| Sl. No. | Item Description |
| 1 | Single deck AHU (30% Fresh air & 70% recirculation):-Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7) sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 row deep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU\"s for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.Supply Air Fan Capacity, CFM : 1200Inline fan outdoor type of capacity 400 CFM to be installed at return ductDx Air cooled Load,TR : 07Total Supply side Static,Pa :1500 |
| 2 | Single Deck AHU (30% Fresh air & 70% recirculation):-Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with,consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7), HEPA filter (H-14),sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 rowdeep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU\"s for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.Supply Air Fan Capacity, CFM : 2600Inline fan outdoor type of capacity 800 CFM to be installed at return ductDx Air cooled Cooling Coil Load,TR : 17Total Supply side Static,Pa :1500 |
| 3 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness 0.63 mm complete as required. |
| 4 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness 0.8 mm complete as required. |
| 5 | Supply, installation, testing and commissioning of 0.63 mm aluminium sheet cladding as required complete in all respect with fixing screws etc., for cladding of outside / exposed ducts. |
| 6 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. |
| 7 | Supply, installation, testing and commissioning ofair diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core |
| 8 | Supply, installation, testing and commissioning of Fresh / Exhaust air intake louvers made from 3\" wide (Minimum 3 MM thk) powder coated extruded aluminium@ 1\" pitch with proper stiffeners complete with HDPE insect mesh fixed in a removable frame as per approved design. |
| 9 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Fire Damper |
| 10 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Actuator |
| 11 | Supplying and fixing of 19 mm thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \"O\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 12 | Supplying and fixing of 25 mm thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \"O\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 13 | Supply Installation, Testing & Commissioning for WARD AHU of modular type Variable Refrigerant flow /Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A/latest Refrigerant, vibration isolators, outdoor unit frame with suitable foundation,complete with all accessories as required etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at approx. 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 complete as per the technical specifications. Capacity: 35 HP |
| 14 | Supply Installation, Testing & Commissioning of AHU Kit consists of a control PCB, electronic expansion valve, complete with all accessories as required etc. This kit will connect the AHU to the VRF Outdoor Unit. |
| 15 | Supply Installation, Testing & Commissioning of Corded Thermostat cum controller for temperature setting and operation, along with communication and power wiring from AHU or VRF to Remote controller installation location inside ward complete with all accessories as required etc. (Dual mode: Cooling & Heating). |
| 16 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections ofthickness 19 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation for Suction and Liquid lines, complete with all accessories as required etc. |
| 17 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections ofthickness 41.27 mm dia (OD) (Soft drawn) with tube thickness 1.62 mm with 19 mm thick insulation for Suction and Liquid lines, complete with all accessories as required etc. |
| 18 | Supply, Installation, testing and commissioning of 40 mm dia nominal bore \"B\" class medium duty G.I. pipe conforming to IS 1239 including welding, fittings likes elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. complete in all respect for AHU condensate drain piping with 19 mm thick nitrile rubber insulation, nut-bolts, supports, pipe support block etc. duly installed with 0.63 mm aluminium sheet cladding as required complete in all respect with fixing screws etc. |
| 19 | Supply & Installation of Digital Magnehelic gauge (differential pressure transmitter) (Range: + 30 Pa ) of polycarbonate housing material along with all the neccessary accessories and suitable to install in modular panel with nozzle & complete accessories for clean rooms. |
| 20 | Supply, Installation, Testing & Commissioning of Electric tubular finned Heaters for WARD AHU of 12 kW capacity in SS construction and bank wise distribution, duly installed in ducts complete with mounting arrangement, safety thermostat, humidistat for humidity control, SSR based control, contactor etc.. Heater should be ISI marked. |
