Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" Part - I (BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:- |
| 2 | SCHEDULE \"A\" PART- II ( SITE CLEARENCEAND AREA DEVELOPMENT) Details of prepriced Schedule is given in tender documents |
| 3 | SCHEDULE \"A\" PART- III( INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 4 | SCHEDULE \"A\" PART-IV ( INTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents. |
| 5 | SCHEDULE \"A\" PART- V (ROADS / PATHS / CULVERTS)Details of prepriced Schedule is given in tender documents. |
| 6 | SCHEDULE \"A\" PART- VI (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents |
| 7 | SCHEDULE \"A\" PART- VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents |
| 8 | SCHEDULE \"A\" PART- VIII (EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 9 | SCHEDULE \"A\" PART- IX(EXTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 10 | SCHEDULE \"A\" PART- X(STREET/SECURITY LIGHT )Details of prepriced Schedule is given in tender documents. |
| 11 | SCHEDULE \"A\" PART- XI(DEMOLITION)Details of prepriced Schedule is given in tender documents. |
| 12 | SCHEDULE \"A\" PART -XII (MISCELLANEOUS ITEMS)Note:- This scheduleis not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.\" F \" signifies this fact only. |
| 13 | SITE CLEARENCEAND AREA DEVELOPMENTM&L for forming embankment with approved earth including raising or lowering earth spreading in layers not exc 30 cm thick watering, ramming and rolling and finishing to required size & shape not exc 1.50 m height from base complete all as specified and as directed.Note. Approved earth as per classification of soil based on latest IRC/MoRTH specification required for forming embankment to be obtain from outside of MoD land. |
| 14 | INTERNAL ELECTRIFICATIONSupply and fixing Modular metal fluxh box with modular white cover plate with frame 8 module complete all as specified and directed. |
| 15 | S&F LED security light fitting not less than1x35 watt of minimum lumen efficiency of 110 lm/W with integral reflector made of aluminium alloy LM6 with LED driver, lamp, surge protector and all accessories pre wired including connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with GI bracket 1.5M long bend to shape of dia. 25/40 mm GI medium grade pipe with MS clamp including two coats of aluminium paint over a coat of red oxide primer and necessary fixing fasteners, complete all as specified and directed. |
| 16 | Supply and fixing thermal foam insulation with glass wool& aluminium covered pipe for GI pipe self adhesive pipe foam thickness 5mm, suitable for 25mm GI pipe for protection to hot water pipe complete all as specified and directed. |
| 17 | Supply and fixing thermal foam insulation with glass wool& aluminium covered pipe for GI pipe self adhesive pipe foam thickness 5mm, suitable for 15mm GI pipe for protection to hot water pipe complete all as specified and directed. |
| 18 | Supply and fix concealed MCCB distribution box, double door, vertical type, TPN, 415 V, 6 way IP 43 suitable for MCCB of 100 Amps, 4 Pole, 25 KA as incomer and MCB SP/TP as outgoing complete with suitable busbar, neutral link, earth link complete all as specified and directed.Note:- (i) MCCB/MCBs shall be measured and paid saperately.(ii) Blank space shall be covered with blank plates and cost for same shall be deemed to be included in the item quoted rate. |
| 19 | Supply and fix concealed MCCB distribution box, double door, vertical type, TPN, 415 V, 8 way IP 43 suitable for MCCB of 63 Amps, 4 Pole, 25 KA as incomer and MCB SP/TP as outgoing complete with suitable busbar, neutral link, earth link complete all as specified and directed.Note:- (i) MCCB/MCBs shall be measured and paid saperately.(ii) Blank space shall be covered with blank plates and cost for same shall be deemed to be included in the item quoted rate. |
| 20 | Supply and fix MCCB 415 Volts, 4 Pole, 100 Amps, 50 Hz, 25 KA with thermal magnetic release adjustable type Ics=100% Icu including necessary spreader links complete all as specified and directed. |
| 21 | Supply and fix MCCB 415 Volts, 4 Pole, 63 Amps, 50 Hz, 25 KA with thermal magnetic release adjustable type Ics=100% Icu including necessary spreader links type complete all as specified and directed. |
| 22 | Supply and fixingminiature circuit breaker (MCB) SPNof upto20 amp rating 240V, 10KA \"C\" curve and 10 KA current carrying capacity in the MCB DB complete with connection testing and commissioning,complete all as specified and directed. |
| 23 | M&L for three phase sub main wiring with 4 run of FRLSH type PVC insulated & unsheathed multi stranded copper conductor cable of cross secion area10.0Sqmm (Nominal area) alongwith 2 run of FRLSH type PVC insulated & unsheathed multi stranded copper conductor cable of cross secion area10.0Sqmm (Nominal area) as earth continuity conductor drawn through and including concealed PVC Conduit non metalic type rigid medium grade of size not less than 40 mm complete all as specified and as directed.NOTE : 4 run of submain wiring cable alongwith 2 run of earth wire including PVC conduit shall be measured as one length. |
| 24 | M&L Earthing complete with galvanized steel earth plate electrode 600mm x600mm x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected with galvanized 4 mm dia earth wire as earthing lead upto 7.5 mtrs from testing point fixed by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 25mm bore medium grade galvanised iron pipe and other endconnected to earthing test point including funnel with watering pipe of 20mm bore medium grade galvanised iron wire mesh charcoal or cock and common salt in alternate layer of 15cm (compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1 50mm thick precast RCC (1:2:4) B1 nominal mix cover slab of size 450mmx450mm reinforced with 8mm dia TMT bar 100mm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in any type of soil and deposite surplus soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No 3 of MES Shedule Part -lcomplete all as specified and directed.Note:- The quoted rate of above item includes supply and fixing of earth identification plate as directed and necessary weather coat paint on exposed part of earth pit complete all as directed. |
| 25 | Supply and fixing PVC Blank plate 1-module in Modular cover plate to cover blank spaces complete all as specified and directed. |
| 26 | INTERNAL WATER SUPPLYS&F brass angle stop cock CP high pressure with capstan head long shank screwed down 15mm dia. bore complete all as specified and directed. |
| 27 | ROADS/PATH/CULVERTMaterial & Labour for 300mm thick GSB (Granular Sub-Base) grade V as per Table 400-1 of MORTH/ IRC Specification,over compacted sub grade with stone aggregate of specified grading by using mechanical paver/Grader, spreading in two layer 150 mm each, watering, ramming/ rolling by tandem vibrator roller & consolidating to required gradient and required camber using earth compactor of min 8 to 15 tonne or compaction methodology recommended by soil agency at OMC to achieve field compaction at least to 98% of MDD (Maximum Dry Density) determined using modified proctor density determination method as per IS code complete all as specified and directed. |
| 28 | Material & Labour for providing 100 mm thick (compacted thickness) Wet Mix Macadam (WMM) in two layers (each layer50 mm thick, compacted separately) with crushed stoneaggregate of specified grading, spread using mechanical sensor paver / grader as specified, rolled and consolidated using 8 to 10 tonne capacity tandom vibratory power roller to required gradient and camber to achieve minimum 98% density of MDD determined using modified procter density determination method as per IS 2720(Part-8) and as per MORTH clause 406 for NEW RIGID PAVEMENT, complete all as specified and directed. |
| 29 | SEWAGE DISPOSALM&L forRCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 usersas per shown in drawing complete all as specified and directed. |
| 30 | M & L RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users as per shown in drawing complete all as specified and directed. |
| 31 | M&L for construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 2.25M inner dia X 3.0 M effective depth as per shown in drawing complete all as specified and directed. |
| 32 | M&L for construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 3.25M inner dia X 3.0 M effective depth complete all as specified and directed. |
| 33 | EXTERNAL WATER SUPPLYM&L for drilling of Trial bore of 200 mm dia upto 200 mtrs depth below ground level by any suitable method as per soil condition and CGWB report, through any kind of soil, boulders, rocks etc. for a bore size 250 x 150 mm dia as required at site including disposal of spoil from the site of work complete all as specified and directed.NOTE :(i) After complete drilling of the borehole electric logging to be carried out for exact selection of strata & the same will be measured & paid separately under relevant items of schedule.(ii) In case the results of the borehole/strata are found un-satisfactory & the tubewell is not likely to yield the specified quantity of water, the site shall be abandoned & the contractor shall be paid for the boring part only. |
| 34 | M&L for development of trial bore by reaming upto 525 mm for 200 mtrs depth from ground level using any suitable method as per soil condition and CGWB report including disposal of spoil from the site of work complete all as specified and directed. |
| 35 | Carrying out Electric logging Test of bore for precise delineation of granular zones & also the quality of ground water including report interpretation complete all as specified and directed.NOTE:- Electric logging shall be carried out by any approved Govt Agency. |
| 36 | Supplying and assembling including jointing, lowering & fixing in position threaded uPVC casing pipe of 250 mm dia nominal size (internal), 12.5 mm wall thickness (Min), Class CM, as per IS 12818 : 2010(ISI marked) of suitable length including socket and jointing materials,complete all as specified and as directed. |
| 37 | Supplying and assembling including jointing, lowering & fixing in position threaded uPVC casing pipe of 150 mm dia nominal size (internal), 7.5 mm wall thickness (Min), Class CM,as per IS 12818 : 2010(ISI marked) of suitable length including socket and jointing materials, complete all as specified and as directed. |
