| 1 | Supplying, installation, connecting, testing and commissioning of ISI marked outdoor type distribution transformer of 315 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed copper wound step down enrgy saving ( level 2) floor mounted complete with first fillingISI marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group DYN -11 complete all as specified and as directed by the Engineer in Charge. Note - (i) The ambient temprature shall be 48 degree Centigrade when measured by the resistance method after continuous full load run . (ii) The transformer shall be complete with standard fittings all as specified and conforming to IS:335 of 1993 for oil and IS: 1180 Part -I of 2014 for transformer and comprising of followings:- (i) Oil conservator with oil filling hole cap and drain plug. (ii) 01 No of prismatic oil level gauge mounted on conservator wall with first fill of charge upto maximum level. (iii) Silica gel dehydrating breather with oil seal and with first fill of charge. (iv) Pressure release valve with automatic resetting arrangement after release of pressure- 01 Set. (v) Adequate No of thermometer pocket including one thermometer. (vi) Top oil filter valve. (vii) Bottom oil filter cum drain valve. (viii) Rating diagram and terminal marking plate.(ix) Earthing terminal - 02 Nos. (x) Lifting lugs - 01 Set. (x) Jacking pads - 01 Set. (xi) Under carriage with 4 Nos of plain rollers. (xii) Air release plug on main transformer tank. (xiii) Adequate Nos of cooling radiators. (xiv) 100 mm dial type oil temperature indicator with maximum read pointer and resetting device. (xv) 100mm dial type winding temperature indicator with maximum read pointer resetting device. (xvi) Air insulated cables box on HV and LV side. (xvii) Buchholz Relay (having Contacts for Alarm & Trip). (xviii) OTI (having Contacts for Alarm & Trip). (xix) WTI (having Contacts for Alarm & Trip). (xx) Marshalling Box (having TTB Only).Note : (i) PCC foundation of adequate /required size extending 500mm all round more than size of Transformer, as per manufacturer design shall be included in quoted Rate. (ii) Prior to manufacture the contractor shall get the general arrangement, drawing and design details of the Transformer from GE.(iii) After installation of Transformerat site , the pre-commissioning test shall be carried out by SEI/EI / Rep of Accepting Officer and the cost deemed to be included in the quoted rates. |
| 2 | M & L for switch air break gang operated triple pole out door type unit on HT 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on insulators (12 insulators) with Drop out fuse unit frame with operating mechanism worked from ground level with earth switch and including locking arrangement complete all as specified and directed. |
| 3 | S & F Lightning arresters expulsion type complete with all fittings, transmission class 11 KV, discharge capacity 65 kilo amp complete all as specified and directed |
| 4 | S & F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed. |
| 5 | Supply, laying & testing HT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 95 Sqmm 3 core complete all as specified and as directed. |
| 6 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm 3 core complete all as specified and directed. |
| 7 | Supplying laying jointing, testing & commissioning in trenches, fixed on poles/ drawing through pipes LT XLPE insulated, screened, PVC beddedgalvanised steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor, 1100 volts grade (Earthed) crossectional area size of 400 sqmm 3.5 core complete all as specified and directed. Make ;- Havells/KEI/Finolex/Polycab |
| 8 | Supplying laying jointing, testing & commissioning in trenches, fixed on poles/ drawing through pipes LT XLPE insulated, screened, PVC beddedgalvanised steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor, 1100 volts grade (Earthed) crossectional area size of 185 sqmm 3.5 core complete all as specified and directed. Make ;- Havells/KEI/Finolex/Polycab |
| 9 | Design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 2.00mm thick CRCA Sheet for inner partition walls, independent cabinate with cabinate doors for MCCBs, Bus Bars, cable trays, metering equipment,vertical type floor mounted on angle iron frame of ISA 45x45x5mm with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid aluminium bus bar 4 strips suitable of 1000 Amps, suitablily grouted to PCC complete with internal wiring, epoxy powder coated, connections of cable ends with suitable size of aluminium cable lugs with the following accessories.Make of MCCB- Havells / L&T / Legrand / Schneider/ABB(a) INCOMING(i) MCCB 500 Amps, 4 Pole, 415 V, 36 KA- 01 No(b) OUTGOING(i)MCCB 320 Amps, 4 Pole, 415 V, 36 KA - 02 Nos(ii)MCCB 125 Amps, 4 Pole, 415 V, 25 KA - 01 Nos(iii) MCCB free space for 320 Amps(iv)Digital Ammeter of size 4\"x4\"- 01 No(v)Digital volt meter of size 4\"x4\"- 01 No(vi) Selector Switch for Amp/Volt Meter - 02 Nos(vii) Current Transfer (CT)-3 Nos(viii) Phase indicator lamp (RYB) set of three - 01 Nos |
| 10 | Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed. |
| 11 | Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed. |
| 12 | Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed. |
| 13 | M&L for PCC cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed. |
| 14 | M&L for PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed. |
| 15 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. |
| 16 | M & L for road cutting incl necessary excavation 45 cm wide and90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable throughpipeafter laying /through the cable trenches will be fillingtop withM&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbedsurface etc complete all as specified and directed. |
| 17 | M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 100 mm dia bore complete all as specified and as directed.Make :- Surya/Jindal/TATA |
| 18 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to GI Strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 19 | Material and labour of Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as directed by Engineer-in-Charge. |