| 21 | Supply, Installation, Testing & Commissioning of Electric tubular finned Heaters for OT OAHU of 05 kW capacity in SS construction and bank wise distribution, duly installed in ducts complete with mounting arrangement, safety thermostat, humidistat for humidity control, SSR based control, contactor etc.. Heater should be ISI marked. |
| 22 | Supply, Installation, Testing & Commissioning of ultrasonic humidifier system operating at 240 volts / 50 Hz power supply, SS Material, controllers, humidistat to maintain humidity along with necessary sensors for auto operation as per variation in humidity and capable to provide following capacity of 7.5 Kg of mist /Hr |
| 23 | Supply, Installation, Testing & Commissioning of ultrasonic humidifier system operating at 240 volts / 50 Hz power supply, SS Material, controllers, humidistat to maintain humidity along with necessary sensors for auto operation as per variation in humidity and capable to provide following capacity of 5 Kg of mist /Hr |
| 24 | Fabrication,Supply,Installation,Testing,Commisioning of Outdoor floor mount type AHU control Panel, CPRI approved with following specifications: CRCA Sheet of 3.15 mm, Grey Colour with Incoming: 1 Incomer -250 Ampere MCCB/36KA 4 Pole. Panel must include R,Y,B Indicator, with 350 ampere aluminium busbar, 1No Digital Multi Function Metre / Digital Load Manager suitable to connect with Centre Energy Monitoring System/BMS through RS485 connection.Outgoing:Outgoing -1 Nos with 25 Ampere MCB/10/16KA 4 Pole “C” Curve for supply motor - 4 kW Outgoing - 1 Nos with 25 Ampere MCB/10/16KA 4 Pole “C” Curve for supply motor - 2.5 kWOutgoing -1 Nos with 100 Ampere MCCB/30KA 4 Pole for VRF outdoor unit. Outgoing -1 Nos with 40 Ampere MCCB/16/25KA 4 Pole for heaters - 12 kW (three bank distribution).Outgoing -1 Nos with 32 Ampere MCCB/16/25KA 4 Pole for heaters - 05 kW (three bank distribution) All outgoings shall be with necessary MCB\"s, contactors, relays, illuminated push button for manual ON & OFF, indication lamps ( for ON,OFF,TRIP Status), Auto/Manual selector switch..Outgoings with suitable rating MCB\"s shall be considered for UVGI system, fire damper, AHU limit switch etc.Necessary safety interlocks like AHU motor interlock with service door limit switch, fire damper interlock, supply & exhaust fan interlock, UVGI system and heaters interlocks with AHU).Potential free Contact (for supply motor, exhaust motor, fire damper, heater, humidifier etc.) to be provided for Connections.Note:-1. VFD (for motor speed control) with inbuilt PID controller for varying the speed of fan, along with DPT (0 to 3000 pa) sensor for measuring DP across fan and providing input to VFD. VFD to be installed/mounted in motor control panel.Capacity of VFD: 4 kW - 1 No. ( for Supply motor) Capacity of VFD: 2.5 kW - 1 No. ( for Supply motor) 2. Provision of MCB / Contactor for UVGI system, AHU limit switch, Fire damper etc. to be considered in AHU control panel. |
| 25 | Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored aluminum cable 3.5 C X 95 sq. mm |
| 26 | Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 16 sq. mm |
| 27 | Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 10 sq. mm |
| 28 | Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 6 sq. mm |
| 29 | Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 1.5 sq. mm |
| 30 | Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc. armored copper cable 2 C X 1.5 sq. mm |
| 31 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 150 mm width X 50 mm depth X 1.6 mm thickness |
| 32 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 100 mm width X 50 mm depth X 1.6 mm thickness |
| 33 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 15 mm internal dia of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 34 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 35 | Supply, Installation, testing and commissioning of 25 mm dia nominal bore \"B\" class medium duty G.I. pipe conforming to IS 1239 including welding, fittings likes elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. complete in all respect for humidifier connection including nut-bolts, supports, pipe support block etc.as required complete in all respect. |
| 36 | Supply and installation of 50 mm thick double skin modular wall made of 0.8 mm thick SS-304 sheet on both the sides, with 40 (plus or minus) 2 kg/m3 density PUF as infill, GI profiles all along the periphery, flush on both sides with maximum allowable gap of 3- 4mm filled with food grade silicon sealant and placed on cold rolled galvanized bottom tracks with a recess to provide floor to wall coving flush with the wall panel. The panel should comprise of canceled PVC conduits for electrical wiring and Return air risers with Aluminum perforated return riser grills. This includes all required hardware for completion Panels to be covered with a protective film to avoid any damages during transportation and installation. |
| 37 | Supply and installation of 50 mm thick double skin modular ceiling Panels made of 0.8 mm thick SS-304 sheet on both sides, with 40 (plus or minus 2) kg/m3 density PUF as infill, GI profiles all along the periphery, flush on both sides with maximum allowable gap of 3- 4mm filled with food grade silicon sealant and placed on cold rolled galvanized bottom tracks with a recess to provide wall to wall flush with the wall panel. This includes all required hardware complete with supporting arrangement and Panels to be covered with a protective film to avoid any damages during transportation and installation. |
| 38 | SITC of Laminar flow filter module of suitable size as required made out of heavy duty Aluminium powder coated extrusion with minimum and to house HEPA Filter at the rate 0.3 microns , 99.9997, H- 14Grade, Filter loading from OT side Includes aluminum power coated capsule perforated diffuser. This includes all required supports and accessories as per site requirement. |
| 39 | Providing, laying of scratch proof PVC/Vinyl flooring of 2mm thickness with proper welded joints airtight, along with self leveling compound to match the existing flooring levels inside the OT as required at site. |
| 40 | Clean room Doors 46 mm thick flush sliding doors made of 0.8mm thick SS-304 Sheet on both sides, with 40 plus or minus 2 kg/m3 density Honeycomb with stand, door frames, double glazed vision panel with necessary adhesive tapes and silicon sealant, necessary hard ware like SS-304 ball bearing butt hinges, D- handles, push plates, door closure, concealed tower bolt, drop seals for the double leaf door and provision for fixing magnetic type door interlocking system and automatic door bottoms, Both side lock and keys etc with double glazed view panels.Double Leaf:- 2.1 m x 1.8 m |
| 41 | Supply, Installation, Testing and commissioning of TOUCHSCREEN OPERATING ROOM CONTROL PANEL with* Time Elapsed Clock* Time Day Clock* Hands free telephone* Medical Gas Alarm - 5 service with audio visual alarm with sensors* Temp & Humidity display with controlling and sensors* Peripheral Lighting On/Off with dimming control* HEPA Filter status with alarmComplete with all the accessories as required at site. |
| 42 | Supply and Installation and Commissioning of proper Pressure Relief Dampers having multi 304 graded stainless steel blades for maintaining the positive pressure inside the operation theatre PRESSURE RELIEF DAMPER should be CE certified/Equivalent |
| 43 | Supplying, Installation, Testing and Commissioning of Operating list board Supply and Installation ,Testing and commissioning of OPERATING WRITING LIST BOARD in thickness of size (948mm x 648mm) |
| 44 | Supply, Installation, Testing and Commissioning of Two Plate dimmable X-Ray viewing screen designed to provide a high level of control luminance without flicker. The dimming range should be from 3-100% . The Xray should have inbuilt sensor for Xray film . On/Off and dimming operation should be through integrated PCB. TWO PLATE XRAY should be CE certified and in compliance under Class 1 Medical devices /Equivalent . |
| 45 | SCRUB STATION (min size 1500mm)SITC of scrub station as per consignee approved drawingCompact surgical scrub sink should be designed for use in IVF complex providing for preProcedurals crub up.(Double sin combination as suitable)Each fixture should be fabricated from heavy gauge type 304 stain less steel (minimum thickness 1.5mm) and should be seamless welded construction, polished to a satin finishThe scrub sink should be provided with a front access panel which should be easily removed for access to the water controlled valve, waste connections, stoppers and strainers.Hands free operation should include in frared sensors with program able adjustment.Thermostatic mixing, valve control should be located behind the access panel and maintainConstant water temperature.Timing should be adjustable to meet individual application requirements.Provided within frared sensors, thermostatic control taps with fail safe temperature controls.All units should have reduced anti-splash fronts. |
| 46 | Supplying, Installation, Testing and Commissioning of Storage unit of size 200 cm x 120 cm x 35 cm and shall be made with at least 0.8 mm thick SS 304 stainless steel panels complete all as per required. |
| 47 | Supply and Transportation 42 W Clean room Light fixture,600mm x 600mm LED luminaire CRCA powder coated white after phosphocreatine treatment provided as standard with high efficiency acrylic wide diffuser, with wide operating voltage range, Power factor greater than 0.9, Surge protection greater than 2KV etc as required at site for Modular OT. |
| 48 | 20 KVA Online UPS with 30 minutes Battery BackupSMF battery backup with30 minutes battery backup with SNMP and isolation transformer, battery rack inter connection links Rectifier & Inverter with IGBT and DSP Technology. Voltage 400±15%V, 3Phase, 4Wire.Frequency:-45to55Hz.Display: Control Panel with LCD Screen.Battery:-Sealed Maintenance Free Rechargeable. Backup: 30 minutes, Protection-: Overload & Short Circuit.Ventilation:-Forced Air Cooling. |
| 49 | Supplying, installation, Testing and Commissioning of OT light, I luminance (Lux)-160000, Colour Temperature-3800-5100, Field diameter (mm)-150-300, Illumination Depth (mm)-800-1600, Control Panel-Touch / Keypad, LED Life-50000 hrs |
| 50 | Supplying, Installation, Testing and Commissioning of AnesthetistPendant, Instrument platform: two layers (height adjustable); rounded bumper design, each platform can load 20kg, Weight loading: 150kg;Power supply: AC220V, 50HZ;AC110V, 60HZElectrical outlet: 8 pcs (220V / 10A);Potential ground terminal: 2pcs;The network interface: RJ45 1pc;Drawer: 1pc; Syringe pump rack 1pc, infusion pump rack 1pc;The main material: high-strength aluminum alloy, The surface treatment using imported high-voltage electrostatic powder spray; Ceiling-mounted, high stability |
| 51 | Supplying ,Installation ,Testing and Commissioning of Surgeon pendant, Instrument platform: two layers (height adjustable); rounded bumper design, each platform can load 20kg, Weight loading: 150kg;Power supply: AC220V, 50HZ;AC110V, 60HZElectrical outlet: 8 pcs (220V / 10A);Potential ground terminal: 2pcs;The network interface: RJ45 1pc;Drawer: 1pc; Syringe pump rack 1pc, infusion pump rack 1pc;The main material: high-strength aluminum alloy, The surface treatment using imported high-voltage electrostatic powder spray;Ceiling-mounted, high stability |
| 52 | Comprehensive maintenance of the complete MOT installation for 1st year after completion of Defect Liability Period/Warranty Period of five years as per terms and conditions of comprehensive maintenance described in the NIT. |
| 53 | Comprehensive maintenance of the complete MOT installation for 2nd year after completion of Defect Liability Period/Warranty Period of five years as per terms and conditions of comprehensive maintenance described in the NIT. |
| 54 | Comprehensive maintenance of the complete MOT installation for 3rd year after completion of Defect Liability Period/Warranty Period of five years as per terms and conditions of comprehensive maintenance described in the NIT. |
| 55 | Comprehensive maintenance of the complete MOT installation for 4th year after completion of Defect Liability Period/Warranty Period of five years as per terms and conditions of comprehensive maintenance described in the NIT. |
| 56 | Comprehensive maintenance of the complete MOT installation for 5th year after completion of Defect Liability Period/Warranty Period of five years as per terms and conditions of comprehensive maintenance described in the NIT. |
| 57 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%,humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm,cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as perspecifications, drawing and asper directions of the Engineer-in-Charge with fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 58 | Dismantling and removal of existing false ceiling including HVAC Ducts at all heights, including carefully taking down the tiles, inter-locking T-grid framework of hot-dipped galvanised iron sections, suspension system (dash fasteners, hanger rods, level adjusters), perimeter wall angles, and associated fixtures, with stacking of serviceable material within 50 m lead and disposal of unserviceable material, all complete as per directions of the Engineer-in-Charge. |
| 59 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 60 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 61 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 62 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 63 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 64 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 1 X 10 sq. mm earth wire |
| 65 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 66 | Supplying and fixing suitable size GI/PVC box withmodular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 &15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 67 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 68 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. 5/6 A switch |
| 69 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. 15/16 A switch |
| 70 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 71 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 72 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module |
| 73 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 74 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 75 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 76 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt), Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life, CCT/6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm),36 Watt |
| 77 | Supply and Fixing following rating, four pole 415 volt TPN MCB in the existing MCB DB complete with connection , testing and commissioning etc. as required MCB TPN 63 amp, C Curve |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |