Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling of single layer Mangalore pattern roofing tiles. Complete all as specified and directed |
| 2 | Material and labour for roughening of surfaces of old concrete slab by wire brushing, sweeping, cleaning and washing down to remove all loose dust etc. and brushing neat cement slurry @ 3.00 kg/Square Metre on roof surface, complete all as specified. |
| 3 | Material and labour for providing 10mm thick rendering over roof slab in Cement Mortar (1:4) mixed with water proofing compound @ 3% by weight of cement, finished even and smooth surface without using extra cement all as specified and directed (Note: Water proofing compound shall be measured and paid separately in relevant item) |
| 4 | Material and labour for Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown bitumen of any penetration applied hot @ 1.7 kg per sq. m. blinded with grit or pea size gravel @ 0.006 cu. m per sq. m, and lightly tampered (area of flashings, etc., shall be added to the roof area) |
| 5 | Material and labour forroof tiles Mangalore pattern, interlocking at side joints, laid dryall as specified and directed. |
| 6 | All as per item No. 5 above but except tiles |
| 7 | Material and labour forridgeor hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 all as specified and directed. |
| 8 | Dismantling/taking out existing hessian base felt or any otherexisting water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing the dismantled debris to a distanceexc 200m & n.exc 250m. all as specified and directed |
| 9 | Surface Preparation: Removing & clean the surface free of dirt, dust, laitance etc. using wire brush, grinding machine and water jet machine and allow the surface to dry. Opening the cracks, if any, in V/U shape using electrically operated cutting machine. Cleaning the surface thoroughly from dust and loose particles using wire brush and air blower and treat it with the crack filler |
| 10 | Material and labour for providing 15mm thick rendering over roof slab in Cement Mortar (1:4) mixed with water proofing compound @ 3% by weight of cement, finished even and smooth surface without using extra cement all as specified and directed (Note: Water proofing compound shall be measured and paid separately in relevant item) |
| 11 | Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric polyurethane based coating on terrace/Chajjas/Sunken portion of WC / Bathroom,PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 1.5MPa as per ASTM D 2370. The waterproofing membrane to be applied in 2coats @ 1.8 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm includingprimer coat of epoxy primer @150 g/m2 and protection with 50gsm Geo-textile over the waterproofing membrane. The finished cost to include making coving at Junction, Bore Packing, treatment as per specification. The work shall be executed as per standard technical specifications and as per the directions of the Engineer in charge of the work. |
| 12 | Taking down of cement plaster from wall or ceiling surfaces of any description etc including racking out joints, hacking for key, scrubbing down with water, etc |
| 13 | Material and labour for rendering 15 mm thick in cm (1:4) on fair faces of concrete surfaces and finished even and smooth without using extra cement and mixedwith water proofing compound @3% by weight of cement all as specified and directed(Note: Water proofing compound shall be measured and paid separately in relevant item) |
| 14 | Material and labour for rendering 10 mm thick in cm 1;3 on ceiling surfaces all as specified and directed |
| 15 | Material and labour for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc. by skilled labour complete all as directed. |
| 16 | Material and labour forsingle component polymer modified repair mortar with compressive strength minimum 38 MPA at 28 days (ASTM C 109:99) and tensile strength minimum 2.5 Mpa (ASTM C 307) up to 15mm in a single coat @ 34 kg per sqm for 15mm thickness internal plaster as per manufacturer instructionscomplete allas directed. |
| 17 | Material and labour for waterproof cement based putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:-Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 Ltrs per minutes with a maximum pressure 3300 PSIStep3) Allow 6-8 hrs time to dry the putty surface. |
| 18 | Material and labour forone coat of acrylic water based interior grade primer @ 0.8 ltr(undiluted)/10 sq Mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats. |
| 19 | Material and labour forapplying New Plaster wall and Ceiling Surface two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surfacecomplete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. |
| 20 | Material and labour forpreparation of old surface (Plastered or unflustered) of walls andapplyingOne coat of oil bound distemper including filling the holes, depression area with wall acre putty using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying material should be able to spray in hard to reach areas and penetration of distemper on the surfaceincluding scaffolding arrangement, trestles, ladders etc and cleaning of splashes fromfurniture and floors , doors/ windows up to two or three stories building complete all as specified and directed. |
| 21 | Material and labour for two coats of smooth interior acrylic emulsion with Texture finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 Ltrs(undiluted) /10 sq Mtrs diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint as per manufacturer instructions complete all as directed. |
| 22 | Material and labour forone coat of acrylic water based exterior grade primer @0.9 ltr(undiluted)/10 sq Mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coatsincluding necessary scaffolding and safety measures as requiredcomplete all as specified and directed. |
| 23 | Material and labour forpreparation of old surface (Plastered or unplastered) of walls and apply water proof cement based putty in holes and depression area over the plastered/old painted walland applyingOne coat water based premium acrylic smooth exterior emulsion of approved colourwith silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over acrylic water based grade primer @ 0.8 ltr(undiluted)/10 sq Mtrs diluted with water in 1:1 ratio with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. Make should be Apex shine of Asian Paint/Anti Dust of Burger/Mica Marble of Nerolac and paint to be prepared by machines only and can be of different shades as approvedincluding necessary scaffolding and safety measures as requiredcomplete all as specified and directed. |
| 24 | Material and labour forpreparation of New surface of wall and applingtwo coats water based premium acrylic smooth exterior emulsion of approved colourwith silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.Note for Item Nos. 15 to 24 above(a) The work pertaining to the above items shall be executed through an authorized applicator of the manufacturer of the materials proposed to be used by the contractor, such as paint, distemper, cement-based paint, putty, etc., and as approved by the Garrison Engineer.(b) The contractor shall produce the necessary applicator authorization certificate to the Garrison Engineer prior to commencement of the work. |
| 25 | Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 26 | Providing and applying plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified. |
| 27 | Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 28 | Material and labour for preparation of old polished wooden surface etc of any description over 10cm width or girth and applying one or more coats of French polishing complete all as specified and as directed by Engr-in-Charge. |
| 29 | Dismantling ceiling boards of any description including cover fillets, complete all as specified. |
| 30 | Supply and fix for Anodised Aluminium snap grid (minimum 15 microns anodisation) of size 605 x 605 mm with anodized aluminum angle of size 40mm x 25mm x 2mm thick weighing 0.36 Kg per running meter and anodized aluminum main and cross T of size 36.50 x 23.50 x 1.50 mm thick weighing 0.254 Kg per running meter and 23.50 x 23.50 x 1.50 mm thick weighing 0.202 Kg per running meter respectively for false ceilingcomplete all as specified and directed |
| 31 | Supply and fix hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long suitable for size of snap grid 605 x 605 mm complete all as specified and directed |
| 32 | Material and labourfor PVC insulation panels of 10mm thickness with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing in ceiling fixed with screws on snap grid all as per manufacturer instructions. (Note for Item No 28 to 30 : (a) Contractor will produced proper drawing of complete false ceiling including DOM Area and get approved by GE before execution (b) Necessary scaffolding and safety measures will be provided before execution of work) |
| 33 | Dismantling wall lining , any thickness, including cover fillets, complete all as specified |
| 34 | Solid PVC Wall paneling including of 5 mm thick single side prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame, complete all as specified. |
| 35 | 5 mm thick PVC sheet fillet of width 35 mm thick wall paneling inclusive of fixing of wall to make PVC frame, complete and as specified. |
| 36 | Taking down chowkats or frames with shutters (without taking off shutter from the frame ) exc 1.5 sqm but n.exc 4 sqm each including making good disturbed portion to match with adjoining surfaces and offering credit as per schedule of credit all as specified and directed. |
| 37 | Taking down chowkats or frames with shutters (without taking off shutter from the frame ) not exc 1.5 sqm each including making good disturbed portion to match with adjoining surfaces and offering credit as per schedule of credit all as specified and directed. |
| 38 | Material and labour forsecond class hard wood plain solid, straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue, pinned at jointsall as specified and directed. |
| 39 | Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (Face) & (Edge), minimum comp resave strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properly of being termite/borer proof, water /moisture proof and fire retardant and fixed in position with MS hold fast/lugs/ss dash fasteners of required dia and length complete as per direction of Engr-in-Charge (M.S. hold fast/lugs or SS dash fasteners shall be paid for separately).Note : For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 40 | All as per item No. 39 abovebut size of chowkats 50x100mm |
| 41 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 56-60(Suspension Grade), calcium carbonate and natural fibers (wood powder /rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water /moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sink S.S screws, all as per direction of Engr-in-Charge (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 42 | All as per item No. 41 above but of 35mm thick |
| 43 | Supply and fix 300 mm Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified |
| 44 | Supply and fix 125 mm brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified |
| 45 | Supply and fix 150 size Brass handles, cast type, polished bright complete all as specified |
| 46 | Supply and fix 100 mm Butt hinges, cast brass with mild steel hinge pin, bright polished and fixed, type B-11 |
| 47 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) up to 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steelscrews etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required sizeand of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wire meshshall be paid separately)Note: For uPVC frame and sash extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 48 | Supply and fix stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed. |
| 49 | Supply and fix in repairs stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed. |
| 50 | Material and labour 4mm thick sheet glass, ordinary quality and glazing with wooden beading not exc 0.5 Sqm in each pane all as specified and directed. |
| 51 | Material and labour 4mm thick figured glass, pin head type and glazing with wooden beading, not exc 0.5 Sqm in each pane all as specified and directed. |
| 52 | Material and labour for toughened glass thickness 10 mm as in hinged in railing, partitions automatic doors and similar work including cutting to shape, drilling holes required. all as specified and as directed. |
| 53 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge |
| 54 | Supply and fix in repair aluminium (Die cast ) body door closer hydraulically regulated designation No-3 universal type suitable for door shutters of 85 to 1000mm in width and of weight between 61 to 80 kg complete all as specified |
| 55 | Material and labour double action floor spring hydraulically regulated made up minimum 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty including taking down un-serviceable floor spring complete all as specified |
| 56 | Supply and fix in repairs Harrison curtain rails, mild, steel, chromium plated with brackets, stops,rollers etc. complete all as specified and directed. |
| 57 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) |
| 58 | Material and labour for 110 mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed |
| 59 | Material and labour for75 mm PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall , complete all as specified and directed |
| 60 | Supply and fix 75mm dia PVC (SWR) bend all as specified and directed |
| 61 | Material and labour for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cementcomplete all as specified |
| 62 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and removing all the rubbish as directed by Engineer-in-charge complete all as specified and directed. |
| 63 | Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exc 0.11 sqm but not exc 0.18 sqm in floor etc laid over and including 15mm thick screed bed in CM 1:4 set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete. |
| 64 | Material and labour for glazedceramic coloued tiles in vertical surfaces 300x450x7mm thick over and including 10mm thick cement plaster in CM 1:3 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete. |
| 65 | Material and labour for Light shade Vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tileexceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc set and jointed in neat cement slurry and pointedin white or coloured cement to match etclaid over and including 15mm thick screed bed in CM 1:4and set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 66 | Material and labour for Light shade Vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tileexceeding 0.42 sqm but not exceeding 1.00 sqm as in skirting set and jointed in neat cement slurry and pointed in colour cement over 10 mm thick rendering in cement mortar 1:3 including taking down old wall dado/finishes of any description, complete all as specified and directed. |
