| 1 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete. |
| 2 | Demolition of cement concrete(reinforced) of any description and any thicknes and in any position, complete all as specified. |
| 3 | M&L for pre-painted galvalume aluminium zinc coating GI basedcorrugated steel sheet 0.50 mm thick of an colour having tensilestrength of 550Mpa as in roof covering/ cladding to wall, fixed withself tapping screws incl ridge all as specified and directed . |
| 4 | M&L for pre-painted galvalume aluminium zinc coating GI basedplain steel sheet 0.50 mm thick of an colour having tensilestrength of 550Mpa as in ridge of roof covering/ cladding to wall, fixed withself tapping screws incl ridge all as specified and directed . |
| 5 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 6 | Demolition ofwall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets,all as specified. |
| 7 | S&F structural steel work as in roof trusses,purlins, rafter, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-290-W (Gde-E-165) quality B complete all as specified. |
| 8 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles of size 595x595 mm of approved texture , design and patterns having moisture content less than 2% , humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225;1987 , Noncombustible as per BS476 (part4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per Sqm including both sides) comprising of main T-runners of size15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per Sqm) i.e 50 mm long , 8mm outer dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, galvanized iron perimeter wall angle of 24x24x0.40 mm length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. the work shall be carried out as per manufacturers instructions specifications, drawing and as per complete all as specified & directed. |
| 9 | Taking down chowkat or frames with shutters (without taking off shutters from the frames)exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as specified. |
| 10 | Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar. |
| 11 | M & L for 25 mm thick cement concrete in flooring type B0, 1:2:4 (12.5mm graded stone aggregate)for laying floor tiles. |
| 12 | M&L for Virified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm,as in floors etc set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile colorincluding screed bed or bedding layer of mortar 15 mm thick for laying floor finishes withCM 1:4 (Tile pattern and decoration may be as suggested by Engineer-in-charge) |
| 13 | M&L for Vitrified Ceramic (light Shade) tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirtingetc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including back coat of cementmortar 10 mm thick for laying floor finishes withCM 1:4 as approved by the Engr-in-Charge |
| 14 | M&L for 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 15 | S&F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 16 | S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket and including necessary locks/handels etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per the directions of Engineer-in-charge. |
| 17 | S&F 4.00mm thick sheet glass, selected quality with solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers and glazing with rubber beading or with glazing clips, all as specified and directed. |
| 18 | S&F 5.5 mm thick sheet glass frosted on one side, selected ordinary quality and glazing with rubber beading or with glazing clips, all as specified and directed. |
| 19 | Supply and fixing brass mortice lock vertical type, size 100 mm 4 lever complete all as specified and directed. |
| 20 | S& F Galvanized mild steel wire-cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L for preparation ofsteel surfaces of any descriptionexc 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&Fmild steel cold rolled butt hinges mediumweight 100 mm long complete all as specified. |
| 23 | S&F 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 24 | S&F aluminium handles cast type anodised of size 200mm long ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, complete all as specified and directed. |
| 26 | S&F in repair 25 mm dia stainless curtain roadcomplete with stainless bracket and side caprs fixed in positionby drilling holes in walland fixed the bracket with rawl plug and SS screw all as specified and as directed |
| 27 | Demolition of brick work or stone masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, all asspecified . |
| 28 | M & L for Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in CM 1:6, complete all as specified and directed complete all as specified and directed. |
| 29 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified. |
| 30 | M & L for rendering in two layer onfair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with WPCas per manufacturer\"s instructions of cement for fair finished over 10 mm thick rendering incement mortar 1:4 complete all as specified and directed. |
| 31 | M&L forrendering 10 mm thick cement plaster on brick/concrete surfacesetc in cement mortar 1:4 and finished even and smooth without using extra cementall as specified and directed. |
| 32 | Supply Only integeral water proofing compound (liquid) |
| 33 | Supplying and fixing galvanized iron chicken wire mesh of approved quality, 20 gauge (approx. 0.9 mm), with mesh size not exceeding 25 mm x 25 mm, securely fixed with nails, screws, or staples over the existing cracks and extending a minimum of 75 mm on either side of the crack all as specified and directed. |
| 34 | M&L for complete removal of existing treatmentand applying one coats of alkali resitant primer and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty on wall complete all as specified and as directed. |
| 35 | M & L preparationof newly plastered surfaces of walls and applying two coat of oil bound distemper over one coat of primer ove a coat of 1 to 2 mm thick water proof wall care putty, complete, all as speicfied and directed. |
| 36 | M&L for complete removal of all existing treatment and preparing surfaces of walls andapplying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacescomplete all as specified and directed by Engineer - in – Charge |
| 37 | M&L for preparation of new plastered surfaces of walls andapplying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacescomplete all as specified and directed by Engineer - in – Charge |
| 38 | Demolition of cement concrete(unreinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level) complete all as specified. |
| 39 | M&L for providing 75mm thick PCC 1:3 :6 type C-2 using 40mm graded crushed stone aggragate as in plinth protectionall as specified. |
| 40 | M&L for anti-termite treatment by treating the soil under plinth protection at the rate of 5 liters of emulsion per square metre of surface area complete all as specified and directed by the Engr-in-Charge. |
| 41 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fair finished surface complete all as specified and directed by Eng-In-Charge |
| 42 | M&L for Reinforced cement concrete (nominal mix) Type B1 (1:2:4)with 20mm graded stone aggregate as in beamsall as specified and directed by Eng-In-Charge |
| 43 | Supply and fix TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all asspecified and directed by Engineer-in-Charge. |
| 44 | Supply and fix TMT bars 6 to 8 mm dia, as in stirrups cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all asspecified and directed by Engineer-in-Charge. |
| 45 | M & L for 16 to 18 mm thick machine cut green marble stone as in floor, steps (in single piece), cooking platform, cills of window etc laid over 15 mm thick cement screed and jointed withbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including15mm thick plaster incement mortar 1 : 4 complete all as specified and as directed. |
| 46 | Taking down carefully copper/aluminum point wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc. |
| 47 | Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity. |
| 48 | M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVCConduit and all accessoriesConcealedinwalls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with modular white cover plate with frame for housing the switches, socket outlets, fan regulators and blank cover etc complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed for the following:- |
| 49 | For one light point controlled by one switch |
| 50 | For onefanpoint controlled by one switch |
| 51 | For one5 Amp independent socket point controlled by one switch |
| 52 | For one 3 pin ,5 Amp socket point with other switch on the same board |
| 53 | All as per item No48 here in before but for power point wiring usingwith 2.5sqmm PVC-FR LS insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engir in charge. |
| 54 | S&F Modular switch, one way, 6 Amp 230, 1 module all as specified and directed by Engr in charge. |
| 55 | S&F socket Modular 6 Amp-2/3 pin combined 2 module all as specified and directed by Engr in charge. |
| 56 | S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt all as specified and directed by Engr in charge. |
| 57 | S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt . all as specified and directed by Engr in charge. |
| 58 | S&F ceiling rose, surface backlit,three terminal. all as specified and directed by Engr in charge. |
| 59 | S & F of wall mounted fancomplete with blades, with all accessories, 230V, 400mm sweep.with service value 6.00 BEE, five star ratedall as specified and directed. |
| 60 | Supply and fix exhaust fan made of sturdy Engineering plastic complete withlouvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250MM including making hole in stone /brick wall grouting &making good in all aspects including taking out old existing exhaust fan all as specified and directed. Note :1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. complete all as specified and directed 2. Making suitable size of hole on wall for fixing the exhaust fan .3. 02 years guarantee to be provided by the contractor. |
| 61 | Supply and fixing LED light fitting made of Aluminium extrusion mirror type with high out put diffuser 1x10 watt 2 feet, input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 with driver including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed by Engr in charge.Note : Warrenty on light should be of minimum 02 Years provided by contractor. |
| 62 | S&F testing and commissioning of MCB SP 6 Amp to 32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs. |
| 63 | S&F testing and commissioning of MCB SPN 240 volt 40 Amp10 KA capacity having C-curve characteristics connected with suitable lugs . |
| 64 | S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 12 way, 240 V with 200 Amps rated bus bar . |
| 65 | S&F Modular AC box enclosure with socket plug top and MCB SP 25 Amps (01 No) flush mounting enclosure .complete all as directed by Engineer-in-Charge |
| 66 | S&Fin replacement of recess mounted LED Flate panel 2x2made out of CRCA sheet housing duly coated with high efficient LEDs & Glare free full opal diffuser ,IP 20 and with system Efficancy of 120lm/W, 36 Watt LED packageand Unique pattern acrylic de-glaring diffuser sheet for glare-free uniform light distribution suitable forarmstrong/grid ceiling all as specified and directed byEngr -in -charge. |
| 67 | M&L concealed sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size4 sqmm (for main current) drawn in & incl PVC conduitnot less than 25mm dia ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as directed by Engineer-in-Charge Note : One length of PVC Conduit and 3 run of cable (02 Run main wire & 01 Run earth wire) shall be measured and paid as one length. |
| 68 | Taking down old existing fitting any type and Supply, fixing and Connecting of LED building security light fitting in top opening LED, highly efficient LED light made of pressure die cast aluminium housing with low power LED\"s, direct modular IP lens,IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device ,lumens should be ≥120 lm/w ,OEM driver,PF 0.9,CCT 5700K complete of capacity 25 wattage. |
| 69 | M&L for provn of Earthing complete with galvanised steel earth plateelectrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steelall as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the costof the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. |