| 1 | Cleaning grass and removal of rubbish up to a distance of 50 m outside the periphery of the area. |
| 2 | Excavation of foundation in hard soil within 50 m initial lead and 1.5 m initial lift including rough dressing and levelling as per the direction of Engineer in charge. |
| 3 | Filling in foundation and plinth with sand watered and rammed. |
| 4 | Cement concrete (1:4:8) with 4 cm size hard granite metal. |
| 5 | Filling the foundation with excavated earth, i.e., 2/3rd quantity of excavated earth @2/3rd rate of earthwork. |
| 6 | R.C.C. work of M-20 grade with 20 mm and down grade black hard granite (Crusher Broken) stone chips including hoisting, laying, centering and shuttering. |
| 7 | Column Base |
| 8 | Columns |
| 9 | Plinth Beam |
| 10 | Lintel |
| 11 | Chhaja |
| 12 | Roof Beam |
| 13 | Roof Slab |
| 14 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. |
| 15 | Brick work with fly ash brick (23 x 11 x 8 cm) having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in foundation and plinth. |
| 16 | Brick work with fly ash brick (23 x 11 x 8 cm) having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in superstructure. |
| 17 | 6 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment. |
| 18 | 16 mm thick cement plaster (1:6) for brick work. |
| 19 | 12 mm thick cement plaster (1:6) for brick work. |
| 20 | Supplying, fitting and fixing vitrified tile of size 600 mm x 600 mm (Coloured/Printed) of approved make conforming to IS: 13755 laid on 20 mm thick C.M. (1:4) and filling joints with white cement of approved quality including cost of all materials, labour, etc complete. |
| 21 | Supplying, fitting and fixing vitrified tile of size 600 mm x 600 mm (Coloured/Printed) in dadoo, skirting and risers of steps on 12 mm thick cement plaster in C.M. (1:3) jointed with neat cement slurry to match the shades of the tiles including rubbing and polishing, cost of all materials, labour, etc complete. |
| 22 | Fixing chequered tiles in floors tread or steps and landing on 25 mm thick bed of cement mortar 1:1 jointed with neat cement slurry with pigment to match the shades of the tiles including rubbing and polishing complete. |
| 23 | Supplying, fitting and fixing chequered tiles in dadoo, skirting and risers of steps on 12 mm thick cement plaster in C.M. (1:3) jointed with neat cement slurry to match the shades of the tiles including rubbing and polishing, cost of all materials, labour, etc complete. |
| 24 | 2.5 cm A.S. Flooring with cement concrete (1:2:4) including punning using 12 mm size granite chips. |
| 25 | Supplying, fitting and fixing doors with A.I., M.S. sheet, fittings, cleats, hinges, etc. including welding, transportation, labour charges for fitting, etc. |
| 26 | Iron work wrought and put up in window grating including drilling holes in choukathas. |
| 27 | Supplying and fixing of two track UPVC sliding window of approved make with 6 mm thick glass of approved quality completed with frame, shutters and all fittings and fixtures. |
| 28 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6 mm size hard granite chips. |
| 29 | Priming one coat with any approved primer on steel surface. |
| 30 | Painting two coats with any approved paint on new steel surface. |
| 31 | Providing, fitting and fixing of false ceiling with 12 mm thick gypsum board, Aluminium anodised T Section No. 3215 with 2\"-0\" centre to centre, L section No. 1705 up to 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2\"-0\" x 2\"-0\" suspended from ceiling etc. complete. |
| 32 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, taxes, labour, etc complete. |
| 33 | Supply and fixing of MCM Modified Clay Material - MCM R Series Brick (087089) - 222 x 63 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge. |
| 34 | Priming one coat with any approved primer on plastered surface. |
| 35 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade. |
| 36 | Wall painting 2 coats with weather coat of approved shade on new work to give an even shade. |
| 37 | Recessed wiring to light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor ISI marked with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular G.I. box with modular base and cover of suitable size, MS box with 1.5 sq. mm FR PVC insulated copper conductor single core multistrand copper conductor as earth wire including all accessories and connection as per direction of the Engineer-in-charge. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard) |
| 38 | Group - A |
| 39 | Group - B |
| 40 | Supplying and fixing of 5/6 amp one way modular type switch on existing switch box/cover including connections etc as required. |
| 41 | Supplying and fixing of 5 pin 5/6 amp socket outlet modular type on existing switch box/cover including connections etc as required. |
| 42 | Supplying and fixing of 15/16 amp one way modular type switch on existing switch box/cover including connections etc as required. |
| 43 | Supplying and fixing of 6 pin 15/16 amp one way modular socket outlet piano type on existing box/cover including connections etc as required. |
| 44 | Supplying and fixing batten holder/BK angle holder ISI marked including connection etc. as required. |
| 45 | Installation, testing and commissioning of pre-wired flourescent/compact flourescent fitting of all sizes complete with all accessories and tube etc. directly on ceiling fan, including connection with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 46 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor etc. as required. |
| 47 | Installation, testing and commissioning of stepped type modular fan regulator, in existing switch box including connection with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required. |
| 48 | Supplying and fixing of modular G.I. box for 8 module 18 SWG on surface/recess with modular base & cover for 8 module in front including cutting the wall and making good the same in case of recessed conduit as required. |
| 49 | Supplying and fixing of modular G.I. box for 12 module 18 SWG on surface/recess with modular base & cover for 12 module in front including cutting the wall and making good the same in case of recessed conduit as required. |
| 50 | Supplying and fixing of 20 mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
| 51 | Recessed wiring to sub-main in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth as required. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard) |
| 52 | Recessed wiring to sub-main in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth as required. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard) |
| 53 | Supplyijng and fixing of 5 amp to 32 amp rating 240 V \"B\" miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required. |
| 54 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bus bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required. (But without MCB/RCCB/ISOLATOR) |
| 55 | Supply, installation, testing and commissioning of 63 Amp ICDP main switch on exisiting surface/wall mounting and complete with HRC fuse links, interconnections, earthing, etc as required as per the direction of Engineer-in-charge. (Make - SEIMENS/HPL/ANCHOR/L&T/ HAVELLS/C&S/RK) |
| 56 | Earthing with copper earth plate 600 mm x 600 mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having locking arrangement and watering pipe, etc. (But without charcoal and salt) as required. |
| 57 | Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. |
| 58 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required. |
| 59 | Extra for using salt and charcoal for G.I. or copper plate earth as required. |
| 60 | Providing, laying and fixing of one number of PVC insulated and PVC seathed/XLPE power cable (6 sq. mm 2 core PVC armoured cables ISI marked) of 1.1 KV grade of size not exceeding 25 sq. mm on surface as required. |
| 61 | Supplying, fitting and fixing 20W Tubelight including cost of conveyance, labour, T&P, complete, etc. (Make - Crompton/Polycab/Gold Medal) |
| 62 | Supplying, fitting and fixing 12W LED Overhead LED Light including cost of conveyance, labour, T&P, complete, etc. (Make - Crompton/Polycab/Khaitan) |
| 63 | Supplying, fitting and fixing 9W/10W LED Bulb including cost of conveyance, labour, T&P, complete, etc. (Make - Phillips/Polycab/Gold Medal) |
| 64 | Supplying, fitting and fixing 3-Blade 1200 mm Ceiling Fan including cost of conveyance, labour, T&P, complete, etc. (Make - Orient/Havells/VGuard) |
| 65 | Supplying, fitting and fixing of 100W/150W Flood Light including cost of conveyance, labour, T&P, complete, etc.(Make - Orient/Lister/Finolex) Please Enable Macros to View BoQ information |