| 1 | SCHEDULE A BOQ |
| 2 | Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan & getting out in hard/dense soil complete all as specified and as directed. |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed. |
| 4 | Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and as directed. |
| 5 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and as directed. |
| 6 | Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and as directed. |
| 7 | M&L 100mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate complete as floor base all as specified and as directed. |
| 8 | M&L 50mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate Finished even & smooth without using extra cement complete all as specified and as directed. |
| 9 | M&L 28 mm wide glass dividing strips, 3 mm thickcomplete all as specified and as directed. |
| 10 | M&L for Brick work with fly ash old size bricks, straight or curved on plan not exc 6m mean radius built in cement mortar 1:6 complete all as specified. |
| 11 | M&L Brickwork with fly ash old size bricks bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and as directed. |
| 12 | M&L Plain Cement Concrete 1:2:4, Type B1 (using 20 mm graded granite stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbscomplete all as specified and as directed. |
| 13 | M&L for rendering 15mm thick in two layers on fair faces ofbrick or concrete surfaces in cement mortar 1:4 finished even & fair complete all as specified and directed. |
| 14 | M&L Preparing new surfaces ofplastered or unplasteredwall and applying two coats of cement based paint over one coat of alkali resistant primer complete wash complete ll as specified and directed. |
| 15 | Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in hard/dense soil complete all as specified and as directed. |
| 16 | Removing excavated soil exc. 1.50 Km and n exc 5.0 Km depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 17 | M&L forPCC 1:2:4type B1using20 mm graded stoneaggregateas in pillars, post holes and mass concrete complete all as specifiedand directed. |
| 18 | S&F steel work in tubular trusses/purlines/columns incl special shaped washer etc complete using ERW butt welded tubes conforming to IS 1161-1979 complete all as specified and as directed. |
| 19 | M&L for painting two coats of synthetic enamel paint over one coat of red oxide primer including preparation of steel surfaces surfaces exc. 10 cm width or girth complete complete all as specified and as directed. |
| 20 | M&L for MS plates (Plain or chequrred , channels, square cut or notchedordinary and with reivited bolted or welded attachment Fe-410-W (Gde E-250 quality) complete all as specified and as directed. |
| 21 | S& F pre painted galvalume aluminiumzinc coating GI based corrugated steel sheet 0.50 mm of coloured having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws, as per manufacturer instruction and all as specied and directed. |
| 22 | S& F pre painted galvalume aluminiumzinc coating GI based plain steel sheet 0.50 mm ofcoloured having tensile strength of 550 Mpa as in ridges,roof covering/clading to wall, fixed with self tapping screws, as per manufacturer instruction and all as specied and directed. |
| 23 | M&L Precast RCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs, chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed. |
| 24 | M&L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 25 | Providing and layingfactory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 26 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed offine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed. |
| 27 | Disconnecting existing tanks of capacity exc 500ltr and n exc 1000ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed |
| 28 | Disconnecting existing tanks of capacity exc 1000ltr and n exc 2000ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed |
| 29 | S&F in repair1000 litres rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) incl connecting up pipes etc complete all as specified and as directed |
| 30 | S&F PVC (SWR) pipes 110mm dia single socketed,inanylength with rubber ring joints, fixed to wall complete all as specified and as directed |
| 31 | S&F 110mm dia PVC (SWR)bends any radius complete all as specified and as directed |
| 32 | Taking down damaged PVC (SWR) pipes 110mm dia single socketed,inanylength with rubber ring joints, fixed in wall and bends complete all as specified and as directed |
| 33 | S&F 3-layer25 mm PP-R poly propyelene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls and in floors etc complete all as specified and as directed |
| 34 | Taking up or down steel tubing/PP-R pipe of 20mm dia and connections, including cleaning for refixing or removal to store complete all as specified and as directed |
| 35 | S&F in repairs 25mm outer dia of pipe PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed |
| 36 | S&F in repair Ball brass valves for 25mm bore dia of pipe, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed omplete all as specified and as directed. |
| 37 | M&L for Water proofing treatment of roofs as per details given below after cleaning the surface with water and using wire brush including removing debris to outside the MoD land complete all as specified and as directed. |
| 38 | Surface preparation: Thorough cleaning work, removal of loose screed, repairing the damaged tile portions and filling any minor potholes with polymer modified mortar using Fosroc Nitobond SBR or equivalent mixed with cement and quartz sand in the ratio of 2.5 litres per bag of cement. The vegetation growth around the drain pipe and other locations shall be completely removed to the roots with the aid of solvents or acids. All the cracks shall be provided with cementitious injection grouting using Cebex 100 and surface cracks sealed with Fosroc Nitobond SBR or equivalent admixed cementitious mortar. |
| 39 | Coving: Providing and laying coving at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with Nitobond SBR of Fosroc or equivalent at dosage of 2 Ltrs per 50kg cement as per manufacturer\"s specification. |
| 40 | Waterproof Coating: Providing and applying two coats of Brushbond Roofguard Premium, single component Acrylic based modified Polyurethane elastomeric Solar Reflective cum waterproofing coating at 0.5mm thickness over the primer layer of Nitoproof WB of Fosroc or equivalent mixed with water in ratio 1:2 and applied at coverage of 8 - 10 sqm / litre (diluted with water) after thorough surface preparation and allowed to dry.The single component coating shall be applied in 2 coats using roller or brush or aqueegee or airless spray at wet film thickness of 0.5mm per coat at coverage of 0.5 litre / sqm over the designated area. Theproduct shall have a solid content of 50%, Tensile strength >2Mpa (ASTM D412), Elongation >250% (ASTM D412), Shore A Hardness : 75 (ASTM D2240), Tear Strength : 13 N/mm (ASTM D624), Adhesion to substrate : 2 Mpa concrete failure (ASTM D4541), Crack bridging : 2mm ( ASTM C 836), UV resistance 1000 hours : Pass ( ASTM D4587) , Service Temperature : -10°C to +60°C ,SRI- 100% .The coating shall be extended to the parapet wall total height as per manufacturer\"s specification.In case of severe dampness an additional coat of damp proof materials to be applied. |
| 41 | Note for Water proofing treatment:(i) The work shall be carried out through authorized and qualified applicators of the following manufacturer\"s only. MOU to be submitted before commencement of work. Make:M/s Fosroc or equivalent in M/s Pidilite / M/s Dr Fixit / M/s Asian paints / M/s Sika chemical |
| 42 | (i) A performance guarantee certificate for 10 years shall be submitted by the contractor to the GE on completion of work as specified. |
| 43 | (ii) The unit rate quoted is deemed to include taking down cables, wires, earthing strips etc found on roof and refix the same at the original position after complete treatment of roofs. |
| 44 | (iii) The unit rate quoted shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto any height from natural ground level. |
| 45 | (iv) Necessary safety arrangement like safety belts, ropes, helmets, netting etc which are required for safety of working labour at height exc 3m to be provided by the contractor and the rate for this provision is deemed to be inclusive in the quoted rate. |
| 46 | M&L for providing PCC 1:2:4 type B0 using 12.5 mm graded stone aggregates as in roof or in any positions to bring upto the slope of average thickness of 40mm complete all as specified and as directed. |