| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-01-2026 | New Tender pages file | Technical Bid | 27-01-2026 |
| 2 | 16-01-2026 | BOQ revised | BOQ | 27-01-2026 |
| 3 | 16-01-2026 | REVISED DATE | Date | 27-01-2026 |
| Sl. No. | Item Description |
| 1 | B/R Work |
| 2 | Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed |
| 3 | Dismantling asbestos cement (corrugated/semi corrugated) in roof coverings, etc including ridges, claddings, etc. including all necessary staging / scaffolding, etc. as required and disposing off complete all as specified and as directed |
| 4 | Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed |
| 5 | Dismantling wall and ceiling boards (fibre,pulp, insulation, etc. or insulation boards/slabs/blankets, any thickness including cover fillets, frameworks, etc. complete all as specified and as directed |
| 6 | Surface dressing not exceeding 15cm deep and getting out in soft/loose soil complete all as specified and as directed |
| 7 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed |
| 8 | Excavation over areas not exceeding 1.5m deep and getting out in any type of soil complete all as specified and as directed |
| 9 | Excavation over areas exceeding 1.5m deep but not exceeding 3.00m deepand getting out in any type of soil complete all as specified and as directed |
| 10 | Excavation in trenchesnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed |
| 11 | Excavation in trenchesexceeding 1.5m wide and not exceeding 3.00m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed |
| 12 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed |
| 13 | Removing excavated materialsto a distanceexceeding 1.5Km but not exceeding 5.00km and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed |
| 14 | M&L forearth filling under flooring including spreading, levelling & well ramming including watering as required not exc 25cm thick, complete all as specified and as directed |
| 15 | M&L for forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30cm thick, watering, ramming/ rolling and finishing to required size, shape, etc. not exceeding 1.5m high from base complete all as specified and as directed |
| 16 | M&L for treating the backfilling in contact with foundationat the rate of 7.5 litres of anti termite per sqm of surface area, complete all as specified and as directed. |
| 17 | M&L for treating the top surfaces of filled earthat the rate of 5 litres of anti termite per sqm of surface area, complete all as specified and as directed. |
| 18 | M&L for treating the soil under plinth protectionat the rate of 5 litres of anti termite per sqm of surface area, complete all as specified and as directed. |
| 19 | M&L for treating the soil along with external perimeterof the building at the rate of 5 litres of anti termite per sqm of surface area, complete all as specified and as directed. |
| 20 | Material and labour for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding15 cm thick, watered and rammed to a true surface, etc complete all as specified and directed. |
| 21 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick ,spread, levelled ,rammed and consolidated to required gradient and camber with 0.2 to 0.5 tone hand roller including watering complete all as specified and directed. |
| 22 | M&L for sand filling under floors or in foundations including watering, ramming and consolidation, complete all as specified and as directed. |
| 23 | M&L for loose filling with broken brick aggregates of gauge 40 to 80mm in soakage pits, soakage wells, etc. complete all as specified and as directed |
| 24 | M&L for use and waste formwork to sides of concrete foundations, bases of columns, rafts, raft beams, plinth beams and similar works, vertical or to batter, for rough finished flat surfaces of concrete complete all as specified and as directed |
| 25 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed |
| 26 | M&L for formwork to soffits of suspended slabs, such as roof slab, floor slab, landings and similar works not exceeding 200mm thick for rough finished flat surfaces of concrete complete all as specified and as directed |
| 27 | M&L for formwork to sides and soffits of floor or roof beam, beam haunching, girder, lintels, cantilever, shelves including supports, etc. for rough finished flat surfaces of concrete complete all as specified and as directed |
| 28 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 200mm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 100mm but not exceeding 200mm wide complete all as specified and as directed |
| 29 | M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as foundation filling, mass concrete, etc. complete all as specified and as directed |
| 30 | M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate for bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100mm dia drain pipes complete all as specified and as directed |
| 31 | M&L for plain cement concrete 1:3:6 (type C-1) using 20mm graded stone aggregate as in beds of drains, surface channels, foundations of manholes, etc. complete all as specified and as directed |
| 32 | M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate for bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia drain pipes complete all as specified and as directed |
| 33 | M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in floors, sub-bases, pavings, etc. surface finished even and fair complete all as specified and as directed |
| 34 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in foundation, filling and mass concrete ,complete all as specified and as directed |
| 35 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in bed blocks, back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed |
| 36 | M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed |
| 37 | M&L for plain cement concrete type B-0, 1:2:4 (using 12.5mm gradedstone aggregates) as in haunching roof kerbs, levelling courses, etc. complete all as specified and as directed |
| 38 | M&L for pre-cast reinforced cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in cover slabs for valve chambers, manholes, chullah hoods, chajjas, water troughs, shelves and similar articles, with plain faces, set in CM 1:4 complete all as specified and as directedNote: Reinforcement will be measured and paid separately under relevant item here-in |
| 39 | M&L for 40mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregates) as in roof padding, haunching, roof kerb or similar works including applying 3kg/sqm neat cement slurry complete all as specified and as directed. |
| 40 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping, benching, etc. including neccessary formwork complete all as specified and as directed |
| 41 | M&L for extra in forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directedNote: Inner girth shall only be measured |
| 42 | Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm in girth complete all as specified and as directed |
| 43 | M&L RCC M 25 design mix as in foundations including rafts, footings, foundation beams, plinth beams, column footings, under reamed piles, mass concrete, etc. complete all as specified and as directed |
| 44 | M&L RCC M 25 designmix as in columns, pillars, posts, etc complete all as specified and as directed |
| 45 | M&L RCC M 25 design mix as in bands, beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed |
| 46 | M&L RCC M 25 design mix as in slab supported on walls,beams and column in floors, roof, loanding, balconie, canopies, deck slab and in shelvesand like etc complete all as specified and as directed |
| 47 | Notes for serial item Nos. 43 to 46: (a) Mix design shall be conforming to relevant IS. Design mix shall be got designed from National Test House, SEMT Wing CME, Regional Research labs, IITs, National Institutes of Technology, Command Test Laboratory and Govt Engineering Collage and shall be got approved by the GE. Cost of obtaining design mix shall be included in the quoted rates (b) The Contractor shall use only one type brand of cement for entire structural/reinforced concrete work. In the event of contractor desiring use of any different brand of cement, fresh design mix shall be carried out and submitted for approval without any extra cost to the Govt.(c) Reinforcement steel will be measured separately under respective items herein |
| 48 | M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in beams, cantilevers, lintels, etc. over 1.5m long complete all as specified and as directed |
| 49 | M&L for RCC (nominal mix) 1:1.5:3 type A-1 using 20mm graded mechanically crushed stone aggregates as in slabs supported on walls, beams and columns, in floor, roof, landing, balconies, shelves and the like complete all as specified and as directed |
| 50 | M&L for RCC (nominal mix) 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregates as in slabs supported on walls, beams and columns, in floor, roof, landing, balconies, shelves and the like complete all as specified and as directed |
| 51 | M & L for brickwork with sub-class \"B\" bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed |
| 52 | M & L for brickwork with sub-class \"B\" bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed |
| 53 | M & L brickwork with sub-class `B\" bricks in one brick thick honeycomb walling built in cement mortar 1:4 complete all as specified and as directed |
| 54 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.18sqm but not exceeding 0.38sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed |
| 55 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.18sqm but not exceeding 0.38sqm each, 7 to 8mm thick of superior quality as in vertical surfaces, dado, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles, fixed over and including 10mm thick backing coat in CM (1:4) (rate shall be included) complete all as specified and as directed |
| 56 | M&L for laying machine pressed precast concrete 80mm thick rubber moulded, designer, interlocking paver blocks made of M-35 design mix concrete of approved design and shape with the crushing strength not less than 350kg/sqcm conforming to IS: 15658-2006, and filling the joints with sand including all necessary cutting, notching etc., complete all as specified and as directed |
| 57 | M&L for rendering 5mm thick in cement mortar (1:3) on fair surfaces of concrete surfaces of ceilings, soffits of slabs, etc. finished fair and even without using extra cement complete all as specified and as directed |
| 58 | M&L rendering 10mm thick, in cement mortar (1:6) on walls / concretesurfaces, etc. finished even and fair without using extra cement complete all as specified and as directed |
| 59 | M&L rendering 12mm thick, in cement mortar (1:6) on walls / concretesurfaces, etc. finished even and fair without using extra cement complete all as specified and as directed |
| 60 | M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directedNote: WPC will be measured and paid separately under respective item herein |
| 61 | M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. finished even and smooth without using extra cement complete all as specified and as directed |
| 62 | Supply only integral water proofing compound all as specified |
| 63 | M&L for applying polythene film 150 micron thick, laid on a coat of bitumen primer @0.30 to 0.50Kg per sqm, complete all as specified and as directed. |
| 64 | M&L for bitumen blown any grade,applied hot, two coats to concrete surfaces at the rate 1.5Kg/sqm per coat , complete all as specified and as directed. |
| 65 | Supply and laying APP based polymeric membrane 3mm thick (minimum), weighting not less than 3.5 kg/sqm reinforced with polyester non woven fabric (weighting not less than 160gms/sqm) applied over primed surfaces by torching application as per manufacturer\"s instructions with overlaps minium 100mm on the transverse directions and 75mm in longitudinal directions, including one coat of bituminous primer over the APP modified membrane @0.11 Kg/Sqm complete all as specified and as directed |
| 66 | M&L for cleaning and applying one coat of cold bituminous primer (as approved by GE) @0.25litre/sqm over dried up surfaces of concrete / plastered surfaces conforming to IS 3384-1986 complete all as specified and as directed |
| 67 | S & F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed |
| 68 | S&F bands, straps, hold fasts, wall ties, cleats, supports or stays of RWPs, ventilation pipes and similar articles of mild steel conforming to Fe-290 grade E-165 including bolts as required complete all as specified and as directed |
| 69 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 70 | M&L for mild steel TMT bars grade Fe-500D, 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 71 | M&L for mild steel TMT bars grade Fe-500D, 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 72 | M&L for mild steel TMT bars grade Fe-500D, 5mm dia and over upto 10mm dia, as in stirrups, spacers, etc. cut to length, bent to shape required including cranking, bending spirally for hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 73 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated / semi-corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering, cladding to walls, etc. fixed with self tapping screws complete all as specified and as directed |
| 74 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering, cladding to walls, etc. fixed with self tapping screws complete all as specified and as directed |
| 75 | S&F 4mm thick asbestos cement plain building boards, fixed to timber framework on ceilings with screws and applying one coat of white wash ,complete all as specified and as directed |
| 76 | S&F stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with wooden beeds, complete all as specified and as directed |
| 77 | M&L for 2nd class hard wood timber scantling wrought in section, timber framed & fixed complete all as specified and as directed |
| 78 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width, stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed |
| 79 | S&F 3 way sliding anodised aluminium glazed window shutter with frame with the following specifications complete all as specified and as directed.(a) Frame 50x65x1.5mm thick(b) 35x35x1.5mm Z section in stiles, rails(c) 50x35x1.5mm T section mullion(d) PVC gasket and with 4.0mm thick coloured glass pane one side mirror finished, area not exceeding 0.5sqm each with aluminium handles and necessary locking arangements(e) Stainless steel wire mesh for mosquito proofing arrangement all as directed |
| 80 | S&F 2 way sliding anodized aluminium glazed ventilator shutter with frame consists of following specification complete all as specified and as directed:(a) Ventilator frame 2 track of size 60x25x1.5mm thick(b) Stiles and rails of size 35x25x1.5mm(c) 35x35x1.5mm T section mullion(d) PVC gasket with 4mm thick tinted glass, including aluminium handles with necessary locking arrangement |
| 81 | Notes for item Nos. 79 & 80: (a) Area of opening shall only be considered for meaurement purposes (b) All necessary accessories including tinted glass, PLPB, fittings, fixtures for assembling / fixing as per drawing complete shall be included in the quoted rate |
| 82 | S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges complete all as specified and as directed |
| 83 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed |
| 84 | S&F 35mm thick 2nd class hard wood glazed and skeleton door shutters, open rebated without sash bars, with plain, chamfered or rounded, mitred, any number of panels, prepared to receive glass, gauges, etc. edges chamfered or rounded, sizes of members of shutters as specified in clause 8.24(a) of SSR Part-I, supplied and fitted to chowkhats complete all as specified and as directed |
| 85 | S&F 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed |
| 86 | S&F 100mm long stainless steel butt hinges of selected quality, with stainless steel hinge pin fixed with stainless steel screws complete all as specified and as directed |
| 87 | S&F 300mm aluminium alloy, anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed |
| 88 | S&F200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed |
| 89 | S&F in repairs 25mm dia fancy type MS chromium plated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of brackets, holders with funnel at ends complete all as specified and as directed |
| 90 | S&Fvitreous China squatting pan, Orissa pattern of size 580x440mm, white, with integral foot rests and \"P\" or \"S\" trap, connecting to flushing pipe and trap and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing complete all as specified and as directed. |
| 91 | S&F vitreous China urinal, bowl type half stall urinal flat back, of size 465x355x265mm white, with grating and union for discharge pipe (back or corner wall type), including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in white cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed |
| 92 | S&F wash hand basin, vitreous China, white, counter top type, of size 560x461mm, oval shaped, of approved design, with waste coupling and including PVC connection 60cm key with brass union complete all as specified and as directed |
| 93 | S&F 10 litre capacity PVC valveless syphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets complete all as specified and directed. |
| 94 | S&F steel water tubing 15mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 95 | S&F steel water tubing 20mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 96 | S&F in repairs 15mm bib taps, chromium plated, cast copper alloy with crutch or butter fly handle,long neck, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed |
| 97 | S&F in repairs 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered \"HOT\"/\"COLD\", with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed |
| 98 | S&F in repairs 15mm dia stop cocks / angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed |
| 99 | S&F in repairs gun metal globe or gate valve, 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed |
| 100 | S&F 600x450mm full sized bevelled edge mirror of selected quality glass mounted on 6mm thick commercial plywood with PVC beading all round and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed |
| 101 | S&F 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed |
| 102 | S&F in repairs towel rail, 20mm dia, brass chromium plated, 600mm long with fancy type with brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs complete all as specified and as directed |
| 103 | S&F125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45o with flange of CP brass complete all as specified and as directed |
| 104 | S&F 12mm thick glass corner shelf, 250mm radius bewteen flanges fixed with brass chromium plated D clamps including brackets complete all as specified and as directed |
| 105 | S&F 75mm dia PVC (SWR) floor trap with chromium plated grating jointed with solvent cement complete all as specified and as directed |
| 106 | S&F in repairs PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls or laid in trenches/floor with suitable clamps, in weep hole etc. complete all as specified and as directed |
| 107 | S&F in repairs PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls or laid in trenches/floor with suitable clamps, etc. complete all as specified and as directed |
| 108 | S&F in repair 110mm bore PVC (SWR) bend of any radius complete all as specified and as directed |
| 109 | S&F in repairs 75mm bore PVC (SWR) bend of any radius with oval access door complete all as specified and as directed |
| 110 | S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal with or without access door complete all as specified and as directed |
| 111 | S&F 75mm dia PVC (SWR) vent cowl complete all as specified and as directed |
| 112 | S&F110mm dia PVC (SWR) vent cowl complete all as specified and as directed |
| 113 | M&L for preparation of masonry / concrete wall surfaces and applying1mm thick wall care putty rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 114 | M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on walls, etc. complete all as specified and as directed |
| 115 | M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on ceilings, etc. complete all as specified and as directed |
| 116 | M&L for preparation of new masonry / concrete wall surfaces and applying two coats of oil bound distemper over a coat of wall primer including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 117 | M&L for preparing of new wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed |
| 118 | M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed |
| 119 | M&L for preparation of new plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed |
| 120 | E/M WORKS |
| 121 | Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making good the disturbed surfaces, etc. complete all as specified and as directed |
| 122 | Taking down main switches, sheet metal enclosures, DBs by disconnecting and blanking supply mains from any location/position and disposing off complete all as specified and as directed |
| 123 | M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for One light pointcontrolled by one 5A one way switch |
| 124 | M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for One ceiling/exhaust fanpoint controlled by one 5A one way switch |
| 125 | M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for One switch socket outlet 3 pin 5A controlled by one switch on same board |
| 126 | M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for One switch socket outlet 3 pin 5A controlled by one switch on independent board |
| 127 | M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC casing caping not less than 20mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed |
| 128 | S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed |
| 129 | S&F switch piano flush , single pole, ISI marked, one way 6A,230V complete all as specified and as directed |
| 130 | S&F switch piano flush , single pole, ISI marked, one way 15A,230V complete all as specified and as directed |
| 131 | S&F switch socketoutlet, 2 in 1, 3 pin, 5 A flush type, ISI marked, 230V complete all as specified and as directed |
| 132 | S&F switch socketoutlet, 2 in 1, 3 pin, 15 A flush type, ISI marked, 230V complete all as specified and as directed |
| 133 | M&L for submain wring using proper colour codingwith 2 runs of single core, PVC insulated,FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 1.5sqmm and 1 run of 1.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing capping 32mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directedNotes:(i) 2 runs of 1.5sqmm main cable, 1 run of earth conductors and 1 run of PVC casing/capping shall be measured as one length(ii) Separate casing shall be used for each sub-main wiring circuit irrespective of numbers of wire(iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site |
| 134 | M&L for submain wring using proper colour codingwith 2 runs of single core, PVC insulated,FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing capping 32mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directedNotes:(i) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC casing/capping shall be measured as one length(ii) Separate casing shall be used for each sub-main wiring circuit irrespective of numbers of wire(iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site |
| 135 | S&F LED batten with inbuilt driver made out of high qulaity aluminiu8m extruded housing and aluminium heat shrink for mounting LEDs, mercury free and decirativeend caps with maximum power consumption 9-10watt with min system lumious efficiency lumen/watt> 100 CT not less than 5700k and CRI>80, operating voltage of 140-270Volt AC, P.F > 0.90, 2.5KV surge protection and current THD <15% complete and including all other accessories as per manufacturer instruction, internally prewired including connecting up with twin core 0.75sqmm copper conductor flexible wire / cable , complete all as specified and as directed . |
| 136 | S&F BLDC ceiling fan 1200mm sweep, 230V, minimum air delivery 210CFM with service value 6.00 BEE 5 star rated, with blades, down rods and accessories and connecting up including disconnecting, taking down of old unserviceable fan and depositing to MES storeyard including all loading, unloading, carting, etc. complete all as specified and as directed |
| 137 | S&F heavy duty, PVC body with PVC blades, legs, ISI marked energy efficient exhaust fan,300mm sweep, 230V, 50Hz, 1200RPM, copper wound, with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts complete all as specified and as directed |
| 138 | S&F building security light, LED luminaire 30W IP-66 protection class, with 25W LED lamp, driver, etc. with all accessories complete all as specified and as directed |
| 139 | S&F angle bracket of 40mm dia GI tube light grade for fixing building security lightof 1m long, complete all as specified and as directed. |
| 140 | S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed |
| 141 | S&F sheet metal enclosures for 4 way MCB DB, 240V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed |
| 142 | S&F MCB SPN, 240V, 40 to 63A, 10kA, 50Hz, C curve complete all as specified and as directed |
| 143 | S&F MCB SP, 240V, 5 to 32A, 10kA, 50Hz, C curve complete all as specified and as directed |
| 144 | S&F in repairs MCB isolator TPN, 240V, 63A, 10kA, 50Hz, B curve complete all as specified and as directed |
| 145 | Excavation in trenchesnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed |
| 146 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed |
| 147 | Removing excavated materialsto a distanceexceeding 1.5Km but not exceeding 5.00km and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed |
| 148 | M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directedNote: Only punned thickness of sand shall be considered for measurement purposes |
| 149 | Supply and laying burnt bricks of sub-class \"B\" designation 75 of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 150 | Supply, fixing, commissioning and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductors, 1100V grade 4 core 16 sqmm laid in trenches/fixed to wall/under road/drawn through pipes etc. with copper cable glands and copper thimbles including taking down old unsv cables, complete all as specified and as directedNote: Excavation and earthwork will be measured and paid under respective items herein |
| 151 | S&F steel water tubing, light grade, 40mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc.including taking down old usv GI pipe, complete all as specified and as directed |
| 152 | M&L for 100mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate asflooring, etc.complete all as specified and as directed |
| 153 | S&F gun metal globe or gate valve, 25mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed |
| 154 | S&F steel water tubing, medium grade, 25mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc.including taking down old usv GI pipe, complete all as specified and as directed |
| 155 | M&L for cutting into existing 25mm bore GI pipes in position and any location for insertion of tees, tail piece, collars, branch pipes, reducers, etc. at any required length for branch connection, etc. complete all as specified and as directedNotes: (a) Excavation and earthwork will be measured and paid separately under respective items herein(b) Both sides cut shall be measured as one unit |
| 156 | S&F in repairs MCCB 40A, 3 Pole, 415V, AC, Ics=100%Icu, 80 to 100% overload protection, adjustable type, with thermal magnetic release mechanism, breaking capacity 16kA including all necessary lugs, wire, etc. required for connecting up including FRP box for enclosure of size 250x250x160mm alongwith cable gland, fitting anf fixtures, complete all as specified and as directed |
| 157 | M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directedNotes: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included(ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item(iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy