| 1 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/ laying CI/GI/DI pipes and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Removing excavated soil at a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 3 | Returning,filling in including spreading, leveling, watering and well rumming in layers not exc 25 cm complete all as specified and directed. |
| 4 | M&L for cutting road, concreate surface for laying of DI/MS pipe and making good of disturbed surface complete all as specified and directed. |
| 5 | M & L for double layer self supporting steel scafolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of both workers andthe buildings having above 20m height complete all as specified anddirected |
| 6 | M&L for cutting of 150mm MS pipe line and including fixing of any type of MS fitting for connecting new pipe complete all as specified and directed. |
| 7 | Taking up the deterinated/leakage MS pipes & connected unserviceable valves, etc. of any size from trenches/ floors/wallsof different sizes for replacing with necessary fittings and valves etc complete all as directed for size mentioned here-in-after:- |
| 8 | MS pipe 150 mm bore. |
| 9 | MS pipe 100mm bore. |
| 10 | MS pipe 80mm bore. |
| 11 | Supply and fixingMS Pipes 100 mm dia heavy grade conforming to IS 1239:1990 complete with all fittings laid in floors or fixed to walls and ceilings etc including connection of pipe and valve by carrying out necessary welding, suitable size of nuts and bolts, washers etc including necessary supporting arrangement for fixing rising pipe in high rise bldg and scoffolding works up to 12th floor complete all as specified and directed .Note: a) Care of labours working on multistoried bldg shall be the responsibility of the contractor .b) Pipe jointing material such as Flange joints, bends, and suporting clamps on wall will be measured and paid separatelyc) Cost of welding is deemed to be included in the quoted rate |
| 12 | All as per item No. 11.00 mentioned here-in-before but for MS pipe 80 mm |
| 13 | Supply and fixingMS Pipes 80 mm dia heavy grade with flanged end conforming to IS 1239:1990 complete with all fittings laid in trenches in ground including necessary connection of pipe, welding/jointing complete all as specified and directed . |
| 14 | All as per item No. 13.00 mentioned here-in-before but 100 mm dia |
| 15 | All as per item No. 13.00 mentioned here-in-before but 150 mm dia |
| 16 | S&F CI sluice valve (class PN 1:6) 80mm bore ISI market with SS spindle both ends flanger iron wheel with necessary size of gaskets nuts, both wasehr etc complete including taking down the unserviceable all as specifed & directed, Make : Upadhayay/Kalpana |
| 17 | All as per item No. 16.00 mentioned here-in-before but for 100 mm dia |
| 18 | Disconnecting/ dismantling ,Suppply and fix as in repair Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm. with doubledoor with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard fixed in the premises of the bldg including dismantling fire hose cabinet complete all as specified and as directed by Engr-in-Charge. |
| 19 | Disconnecting, supply & fix hydrant valve single headed conforming to IS-5290 with 80 NB flanged inlet,63mm oblique outlet ,stainless steel body,CI hand wheel F4-200 as per IS-210,phosphor Bronze string IS-7608 including taking down of old unserviceable one complete all as specified and as directed. |
| 20 | Disconnecting , supply and fix as in repairRubber hose reel of 20mm dia and 30 metre length with reel drum including stainles steel (SS) shut off nozzle conforming to IS 5132 including taking down of old unserviceable one complete all as specified and as directed . |
| 21 | Disconnecting , supply and fix as in repair 63 mm dia 15 meter long canvasnon-percolating flexible delivery hose conforming to IS 636-1988 complete with SS male and female delivery coupling made conforming to IS 903 including taking down of old unserviceable one complete all as specified and as directed . |
| 22 | Disconnecting, Supply and fix as in repair Branch pipe stainless steel 63mm instantaneous inlet, made threaded outlet,15mm bore nozzle short including taking down of old unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 23 | Disconnecting, Supply & fixing as in repair SS adapter for 63 mm fire hydrant valve conforming to IS: 903 including taking down of old unserviceable one complete all as specified and as directed by Engr-in-Charge |
| 24 | Disconnecting, Supply and fixing as in repair Fire brigade inlet connection 150 mm dia, 4 way including taking down of old unserviceable one complete all as specified and as directed by Engr-in-Charge |
| 25 | Supply and fixing as in repair fire hydrant stand post,made up of 80-150 mm dia heavy duty MS pipe,1.5 mtr height, flanged type stand post position as per site requirment including disconnecting and taking down old one, necessary earth work, new fibre board gasket and nut, bolt & washers complete all as directed |
| 26 | S&F 20mm dia ball brass valves, high pressure with polyethylene float and flynut complete screwed for iron pipe or brass ferrule and fixed including taking down of old unserviceable one completeall as specified and directed by Engr-in-charge. |
| 27 | S&F 25mm dia ball brass valves, high pressure with polyethylene float and flynut complete screwed for iron pipe or brass ferrule and fixed including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 28 | S&F 15mm dia ball brass valves, high pressure with polyethylene float and flynut complete screwed for iron pipe or brass ferrule and fixed including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 29 | Supply and fixing Pressure guage 4\" dial having pressure rating 0-14 Kgs for fire fightiing system including taking down of old unserviceable one complete all as specified and directed. |
| 30 | M&L for fixing Sheet glass of 4mm thickness in hose box door, ordinary quality and glazing with oil putty in rectangular shape n exc 0.5 sqm in each pane including taking down of old unserviceable one complete all as specified and directed. |
| 31 | M&L for painting Hose box/ windowwith two coats of synthetic enamel paint red in colour over a coat of red oxide primer after removing/ scrubbing old painted/ rusted surface complete all as specified and directed. |
| 32 | M&L for painting pipe upto 200mm diawith two coats of synthetic enamel paint red in colour over a coat of red oxide primer after removing/ scrubbing old painted/ rusted surface complete all as specified and directed. |
| 33 | Taking down carefully electric driven centrifugal pump setof any capacity from MS channels frame in foundation after disconnecting all pipes / main electric supply from motor starter panel and keeping the MS channel frame at site for repairs/painting and carrying the pump set to nearest repairing workshop including bring back after necessaryrepair complete all as directed by Engr-in-charge. |
| 34 | Overhauling of centrifugal pump of capacity 12.5 HP/15HP for cleaning, Greasing, minor repairs to pump & motor including replacement of spares parts like clamps, shaft sleeve, Bearing, Water ring, Inter Stage Ring, PVC Air Vent, Air release nozzles of brass for pump, Water deflector, impeller check nut, Body stud Bolt & Nuts, Coupling PVC Bush, S Nuts and Bolts of iron full thread with washers,Gaskets, etc & connected minor accessories including refixing all disconnected spare parts, checking for alignment with motor and reassembling complete all as specified and directed.Note: Major spares like impeller, shaft, stage bushing, coupling, ball bearing will be measured and paid seperately under respective items. |
| 35 | Dismantling and opening the motor frompump set of capacity 12.5 HP/15HP in existing position for carrying out rewinding work with super enamelled copper wire of suitable gauge as per existing conforming to IS 13730 and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same with pump in original position complete all as specified and directed. |
| 36 | Supply only of spare parts mentioned here-in-afterfor pump set including motor complete for 12.5/15 HP centrifugal pump:- |
| 37 | Impeller |
| 38 | Shaft |
| 39 | Stage bushing |
| 40 | Coupling |
| 41 | Bearing as per sample |
| 42 | Complete casing |
| 43 | M & L painting of 12.5/15 HP capacity centrifugal pump set including MS channel after removing old painted/rusted surface by paint removers such as blow lamps, scrapers etc over the surface of motor/pump/MS chanel and painting with two coat of synthetic enamelled paint over a coat of red oxide primer and shall be painted with approved colour as directed omplete all as specified and as directed by Engr-in-Charge. |
| 44 | Supply and fixing in repair CI screwed end single Air valve size 20 mm diaas per IS:14845, PN-1.6, including taking down of old unserviceable one complete all as specified and directed by E-in-Charge |
| 45 | M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zinc Chrome and two coats of synthetic enamel paint including taking down of old unserviceable one all as specified and directed. |
| 46 | S & F MS bend 150mm dia flange type any /with angle holes , nut bolts etc including welding and taking down of old unserviceable one complete as specifiedand directed. |
| 47 | S & F MS bend 100mm dia flange type any /with angle holes , nut bolts etc including welding and taking down of old unserviceable one complete as specifiedand directed. |
| 48 | S & F MS bend 80mm dia flange type any /with angle holes , nut bolts etc including welding and taking down of old unserviceable one complete as specifiedand directed. |
| 49 | M & L for flanged joints of MS pipe 150mm dia with rubber or fibre board gasket, nuts, bolts etc including welding and taking down of old unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 50 | All as per Srl item No. 50.00 mentioned here-in-before but for 100mm dia pipe |
| 51 | All as per Srl item item No. 50.00 mentioned here-in-before but for 80mm dia pipe |
| 52 | Material and labour for construction of masonary Inspection pit of size 1000x1000x900mm internally with burnt brick (Sub class \"B\") full brick thick brick work in cement mortor (1:6), 10 mm thick plastering in CM(1:4) internally and externally upto 150mm below the ground level, 150mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregated) as in foundation bed with 150mm all round ofset from outer side of brick work, 3 mm thick MS sheet cover with locking arrangement hinged with 50 x 50 x 6 mm angle iron frame embeded in PCC (1:3:6) type C-1 (using 20mm graded stone aggregated) as coping etc including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on steel surfaces including necessary earth work in soft/loose soil including taking down of old unserviceable one complete all as specified and as directed. |
| 53 | M&L Mild steel window as per existing size, shape and design or otherwise indicated or directed and inclusive of one primer coat with red oxide Zinc Chrome and two coats of synthetic enamel paint complete including fixing and taking down old unserviceable one complete all as specified and directed. |
| 54 | Material and labour for repair of Electical panel of fire pump by carrying out replacing thoroughly all electrical connections wires as per existing circuit and size, replacing contactors, CT coil, MCBs if required as per existing model and checking, voltmeter, ammeter , tightening all connections properly with proper size of new nut, bolt, washer as per the site requirements including welding on damage panel and preparation of surfaces internal and external of panels/feeder piller boxes by cleaning with dry cloth /removal dust particles by using air blower and scratching the old painted surfaces as directed and painting with two coats of synthetic enamel paint over a coat of red oxide primer and rewriting existing letters /numbers as directed and testing on completion showing tha automatic / manual control complete as per direction.Note:- Cost of taking down, refixing, Painting, Nuts, bolts, washer etc. are deemed to be included in quoted rates. |
| 55 | S & F pressure switch universal type including taking down of old unserviceable complete all as specified and directed. |
| 56 | S&F Ampere meter, digital type, 0-500 Amps with in-built selector switch, complete with suitable size of CT\"s,including taking down of old unserviceable complete all as specified. |
| 57 | S&F Volt-Ampere meter,analog type, 500V 60A with in-built selector switch, complete with suitable size of CT\"s,including taking down of old unserviceable complete all as specified. |
| 58 | S&F Indicator lamp, LED type of colour red, blue and yellow including taking down of old unserviceable complete all as specified. |
| 59 | M & L for earthing wire from pump motor to panel with 4mm wire including taking down of old unserviceable complete all as specified and directed. |
| 60 | S&F Push button in the panel including taking down of old unserviceable complete all as specified and as directed by Engr-in-Charge |
| 61 | S&F Auto manual switch including taking down of old unserviceable complete all as specified and as directed by Engr-in-Charge |
| 62 | S & F in repair expansion valve 80/100/150 mm dia flanged type including nuts, bolt and gasket including taking down of old unserviceablecomplete all as specified and directed. |
| 63 | M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate to form base of pump completeall as specified & directed including demoltion of old PCC/broken PCC and removing it to distance not more than 50m from MES Installation. |
| 64 | Supply & fixing in position ISI marked 150 mm nominal bore cast iron double flanged Non Return Valves as per IS : 5312, part- I, suitable for pressure 15 KG/cm2, including transportation to worksite, supply &fixing nuts, bolts, gaskets and washers etc. complete including testing all as specified and directed. |
| 65 | All as per item No. 65.00 mentioned here-in-before but 100mm nominal bore |
| 66 | Supply, Fixing, testing and commissioning of local fire alarm control and indicating panel (Control Panel- 12 Zone)with indicating lights etc. complete in all perspects for proper working of the system and as per specification. The control wires between the local control panel and the main control panel should be monitored and give a fault indication at the main panel in theevent of the fault including taking down of old unserviceable complete all as specified and directed.- Fyrex/ Minimax |
| 67 | S&F MCP (Manual control Point) with housing powder coated including chain hammer to break glass including taking down of old unserviceable completed all as specified and directed. |
| 68 | S&F Hooter 100 db output 24 volt dc operated all with abs housing including taking down of old unserviceable complete all as specified and directed. |
| 69 | Supply and fixing control wiring of MCP and hooter with 2 runs of 1.5 sqmm FRLSH PVC insulated copper conductor wire in 25mm PVC heavy duty casing caping/ conduit pipecomplete including taking out old unserviceable wirings all as specified anddirected. |
| 70 | Taking down carefully copper/ aluminium point for MCP(Manual control Point) point buzzer 45 point control panel complete including fittings/fixtures etc including taking down of old unserviceable complete all as specified and directed. |