 150 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 106 | M&L for providing cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) in surfaces channels drains and benching including form work and finishing fair and smooth using extra cement (forming fair finished channel shall be measured and paid for separately) complete all as specified and directed. |
| 107 | M&L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone agg) as in cover slabs for man holes and set in CM 1:4 including necessary from work complete all as specified and directed. Note: Reinforcement and form work shall be measured paid separately) |
| 108 | On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc,complete for 10 users with upflow filter including media complete all as specified and directed. |
| 109 | Soakage wells excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M25 concrete including intercepting chamber and screen chamber made of brick massonary in CM, RCC cover slab in M25/ SFRC cover , interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2M dia x 1.5 M effective depth complete all as specified and directed.as per TD No CEBZ/TD/78/2011. |
| 110 | M&L for GI pipe Med grade of 25mm dia alongwith all fittings and fixtures complete laid in trenchescomplete all as specified and directed. |
| 111 | All as item No.110above but of size 20 mm dia. |
| 112 | S&F cast iron/Brass Gate Valve cofiorming to IS 14846/2000,ISI Mark MS Spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts of size 25 mm dia complete all as specified and directed. |
| 113 | All as per item No.112 above but of size 20 mm. |
| 114 | M&L Granite slab18 mm to 20 mm thick machine cut, bedded and joined withcementand pointed with white cement with admixture of pigment to match over and including 20 mm thick screed bedCM (1:3) .the shade of granite stone including cutting and polishing type as incill and jamb/skirting, steps cooking plateformsincluding rounding off the exposed edges and polishing complete all as specified and directed. |
| 115 | M&L for 15 mm thick rendering in cement mortaron fair faces of brick work or concrete surfaces in cement mortar (1:6) and surface finishedeven and smooth, complete all as specified and directed |
| 116 | M&L for second class hard wood 35mm thick glazed and skeleton shutters, devided into square with plain chamfered or rounded mitred and rounded rebated sash bars any numbers for window shutter, prepared to receive glass, gauze,etc, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc,all as per SSR Pt-l, complete all as specified and as directed. |
| 117 | S&F 75 mm diaPVC (SWR ) pipes single socketedin any length with rubber ring jointslaid in floor or fixed on wall with necessary clampcomplete all as specified and directed |
| 118 | S&F 75 mm bore, PVC (SWR) junction single (single T), equal or unequal,provided with access door complete all as specified and directed. |
| 119 | S&F 110mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed. |
| 120 | S & F vitreous China Urinal, full stall type, whiteincluding providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed. |
| 121 | M&L, 10mm thick rendering on top of roof surfaces of any description in cement mortar 1:4mixed with liquid WPC @ 0.4% by weight of cement, surface finished even and smooth withoutusing extra cement complete all as specified and directed.Note : WPC shall be measured & paid seperately. |
| 122 | M&L 80 mm thickness machine pressed precast concrete interlocking paver block M-40 any shape and size confirming to IS 15658-2006 in grey cement and pigment glossy finish rubber mould casted laid dry over sandcushioning complete all as specified and directed. |
| 123 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level)complete all as specified and directed |
| 124 | Demolition of brickwork, plain cement concreteor stone/ boulder masonry, built in cement or lime mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified anddirected. |
| 125 | M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed |
| 126 | Demolition and breaking up drain pipes of 150 mm internal dia(Salt glazed ware, AC or Reinforced concrete) setin cement mortar complete all as specified anddirected. |
| 127 | M&L for DWCPE(SN8)150 mm bore / 163 (ID) mm bore of pipe laid and jointed on concrete bed 150mm thick, complete including testing etc complete all as specified and directed.(Concrete bed shall be measured and paid for separately) |
| 128 | Demolition and breaking up drain pipes of 200 mm internal dia(Salt glazed ware, AC or Reinforced concrete) setin cement mortar complete all as specified anddirected. |
| 129 | M&L for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) in bed to drain pipe including packing under and hunching against the sides of pipes after they are laid and tested complete for pipe size of 200mm bore. |
| 130 | M&L for DWCPE(SN8) 200 (OD)/175(ID)mm diameter Pipes laid and jointed with collar in CM 1:1 complete all as specified anddirected. |
| 131 | Demolition of reinforced concrete of any description and in anypositionnot otherwise specifically provided for etc complete all as specified anddirected. |
| 132 | M&L PCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in coping and grove cutting every 1.5m length including use & waste of necessary form work complete all as specified and directed. |
| 133 | Cutting into existing manholes for connecting new drains of internal dia 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed. |
| 134 | Construction of Septic tanks including excavation, in any type of soil, foundation In PCC 1:2:4 type B-2, brick work in CM 1:4, RCC M20 (Nominal Mixed) (with and including reinforcement), Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent pipe shaft and sludge chambers etc complete for 100 users complete all as specified and directed and shown in drawing No. CEBZ/TD/76/2011Sheet 1/4 to 4/4. |
| 135 | Construction of Soakage wells including excavation in any type of soil, foundation in PCC 1:3:6, wells of honey combed and solid in M-20(Nominal Mixed)Concrete type C2, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-20/ Brick Masonry/ filling with brick bats, complete of size 1.8 m in dia and 4.50m in deep (effective depth) all as specified and directed shown in drawing No.CEBZ/TD/76/2011 Sheet 1/2 & 2/2. |
| 136 | M&L concealed point wiring with PVC insulated and unsheathedelectric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No)not less than 20 mm diawith all fitting and fixing accessories and1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxesfactory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint insidefor mounting switches. sockets etc complete all as specified and directed. |
| 137 | One light point controlled by one switch. |
| 138 | One Ceiling fan point controlled by one switch. |
| 139 | One Exhaust fan point controlled by one switch. |
| 140 | One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch. |
| 141 | One 3 pin/5 pin switch socket outlet, 5 Amps on independent board. |
| 142 | Description all as per item No 110.00 here in before but point wiring with 2.5 sqmm FRLSH H confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire complete all as specified and directed. |
| 143 | S&F switch piano, flush button single pole one way 5 Amp complete all as specified and directed. |
| 144 | S&F socket out let, multipurpose, 2 in 1, 5 pin, 5 Amp complete all as specified and directed. |
| 145 | S&F switch piano, flush button single pole one way 15 Amp complete all as specified and directed. |
| 146 | S&F socket out let multipurpose flush type, 2 in 1, 6 Pin 5/15 amps complete all as specified and directed. |
| 147 | S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. |
| 148 | S&F electronic step rotary type fan regulator of two module capacity 80 to 100 Watt, 240 volts, AC 50Hz complete all as specified and directed. |
| 149 | S&FLamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete all as specified and directed. |
| 150 | S&F LED Lamp 09/10, efficiency > 130 lumen/wattwatt complete with 5 star rating complete all as specified and directed. |
| 151 | S&F Decorative ultra slim LED Tubelight fitting of LEDwith extruded polycarbonate, enviornmental friendly energy efficient ready to use, 20 watt, 6500Kfitting ,Efficiency >130 lumen /watt including reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed. |
| 152 | S&F security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt with photometric sensor, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 x 5 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqdlength of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed. |
| 153 | S&F Photometric sensor outdoor type 220-240 volt ambient light <5-15 lux working temparature -20~+40C working humidity <93% RH along with pvc connection of 6 to 10 amp capacity complete all as specified and directed. |
| 154 | M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 2.5 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 20 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 2.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 155 | S&F MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed. |
| 156 | S&F, MCB SPN63 Amps, 240 volts \"C\" series 16 KA including connection with suitable size copper lugs complete all as specified and directed. |
| 157 | S&F, MCB SP 240 volts, 6to 32 Amps, \"C\" series 10 KA including connection with suitable size copper lugs complete all as specified and directed. |
| 158 | Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable(Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 10 Sqmm 2 Core complete all as specified and directed. |
| 159 | Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed. |
| 160 | Supplying and laying un reinforced precast concrete cable coverClass LV, Type I, flat size 250mm x 150mm x 40mm complete all as specified and directed. |
| 161 | S&F tube \"Light\" grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed. |
| 162 | Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. |
| 163 | S&F Modular switch 1 way 6 A,1 module complete all as specified and directed. |
| 164 | S&F Modular Socket, 6A - 2/3 pin combined 2 module,complete all as specified and directed. |
| 165 | S&F Modular switch 1 way 16 A,1 module complete all as specified and directed. |
| 166 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 167 | S&F Decorative ultra slim LED Tubelight fitting of LEDwith extruded polycarbonate, enviormental friendly energy efficient ready to use, 10 watt,6500k as per requiredfitting , incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail