Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all asdirected. |
| 2 | Excavation in post holes in soft/loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface. complete as as directed. |
| 3 | Excavation in trenches n exc 1.5 m widen exc 1.5 m deep in soft/ loose soil for foundation etcor for shaft, wells, manholes ,laying of cable etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out. complete all asdirected. |
| 4 | M&L for hard core of broken bricks of gauge exe 63 mm and nexc 100mm deposited spread and leveled in layers not exe 15cm thick watered and rammed to a true surface complete all as directed. |
| 5 | M&L for brick work for sub class ‘B’ bricks (old size) straight or curved on plan exceeding 6 meter mean radius built in CM 1:6. complete all as directed. |
| 6 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 incl finished even and smooth (without using extra cement). complete all as specified and directed |
| 7 | M&L for preparation of newly plastered surfaces of wall and applying two coats ofcement base paint over a coat of whtie wash complete all as specified and directed |
| 8 | M&L for 75 mm thick cement concrete 1:3:6 type C-2 , using (40 mm gradedcrushed stone aggregate) as in sub base complete all as specified and directed. |
| 9 | M&L for PCC 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified and directed. |
| 10 | M&L for anti fungus 60 mm thick factory made glazed colour machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006, M-35 Grade, complete all as specified and directed.NOTE :- Make & pattern as approved by GE. |
| 11 | M & L for sand filling/cushioningunder floors/paver block or in foundation incl watering and consolidation complete all as specified and directed. |
| 12 | M & L for cement concrete 1:3:6 type E-2 (using 40 mm graded crushed stone aggregate) in wall or retaining wall, any thickness, size & shape incl pilasters, buttresses columns, pillars, boundary pillars and posts (incl caps and bases)complete all as specified and directed |
| 13 | S&F MS plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-410-W (Gde-E-250) quality-A.complete all as specified and directed. |
| 14 | M&L for steel work in tubular trusses incl special shaped washer etc., complete using ERW or incl butt welded tubes conforming to I.S. 1161-1998 grade St-240 complete all as specified and directed. |
| 15 | M&L for MS Rolled sections of Fe 410W (Gde 250 ) quality \"A\" as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. complete all as specified and directed. |
| 16 | Supply and fix Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall,fixed with self tapping screws as specified.complete all as specified and directed. |
| 17 | M&L for preparation of new steel surface of any descripion over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.. |
| 18 | Removing excavated material(Soil) n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.complete all as specified and directed. |
| 19 | Returning filling in including spreading leveling watering and well ramming in layers n.exc.25 cm. complete all as specified and directed. |
| 20 | Complete removal of existing roof treatment from RCC roof including old hussion felt, tiles etcand preparation of surface with wire brush and cleaning with water complete all as directed. |
| 21 | M&L for rendering 15 mm thick on concrete orbrick surface in CM (1:3) mixed with WPC as per manufacturer\"s instructions and finished surfaces even and smooth with out using extra cement.(Note - WPC will be measured and paid separtely) |
| 22 | Supply only liquid water proofing compound ISI marked |
| 23 | M&L for providing, cement concrete as in roof kerbs or mud stops, filling around hold fast etc. to rounded or chamfered on edges of 1:2:4 Type B 1 (using 20 mm graded stone aggregate) complete all as specified and directed. |
| 24 | M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces complete all as specified and directed |
| 25 | M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed |
| 26 | Dismantling asbestos cement (corrugated or semi corrugated ) sheets in roof covering including hooks complete all asdirected |
| 27 | Supply and fix Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall,fixed with self tapping screws as specified and directed. |
| 28 | Dismantling framed timber scantlings 40 sq. cm and over in section, in any position. complte all as directed |
| 29 | S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats et conforming to I. S 1161-1979 grade St.-240. complte all as directed |
| 30 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), complete all asdirected. |
| 31 | Material and Labour for 16-18mm thick machine cut (table rubbed and polished) granite of any type as in steps, jambs, pillars, cills, cooking platforms like in CM 1:4 including pointing with white cement mixed with admixture of pigment to match the shade of the slab complete including screed bed 15mm thick in CM 1:6 all as specified and as directed by Engr-in-Charge. |
| 32 | M & L for Non Skid ceramic colour ceramic tiles,7 to 8mm thick square/rectangular area of each tile 0.06sqm but not exceeding 0.11sqm ,in floors over and including 15mm thick screed bed in CM(1:6),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfacecoloured cement to match the floor complete all as specified and as directed by Engr-in-Charge. |
| 33 | M&L forNon- skid colour ceramic tiles,7 to 8mm thick square/rectangular area of each tile exc 0.11 sqm but n exc 0.18sqm in floor over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and directed. |
| 34 | All as per sl item No.33 here -in-beforebut in skirting including 10mm thick screed bed in CM(1:4) complete all as specified and as directed by Engr-in-Charge. |
| 35 | M & L for Glazed ceramic tiles in vertical surfaces450x350x7mm thickset and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM 1:4 complete all as specified and directed |
| 36 | Dismantling wall and ceiling board (fibre,pulp,insulations etc)or insulation board any thickness including cover fillets complete all as directed. |
| 37 | M&L for Anodised alumunium snap grid frame work for false ceiling grid of size 605mmx605mm complete hanges from GI wire complete all as specified and as directed. |
| 38 | S&F 4mm thick texture finish type ceiling board fixed to timber/metal framed work with screw as in ceiling snap grid complete all as specified and as directed. |
| 39 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each.complete all as directed. |
| 40 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm but nxec 4sqm each.complete all as directed. |
| 41 | Taking downshutters of any descriptionexc 1 but n exc 2 sq. m each,complete all as directed. |
| 42 | M&L for mild steelframed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified & directed. |
| 43 | S&F Powder coated aluminium windowand ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 44 | S&F pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,complete including filling of PCC 1:3:6 type C0 all as specified and as directed by Engr-in-Charge. |
| 45 | S&F powder coated Aluminium three track sliding glazed window manufactured with approved aluminium section with three sliding shutters each shutter width one half of the length of window with the following specifiecation and making good the adjascent surfaces :-(a) Window frame of cross section 101mmx40mmx1.5mm thick.(b) Three way track for smooth slding shutters of cross sections 91.80mmx31.75mmx1.1mm thick. (c) Sliding shutter frame of cross section 40x18x1mm.(d) Aluminium glazing stip of size 18.2x16.66mm. (e)5mm thick flat glass superior quality for two shutter. (f) IDPE rubber gasket for fixing glass. (g) Locking cleat/device as shutter 01 Nos. (h) 02 Nos sliding roller per shutters. (j)aluminium wire cloth 0.36mm stainless steel nominal dia of wire and average width of aperature 1.40mm for one shutter.(k) Fixing screws for frame with wall 06 per window with fancy design.(Note: Window will be measured outer to outer frame and no extra to be paid.) |
| 46 | S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawingcomplete all as specified and as directed by Engr-in-Charge. |
| 47 | Supply and fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame as per specification & drawing complete all as specified and as directed by Engr-in-Charge. |
| 48 | S&F Plain framed, panelled shutter (two panel) factory made 35 mm thickof 2nd class HW rail and stylewith lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), Kiln seasoned and chemically pressure treated,. complete all as specified and directed. |
| 49 | S&F second class hardwood glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part - I,Section 8 Clause 8.24(a) supplied and fitted to chowkats complete all as specified and directed. |
| 50 | S&F 140mm floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor |
| 51 | S&F mild steel sliding door bolts 300mm long complete all as specified and as directed by Engr-in-Charge. |
| 52 | S&F 100mm size MS butt hinges, medium weight cold rolled complete all as specified and as directed by Engr-in-Charge. |
| 53 | S & F 150mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by Engr-in-Charge. |
| 54 | S & F 150mm long Aluminium handle cast type anodised complete all as specified and as directed by Engr-in-Charge. |
| 55 | M & L forpreparation of new surface on wooden surface exc 10 cm width/girth & apply two coats of synthetic enamel paint over one coat of pink primer complete all as specified anddirected by Engr-in-Charge. |
| 56 | M&L for preparation of old painted steel surfaces of any description over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint complete all as specified and as directed. |
| 57 | S&F in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks, or galvanised wire staples fixed complete all as specified & directed. |
| 58 | Taking down cement plaster on brick or concrete or stone walls etc including racking out joints hacking for key scrubbing down with water any description complete all asdirected.. |
| 59 | M&L for rendering 15 mm thick in cement mortar 1:6on wall of brick work or concretesurface, finished fair and even (without using extra cement) all as specified and directed. |
| 60 | M&L forrendering 5 mm thick in cement mortar 1:3on ceilingof brick or concretesurface, finished even and smooth without using extra cement all as specified and directed. |
| 61 | M&L forrepair and rendering 10mm thickin CM 1 :3on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete includingcleaning of viisible reinforcementandtreating with cement slurry also necessary repair to cracked concreteif any with cement concrete1:2:4 Type B-0 using 12.5mm graded stone aggregateincluding necessary scafolding work for double/single storey bldgs complete all as specified & directed. |
| 62 | M&L for applying 3mm thick wall care putty to make colours scheme and good or rubbing smooth old diffrent colours paintedwall surfaces completed all as specified and directed |
| 63 | M&L for applying 3mm thick wall care putty to make colours scheme and good or rubbing smooth old diffrent colours paintedceiling surfaces completed all as spd and directed |
| 64 | Material and labour for preparation of OLD plastered surfaces of ceiling and applying one coat of oil bound distemer complete all as specified & directed. |
| 65 | Material and labour for preparation of NEW plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 66 | Materials & labour for prepration of NEW plastered surface and finishing the surfaces of wallwith wall putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of colour as approved by GE, complete all as specified & directed. |
| 67 | Materials & labour for prepration of OLD plastered surface and finishing the surfaces of wallwith wall putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. |
| 68 | Material & Labour for preparation of new plastered surfaces applying Two or more coats of 100% Premium acrylic emulsion two bounded chemical paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified & directed.. |
| 69 | Complete removal of old painted surfaces includingpreparation of old plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified & directed.. |
| 70 | Disconnecting exisiting tanks and re-fixing in position including repairs if any requirement, capacity of tanks exc 500 ltrs and not exc 1000 ltrscomplete all asas directed by Engr-in-Charge. |
| 71 | S&F 1000 ltr capacity rotational moulded polyethylene water storage tank (cylindrical vertical closed top) double layered hoisted and fixed in positions, including 20mm dia of ball valved high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe and fixed with anti microbial property complete all as specified & directed.. |
| 72 | Taking down eaves gutters and rain water pipes (any ize or patterns)including all heads,shoes,bends,swan-necks etc complete all asdirected.. |
| 73 | S&F PVC(SWR) floor trap 75mm dia plain with grating incl jointing with solvent cement complete all as directed.. |
| 74 | S&F PVC(SWR)pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp complete all as specified & directed.. |
| 75 | S&FPVC (SWR) bend of radius 110mm dia complete all as specified & directed. |
| 76 | S&FPVC(SWR) Tee of radius 110mm dia complete all as specified & directed. |
| 77 | S&FPVC (SWR) vent cowl 110mm dia complete all as specified & directed. |
| 78 | S&F in repairs PVC valveless syphonic action with flushing system fancy type low level flushing cistern 10 ltr. Capacity of approved incl flush pipe of 32mm bore and all as specified and directed. |
| 79 | S&F in repair PVC Connections 15mm size with PTMT nuts of length 450mm including washer all as specified and directed. . |
| 80 | Supply and fixing in repairs vitreous china urinal , half stall type, whitewith grating and union for discharge pipe (excluding flushing cistern,flush pipe and waste pipe) complete all as specified and directed. |
| 81 | S&F in repair vitreous china squatting pan , Orissa pattern size 580 x 440 mm white, with integral foot rest including connection to trap, and to flush pipe, anti-syphonage etc. complete all as directed. |
| 82 | Supplied and fixed in repair vitreous china WHB white flat back size 550x400mm including Supplied and fixed angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed. |
| 83 | S&F in repair 15mm dia bore, stop valve but long shank (concealed type), cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in pipe and all as specified and directed |
| 84 | S&F in repair brass chromium plated shower rose with arm 125mm size complete all as specified and as directed by Engr-in-Charge. |
| 85 | Supply & fix in reapir Stop/angular valve, 15 mm dia, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down, high pressure screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified & directed. |
| 86 | Supply & fix in repair bib taps cast copper alloychromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore, complete all as specified & directed. |
| 87 | S&F as in repairs pillar tap cast 15mm bore copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without lettred head `HOT\" or `COLD\" with long screwed shank and flynuts screwed for iron pipe all as specified and directed by Engineer-in-Charge. |
| 88 | S&F as in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commerial ply wood or AC building board and fixed to wooden plugs with chromium plated brass screwes and cup washer complete (with fancy design)all as specified and directed. |
| 89 | Taking up or down steel tubing and connections including for refixing or removal 15mm bore complete all as directed by Engr-in-Charge. |
| 90 | All as per item No 89 here-in-before but 20mm bore complete |
| 91 | S&F tubes medium grade galvanised with all fittings & fixed complete to walls & ceiling or laid in floors 15mm bore etc complete all as specified and directed . |
| 92 | S&F tubes medium grade galvanised with all fittings & fixed complete to walls & ceiling or laid in floors 20mm bore etc complete all as specified and directed . |
| 93 | S&F in repairs decorative curtain rod made out of 25mm dia (outer dia) MS pipe having wall thickness 0.63mm, PVC coated of any colour and pattern as approved overall dia 28 to 28mm, includiing and including two nos brackets on each ends alongwith globe on each ends for earch window/door fro fixing complete all as specified and directed with fancy design and approved by engineer-in-Charge. |
| 94 | Demolition of cement concrete in ground floors and paving exc 15cm thickness(below or above ground level) complete all asdirected. |
| 95 | M & L for 75 mm thick cement concrete 1:3:6 type C-2using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm thick joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed. |
| 96 | M7L forPCC 1:2:4 type B1 using 20mm graded stone aggregate as in padding, hold fasts/filling of chowkhats or similar work complete all as specified and as directed by Engr-in-Charge. |
| 97 | M&L for plain cement concrete 1:5:10 type E-2 ,using 40 mm graded stone aggregate as in filling around shunken areas complete all as specified and directed. |
| 98 | M&L for 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate mixed with WPC as in sunken portion and making adequate slope toward spout pipe complete all as specified and as directed.( Note: - Water Proofing Compound shall be measured and paid separately) |
| 99 | M&L for rendering 15 mm thick on concrete orbrick surface in CM (1:3) mixed with WPC as per manufacturer\"s instructions and finishes surfaces even and smooth with out using extra cement.(Note - WPC will be measured and paid separtely) |
| 100 | M&L for applying two coats evenly a tack coat of hot air blown bitumen of grade 85/25 @ 1.50 Kg per sqm per coat (one coat overplaster and one coat on polythene film) including cleaning of surface over polythene film complete all as specified and as directed |
| 101 | M&L for polythene film black 200 micron thick laid in floor, vertical surface etc complete all as specified and directed. |
| 102 | M&L 100 mm thick cement concrete in foundations/sub base of floor in cement morter (1:3:6) type C-2 using 40 mm graded stone aggregate complete all as specified and as directed by Engr-in-Charge. |
| 103 | M&L for chequered cement concrete tiles with grey cement and no pigment 30cmx30cmx25mm thick over and incl 15mm thick screed bed in CM 1:6 set jointed and pointed in neat cement slurry in floors complete all as specified and as directed by Engr-in-Charge. |
| 104 | Demolition ofBrick/stone works masonry, built in cement mortar or cement limemortar including all quoins, arches, pillars etc but excludingashlar facing, dressed stone work andpre-cast concrete articles complete all as specified and as directed by Engr-in-Charge. |
| 105 | M&L for brick work using sub class B brick curved or straight on plan to any radius in half brick wall builit in CM(1:4)complete all as specified and as directed by Engr-in-Charge. |
| 106 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as directed. |
| 107 | Taking down carefully copper/aluminium sub main wiring of size 4&6 sqmm from surface/concealed at any height and removing the materials from site and making good thedisturbed surfaces of walls,floors roofs etc complete all asdirected. |
| 108 | Taking down old/unserviceable MCB DB SPN/TPN any capacity by disconnection of electric connectionincludingMCBs,Isolators,etc and making good to disturbed surface complete all asdirected. |
| 109 | M&L forpoint wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC concealed conduit 20/25 mm dia medium gradeon wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed.Note: Therate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing ofswitch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces. |
| 110 | All as per Ser item No 109 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 111 | All as per Ser item No 109 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 112 | All as per Ser item No 109 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 113 | S&F Switch modular 1 way 6 Amps single pole complete all as specified & directed. |
| 114 | S&F Switch modular singlepole , one way 16 Amps complete all as specified and directed. |
| 115 | S&F Socket modular 2/3 pin combined 6 Amps complete all as specified and directed. |
| 116 | S&F Socket modular 2/3 pin combined 6/16 Amps complete all as specified & directed. |
| 117 | S&FCeiling rose,3 terminal PVC/polycarbonatecomplete all as specified and directed. |
| 118 | S&F modular fan regulator step type, 230 Volts single phase 120 wattcomplete all as specified and directed at site. |
| 119 | M&L for submain complete with 2X4 Sqmm , single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia medium grade as per site requirement along walls/ceilingetc including 1X 4.0 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces.(iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length) |
| 120 | All as per ser item No-119 here-in-beforebut 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire |
| 121 | Supply and fixMCBDB SPN 8 way double door with metal door suitable forhousing of MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. |
| 122 | Supply and fix MCBDB TPN 4 way with metal door suitable forProvision ofincommer and out going MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 123 | Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed at site. |
| 124 | S&F in replacement ofMCB SP 6 to 32 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 125 | S&F in replacement of MCB DP 40Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.. |
| 126 | S&F in replacement ofisolator DP 63 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 127 | S&F in replacement of LEDtube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting withaluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed at site. |
| 128 | S&F in replacement of 9 watt LED mirror light with polycarbonate housing & intergrated electronic driver including all internalluy prewired and connecting with twin core twisted flexible copper conductor cable complete all as specified and directed. |
| 129 | S&F ceiling fan 230 volts, 50 Hz 1200mm sweep with down rods, canopy, blades, BLDC motor and remote etc complete with service value of the fan shall be greater than 6.1 as per BIS including necessary electric connection from ceiling rose to fan terminal with writing MES No with synthetic enamel black paint including taking down old fan and deposited to MES store yard complete all as specified and directed. |
| 130 | S&F sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps to 32 Amps complete all as specified anddirected at site. |
| 131 | S&F in replacement of building LED security light fitting 40 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 Built in super protection device.luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site. |
| 132 | S&F in replacementPVC ventilating airfan single phase300 mm sweepcomplete with louver shutter and including makingof hole suitablesizefan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed. |
| 133 | Supply, laying,testing and commissioning for 1100 Volts gradeXLPEinsulated PVC sheathed steel armouredalluminium stranded conductorof 35 sqmm 3 1/2 core . LT UG Cables (conforming to IS 1554) in trenches / ducts /through RCC pipes under roads icluding takig out old cable and removing from site complete all as specified and directed . NOTE:- (i) Excavation & eartwork shall be measured and paid separately.(ii)Sand and Bricks shall be measured and paid separately under supply only items. |
| 134 | Excavation intrenches in loose/soft soil not exceeding 1.5 metrewide and not exceeding 1.5 metredeep for laying of cables,poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete all as specified and directed . |
| 135 | Supply and laying river sand cushioning to underground cables with 8 CM thick before laying of cables and 15 cm thick after laying and stretching of cable complete all as specified and directed.Note : Punned down thickness shall be considered for measurement . |
| 136 | Supply and layingOld size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed. |
| 137 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of depth not less than 0.90x 0.60 x 2.25 mtr below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earthstripof size 25x3 mm, 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth lead protection pipe light gade GI of size 32/40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I connected to earthing lead with Main switch/main control board,filling with charcoal dust 200 Kg, and common salt 100 KG ,including necessary excavation and earth work in any type of soil ,perforated watering pipe,funnel with wire mesh,earth lead protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1, 450 x450 x50 mm thick with 8 mm dia TMT bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EICNote :(i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm top of GI Plate. |
| 138 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy