| 1 | Dismantling Brick tiles or terracing tiles, single layer on roofs; Complete all as specified and as directed. |
| 2 | Demolition mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof); Complete all as specified and as directed . |
| 3 | Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in padding concrete fair finish of required thickness on roofs, roof kerbs or mud stops, rounded or chamfered on edges and like including weathering slight rounded and throating; Complete all as specified and as directed. |
| 4 | Material & Labour for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric( wt. notless than 150 gms/sqm) land on primed surface by forced application complete all as specified and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces Complete all as specified and as directed.Note: Sheet should be five layered prefabricated Atactic Polypropyleen Polymer (APP) modified 3 mm thick membrane (weighing not less than 3 kg/sqm) reinforced with 160 gsm polyester non- woven fabric. Concrete of roof surface shall be scratched with scratched tool before finishing roof surface when the concrete surface is still green,10mm thick 1:4 cement plaster shall be laid .The roof surfaces shall be throughly wire brushed, washed, dried up and cleaned to all foreign matter nd dust prior to the appliction of primer. On the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 40 to 160 CPS, manufactured by same manufacturer @ 0.4 litre / sqm shall be applied. APP membrane shall be laid on primed surface by torch application method after allowing 24 hours for primer to dry . Laying off APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100mm on longitudinal direction and 150 mm on the transverse direction. all overlaps shall be bonded with bitumen primer and levelled by heating the overlaps with brutane torch. the treatment shall be done by the approved authorised applicatiors. |
| 5 | Material and Labour for 40mm thick brick tiles, laid on and including 15 mm thick cement mortar 1:6 and joints grouted and pointed flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement; Complete all as specified and as directed. |
| 6 | All as per Srl Item No. 05 here-in-before but except brick tiles. Note:-Old serviceable tiles shall be reused. |
| 7 | Disconnecting existing tanks, exc 250 and n exc 500 ltrs capacity setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning repairing, etc Complete all as specified and as directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises Complete all as specified and as directed. |
| 9 | Supply & Fixing non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in cement mortar 1:6 & complete all as specified and directed. |
| 10 | Supply & Fixing glazed ceramic coloured tiles 450x300mmx6mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in cement mortar 1:4 on brick surface complete all as specified and directed. |
| 11 | Demolition of Brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles Complete all as specified and as directed. |
| 12 | Material & Labour for brick with sub class B bricks old size built in cement mortar 1:6 complete all as specified and directed |
| 13 | All as per Srl item No. 12 but except bricks using old serviceable bricks. |
| 14 | Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 15 | Material & Labour for rendering 15 mm thick on brick work or concrete surfaces on walls in cement mortar 1:6 finishing even and smooth without using extracementcomplete all as specified and directed. |
| 16 | Material & Labour for rendering 15 mm thick on brick work or concrete surfaces on walls in cement mortar 1:4 finishing even and fair surface without using extracementcomplete all as specified and directed |
| 17 | Material & Labour for rendering 10 mm thick on brick work or concrete surfaces on ceiling in cement mortar 1:3finishing even and smooth without using extracement complete all as specified and directed. |
| 18 | Material & Labour for applying two coats of whitewash on ceiling including preperation of newly plastered surfaces complete all as specified and directed. |
| 19 | Material & Labour for applying one coat of whitewash on ceiling including preperation of oldplastered surfaces complete all as specified and directed. |
| 20 | Material & Labour for applying two coats of whitewash on wall including preperation of newly plastered surfaces complete all as specified and directed. |
| 21 | Material & Labour preparation of old surfaces (plastered or unplastered) of walls including cornices by brooming down or steel wire brushes, scrapping down smoke soot moulds moss and efflorescent salts, trading oil cut greasy spots and applying one coat of oil bound distemper on walls complete all as specified and directed . |
| 22 | Material & Labour for preparation of NEW plastered surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 23 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 24 | Material & Labour 75mm thick plain Cement concrete type D2, 1:4:8 using 40mm graded crushed stone agregate asin sub base of floor complete all as specified and directed. |
| 25 | Material & Labour for Machine cut Kota stone slab flooring 20-25 mm thick (size not less than 0.5 sqm each) over cement screed baseof 15mm thick in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified. |
| 26 | All as per srl Item No 25 here-in-before but as skirting/dado over rendering 15mm thick in cement mortar 1:4. |
| 27 | Supply & Fixing factory made 35 mm thick flush shutters solid core construction with block board core and plywood face panels complete all as specified and directed. |
| 28 | Material & Labour PCC 1:1.5:3 type B0 using 12.5 mm graded stone aggregate minimum 25mm thick for repair of Chajja, Fascia, etc. using chicken wire mes upto 8 m height including necessary formwork, scaffolding, and applying two coats of cement base paint over 5mm cement plaster 1:3 complete all as specified and directed. |
| 29 | Supply & Fixing galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed screws or beading in steel/ wooden door / window complete as specified and directed. |
| 30 | Supply & Fixing in repair of Vitreous china wash down water closet pan( pedestal pattern), white with PVC(SWR) \"P\" trap 110/110mm bore incliding seat cover complete all as specified and directed. |
| 31 | Supply & Fixing in repair 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve flote handle including bracket and flush pipe of polythylene of low or high density or PVC,32mm dia complete all as specified and directed. |
| 32 | Supply & Fixing in repair PVC Jet spray suitable for EWC complete all as specified and directed. |
| 33 | Supply & Fixing in repair PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 34 | Supply & Fixing in repair vitreous china urinal half stall type with CP spreader white incl CP waste coupling with grating and union fordischarge pipe, including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement fixing with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed. |
| 35 | Supply & Fixing in Repair vitreous China wash basinwhite,oval type including CP waste coupling 32mm bore,waste PVC pipe complete,CP brass Pillar Tap 15mm bore of fancy type complete all as specified and directed. |
| 36 | Supply and fixing in repair15mm bore type anglecock cast copper alloy CP screweddown high pressure with crutch or butterfly handle complete all as specified and directed. |
| 37 | Supply & Fixing in repair of brass cromium brass plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass complete all as specified and directed |
| 38 | Supply & Fixing in repair PVC wastepipe32mm dia fixed to WHB/Urinals complete all as specified and directed. |
| 39 | Supply & Fixing in repair 8mm thick bevelled edge mirror of selected quality glass,mounted on CP stud including drilling cutting and fixed to wall complete all as specified and directed. |
| 40 | Supply & Fixing in repairs 125mm CP shower rose fancy type with CP arm complete all as specified and directed. |
| 41 | Supply & Fixing in repair PVC (SWR) pipe 75mm dia fixed in wall/floor complete all as specified and directed. |
| 42 | Supply and fixing in repiar PVC (SWR) pipes single110mm socketed, in any length with rubber ring joints, laid in trenches or in floors/wall complete all as specified and directed. |
| 43 | Supply & Fixing in repair 75mm PVC (SWR) bends any radius complete all as specified and directed. |
| 44 | Supply & Fixing in repair 110mm PVC (SWR) bends any radius complete all as specified and directed. |
| 45 | Supply & Fixing in repair 110mm PVC (SWR) junction singal T equal or unuqual complete all as specified and directed. |
| 46 | Suplpy and fixing in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 47 | Supply & Fixing factory made Solid PVC Door Frame of Size 50mm x 47mm made out of 5mm plain colour PVC Sheet reinforced with MS Square tube in opening as per specification and frawing as per site complete all as specified and directed. |
| 48 | Supply & Fixing factory made 28 to 30 mm thick (Rajshri brand) factory madesolid PVC moulded Door shutter with 2,3 or6 raised psnel design with 2mm thick moulded PVC Sheet on the front face and 2mm plain colour PVC Sheet on back face, fixing in iron frame at site as per specification and drawing as per site complete all as specified and directed. |
| 49 | Hacking out old broken glass fromwooden/ steel window cleaning the surface and removing from the site, thenafter Supply & Fixing clear glass, 3mm thick ordinary quality, in any shape, not exceeding 0.50 sqm in each pane includingand glazing with oil putty/wooden beading as per site requiremnets complete all as specified and directed. |
| 50 | Supply & Fixing in Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed |
| 51 | Supply & Fixing in repair Helical door spring 300mm, ordinary rat tail rod pattern springs, including roller and roller plate fixed to iron chowkats with weilding complete all as specified and directed. |
| 52 | Supply & Fixing IInd class hard wood Glazed and skeleton shutters 35mm thick divided into square, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a) ; supplied and fitted to chowkats complete all as specified and directed. |
| 53 | Material & Labour for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of new surfaces complete all as specified and directed |
| 54 | Material & Labour for applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description over 10 cm in width or girth not otherwise described including prepration of new surfaces complete all as specified and directed |
| 55 | Supply & Fixing 300mm long Aluminium alloy, Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 56 | Supply & Fixing Aluminium, anodised, barrel tower bolts 150mm of extruded section and fixed complete all as specified and directed. |
| 57 | Supply & Fixing 150mm longAluminium handles, cast type anodised complete all as specified and directed. |
| 58 | Supply & Fixing stainless steel butt Hinges, 100mm size, medium weight, cold rolled mild steel complete all as specified and directed. |
| 59 | Materialand Labourin repair for Boxtypesteelwindowmade ofERW tube P- sectionof size 60 mmx25mm double rebated outer frame,comprises glazedskelton &gauzed shutterof ERW tube P-Section size 50mm x 20mmwith one/two Nos openable leaffor each shutter consisting of two Nos Sashbar of T-section 20 x 3 mmwelded to frame with one No verticle mullion of ERW box type T Section of size 60mm x 25mm and FI 2mm thick welded/screwed to frame for fixing of glass including fittings and fixture like as Handle, Tower Bolt, Stopper, Cleat, Pintal hinges, holdfast etc as given belowall as shown on drg No CEJZ/TD-1020/08Sh 1/3 to 3/3 dt 01 May 2008 complete all as specified and directed.(a) Hold fast 150mm long of 12mm x 3mm MS flat- 4 Nos per Window.(b) Handle of Z section 20mm x 25mm, 100mm long- 01 No per leaf.(c) MS tower bolt 150mm long - 02 Nos/leaf.(d) Z Section stopper 20mm x 25mm, 100mm long - 01 No per leaf.(e) Cleat 55mm long of hollow square 15mmx12mm - 02 Nos per leaf.(f)MS pintol hinges size 75mmx12mm - 2 Nos per leaf Note :- Sheet glass, wire mesh as required and painting shallbe measured and paid sperately. |
| 60 | Material and Labourin repair for Box type steel ventilator made of ERW tube P-section of size 60mmx25mmouterframe ( single rebated), comprisesglazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing ofsheet glassincluding fixture and fittingslike as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD1019/08 sheet 1/3 to 3/3 dt 01 May 2008 complete all as specified. NOTE:-Sheet glass, wire mesh as required and painting shall be measured and paid Separately. |
| 61 | Supply & Fixing pressed steel frames 1.25mm thick for door size of frame 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges including filling PCC type B-0 complete all as specified and directed. |
| 62 | Material & Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) in bed blocks for hold fast & similar work etc. incl necessary form work in repaircomplete all as specified and directed. |
| 63 | Taking down chowkhat with shuttering (without taking off shuttersfrom frame including grill & guard bars) sizeof shutter not exceeding 1.5 sqm each complete all as specified and directed. |
| 64 | All as per Srl item No 63 above but size of opening exceeding 1.5 Sqmtr but not exceeding 4 Sqm. |
| 65 | Taking down shutters of any description size of shutter exc 1 sqm but n.exc 2 sqm complete all as specified and directed. |
| 66 | S/F in repair15mm bore Concealed type stop cock cast copper alloy CP screweddown high pressure with crutch or butterfly handle complete all as specified and directed. |
| 67 | Supply & Fixing in repairs 100mm dia CP grating with or without hole type complete all specified and directed. |
| 68 | Supply & Fixing in repairs CP brass towel rail of 20mm dia and 600mm long complete all as specified and directed. |
| 69 | Supply & Fixing in repair 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down all as specified and directed. |
| 70 | Supply & Fixingin repair20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down all as specified and directed. |
| 71 | Material and Labour for repairing of RCC projections, chajjas, roofs, facia etc. by necessary preparations i.e. scrapping, cutting, chiseling, dusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1 : 2 : 4) using 12.5mm graded crushed stone aggregate minimum thickness 25mm and reinforced with 10mm TMT bars with or without facia and finished with cement sand mortar (1:3) using coarse sand in patches area n.exc 5 Sqm each and thickness of RCC member exc 50mm including applying two coats of Finishesto match with the existing surfaces in upto 12m height all as specified & directed. Note: - Cost of formwork and welded mesh, bldght upto 12 mtr, shall be deemed to be included in unit rate quoted by the Contractor. |
| 72 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, ceiling rose, etc.removing materials and making good disturbed surfaces of walls, floors, etc.including necessary cuttings, chases and making good in cement mortar 1:3 complete all as specified and directed. |
| 73 | Taking down carefully existing serviceable Ceiling fan/Wall mounted fan, ceiling cable,exhaust fan, ceilingend, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rodincluding clamps, hooks, hold fasteners etc. and connecting up, including making electric connection from ceiling rose or connector to fan complete all as directed |
| 74 | Material & Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through existing metallic/rigid PVC concealed conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as specified and directed for the following point :-NOTE : Switch, socket, fan regulator, lamp holder shall be measured and paid for separately. |
| 75 | (a)Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push. |
| 76 | (b) One socket outet point 5 amps on the same board. |
| 77 | (c) One socket outet point 5 amps on the independent board. |
| 78 | All as Ser item 74 here in before but with 2.5 sq mm wire and earth wire of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet. |
| 79 | Material & Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid new PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as specified and directed for the following point :-NOTE : Switch, socket, fan regulator, lamp holder shall be measured and paid for separately |
| 80 | (a) One light point/Bell/Fan point controlled by one switch. |
| 81 | (b)One 3 pin 5 Amps socket outlet on independent board. |
| 82 | (c)One 5 Amps outlet point on same board with other switches/sockets |
| 83 | All as per ser item No 79 here in above but pointwiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.(i)The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for nuetral and green for earth wire.(ii)Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates.(iii)Modular fittings/fixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item. |
| 84 | Supply & Fixing modular switch 1 way 6A, 240 volts, 1 module complete all as specified and directed |
| 85 | Supply & Fixing modular socket, 6A, 240 volts, 2/3 pin combined 2 module, flush type all as specified and directed |
| 86 | Supply & Fixing modular switch 1 way 16A, 240 volts, 1 module complete all as specified and directed |
| 87 | Supply & Fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type all as specified and directed |
| 88 | Supply & Fixing modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan all as directed |
| 89 | Supply & Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65 x 50 mm three terminal, 240 volts, AC single phase complete all as specified |
| 90 | Supply & Fixing lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed. |
| 91 | Supply & Fixing in repair LED lights fitting 1x 20W, 220V, AC, 6500K, decorative box type with driver, double sided connection,LED tube light connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose complete all as specified and directed. |
| 92 | Supply & Fixing in repair Air fresh fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 300 mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to exhaust fan and writing MES No. including cutting hole suitable for fixing exhaust fan and making good in cement mortar 1:3 as required complete all as specified and directed. NOTE : Old fan shall be deposited in store yard of MES. |
| 93 | Material & Labour in repair for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 8 way, 240 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, including dismantling of old UNSV one of any size/type from site and making good to disturbe surface wall complete all as specified and directed. NOTE: Necessary blank plates if required any to cover the blank MCB\"s place in DB and the rate shall be deemed to included in the quoted rates. |
| 94 | Supply & Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240 V, 10KA \"C\" curve fixed in the MCB DB complete with connection testing & commissioning complete all as directed |
| 95 | All as per ser item No. 94 above but for MCB SPN 40 to 63 Amps, 415 V grade. |
| 96 | Supply & Fixing in replacement, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cable drawn in and including non metalic PVC rigid conduit medium grade of suitable size with all standared fitting, on surface including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cable & conduit shall be measured as one unit one running metre complete all as specified and directed. |
| 97 | Material & Labour in repair for distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way , 3 phase , 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, including dismantling of old UNSV one of any type/size from site and making good to disturbe surface wall complete all as directed (1.) MCCB 100 Amps , 25 KA, TP 415 Volts complete all as specified and directed. |