| 67 | Demolition of stone slabs and tiles of any description or thickness in floor, aprons etc laid bedded and pointed in any mortar all as specified and directed |
| 68 | Material and labour for 20 mm thick Granite (of any type) work black colour (table rubbed and polished) in steps, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 20mm thick cement mortar (1:4)all as specified and directed.(Rate including hole of cooking platform) |
| 69 | Material and labour for machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick screed bed in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing polishing etc complete |
| 70 | Material and labour for machine cut kota stone slab as in skirting 20-25mm thick over and including 10 mm thick rendering in CM (1:3) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing polishing etc complete |
| 71 | Supply and fix in repairs bib taps, cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe 15mm bore all as specified and as directed. |
| 72 | Supply and fix in repairs pillar taps, cast copper alloy fancy type, chromium plated with capstan heads screwed down high pressure with long screwedshanks and fly nuts, screwed for iron pipe of 15mm bore all as specified and as directed. |
| 73 | Taking up or down steel tubing and connections of 25mm bore including cleaningor removal to store all as specified and directed. |
| 74 | Taking up or down GI tubing and connections 32mm bore including cleaningor removal to store all as specified and directed. |
| 75 | Supply and fix 25 mm dia UPVC pipes of pressure rating 10 Kgf/cm2fixed complete to walls, ceiling or in floors etc |
| 76 | Supply and fix 32 mm dia UPVC pipes of pressure rating 10 Kgf/cm2fixed complete to walls, ceiling or in floors etc |
| 77 | Supply and fix in repairs vitreous china wash down water closer (pedestal pattern)white, including fixing bolts and necessary connection with existing pipes etc complete all as specified and directed. Note: Quoted rate shall excludes the cost of flush pipe, cistern & seat cover and the same shall be paid separately under respective item. |
| 78 | Supply and fix in repair for seat cover for pedestal pan with plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device completed all as specified and directed. |
| 79 | Supply and fix in repairs 10 ltr capacity PVC valveless synphonic action type flushing cistern high or low level (exclusive of brackets) white with inlet ball valve, float and handle including brackets complete all as specified and directed. |
| 80 | Supply and fix in repairs for providing 15mm dia PVC connection of length 450mm long complete all as specified and directed. |
| 81 | Supply and fix repairsflush pipe PVC 32mm dia for low level flushing cistern to pedestal pan, including all joints, cones, India (nozzles of W.C pans) all as specified and directed. |
| 82 | Supply and fix in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and directed. |
| 83 | Supply and fix in repairs two way bib cock with two level and wall flange chromium plated brass of approved make, screwed for iron pipe 15mm bore complete all as specified and directed. |
| 84 | Supply and fix oval shaped under counter wash hand basin vitreous china size 590x420 mm including brackets waste brass chromium plated with long screwed shanks and fly nuts 32mm size complete all as specified and directed |
| 85 | Supply and fix in repairs fancy type pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and 15mm bore of pipe. |
| 86 | Supply and fix in repairs for vitreous china urinals, half stall (back or corner wall type ) complete including providing and fixing plugs bedding urinal against wall in cement mortar in 1:2 securing urinals to plug with and including 60mm long brass screw pointing around urinal back in cement etc complete all s specified and directed. |
| 87 | Supply and fix self closing taps, cast copper alloy, chromium plated, screwed for iron pipe of 15mm dia and fixed for urinals in repairs complete all as specified. |
| 88 | Supply and fix in repairs 32mm sizewaste fitting brass, chromium plated foe glazed ware sinks,basins,etc with long screwed shaks and fly nuts, flange end bedded in red lead cement and other end fixed all as specified and directed. |
| 89 | Supply and fix in repairs 32mm dia PVC waste pipe for WHB and urinals fixed in repairs complete all as specified and directed. |
| 90 | Material and labour 600x450mm beveled edge looking mirror 5mm thick selected quality glass mounted on 6mm thick AC building board fixed to wall by wooden plug with chromium plated brass screw and cup washer fixed as in repair complete all as specified and directed. |
| 91 | Supply and fix in repairs toilet paper holder with flat recessed type stainless steel etc complete all as specified and directed. |
| 92 | Supply and fix brass CP towel rail,20mm dia, Dtype, 60cm long between flanges fixed in repairs complete all as specified. |
| 93 | Supply and fix in repairs brass chromium plated shower rose with or without swivel joints, of 125mm size fancy type suitable for 14mm bore GI pipe all as specified and as directed. |
| 94 | Supply and fix in repairs brass chromium plated mixer for mixing hot & cold water screwed down for 15mm dia iron pipe of complete all as specified and directed. |
| 95 | Supply and fix in repairs stop valves/ angle valve, cast copper alloy fancy type chromium plated with long shank and cup (concealed type), screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore all as specified and directed |
| 96 | Supply and fix in repairs stop valves/ angle valve, cast copper alloy fancy type chromium plated with long shank and cup (concealed type), screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 20mm bore all as specified and directed |
| 97 | Dismantling of PVC/ RCC water storage tank of capacity exceeding 500 litre but not exceeding 1000 litre, including removal of rubbish outside MoD land, complete all as specified. |
| 98 | Supply and fix Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position including tank cover, complete all as specified. |
| 99 | Supply and fix in repair25 mm dia Ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 455 gms), screwed & suitable for iron pipe 25 mm bore, complete all as specified. |
| 100 | Material and labour. for Chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure & cleaning and disposal of debris outside (Hard concrete should not be removed by force.) |
| 101 | Clean existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and providing, applying two coats of alkaline rust converting primer confirming to ASTMB-117, on the existing rebars and allowing it to react with rust for 6 hrs. and form a corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 1 hour between the coats. |
| 102 | Material and labour for providing and fixing additional steel bar or stirrups of diameter in various structural elements like columns, beams and foundations including drilling, bending and fixing the bars with epoxy putty etc. |
| 103 | Providing and application of hi-tech concrete penetrating, water based, organic, Bi-polar, calcium nitrite free, migratory corrosion inhibitor on concrete surface having Ph 9.5 which migrates to a virtual extent of 100 mm inside concrete through pores, to inhibit the corrosion process on embedded steel at both anodic and catholic ends by depassivating the Electro-chemical reaction in that region thereby protecting rebar on all sides. |
| 104 | Providing and application full and unbroken coating of anticorrosive protective zinc rich epoxy coating on expose reinforcement in two coats with time interval of minimum 1 hours between each coat including mixing of both components by weight as per mfg. specifications, brush application, curing to form a anticorrosive protective coating with high mechanical strength to cementations repair works, etc. |
| 105 | Mixing and applying SBR latex modified cementitious bond coat using cement 2.2 kg per square meter on prepared concrete surfaces of parent material complete all as specified. |
| 106 | Material and labour for providing and applying for polymer bonding agent followed by flexible polymer-based putty and shall be filled in properly cut \"V\" groove in cracks of structural elements, finish with spatula etc. |
| 107 | Mixing and applying SBR latex modified cement mortar 30 mm thick in cement sand mortar in proportions of 1:3 (1 cement and quartz aggregate) with polymer admixed in proportions as approved, including troweling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as per site in charge guidelines. |
| 108 | Rebuilding the section of damaged RCC elements to required size avg thickness 50 mm by providing and casting with micro concrete of grade M-40 and above including providing and fixing of watertight shuttering of minimum 12 mm thick. with supporting framework, all lead lift, mixing, placing, de shuttering, leveling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of expertise in command, etc. complete. |
| 109 | Drilling Holes of 10mm dia, up to 40mm deep holes in structural members at the intervals of 300 to 500mm in staggered manner or along the crack as directed by the Engineer-in- charge in RC structural element including Cleaning of the holes by air blower and inserting 8mm dia. Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix it inside the holes by applying thyrotrophic epoxy putty to ensure complete sealing and allow to cure the system for min. 8hrs before grouting including removing nozzle projections, excess putty if any over concrete element grinding, leveling and finishing the external surface, after completion of the work, etc complete. |
| 110 | Supply only approved SBR Latex polymer, for application on wall to prevent dampness and seepage. |
| 111 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 112 | Material and labour for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw inPVC conduit including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light/fan/bell point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 113 | All as per item No 112 above but for 5 pin switch socket outlet 5 Amp on same board with other switches, complete all as specified. |
| 114 | All as per item No 112 above but for 5 pin switch socket outlet 5 Amp on independent board complete all as specified. |
| 115 | Material and labour for point wiring with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC conduit including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for 3 pin switch socket outlet 15/20 Amp on independent board and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 116 | Material and labour for point wiring with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC conduit including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for AC Socket on independent board and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 117 | Material and labour for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & including PVC surface casing \"N\" capping double lock type to be fixed with the help of rawal plugs & screws including necessary fitting Supply and fixture and to be terminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches & sockets with 3 mm thick plastic laminated sheet cover of adequate size for 5 pin switch socket outlet 5 Amp on independent board and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified.Polycab/Havells/Bajaj. |
| 118 | Material and labour for point wiring with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & including PVC surface casing \"N\" capping double lock type to be fixed with the help of rawal plugs & screws including necessary fitting Supply and fixture and to be terminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches & sockets with 3 mm thick plastic laminated sheet cover of adequate size for 3/5 pin switch socket outlet 15/16 Amp on independent board and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified. . |
| 119 | Supply and fix modular switch 1 way , 10AX, 1 module complete all as specified and directed by Engr-in-Charge. Cat part No AHCSXXW101 of make Havells or equivalent model in makes specified in Appx-B |
| 120 | Supply and fix modular socket outlet 6 Amp, 2/3 Pin combined, 2 module complete all as specified and directed. Cat part No AHLKPXW063 of make Havells or equivalent model in makes specified in Appx-B |
| 121 | Supply and fix modular switch 1 way , 16 Amps, 1 module complete all as specified and directed by Engr-in-Charge.Cat part No AHCSXXW161 of make Havells or equivalent model in makes specified in Appx-B |
| 122 | Supply and fix modular socket outlet 6/16 Amp, 2/3 Pin combined, 2 module complete all as specified and directed. Cat part No AHLKCXW163 of make Havells or equivalent model in makes specified in Appx-B |
| 123 | Supply and fix modular bell push 6 Amp 1 module complete all as specified and directed by Engr-in-Charge.Cat part No AHCSBIW100 of make Havells or equivalent model in makes specified in Appx-B |
| 124 | Supply and fix bell multi music type complete all as specified and directed by Engr-in-Charge |
| 125 | Supply and fix in repair Lamp holder with rating 250V and 10 Amp, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed. |
| 126 | Supply and fix modular fan step regulator 120 W, 2 module complete all specified and directed. cat part No AHARFHW005 of make Havellsor equivalent model in makes specified in Appx-B |
| 127 | Supply and fix ceiling rose surface type bakelite 50x65 mm two to three terminals all as specified. |
| 128 | Supply and fix modular Box sheet metal with socket 3 pin, suitable for 25 Amps flush type universal including 25 Amp \"C\" series MCB protected. (For AC socket) complete all as specified and directed. |
| 129 | Supply & fix in repairLED tube light along with fixture, Wattage22 W,CCT-WW, 6500 K, CRI Below 80, Power factor 0.9, TDH More than 20%, Surge Protection 4 kV,4 feet long including provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed by Engr-in-charge. Cat part No -BTI-WHT-LGLZU1X022XW of make Jaguar or equivalent model in makes specified in Appx-B |
| 130 | Supply and fix in repair LED tube light along with fixture, Wattage5 W,CCT 6500 K, CRI Below 80, Power factor 0.9, TDH More than 20%, Surge Protection 4 kV,1 feet long including provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed by Engr-in-charge. Cat part No -BCLSB 05 WHof Bajaj or equivalent model in makes specified in Appx-B |
| 131 | W LED, 3000 K, Decorative wall light, Brass, rust free fixture with white glass diffuser suitable for 9 W LEDfilament lamp E27 base cap, CCT-WW, complete all as specified and directed by Engr-in-Charge.Cat part No OWA-WHT-15001 of make Jaguar or equivalent model in makes specified in Appx-B |
| 132 | Supply and fix LED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP54 complete all as specified and directed by Engr-in-Charge. Cat part No -ILO-BLK-LBLK03Z010XW , CCT-WW of make Jaguar or equivalent model in makes specified in Appx-B |
| 133 | Supply and fix LED down light 18 W , square surface mounted, opaque diffuser including all accessories, complete all as specified and directed. Cat part No IDL-WHT-LNRO02S018SW , CCT-WW, Make : Jaguar or equivalent model in makes specified in Appx-B |
| 134 | Supply and fix LED down light 6 W, circular surface mounted, opaque diffuser including all accessories, complete all as specified and directed. Cat part No IDL-WHT-LNRO02R006SW , CCT-WW, Make : Jaguar or equivalent model in makes specified in Appx-B |
| 135 | Supply and fix Ultima ultra slim LED light fitting 33 W, 1\" x 4\"LED luminaries recess mounting, CRCA housing white powder coated with polymer diffuser including provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed by Engr-in-Charge. Cat part No-IPN-WHT-LULU4SL33CLW, CCT-WW of make : Jaguar or equivalent model in makes specified in Appx-B |
| 136 | Taking down ceiling/Exhaust fan any size and refixing at the same place or other location after cleaning, greasing, oiling and servicing complete all as specified and directed by Engr-in-Charge. |
| 137 | Supply and fix MCB TPN,40 to 100Amps, 415 V, 4 Pole, 10 KA, \"C\" Series complete all as specified and directed. |
| 138 | Supply and fix MCB SPN, 32 Amp, 240 V, 10 KA complete all as specified. |
| 139 | Supply and fix MCB TP, 25Amps, 415 V, 3 Pole, 10 KA, \"C\" Series complete all as specified and directed. |
| 140 | Supply and fix MCCB250 Amp, 415 V, 36 KA complete all as specified. |
| 141 | Supply and fix MCB SP, 5-32 Amp, 240 V, 10 KA complete all as specified. |
| 142 | Supply and fix sheet metal enclosure powder coated DB for fixing of MCBs, SPN 8 ways double door, IP-42 protection with 200 Amp rated bus bar, 240 Volts including taking out of old MCB DB of any type/size and removing from site to MES store for reuse if serviceable or for credit complete all as specified and directed. |
| 143 | Material and labour for sub main wiring with two single core PVC insulated, FRLS unsheathed multi stranded copper conductor cable confirming to IS 694-1990 of size 4 Sqmm (nominal area) in existing conduit and continuous PVC insulated single core copper conductor stranded unsheathed 2.5 sqmm as earth wire complete all as specified and as directed(Two single core cable and one No earth wire shall be measured together as one length) and making good the disturbed surfaces. |
| 144 | Material and labour for sub main wiring with two single core PVC insulated, FRLS unsheathed multi stranded copper conductor cable confirming to IS 694-1990 of size 6 Sqmm (nominal area) in existing conduit and continuous PVC insulated single core copper conductor stranded unsheathed 4 sqmm as earth wire complete all as specified and as directed(Two single core cable and one No earth wire shall be measuredtogether as one length) and making good the disturbed surfaces. |
| 145 | Material and labour for sub main wiring with two single core PVC insulated, FRLS unsheathed multi stranded copper conductor cable confirming to IS 694-1990 of size 10 Sqmm (nominal area) in existing conduit and continuous PVC insulated single core copper conductor stranded unsheathed 6 sqmm as earth wire complete all as specified and as directed(Two single core cable and one No earth wire shall be measuredtogether as one length) and making good the disturbed surfaces. |
| 146 | Material and labour for earthing complete with galvanized cast iron earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized earth lead 4 mm dia by means of bolts, nuts washers and check nutsof steel/GI duly protected with 15mm bore light grade pipe up to main board, 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, char coaldust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for PCC cover, funnel withwire mesh complete and all as specified.Note :-The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15mm bore, RCC cover slabs 50mm thick with8mm dia CTD bars @ 140mm c/c both ways etc complete. |
| 147 | Removing and re-fixing only 9 W LED, 3000 K, decorative, wall mounted, die-cast Al fixture with ivory powder coating complete all as specified and directed by Engr-in-Charge. |
| 148 | Removing and re-fixingonly LED down light 6 W, circular recess mounted, opaque diffuser including all accessories, complete all as specified and directed. |
| 149 | Removing and re-fixingonly LED tube light fitting 1x18/20 W, 6500 K including provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed by Engr-in-Charge. |
| 150 | Supply and fix tube light fitting 30 W, 2\" x 2\"LED luminaries recess mounting, CRCA housing white powder coated with polymer diffuser including provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed by Engr-in-Charge. |
| 151 | Supply and LayingLT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches /walls/ poles/ passing through pipes with multistranded aluminium conductor including lugs / thimble /ferules connection, testing and commissioningcomplete of size 3.5 core 240 sqmm. Note: [i]Earth work, excavation, GI tubing/DWC pipe for protectionetc shall be measured separately under relevant items of this schedule work. |
| 152 | Excavation in trenchesnot exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and forlaying of LT under ground cables/GI pipesgetting out as in soft /loose soil complete all as specified and directed. |
| 153 | Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soilcomplete all as specified and directed. |
| 154 | Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 155 | Supply and fix DWC high density polyethylene pipes having 110/95 mm dia with all fittings/coupler/connecting accessoriesconfirming to IS:16098 Part-02 and IS: 16025 Part -24 for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed |
| 156 | Material and Labour for GI tubing \"Light\" grade100 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed. |
| 157 | Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed. |
| 158 | Supply, installation, testing and commissioning ofLT panel Indoor type in replacement of old unserviseblae panel made out of 2mm thick CRCA sheet and mounted on Floor, weather/dust proof, factory made, IP-54 with Double door openable shutters on both sides front and rear having locking arrangements, totally enclosed weather proof, powder coated over a coat of primer suitable for 440V, 3 Phase, 4 wire 50 C/s, aluminium bus bar of suitable size and capacity, AC supply, electrically connected as per norms and fitted including connecting up all out going MCCB/MCB/timer switch for street lights, 3phase meter with suitable sizestranded copper cable and fixing on floor,comprising of the following accessories complete allas specified and directed by Engr in charge :Note: (a)The LT panel should be procured through CPRI approved manufacturer(b) The proper gland pacing for the cable entries to be provided.(c) The design of the LT panel to be taken prior approval from GE before procurement |
| 159 | (a) Aluminium bus bar with proper colour code -04 Nos. 1000 Amp Cap duly fixed on suitable size insulator, nuts bolts etc complete as per OEM recommendations.(b) Indicator Lamp-01 Set (Set of three)(c) Incomer MCCB, 415 Volt, 4 pole, 630 Amps, 45 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100%- 01 No (d) Outgoing MCCB, 415 Volt, 4 pole, 125 Amps, 38 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100%- 09 Nos (01 No Spare part)(g) OutgoingMCB TPN, 415 Volt, 4 pole, 63 Amps, 10 KArupturing capacity - 02 Nos(h) Digital Voltmeter 0-500 Voltand Digital Ammeter0-800 Amp with selector switches (i) Complete wiring with suitable size copper cable, thimble etc. |
| 160 | Supply, installation, testing and commissioning ofLT panel Indoor type in replacement of old unserviseblae panel made out of 2 mm thick CRCA sheet and mounted on Floor, weather/dust proof, factory made, IP-54 with Double door openable shutters on both sides front and rear having locking arrangements, totally enclosed weather proof, powder coated over a coat of primer suitable for 440V, 3 Phase, 4 wire 50 C/s, aluminium bus bar of suitable size and capacity, AC supply, electrically connected as per norms and fitted including connecting up all out going MCCB/MCB with suitable size of Aluminium bus bar or with stranded copper cable and fixing on floor,comprising of the following accessories complete allas specified and directed by Engr in charge :Note: (a)The LT panel should be procured through CPRI approved manufacturer(b) The proper gland pacing for the cable entries to be provided.(c) The design of the LT panel to be taken prior approval from GE before procurement |
| 161 | (a) Aluminium bus bar with proper colour code -04 Nos. 1200 Amp Cap duly fixed on suitable size insulator, nuts bolts etc complete as per OEM recommendations.(b) Indicator Lamp-01 Set (Set of three)(c) Incomer ACB, 415 Volt, 4 pole, 800 Amps, 50/65 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100%- 01 No(d) Outgoing MCCB, 415 Volt, 4 pole, 250 Amps, 38 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100%- 07 Nos (01 No Spare part) (g) OutgoingMCB TPN, 415 Volt, 4 pole, 63 Amps, 10 KArupturing capacity - 14 Nos(h) Digital Voltmeter 0-500 Voltand Digital Ammeter0-800 Amp with selector switches (i) Complete wiring with suitable size copper cable, thimble etc. |
| 162 | Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable lengthplaced on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth platewith fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 163 | Material and labour for earthing GI strip of size 32x6mm with fixing materials like clamp, welding, porcelain type fittings complete all as site requirement. |
| 164 | Supply and fix in repair cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly riveted withangle of size 50x50x4mm and 60cm long including PCC 1:2:4 B1 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified and directed by Engr-in-Charge. |
| 165 | Material and labour PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) for coping etc as mass concrete complete and all as specified and directed by Engr-in-Charge. |
| 166 | Supply and laying rubber mat of 1 meter x 2 meter x 10 mm all as specified and directed by Engr-in-Charge |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail