| 1 | Surface excavationn.exc 30cm deep and averging 15 Cm and getting out in hard/dence soil completeall as specified and directed. |
| 2 | Surface dressing n.exc. 15 cm deep in hard/dense soil including cutting of bushes, sapling etc. complete. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m in hard/ dense soil, as directed by Engineer-incharge |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m in in soft/disintegrated rocks, as directed by Engineer-incharge. |
| 5 | Excavation in post holes (or similar holes) each n exc 0.50cum, getting out, returning, filling, in andramming earthor broken rubble mixed with earth arouond in layers n.exc. 25cm, watering and removing surplus soil to distance n exc 50 m and making good surface in hard/dense soil. |
| 6 | Excavation in post holes (or similar holes) each n exc 0.50cum, getting out, returning, filling, in andramming earthor broken rubble mixed with earth arouond in layers n.exc. 25cm, watering and removing surplus soil to distance n exc 50 m and making good surface in Soft/loose soil. |
| 7 | Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 8 | Removing excavated material as in soft disintegrated rocks exc 50m and n.exc 250m, and depositing where directed at a level n.exc 1.5m above the starting point completeall as specified and directed. |
| 9 | Removing excavated material as rocks exc. 1.5km and n.exc 5 km depositing where directed . |
| 10 | Returning, filling-in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 11 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering |
| 12 | M&L for Hard core, using broken stone or boulders of guage n.exc. 63mm, deposited, spread and levelled in layeres n.exc. 15 cm thick, watered and rammed to a true surface, as in below sub base, plinth protection and ramp, complete all as directed by Engr-in- Charge. |
| 13 | M&L PCC 100 mm thick, type C-2, 1:3:6 (40mm graded aggregate) as in sub-base, complete all as directed. |
| 14 | M&L 75mm thick PCC, type C-2, 1:3:6 (20mm graded aggregate) as in plinth protection, surface finished even and smooth without using extra cement complete all as directed. |
| 15 | M&L for RCC type M-30 (20 mm graded aggregate) as in foundations, plinth beams, bases forcolumn etc. complete all as directed by Engr-in-Charge. |
| 16 | M&L for RCC type M-30 (20 mm graded aggregate) as in column etc. complete all as directed by Engr-in-Charge. |
| 17 | M&L for form work to sides of columns, square, rectangular, complete all as directed by Engr-in-Charge. |
| 18 | M&L for form work to rough finished surface to edges of concrete flat, break in floor.cills,railings etc.& similar works, exc 10 but n exc 20cm wide complete all as specified and directed. |
| 19 | M&L for form work to sides and soffits fo roof beams, lintel beams etc. including supports, overhangs, etc. also splays between floors and beams, etc. complete all as directed by Engr-in-Charge. |
| 20 | Formwork to soffit of suspended slabs such as roof slabs floor slabs, landings and similar works not exc 200 mm thick (Horizontal or sloping).complete all as directed by Engg-in charge. |
| 21 | M&L for RCC type M-30 (20 mm graded aggregate) as in lintel beams, roof beams etc. complete all as specified and directed . |
| 22 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 23 | M&L for RCC type M-30 (20 mm graded aggregate) as in roof slab supported on walls, beams and columns in roofs etc. complete all as specified and directed. |
| 24 | M&L PCC 1:4:8 type D-2, (using 40mm graded crushed stone aggregates) in foundation/filling mass concretecomplete all as specified and directed. |
| 25 | M &L Forming 20mm thick expansion joints filled with preformed bitumenous filler and top 30mm primed and sealed with sealing compound, grade \"B\", 200 mm thickness complete all as specified and directed. |
| 26 | M&L Forming construction (Dummy) joint for 65mm deep x 10mm wide, filled with sealing compound, Grade-\"B\", complete all as specified and directed. |
| 27 | M&L Squared rubble walling with Porbandar stone masonary in CM 1:6 brought to courses, complete all as specified & directed by Engr-in-charge. |
| 28 | M&L 15 mm thick External plastering in CM 1:6finished even & smooth without using extra cement and applying sagol finish complete. |
| 29 | M&L 10 mm thick Internal plastering in CM 1:6finished even & smooth without using extra cement completeall as directed by Engr-in-Charge.. |
| 30 | M&L Internal Plastering 5 mm thk to Ceiling in CM 1:3 completeall as directed by Engr-in-Charge. |
| 31 | M & L preparing surface of newly plasteredwalls and applying two coats of oil bond distemper over chalk whitening preparatory to distempering. |
| 32 | M & L for preparation of newly plastered surfaces of Ceiling and applying three coats of white wash |
| 33 | M & L for applying two coats of colour washing over one coat of white washing including preparation of new plastered surfaces complete. |
| 34 | S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W(Gde- E- 250) quality-A- complete. |
| 35 | S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 36 | S & F Plain, galvanised, mild steel sheeting 0.63 mm thick , in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 |
| 37 | M&L for 75 mm thick (Compacted thickness) WBM of granite, trap or basalt with coarse aggregate of gradingg 2 (63 to 40mm size), spread, rolled and consolidated to gradient and camber required all as specified. |
| 38 | M&L for Cement concrete work in pavement / hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 200 mm complete all as specified and as directed. |
| 39 | M&L Finishing surfaces of concrete roads, pavements, by brooming. Complete all as specified and directed. |
| 40 | M&L for Polythene film, black, 50micron laid in floors complete all as specified and directed. |
| 41 | M&L for forming 20mm thick thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, for thickness of concrete slab 200mm complete all as specified and as shown on drawing. |
| 42 | M&L forming construction Joints (grade \"B\") 30mm deep and10mm wide, with sealing compound complete all as specified and directed by Engr-in-Charge |
| 43 | S&F Long solar Delinator made out of powder coated Medium grade MS pipe 48 mm dia, 1.00 Mtr Heigh (0.70 above ground level and 0.30 below ground level)reflecting / blinking portion coverd with welded mesh of 3 mm wire dia and 50 mm x 50 mm mesh includingnecessary painting,excavation and embedding in PCC (1:2:4) block of size 250 mm x 250 mm x 350 mmcomplete all as specified and directed. Make: 3M, OSCAR orits equivalent as approved by GE |
| 44 | S&F Mild steel CRS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed . |
| 45 | S&F Mild steel CRS TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified. |
| 46 | S&F Mild steel CRS TMT bars 8 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed . |
| 47 | M & L rendering 20 mm thick in two layers (15+5) ,on fair faces of stone masonry surfaces or concrete surfaces in cement mortar 1:4 finished even & smooth with out using extra cement completeall as specified and directed. |
| 48 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing),and rubbish off the premisess complete all as specified and as directed |
| 49 | M&L Machine cut kota stone slab flooring/skirting 20-25mm thick over 20mm thick cement screed base in CM(1:4)laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 50 | M&L coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match |
| 51 | M&L 10 mm thick rendering in CM (1:4) on brick or concrete surfaces for fixing of tiles in wall etc complete all as specified and directed by Engineer - in - Charge. |
| 52 | S&F forposts and struts (angle) including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 53 | S&F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates |
| 54 | M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete (Fe 410 -W (Gde- E- 250) quality- A) complete. |
| 55 | M & L for two coats of synthetic enamel paint over a priming coat of red oxide after preparation of new surfaces of any description, over 10cm in width or girth,not otherwise described all as specified & directed. |
| 56 | Dismantling of staineless steel work of any description any section embedded in concrete, masonry etc including taking out embedded portion and making good disturbed ground. |
| 57 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary Accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 58 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 59 | Material and Labour for 15mm thick rendering onfair faces of brick work or concrete surfacesin cement mortar 1:4 finished even and smoothwith out using extra cement complete all as specified and as directed. |
| 60 | Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified |
| 61 | M& L for preparation of old plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces to prepare the surface even and smooth of required shade and colour as per manufacturer\"s specification complete all as specified and directed. |
| 62 | Material and labour for preparation of old distempered wall surfaces by washing, rubbing down and stopping the surfaces and applying one coat of oil bound distemper to interior walls complete and filling the imperfaction surfaces even such as holes, dirt, fine cracks are to be filled with 2-3 layer wall care putty (whereverrequired as directed by Engr-in-charge) all as specified and as directed. |
| 63 | Material and labour for preparation of old surfaces of ceiling including cornicess plaster etc for lime wash (white washing) andapplying one coat of white wash on ceiling complete all as specified and as directed. |
| 64 | Demolition of concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) complete including removing debries ouside MD land all as specified and directed. |
| 65 | M & L for 50mm thick Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in plinth protection,Floor topping etc , surfaces finished of concrete flooring with brooming complete all as spd and directed by Engr-in-Charge |
| 66 | Taking down old roof treatment of any description including plaster, cement concrete etc. and removing old material outside MD land exc 1Km and not exceeding 5 Km completely all as specified and directed by Engineer - in - Charge. |
| 67 | M&L for 10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane,add WPC @3% of cement weight(WPC paid separately),finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Polymeric membrane will be measured and paid separately) |
| 68 | Supply only integral waterproofing compound |
| 69 | M&L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment/ specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 4 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 160 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. (Note:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction.(ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instruction. (c ) Applying two coats of reflective Bituminous aluminium paint on top of APP membrane. |
| 70 | S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 71 | S&F plain/coloured FRP sheeting 2-3mm thick, roofs, windows, duct covering or at any other location by coach screw and washer, nut & bolt, staple pins or any other sutiable means all asspecified and decided by engg-in-charge. |
| 72 | M&L for painting of existing galvalume pre-painted sheets with polyurethe Industrial paint of approved shade with two coats by spray/brush as per manufacturer Instructions and as directed by Engr-in-Charge complete in all aspects including material labours T&P,scaffolding etc. The work to be carried out on roof top & sides of existing buiding having height upto 15m. |
| 73 | M& L for point wiring with PVC insulated unsheathed stranded copper conductor cable FRLSH of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width/in concealed conduit non metallic , rigid PVC conduit of adequated size with all fittings and conduit accessories including suiitable size modular metal flush box and modular white cover plate with frame for housing the switches,socket outlets ,including all necessary wall cutting and making good disturbed surface allas directed and specified .Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. |
| 74 | One light point controlled by one, one way switch |
| 75 | One ceiling /exhaust fan point controlled by one switch and regulator |
| 76 | All as per same in item No 76.00 but wire 2.5 sqmmOne 3 pin 5 amp socket out point on the independent board |
| 77 | All as per same in item No 76.00 but wire 2.5 sqmmOne3 pin 5 amps socket out let point on same board with other switches. |
| 78 | All as per same in item No 76.00 above but for one socket outlet 15 amp on independent boardwith4.0Sq.mmcableand4.0Sq.mm.earthwire. |
| 79 | S & F Modular switch 1 way 6A, 1 module all as specified and directed by EIC. |
| 80 | S & F Ceilingrose, surface bakelite 65x50 mm three terminal |
| 81 | S & Fmodular socket, Socket, 6A - 2/3 pin combined 2 module all as specified and directed by EIC. |
| 82 | S & F Modular switch 1 way 16A, 1 module all as specified and directed by EIC. |
| 83 | S & F modular socket 16A - 2/3 pin combined 2 module, all as specified and directed by EIC. |
| 84 | S & FModularfan regulator 120 Watt, 2- module , AC 240 Volts complete. |
| 85 | S & F LED tube light fittings 4 feet 1x20 Watt ,220V, Indoor decorative LED Engineering Plastic batten with opal diffuser, IP 20 and with System Efficacy of 100lm/W ,holder including LED Tube light connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rosecomplete all as directed by Engr-In-Charge. |
| 86 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and as directed. |
| 87 | S & F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link,IP-43-IK09 protection grade , 415Volts TPN with 6 way Double door |
| 88 | S & F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link,IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door |
| 89 | S & F MCB TPN 415 Volts, \"C\" series, breaking capacity 10 KA of rating 40to 63Amps |
| 90 | S & F MCB TP 415 Volts, \"C\" series, breaking capacity 10 KA of rating 25to 63 Amps |
| 91 | S & F MCB SP 240 Volts \"C\" series, breaking capacity 10 KA of rating 6-32 Amps |
| 92 | S& F XLPE insulated armoured and pvc sheated heavy duty electric cable , aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendmentlaid in tranches passing through pipes /ducts including testing complete for following sizenote- rate is inclusive of cable gland & cable lugs Make- Havells/FINOLEX/CCI/KEI/POLYCAB |
| 93 | 4 core 10 Sqmm cross sectional area |
| 94 | 4 core 16 Sqmm cross sectional area |
| 95 | Supply and laying of Double Walled Corrugated(DWC) HDPE pipe of size 40/32 mm outer/inner dia conforming to IS 16205 Part -24including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge. Make:- ASTRAL TELEREX / eqivalent as approved by GE. |
| 96 | S & FLED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as directed by Engr-In-Charge. |