| 1 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 2 | Repair of door, window shutters including cost of material and labour for change of damaged : |
| 3 | Steel Locking Bolt |
| 4 | Steel Handle 6\" size |
| 5 | Stopper of Aluminium with Double Rubber Gutka |
| 6 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete Old Plastered Surface (two or more coats) |
| 7 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 8 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRTH Specification Clause 401 For Grading III Material |
| 9 | Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/ park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc. (As per table 1 of IS 15658:2006) Category ‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP 63:2004 |
| 10 | Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm |
| 11 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix. |
| 12 | Grading roof for water proofing treatment with water proffing compound Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 13 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 14 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete Old Plastered Surface (two or more coats) |
| 15 | Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provisionRoller Finish av. thickness 400 to 500 microns. |
| 16 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 17 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision Old Work |
| 18 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work |
| 19 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Old work (One or more coats ) |
| 20 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work. Please Enable Macros to View BoQ information |