| 1 | Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level. |
| 2 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar etc. |
| 3 | M&L for providing 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as directed. |
| 4 | M&L for coloured glazed ceramic tiles digitally printed 300x450mm, 7-8 mm thickas approved by GE as in dado / skirting or on vertical surfaces,over and including 10 mm thick backing coat in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile etc complete all as specified and directed. |
| 5 | M&L for non skid ceramic coloured tiles 7-8mm thick matching to dado tiles area of each tile 400x400mm, as in floor etc laid over and including screed bed 15mm thick in cement mortar 1:6 set and jointed with white or coloured cement to match complete all as specified and as directed. |
| 6 | M&L for 18-20mm thick machine cut kota stone slab in flooring, stepsover 20 mm thick screed base in cement and sand (1:6) mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge |
| 7 | M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar including 15 mm thick backing coat in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge |
| 8 | M&L for 16-18mm thick rough dressed Shahabadstone as in floor/plinth etc over and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 9 | Fixing only 16-18mm thick rough dressed Shahabadstone as in floor/plinth etc over and incl 15mm thick screed bed in CM 1:6 including dismantling complete all as specified and directed |
| 10 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar etc. |
| 11 | M&L for stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. |
| 12 | Fixing only stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. |
| 13 | Demolition of brickwork or stone bouilder masonary built in cement mortar or lime mortar complete all as specified |
| 14 | M&L for Walling of random rubble, uncoursed well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified |
| 15 | M&L for extra over stone walling for hammer dressing to face stones and dressing of face beds and joints on granite or tap stone with maximum depression on face from straight edge held against the dressed surface n exc. 20mm as specified, of random rubble walling, uncoursed or brought upto courses |
| 16 | M&L for brickwork with fly ash bricks straight or curved on plan exc6mmean radius,built in CM 1: 6 complete all as specified |
| 17 | M&L for brickwork with fly ash bricks straight or curved on plan exc6mmean radius,built in CM 1: 6 complete all as specified |
| 18 | Raking out cement mortar joints/ pointing to random rubble or polygonal rubble uncoursed or brought up to coursesetc complete all as directed. |
| 19 | M&L for Pointing to random rubble or polygonal rubble uncoursed or brought up to courses in CM1:4etc complete all as directed. |
| 20 | Taking down cement mortar plaster on brick or stone walls,raking out joints, hacking for key complete all as directed |
| 21 | M&L for dubbing out average 10mm thick in CM 1:6on irregular face of walls (when specifically ordered in writing) |
| 22 | M&L forrendering, 15 mm thick on brick/Stone Masonry/ concrete surfaces in cement mortar 1:6 surfaces finished even and smooth without using extra cement including sagol finished complete all as specified. |
| 23 | M&L forrendering, 15 mm thick on stone/ brick / concrete surfaces in cement mortar 1:4finished even and fair without using extra cement complete all as specified and directed. |
| 24 | M&L for rendering 5mm thick on concrete surface of ceiling in CM 1:3 finished even and fair without using extra cement complete all as specified and directed. |
| 25 | M & L for preparation of newly plastered surface of walland apply two coats of OBD over a coat of primer any height including scaffholding etc complete all as directed. |
| 26 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/ old surfaces. |
| 27 | M&L for preparation of newly plastered surface of ceiling and apply three coats of white wash any height including scaffholding etc complete all as directed. |
| 28 | M&L for preparation of old plastered or unplastered surfaces of ceiling including cornices etc by brooming down or steel wire brushingscraping down smook soot, moulds, moss and efflorescent salt, trading oil and greasy spots and applying one coat ofwhite lime wash at any height including scaffholding etc complete all as specified and directed by Engineer-in-charge. |
| 29 | M & L for preparing old plastered surfaces of wallsand apply two coat of OBD, finished with roller finish on plastered surfaces of wall any height including scaffholding etc complete all as specified and directed |
| 30 | M&L for 2 mm thick wall care putty etc complete all as specified and directed |
| 31 | S&F fix in repairs wash hand basin with pedestal vitreous China white , flat back or angle type of size 550 X 400 mm incl waste chain and plug and porcelain stopper , waste pipe, a pair of brackets, or erecting stand and PVC connection etc complete all as specified and directed by Engineer-in-Charge |
| 32 | S&F in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistern etc complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply only 10 ltr capacity PVC valve less, symphonic action type, flushing cistern, low level, all accessories etc complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F in repairs, chromium plated shower rose (size 125 mm) with shower armetc complete all as specified and directed by Engineer-in-Charge. |
| 35 | Taking up or down 15 mm bore steel tubing and connections |
| 36 | Ditto all as per ser item No 35 above but 20 mm bore tubing |
| 37 | Supplying and laying 16 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings complete all as specified. |
| 38 | Ditto all as per Ser item No 37 above but 20 mm bore tubing |
| 39 | S & F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified. |
| 40 | S&F in repairsfancy type stop cock/ anglecock/ two way cock cast copper alloy, Chromium plated fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge |
| 41 | Supply and fix in repairs tubular towel rail, brass chromium plated 20 mm dia `D\"type, 60 cm long between flanges including a pair of bracketsall as directed. |
| 42 | S&F in repairsbib tap 15 mm dia, fancy type CP cast copper alloy with crutch or butterfly handlescrewed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F in repairs fancy type twin (Two way) bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handlescrewed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply only 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe all as directed. |
| 45 | Supply only PVC flexible 32 mm Waste pipefor WHB, Sink etc complete all as specified. |
| 46 | S&F in repairPVC (SWR) 110mm bore (dia) soil, waste and vent Pipe, (ISI Marked), in any length with rubber ring Joints fixed to wall with necessary stay clamps/ laid in trenches/ floor etc complete all as specifed and directed. |
| 47 | .-Ditto- all as per ser item No 46 above but as in trenches or floor |
| 48 | S&F in repairPVC (SWR) 75mm bore (dia) soil, waste and vent Pipe, (ISI Marked), in any length with rubber ring Joints fixed to wall with necessary stay clamps/ laid in trenches/floor etc complete all as specifed and directed. |
| 49 | .-Ditto- all as per ser item no 48 above but as in trenches or floor |
| 50 | S&F PVC (SWR) 110 mm bore (dia), Bends any type, etc. and Jointing with Solvent Cement, complete all as specified and as directed |
| 51 | S&F PVC (SWR) 75mm bore (dia), Bends any type, etc. and Jointing with Solvent Cement, complete all as specified and as directed |
| 52 | S&F PVC (SWR) vent cowl 110mm bore |
| 53 | S&Frotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, triple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe, tank nippleand connected complete all as directed. |
| 54 | S&F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball and high density plastic ball screwed to iron pipe, tank nippleand connected (Minimum weight 15mm-142Gms/20mm-210Gms) complete all as directed. |
| 55 | Cutting chases in brick/ block wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth |
| 56 | Taking down chowkhats or frames not exc.1.5 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directedby Engineer-in-Charge |
| 57 | Taking down chowkhats or frames exc. 1.5 sq. m and n exc 4.00 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directedby Engineer-in-Charge |
| 58 | Taking down shutters of any description exc 1 Sqm but n exc 2 Sqm each etc complete all as specified and directedby Engineer-in-Charge |
| 59 | S & F Pressed steel door frame of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hings, lock strike plate, etc, complete all as specified, |
| 60 | S&F 35 mm thick IInd C/L H/Wglazed & skeleton shutters open rebated and prepared to receive glass gauge, divided into square or rectangles with plain chamfered or rounded mitered & rebated slash bars including beads mitered for securing glass wire gauge etc all as specified |
| 61 | M&L for 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated |
| 62 | S&F Solid PVC Door frame size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing |
| 63 | S&F factory made solid PVC moulded Door shutter with particle board core, 28 to 30mm thick (stiles) with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back space, supplying and fixing in frame at site as per specification & drawing. |
| 64 | S&F powder coated aluminium anodised aluminium frame, shutters fordoor,windows, ventilators with one or more rebates including joining cleat for fixing etc,rubber/ neoprene beading andlocking arrangementetc complete all as specified and directed by Engr-in-Charge |
| 65 | S&F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 66 | S&F butt hinges medium weight cold rolled mild steel 100mm long. |
| 67 | S&F aluminium anodised barrel tower bolts of extruded section 150mm long. |
| 68 | S&F aluminium anodised handle of extruded section 150mm long. |
| 69 | S&F aluminium alloy, anodised, sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 300mm long. |
| 70 | S & F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge. |
| 71 | S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge. |
| 72 | S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. |
| 73 | Hacking out old broken glass(any thickness size, quality or description ) from wooden/Steel frames glazed with putty or fixed with beads. |
| 74 | M&L for 3 mm thick sheet frosted/ pin headed glass ordinary quality and glazing withoilputty orwoodenbeads in squares n.exc 0.50 sqm in each pane. |
| 75 | M&L for preparation of new wooden surface and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed. |
| 76 | M&L for preparation of old wooden surface and applying one coat of synthetic enamel paint. |
| 77 | M&L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide. |
| 78 | M&L for preparation of old steel surface and applying one coat of synthetic enamel paint. |
| 79 | S & F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. |
| 80 | S&F curtain rod 20mm dia, having corrugated PVC extrusion on eletric resistance welded MS pipe with fancytype 02 nos Knobs and 02 Nos brackets per each door/ windowsetc complete all as specified and directed |
| 81 | S&F pegs set of 6 Nos, power coated a/u body fixed with cadmium plated screws as directed. |
| 82 | S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent cement. |
| 83 | S&F Chromium plated soap dish of Prayag polymers Pvt Ltd or equivalent. |
| 84 | Dismantling of framed timber scantling 40 Sq, Cm and over in section, in any position |
| 85 | M&L for 0.80mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed fixed with L-type or J-type or cranked hook bolts in lieu of screws and washers, in roofs, walls etc. with grade of zinc coating 275.including dismantling existing sheets etc complete all as directed |
| 86 | M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet of any colour 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners. including dismantling existing sheets etc complete all as directed |
| 87 | Dismantling of single layer Mangalore pattern or similar tiles in roofing |
| 88 | M&L for roof tiles, Mangalore pattern, interlocking at side joints, laid dry |
| 89 | Fixing only for roof tiles, Mangalore pattern, interlocking at side joints, laid dry |
| 90 | M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 |
| 91 | Dismantling of battens for tiles, shingles etc, of any size including tilting fillets spacing exc 15 cm |
| 92 | M&L for 2nd class hardwood clean sawn battens at 30 Cm centres sectinal area exc 5 & n exc 15 Sq cm |
| 93 | Fixing only 2nd class hardwood clean sawn battens at 30 Cm centres sectinal area exc 5 & n exc 15 Sq cm |
| 94 | Dismantling of unframed work fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section |
| 95 | M&L for 2nd class hardwood plain fillets.square, rectangular or triangular in section, clean sawn, secured with screws or brads sectinal area exc 13 & n exc 25 Sq cm |
| 96 | Fixing only 2nd class hardwood plain fillets.square, rectangular or triangular in section, clean sawn, secured with nails or brads sectinal area exc 13 & n exc 25 Sq cm |
| 97 | S&F in repairs forfalse ceiling with Vinyl faced Arm-Gyp-FB, ceiling 600 x 600 x 9mm thick with washable metalized polyester foil backing with Vinyl covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wirefixed to roof at 600mm centre to centre as per manufacturer\"s instructions / specification andall as directed including taking down/ out existing. |
| 98 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 99 | S&F of steel work of grade ST 240 in Square/ Rectangular tubes confirming to IS 4923-2017 or circular section confirming to IS 1161-2014 as in post, trusses, purlin, rafter, bracing etc including weldingand providing special shaped washer etc complete all as specified and directed by Engr-In-Charge |
| 100 | S&F of steel work in post, Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. as perFe 410 -W (Gde- E- 250) quality- A |
| 101 | S&F structural rolled mild steel Fe 410-00 (Gde E-250) Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 102 | M&L for Providing cement concrete Type C1 1:3:6 20mm graded aggregate) in kerbs or mud stops, rounded or chamfered on edges |
| 103 | Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Charge. |
| 104 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 12 module suitble for Mylinc series of Legrand including white plates with frame upto 12 module of make suitable for Mylinc Series )for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed.Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2.All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 105 | One light point or fan point controlled by switch5 Amp single pole one way |
| 106 | One bell point controlled by one switch5 Amp single pole, one way on independent board |
| 107 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 108 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 109 | All as per Item No 104(here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 110 | S&F in replacement bell ding dong elelctric 230V ACsingle pole etc complete all as specified and directedby Engineer-in-Charge |
| 111 | S&F in replacement Modular Switch, 6 Amp, one way, one Module as per existing.etc complete all as specified and directedby Engineer-in-Charge |
| 112 | S&F in replacement Modular Switch, 16 Amp, one way, one Module as per existing. etc complete all as specified and directedby Engineer-in-Charge |
| 113 | S&F in replacement Modular Socket Outlet6 Amp,3 pin, combined two module etc as per existing complete all as specified and directedby Engineer-in-Charge. |
| 114 | S&F in replacement Modular Socket Outlet6 Amp / 16 Amp - 2/3 pin combined two moduleas per existing etc complete all as specified and directedby Engineer-in-Charge |
| 115 | S&F in replacement Modular Bell push, 6 Amp, one module etc complete all as specified and directedby Engineer-in-Charge |
| 116 | S&F in replacement ModularFan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directedby Engineer-in-Charge |
| 117 | Supply & fix lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directedby Engineer-in-Charge |
| 118 | S&F ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directedby Engineer-in-Charge |
| 119 | S & F Double doorSheet metal enclosures factory made DBs6 way TPN, 415 voltsConcealed in Wall, protection class IP-42, suitable for fixing of MCBs etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.Note:- MCCBs/ MCBs DP/TPN will be measured and paid separately. |
| 120 | S & F in replacement double doorSheet metal enclosures factory made DBs SPN, 8 way, 240 volts, protection class IP-42, suitable for fixing of MCBs,, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 121 | Supply & fix MCB , DP, AC, 415 Volts of 40 Amp capacity 10 KA, \"C\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge |
| 122 | Supply & fix MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 10KA, \"B\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge |
| 123 | Supply & fix MCBs, TPN, AC, 415 volts of 63 Amps capacity 10 KA, \"B\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge |
| 124 | Supply & fix MCBs, SPN, AC, 240 volts of 40 Amps capacity 10 KA, \"C\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge. |
| 125 | Supply and fix Industrial type ultra slim square profile LED lighting fixture, environmental friendly, energy efficient ready to use pack Industrial type LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cableof size 0.5 Sqmm withcompletewith all accessories etc complete all as specified and directedby Engineer-in-Charge. |
| 126 | Supply & fix energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directedby Engineer-in-Charge |
| 127 | S&F sub main wiring with two single core PVCinsulated, unsheathed, FRLSH stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn throughand including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directedby Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit. |
| 128 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts& washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precostRCC(1:2:4)mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC,both way, lifting arrangement complete including all necessaryearth work etc complete all as specified and directedby Engineer-in-Charge |
| 129 | M&L for Supply, laying, connecting, testing and commissioning and jointing, LT underground cable in replacement, 1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/ walls with proper size saddles and clamp complete all as specified and as directedby the Engineer-in-Charge ofSizes:-(a) LT cable 16 Sqmm, 4 core.Note :-Excavation & Earthwork, Protection pipe etc shall be measured and paid seprately under relevent items of this Schedule. |
| 130 | Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge |
| 131 | Returnig, filling in including spreading, levelling, watering and well ramming in layers, n exc 25 cm thick in soil etc complete all as specified and directed by Engineer-in-Charge |
| 132 | Removing exacavated soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge |
| 133 | Supply &lay HDPE pipe 50 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge |
| 134 | Supply and fix exhaust fan, PVC body AC single Phase, 230V of size 200 mm sweep with, blades and frame and louvers completeall as specified and directed. |
| 135 | Taking out/ downand opening of existing ceiling fans 1200 mm sweep/ exhaust fan of any size/electric meter from any position, of any make etc & refixing at the desired location after reassembling andafter servicing/ overhauling by thouroghly cleaning the shaft, rotor, stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair / replacement of spare parts/ material /items, making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/ lubricant etc to make it functional complete all as specified and as directed. |
| 136 | M&L for preperation of ceiling fans 1200 mm sweep/exhaust fan of any size/electric meter of any make by cleaning of metal surfacesincluding painting with spray painting on required gloss with white synthetic enamel paint on complete body of fans and writing MES No with black synthetic enamel paint etc complete all as specified anddirected by Engineer-in-Charge |