| 38 | Material and labour for packing pea graval 3 to 5 mm of size as per IS of natural shapebrought directly from river bed and packing around the casing pipe to entire depth upto ground level complete all as specified and as directed. |
| 39 | S&F MS centralising guide, made out of MS flat iron 40x6 mm and 30 cm length all as specified as IS : 2800 (Part – 1) : 1991 complete all as specified and as directed. |
| 40 | Supplying and assembling including jointing, lowering & fixing in position threaded uPVC Screen slotted casing pipe of 150 mm dia nominal size (internal), 7.5 mm wall thickness (Min), Class CM, with slot 1 mmas per IS 12818 : 2010(ISI marked) of suitable length including socket and jointing materials,complete all as specified and directed. |
| 41 | Supply and fixing well cap suitable for 250 mm bore housing pipe made out of 6 mm thick steel plate complete all as specified and directed. NOTE : After completion of the work well cap will be used to keep the bore well closed until the submersible pumping set is installed. |
| 42 | M&L for development of tube well with air compressor of suitable capacity till sand/mud free water of potable quality is obtained & to achieve minimum discharge capacity of 48000 LPH/max yeild(Compressor with accessories & tube etc. shall be arranged by the contractor) complete all as specified and as directed. |
| 43 | Development of tube well by over pumping 25% using suitable size/type of pump after completion of item above, including yield testing for tube wellas per IS requirements complete all as specified and as directed. NOTE :-Yield test of bore well shall be carried outin the presence of rep of Accepting Officer. |
| 44 | Supplyonly strata sample box with glass cover 3mm thick having internaldimension 1000x600x100mm made out of 20mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various depthevenly 2 mtr interval met in boring including strata chart in duplicate complete all as specified and as directed |
| 45 | Testing of water (Raw Water & Treated Water) from approved Govt lab for potability by doing chemical and bacteriological analysis as per norms of WHO and submission of test reports to the to the Dept for entire satisfaction of the Dept. complete all as specified and as directed |
| 46 | Supply, lowering, jointing & testing MS Black column pipe3.0 mtr long, heavy duty, 80 mm bore, wall thickness 4.85 mm, both ends flanged, ISI Marked with heavy duty MS flanges not less than 20 mm screwed & welded inside & outside with pre-drilled holes including jointing with rubber gasket, nuts, bolts, washers & necessary grooves for facilitating submersible cables, steel ropes etc. The pipe shall be duly painted with anti-corrosive paint suitable for drinking water purpose complete all as specified and as directed. |
| 47 | S&F flat submersible cable 3 core 1100 volt grade multi stranded copper conductor PVC insulated, water proof, ISI marked of size 6 sqmm for connecting from starter to bore well submersible pump sets complete all as specified and directed. |
| 48 | Supply and fixing bail plug of 150 mm internal dia threadedof minimum thickness 6 mm and 3 mtr long made up of mild steel and continuous welded by electric arc welding at both ends complete all as specified and directed. |
| 49 | Supply and fixing GI steel rope flexible 8 mm dia with GI clamps, nuts, bolts, washer etc for fixing of submersible pump set complete all as specified and directed. |
| 50 | M&L for uPVC Taper reducer of 250 x 150 mm with and including socket threaded complete all as specified and as directed. |
| 51 | S&F mild steel clamp of required length bend to shape made out of 12 mm thick MS plate fabricated to shape suitable for 80 mm dia MS column pipe , including drilling holes, two coats of synthetic enamel paint over a coat of red oxide and nuts, bolts, washers etc complete all as specified and directed. |
| 52 | M&L for fabricating of MS nipple 0.6 Mtr long 80 mm dia threaded both side externally including painting with anti-corrosive paint suitable for drinking water purpose. Flanged one end with heavy duty flange drilled four holes and provision of groove for cable entrance system complete all as specified and as directed. |
| 53 | M&L for Water Meter Cast Iron body both end flange ISI marked suitable for fixing on 150mm diapipe line including nut, bolt, washer and rubber gasket required for joint complete all as specified and directed. |
| 54 | Supply only CHLORINE TEST KIT with coloured sample & test-tubes complete with all testing fitments and OT solution in Rexene finish box complete all as specified and directed. |
| 55 | Supply only PH test kit with coloured sample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) & test-tubes with necessary fitments and 100 ml testing solution in rexene finish wooden box complete all as specified and directed. |
| 56 | Supply only IRON Test Kit & test-tubes with necessary fitments and testing solution in rexene finish box complete all as specified and directed. |
| 57 | Supply andinstallation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 250 mm bore well water lubricated against minimum total head 75 meter and discharge min 525 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. Note :-(i)The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. |
| 58 | Materials and labour for Earthingcompletewith Copper earth Plateelectrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with 20x3 mm copper stripby means of nuts, bolts, check nuts and washers made of galvanised iron and earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work, excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including test point andtesting on complete all as specified and directed. Note:- The quoted rate of above item includes supply and fixing of Earth identification plate as directed and necessary weather coat paint on exposed part of earth pit complete all as directed. |
| 59 | Design, supply, install, testing and commissioning Iron Removal/water treatment Plant of capacity 45 Cum/Hr (10000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel paint over a coat of red oxide primer comprising of the followings complete all as specified and directed.(a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. The shell thickness shall be of 8 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - minimum 900MM and Height on Straight - minimum 750MM. (Necessary Civil work, painting foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set |
| 60 | Srl Item No. 59.00 Contd...(b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand, activated sand, gravels etc as per OEM design. The shell thickness shall be of 8mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Food grade (Non toxic) Epoxy paint from inside and outside two coat of synthetic enamel paint of approved paint over a coat of red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - minimum 2000mm and Height on Straight - minimum 1875mm. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set(c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set |
| 61 | Srl Item No. 59.00 Contd...(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 SetNote :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(iii) Contractor has to carry out necessary raw water testing and design the plant accordingly to obtain portable water . Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (iv)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate.(v) Price of media for oxidation chamber and multigrade filter deemed to be inclusive of the quoted rate of the respective item.(vi) Suitable Demo by OEM rep be imparted to departmental staff for operation and price for the same deemed to be included in the quoted rate |
| 62 | Supply, install testing and commissioning of Altoch (Chlorine) Dosing Systemconsisting offollowing complete all as specified and directed.(a) Receptacle for power-free automatic water sanitizer / conditioning treatment station with proportional dosing arrangement with following attachments:(i)Water Inlet Regulator(ii) Overflow Vent(iii) Water Outlet Regulator (for standalone gravity flow)(iv) Water Outlet Regulator (for offline automated gravity flow)(v)Drain valve(vi) Fluid Level controller(vii) Sludge Level Guage(viii) Station Base Assembly with Station Base Buffer(ix)Station Hood Assembly with multi-cavity arrangement (13)(x)Station Holding AssemblyMaterial of construction: Non-metallic thermoplastic, Maximum Temperature: 45°C, Capacity: 100 litres,Shape: Cylindrical(b) Custom cover for power-free automatic water sanitiser / conditioning |
| 63 | Srl Item No. 62.00 Contd...treatment station with proportional dosing arrangement with following attachments:(i)Refill Cavity Lids (13)(ii) In-built Level Switch & Processor(iii) ½ inch Processor Outlet & Processor Inlet connections(iv)Flexible Connecting DuctMaterial of construction: Non-metallic, Maximum Temperature: 45°C,Shape: Circular(c) Additional Fittings:(i)6 Mtr Suction Tubing(ii)PVC Ball Valve(iii) Plastic check valve(iv) Hose nippleNote :- M&L Necessary connections with pump distribution line shalldeemed to be included in the quoted rate. |
| 64 | Supply and dozing Chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation through recommended dosing system. Replacement indication: visual & weight variationWater contact orifice design: Sealed when dry, exposed upon immersion.Operation type: Non contact, non inhalatory.Cylinder dia: 2.5 inches ± 0.5 inchesCylinder height: Minimum 10.0 inches ± 0.5 inchescomplete all as specified and directed. |
| 65 | Supply, jointing, testing and laying in trenches/floor/wall etcin standard lengths, Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating, ISI markedof the following dia Pipe (nominal diameter), includingpush on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted. |
| 66 | (a)150 mm dia |
| 67 | (b)80 mm dia |
| 68 | M&L for DI fittings ISI marked of size 80 - 200 mm bore suitable forDI pipes class K-9, PN 10, as per IS: 9523 / 2000 with inside cement mortar lining andoutside Zinc coating with finishing layer of Black Bitumen, such as bends (any type radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified and directed. |
| 69 | Supply, install, testing & commissioning of Air release valve, Cast iron, double air outlet, flanged ends,conforming to IS- 14845, 150 mm bore connected to the main line including all jointing materials as required complete all as specified and as directed. |
| 70 | Construction of brick masonry valve pit of size 1200mm x 1200mm x 1200mm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100 mm thick P.C.C. 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level providing valve pit 40 x 40 x 6mm angle iron frame all-round the fixed point by means of 4Nos holdfast made out of flat iron 40 x 6mm x 150 mm long bent to shape embedded using 150 mm long bolt with anchor plateembedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stoned aggregate) of size 230 x 200 x 100mm including provision of hinges welded with angle iron frame and MS cover 3mm thick welded to angle 40 x 40 x 6 mm, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65mm diapad lock and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in any type of soil complete all as specified and directed. |
| 71 | Construction of brick masonry valve pit of size 900mm x 900mm x 900mm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100 mm thick P.C.C. 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level providing valve pit 40 x 40 x 6mm angle iron frame all-round the fixed point by means of 4Nos holdfast made out of flat iron 40 x 6mm x 150 mm long bent to shape embedded using 150 mm long bolt with anchor plate in PCC block (1:2:4) type B-1 (using 20mm graded crushed stoned aggregate) of size 230 x 200 x 100mm including provision of hinges welded with angle iron frame and MS cover 3mm thick welded to angle 40 x 40 x 6 mm, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65mm diapad lock and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in any type of soil complete all as specified and directed. |
| 72 | Construction of brick masonry valve pit of size 600mm x 600mm x 600mm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100 mm thick P.C.C. 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level providing valve pit 40 x 40 x 6mm angle iron frame all-round the fixed point by means of 4Nos holdfast made out of flat iron 40 x 6mm x 150 mm long bent to shape embedded using 150 mm long bolt with anchor plate in PCC block (1:2:4) type B-1 (using 20mm graded crushed stoned aggregate) of size 230 x 200 x 100mm including provision of hinges welded with angle iron frame and MS cover 3mm thick welded to angle 40 x 40 x 6 mm, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65mm diapad lock and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in any type of soil complete all as specified and directed. |
| 73 | Supply, install, testing and commissioning of indoor wall mounting type cubical typeLT Control Board, factory fabricated CPRI type tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50 x 50 x 6 mm angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes complete all as specified and as directed with & including the following accessories :- (LT Panel for Bore Well) |
| 74 | Srl Item No. 73.00 Contd...BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos tinned copper 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \"F\" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit with suitable cable gland shall be provided in the bottom for both incomming & out-going cables.INCOMING (a) MCCB 4P (Ics = 100% Icu) with adjustable thermal magnetic release, having breaking capaity 16 KA of rating 40 A - 01 No. OUTGOING/INSTRUMENTATION SYSTEM :(a)MCB, TP, 40 Amp rating, \"C\" curve having breaking capaity 16 KA- 03 Nos (01 x Spare) (b)MCB, SPN, 10 Amp rating,having breaking capaity 10 KA- 01 No.(c)Fully Automatic Panel mounted open execution star-delta starter suitable for 10 HP induction motor, 415 volts, including overload relay, auto timer & single phase preventer etc complete -02 Nos(One Spare)(d) MCB SPN 20 Amp - 02 Nos |
| 75 | Srl Item No.73.00 Contd...(e)Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 02 Nos.(f) Digital Ammeter with inbuilt selector switch and including CT coil, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit,0-100 Amps - 2 Nos.(g) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set(h)APFC System with MD-XL Capacitors of 4 KVAR capacity to improve power factor to 0.99 . A set of Heavy duty capacitor, type MD-XL, 440 Volts with output capacity 4 KVAR, in suitable ste and configeration all possible set of automatic operation to maintain 0.99 Power Factor.Required MCB\"s, TP, \"C\" Series 415 Volts of required numbers and suitable ratings as per the capacity of the capacitors shall be provided with Microprocessor based control suitable for Power Factor Correction and indication of Lagging and Leading Power Factor. Suitable Power Contactor heavy duty shall be provided for Automatic operation of Each Capacitor. Digital Panel Meter for Current, Voltage,Frequency and Power Factor Having built in selector, Accuracy class-1.0 shall be provided. Detuning reactors of suitable size shall be provided to maintain THD less than 7 percent. The reactors shall be suitable to prevent amplification of 3rd and higher order harmonicsNOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer.(ii) Any connected items not mentioned in above technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 76 | M&L Rotational moulded polythylene multi layer (min 5 layers) water storage tank ofcapacity 10000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed. |
| 77 | Supply, installation, testing and commissioning of horizontal monoblock pumping Setwith suitable capacity energy efficient motor,voltage range 350 to 440 volts, AC 3 Phase, IP 55 Protection, Insulation class \"F\", Mechanical sealing, CI motor and Pump body, SS Pump Shaft, Bronze Impellar with operating head 26 mtr and having capacity to discharge water 8 to 10 Ltrs per Sec with suction and discharge duly mounted on MS frame including foundation / platform as per OEM specification grouted with MS bolts, nuts of required sizeproperly connected with suction delivery water line including shed of appropriate size to cover the entire pump from all climatic conditions complete all as specified and as directed. |
| 78 | Supply andinstallation, testingDOLmotor starter in SS enclosure including necessary connection as per OEM suitable for electric driven pumpof capacity upto 7.5 HP complete all as specified and directed. |
| 79 | S&F 3 core 1100 volt grade multi stranded copper conductor PVC insulated un armoured cable, water proof, ISI marked of size 2.5 sqmm for connecting from starter to mono block pump sets and steel pole tfor connection or street light fitting from junction complete all as specified and directed. |
| 80 | EXTERNAL ELECTRIFICATIONSupply, installation, testing and commissioning Compact Sub Station (CSS-2 ) complete all as specified comprising of the following equipments :-(A) OUTDOOR ENCLOSURE Outdoor type enclosure having construction of powder coatedsteel sheet of thickness 2mm. The enclosure shall have IP 54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure shall be powder coated as per approved colour. Each compartment will be provided with door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided in each compartment.(B) HT SWITCHGEAR(i) HT 11 kV, 630 Amps, 350 MVA, 21 kA for 3 secs, SF6 insulated Non-extensible Compact Switchgear consisting of01 No fixed manual load break switch incomer 03 Nos fixed manual Vacuam Circuit Breaker as out going with microprocessor based self powered relay in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMT + Inst) protection along with Class 1.0 Metering with interconnection between HT switchgear and transformer with Cable240 sqmm 3 Core aluminium unarmoured XLPE cable - 01 Set(ii) 11 kV single phase indoor resin cast PT of ratio 11 kV/rt 3/110 V/rt3, class 0.5-3, Burden 5VA - 50VA, insulation level 28/75 kV, voltage factor 1.2 const and 1.9 for 30 sec, conforming to IS-3156 - 01 Set. (iii)11 kV single phase indoor resin cast CT ratio 100-50/1-1A as per manufactrurer\"s design, based on designed load, class 0.5, 5P10, Burden as per manufacturer\"s design, insulation level 28/75 KV, as per IS-2705- 01 Set per VCB. |
| 81 | Srl Item No. 80.00 Contd...(C) TRANSFORMER(i) 1000 KVA, 11 kV/433 V, Dyn11, 3 phase, copper wound insulation class \"F\", Natural Air Cooling Cast Resin Dry Type Transformer with off circuit link +5% to -5% @ 2.5 % on HT side of transformer with WTI scanner with Alarm and trip contact and other standard accessories - 01 No.(D) LT PANEL3200 Amps rated copper bus bar for three phase and neutral with PVC sleeves supported on insulators - 04 NosINCOMING :-(i) ACB, 2000 Amps, 50 kA, 4 pole, rated operational voltage 415-690 V,Manual draw out (MDO) type microprocessor release with LSIG protection unit with over current, short circuit and earth fault protection with LCD display with the manual setting nobs & current measurement on screen and battery back up with over temperature protection and indication for protection unit shunt trip, over voltage & under voltage release, over frequency & under frequency, phase reversal, Terminals, dedicated slots for releases,In Built Temperature Protection,Ics=Icu=Icw rated impulse withstand voltage 12 kV - 01 No.OUTGOING :-(i)ACB FP, 1000 Amps rating, MDO type, Ics=100%Icu, 50 kA breaking capacity, adjustable thermal magnetic release - 01 No(ii)MCCB FP, 800 Amps rating, Ics=100%Icu, 50 kA breaking capacity, adjustable thermal magnetic release - 02 Nos. (01 Spare)(iii)MCCB FP, 400 Amps rating, Ics=100%Icu, 36 kA breaking capacity, adjustable thermal magnetic release - 03 Nos.(01 Spare)(iv)MCCB FP, 320 Amps rating, Ics=100%Icu, 36 kA breaking capacity, adjustable thermal magnetic release - 01 No. |
| 82 | Srl Item No. 80.00 Contd... (v)Automatic Power Factor Correction (APFC) Systemwith capacitor heavy duty, type MD-XL , 440 V with output capacity 300 KVAR, capacitor bank shall be 12 Step in steps (3 x 50 + 4 x 25 + 2 x 15 + 1 x 10 + 2 x 5 KVAR)( each set coupled with each portion of LT panel ) and configuration to accommodate all possible set of automatic operation to maintain 0.99 power factor. Capacitor panelcontrolled by an intelligent microprocessor based PF correction relay with MCBs TP, “C” Series, 415 V of required sizes with required numbers and suitable ratings as per the capacity of the capacitors,Power Contactors heavy duty for suitable capacitors shall be provided for automatic operation of each capacitors with ON / OFF indications. Power Factor Capacitors shall confirm to IS 13340,13341,IEC 60831. The capacitors shall be suitable for 3 Phase 440 volts,50 Hz suitable for indoor use up to 55 deg C, fitted with discharge register with standard discharge timing 60 Sec as per IS. The Capacitor bank shall be provided with 7% detuned reactor filter to compensate third harmonics from being generated - 01 Set(vi)Digital Panel Meter for Amp, KWh, PF and other parameter flush mounting of size 96 x 96 mm - 01 No(vii) Digital Ammeter with inbuilt selector switch and CT coilwith suitable ratio, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit- 1 No.(viii) Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 01 No.(ix) LED indicating lamp (set of three) - 01 Set(x) Internal control wiring with 1100 volts grade 1.5sqmm stranded copper cable as per colour coding with suitable size lugs as per requirement |
| 83 | Srl Item No. 80.00 Contd... (E) INTERCONNECTION AND EARTHINGInterconnection between switchgear & transformer using 3 x 240 sqmm, 11 kV (E) XLPE cable with interconnection between transformer & LT switchgear using copper bus bars; Internal earthing connections by using 50 x 6 mm GI strips.(F) FOUNDATION : - Foundation to be carried out as per OEM specification and as directed. (CSS-2)NOTE :-1. Design, Drawingof the CSS showing the dimensions is to be obtained from the OEM / Auth supplier and shall be got approved from the Deptbefore placing final orderto the manufacturer.2. Any item not mentioned in above technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates.3. The cost of necessary test calibration during the complete defect liability period as and when required is deemed to be included in the quoted rates.4.The quoted rate shall be deemed to be inclusive of the factory inspection to be carried out by rep of Accepting Officer before dispatch and Pre-commissioning Inspection by SEI at site. 5. Cost for provision for making the complete CSS for SCADA compatibility be included in quoted rate. |
| 84 | Materials and labour for Earthingcompletewith Copper earth Plateelectrode 600 mm x 600 mm x 3.0 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with 32x6 mm copper stripby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work, excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including test point andtesting on completioncomplete all as specified and directed. |
| 85 | Materials and labour for Earthingcompletewith GI earth Plateelectrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with 32x6 mm GI stripby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work, excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including test point andtesting on completioncomplete all as specified and directed.Note:- The quoted rate of above item includes supply and fixing of earth identification plate including necessary weather coat paint on exposed part of earth pit complete all as directed. |
| 86 | Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.0 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (LTP-8) |
| 87 | Srl Item No. 86.00 Contd... BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos tinned copper 600 A rated (for TPN), duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \"F\" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.INCOMING (i)MCCB FP, 400 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 01 No OUTGOING/INSTRUMENTATION SYSTEM :(i)MCCB FP, 100 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 02 Nos ( 01 No Spare) (ii) MCCB FP, 80 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 04 Nos.(iii) MCCB FP, 63 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 03 Nos ( 01 No Spare) (iv)MCB TPN 10 Amps rating, 10 kA breaking capacity,\"C\" curve, ISI marked - 01 No (v)Analog time switch, Programmed via captive segment.Power supply: 230 V~ 50/60 Hz,3-Position override switch \"ON-AUTO-OFF\" on frontpanel. 40 Amp - 01 No(vi)ML-2 Power Contactor, 415 Volt, 3 Pole, Conforming to IS/IEC 60947-4-1 & IEC 60947-4-1, Standard Coil Voltage 240V, rating 20 Amps - 01 No |
| 88 | Srl Item No. 86.00 Contd... (vii)Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 01 No.(viii) Digital Ammeter with inbuilt selector switch and CT coilwith suitable ratio, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit for0- 400 Amps - 1 No.(ix) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.NOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be get approved from the Dept before placing final order to the manufacturer.(ii) Any connected items not mentioned in the above specifications but technically required for efficient working is deemed to be included in the quoted rates.(iii) Rate quoted is deemed to be included the cost of necessary foundation, earthwork, LT danger notice board. |
| 89 | M&L for cable route marker made up of RCC block (1:3:6) type. C-1 usingappropriate size TMT bar and 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( MES HT cable 11/33 KV orLT cable 1100 Volts) on route marker including necessary excavation and earthwork complete all as specified and as directed. NOTE : (i) The spacing between two consecutive cable route indicators shall not be more than 50meters & also shall be provided at each & every bend or corner. (ii)PCC for foundation will be measured and paid separately |
| 90 | M&L for outdoor LT panel of size 450x300x200mm made up of 3 mm thick CRCA sheet powder coated CPRI approved with front side openable hinge mounted door with rubber gasket complete mounted on frame with 4 legs made of 45x45mm angle iron with each leg 1 mtr height including necessary earth work, painting, LT danger notice board and MCCB 63A, 4 pole, 25KA - 01 No all as specified and as desired.(For bore well connection from existing perimeter SS)Note : PCC for foundation will be measured and paid separately |
| 91 | Materials and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine etc. including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed. |
| 92 | STREET/SECURITY LIGHTSupply and fixing 8 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 20 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length as per OEM recommendationSingle type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding complete all as specified and directed. |
| 93 | Supply, install, testing and commissioning of LED basedall in one Solar street light system, on and including pole(MNRE specification) incl LED street light system of 1 x 36 watt/ nearest higher available rating, system lumen not less than 3150 lm, capable of working on DC 12 volts power from battery unit, being charged by the solar photovoltaic array panel through charge controller, including suitable luminarie fixing arrangement and foundation all as per manufacturer recommendation complete all as specified and directed.. The details of different items included in the rate quoted are as under :- |
| 94 | Srl Item No. 93.00 Contd... (a) Luminaire :- IP 65, full body, aluminium pressure die cast housing, LED type 1 x 36 W/ nearest higher available rating all as specified and directed suitable for battery system of 12 Volts DC(b) Maintenance free Lithium Ion Battery 1 No of minimum 12V, 100 AH @ C10 rating (12 Volt system) all as specified and directed.(c) Mono crystalline solar photovoltaic module array panel conforming to all relevant IEC/IS standards of best quality. Solar Panel shall bemin 125 Wp(12 Volt system). The panel shall be suitably connected to battery through charge controller for its charging all as specified and directed.(d) Solar Charge controller MPPT based conforming to relevant IEC/IS standards shall be provided to charge the battery from solar photo voltaic array panel all as specified and directed including suitable protection mechanism.(f) Steel Octogonal pole, hot dip galvanised, 3 metre height, conforming to relevant IS/IEC standards. The earth work, PCC foundation etc forpole shall be as per manufacturer guidelines and quoted rate is deemed to be included the same.(g) All the electrical fittings, batteries, solar photo voltaic array panel shall be fixed on apole of suitable height from ground level all as specified and directedNote :- All the items like solar photo voltaic array panel, luminaire, solar charge controller, batteries etc shall confrom to relevant IEC/IS standards. |
| 95 | PRIME COST SUM.The prime cost is to used as directed by the Accepting Officer vide condition 1(v) and 5 of IAFW-2249.(a)Provide a prime cost of Rs. 2,43,000.00 for Provision of 01 No. Coocking Platform as specified and approved by GE.(b) The contractor is to quote the amount in the money column i.e. in Col \"M\" adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum.Notes :-(i)Item(s) covered under Prime Cost Sum shall be ordered as per condition 5 of IAFW-2249.(ii) Contractor shall quote amount adding over the amount of prime cost sum to cover his overhead and profit.(iii) Percentage (plus/minus) subject to maximum of 15% (on plus side) shall be taken as the PC sum percentage. |
| 96 | PRIME COST SUM.The prime cost is to used as directed by the Accepting Officer vide condition 1(v) and 5 of IAFW-2249.(a)Provide a prime cost of Rs.1,03,600.00 for Provision of 02 Nos. Working Platform as specified and approved by GE.(b) The contractor is to quote the amount in the money column i.e. in Col \"M\" adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum.Notes :-(i)Item(s) covered under Prime Cost Sum shall be ordered as per condition 5 of IAFW-2249.(ii) Contractor shall quote amount adding over the amount of prime cost sum to cover his overhead and profit.(iii) Percentage (plus/minus) subject to maximum of 15% (on plus side) shall be taken as the PC sum percentage. |
| 97 | PRIME COST SUM.The prime cost is to used as directed by the Accepting Officer vide condition 1(v) and 5 of IAFW-2249.(a)Provide a prime cost of Rs. 56,000.00 for Provision of 01 No. Serving Platform as specified and approved by GE.(b) The contractor is to quote the amount in the money column i.e. in Col \"M\" adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum.Notes :-(i)Item(s) covered under Prime Cost Sum shall be ordered as per condition 5 of IAFW-2249.(ii) Contractor shall quote amount adding over the amount of prime cost sum to cover his overhead and profit.(iii) Percentage (plus/minus) subject to maximum of 15% (on plus side) shall be taken as the PC sum percentage. |
| 98 | Note:- Schedule of cedit (Sch \"A\" Part- XIII) amount of Rs 3,10,500.00 shall be deducted from the total quoted amount of BOQ. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail