| Sl. No. | Item Description |
| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | PHASE I |
| 3 | Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I(A) |
| 4 | Schedule ‘A’ Part-I(B)(MINOR BRIDGE WORK)Construction of bridge 35.00 m span with PSC girder including retaining walls, abutments with pile caps, eartnfilling and excavations, approach paths etc complete all as shown on drawings.Note:(i) Boring of pile and cast-in-situ of pile including its concrete and reinforcement shall be measured and paid separately under relevant Schedule.(ii) Cost of pile cap including RCC, reinforcement and form work & its earthwork are included in the quoted amount of bridge. |
| 5 | Lumpsum price workedout by the tenderer for CAST-IN-SITU PILE as listed in Schedule ‘A’ Part-I(C) |
| 6 | Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, DEVELOPMENTS AND EARTH WORKS as listed in Schedule \"A\" Part-II. |
| 7 | Lumpsum price worked out by the bidder/ tenderer forINTERNAL WATER SUPPLYas listed in Schedule \"A\" Part-III. |
| 8 | Lumpsum price worked out by the bidder/ tenderer forROAD, PATH AND CULVERT as listed in Schedule \"A\" Part-IV. |
| 9 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule \"A\" Part-V. |
| 10 | Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL AND GATE as listed in Schedule \"A\" Part-VI. |
| 11 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule \"A\" Part-VII. |
| 12 | Lumpsum price worked out by the bidder/ tenderer for RETAINING WALL as listed in Schedule \"A\" Part-VIII. |
| 13 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule \"A\" Part-IX. |
| 14 | Lumpsum price worked out by the bidder/ tenderer for AC AND REFRIGERATION as listed in Schedule \"A\" Part-X. |
| 15 | Lumpsum price worked out by the bidder/ tenderer for LIFT as listed in Schedule \"A\" Part-XI. |
| 16 | Lumpsum price worked out by the bidder/ tenderer for TELEPHONE AND INTERCOM as listed in Schedule \"A\" Part-XII. |
| 17 | Lumpsum price worked out by the bidder/ tenderer for ENGAGEMENT LIGHT as listed in Schedule \"A\" Part-XIII. |
| 18 | Lumpsum price worked out by the bidder/ tenderer for DG SET as listed in Schedule \"A\" Part-XIV. |
| 19 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-XV. |
| 20 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule \"A\" Part-XVI. |
| 21 | Lumpsum price worked out by the bidder/ tenderer for FIRE ALARM SYSTEM as listed in Schedule \"A\" Part-XIV. |
| 22 | Lumpsum price worked out by the bidder/ tenderer for FIRE FIGHTING SYSTEM as listed in Schedule \"A\" Part-XVIII. |
| 23 | Lumpsum price worked out by the bidder/ tenderer for DEMOLITION AND DISMANTLING as listed in Schedule \"A\" Part-XIX. |
| 24 | Sch \"A\" Sec-XX (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 25 | Supply, laying, jointing and testing GI tubing of 65 mm bore, medium grade with and including all medium grade galvanished iron fitting and fixing ISI Marked accessoiries such as Tees, elbows, bend, sockets unions, plugs and sockets, short pieces connector and back nuts, deminishing pieces, cap plugs etc fixed to walls and ceilings or laid in floors complete all as specified and directed |
| 26 | S&F two way bib cock with wall flange quarter turn (Low-Flow) 16 mm dia complete all as specified and directed. |
| 27 | S&F 15 mm bore push cock for urinal for iron pipe complete all as specified and directed. |
| 28 | S&F Gun-metal, globe or gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe of 65 mm bore complete all as specified and directed |
| 29 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hookincluding connections and fixed in position with 1 mtr, flexible pipe 15 mm bore (braided tube) & hook, complete all as specified and directed. |
| 30 | Felling of 151 Nos of tree exc 30 cm girth including cutting of trunk and branches, stacking of all material and taking out from MoD land.The details of trees are as per BOO and pricing done by Divisional Forest Officer as below :No of Trees = 151 NosRoyalty Payable = Rs.36731.00Amount for timber and firewood = Rs. 352764.00Total amount = Rs. 389495.00 |
| 31 | S&F 2 mm thick translucent corrugated UV stabilized fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated \"J\" or \"L\" hooks, bolts & nuts of 8 mm dia complete all as specified and directed. |
| 32 | Supply and installation of 17,500 liter capacity LLDPE (Linear Low-Desity Polythlene) septic tank with dimensions of 5.75 meters in length, 2.0 meters in diameter and 2.20 meters in height.The tank weighs 750 Kg and includes 3 manholes for access and maintenance and it consists with 160 mm diameter inlet and outlet connections complete all as specified and directed.Note: The cost of transportaion, positioning, connection to the sewer network and back filling are included in the quoted rate of this item. |
| 33 | S&F SFRC Manhole cover complete all as specified and directed. |
| 34 | S&F 150 mm wide PVC Water Bar complete all as specified and directed |
| 35 | S&F Modular type 3 pin 20 A Socket with one No. of MCB single pole conforming to IS 1293 : 2005 as specified in IS 732 : 2019 complete all as specified directed. (for AC & Geyser Point) |
| 36 | S & F of LED low bay light fitting of 40 Watt system wattage, high-quality group control enabled intgrated LED high bay light with a minimum system lumen of min 5600 lm with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, and CR≥70. The luminaire should be designed for operations under diverse environment from - 10ºC to 50ºC. The luminaire should be beam angle of light source 30º/60º/90º as per requirement. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminium, to withstand extreme environments. The spigot shall be part of \"Single Piece Pressure Die-cast housing\" & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. The luminaire LED shall have declared Lifetime of 50 Khrs (L70B5O @ Ta 45ºC). The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP65 & impact resistance shall be IK08. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 6KA SPD duly bolted in the Luminaire. The LED used in the luminaire shall be SMD type only & shall be from either Lumineds, Osram, Nichia, Cree & APT Electronics make or equivalent. The Driver should be asphalt potted & should be a BIS approved driver. |
| 37 | Continued Serial item No. 20.012The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load, Current ripple <10%. The driver should be capable of withstand voltage stress of 440V for 8 hrs., should have an auto shutdown @ 325V (±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it\"s SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with sample approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed. |
| 38 | Supply, Installation, testing & commissioning of LED Engagement light fitting (Red & Green),220 V, luminaire made of CRCA housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed system lumens at a system efficacy of at-least 100 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum2 KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant. The luminaire driver shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The Contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. Contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed. |
| 39 | S&F Surge Protection Device (SPD) single phase and neutral, T2 -limb, Imax 20 KA per polefixed in distribution board and making connections complete all as specified and directed |
| 40 | S&F Surge Protection Device (SPD) Three phase and neutral, T2 -limb, Imax 20 KA per pole fixed in distribution board and making connections complete all as specified and directed |
| 41 | S&F Modular Telephone socket RJ 11 suitable for housing modular frame plate complete all as specifiedand directed |
| 42 | S&F modular type TV socket. RJ46, 1 module complete all as specified and directed. |
| 43 | Supply, Installation, Testing and Commissioning of White LED strip light IP68,CB and CE certified sealed with anti-UV polyurethanealong with accessories such as driver, mounting clips, connectors, etc. as required forstraight or curved surfaces and recessed applications with housing of Extruded silicone, wattage not exceeding 65W/ 5 Mwith lumen output of not less than 5000/ 5 M . Luminaire has a choice of beam angles of 120° degree. Fixture should run on input voltage of 24VDC. Lifetime should be at least 30000 burning hours at L50 at 25 degree centigrade with total IP66 protection should be provided. Controlled through DMX/Ethernet protocol complete all as specified and directedNote : [i] Luminaire uminaire should be BIS certified and [ii] CRS No. for both luminaire and driver along with LM79report from NABL accrediated LAB should be submitted. |
| 44 | Supply, Installation, testing and commissioning of exterior rated LED linear luminaire of 1000mm with dedicatedoptics for architectural lighting. Beam angles option of A11: 20x30° Beam Angle degBeam Angle . Wattage of 15W 24V DC poweredand should be able to produce light by LED Channels of 3000Kand DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 985 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L70 @ 50000 hours at 35 degree complete all as specified and directedNotes : [i] Maximum weight of the luminaire should be 2.5kgs. [ii] Luminaire should be BIS certified. |
| 45 | Supply, Installation, testing and commissioning of Extruded aluminum with die-cast aluminum end caps Electrostatically applied polyester powder coating Dark Grey (RAL7012) modular, rectangular shaped exterior rated LED floodlighting luminaire with dedicated optics for architectural lighting. Beam angles of3°, 10°, 30°, 45°, 60°. Wattage of 300W and should be able to produce light by LED Channels RGBNW (4000K)and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 15000 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L50 @ 50000 hours at 35 degree complete all as specified and directedNote : [i] Maximum weight of the luminaire should be 16kgs. [ii] Luminaire should be BIS certified. |
| 46 | Supply, Installation, testing and commissioning of exterior rated LED linear luminaire of 1000mm with dedicated optics for architectural lighting. Beam angles option of 16x 35 deg 25x40°, 30°, 40°, 50°. Wattage of 36W and should be able to produce light by LED Channels of RGBNW (4000K, neutral white) and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 1200 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L70 @ 50000 hours at 35 degree complete all as specified and directedNote :[i] Maximum weight of the luminaire should be 4.0 kgs. [ii] Luminaire should be BIS certified. |
| 47 | Supply, Installation, testing and commissioning of Extruded aluminum with die-cast aluminum end caps Electrostatically applied polyester powder coating Dark Grey (RAL7012) modular, rectangular shaped exterior rated LED floodlighting luminaire with dedicated optics for architectural lighting. Beam angles of10°,30,°45°, 60°. Wattage of 150W and should be able to produce light by LED Channels RGBNW (4000K)and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 7500 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L50 @ 50000 hours at 35 degree complete all as specified and directedNote :[i] Maximum weight of the luminaire should be 7.5 kgs. [ii] Luminaire should be BIS certified. |
| 48 | Supply, Installation, testing and commissioning of Extruded aluminum with die-cast aluminum end caps Electrostatically applied polyester powder coating Dark Grey (RAL7012) modular, rectangular shaped exterior rated LED floodlighting luminaire with dedicated optics for architectural lighting. Beam angles of3 DegWattage of 100W and should be able to produce light by LED Channels RGBNW (4000K)and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 7500 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L50 @ 50000 hours at 35 degree complete all as specified and directedNote :[i] Maximum weight of the luminaire should be 7.5 kgs. [ii] Luminaire should be BIS certified. |
| 49 | Supply, Installation, Testing and Commissioning of intelligent and compact master DMX controller that is developed for small and medium sized applications. It can control up to 8 DMX512 universes, playback scenes and animations stored in its SD card and it can be used for offline scenes scheduling, setting brightness, white balance and playback speed adjustments complete all as specified and directed |
| 50 | Supply, Installation, Testing and Commissioning of ethernet switch with all accessories for Façade lighting system complete all as specified and directed |
| 51 | Supply, Installation, Testing and Commissioning of ethernet based Stand-alone wall-mounted controller that triggers up to six shows at the touch of a button that Supports 10/100 Mbps full- or half-duplex from any PoE- or IEEE 802.3af-compliant Ethernet switch. PoE injector required for use with non-IEEE 802.3af-compliant switches; maximum 3W, made up of Medium matte white plastic enclosure; suitable for RJ45 Port, shielded Cat. 5e or better data cable; IP20, operating from -5ºC to 50ºC, 0 – 90%, non-condensing complete all as specified and directed |
| 52 | Supply, installation, testing and commissioning of Surface / Dinrail mountable DMX Spilitter and booster device suppoting bidirectional communication for discovery,addresing and control of DMX enabled light fixtures. Device should be capable oftaking incoming DMX/RDM signal and splits the signal into six separate output channels.The output terminals should beelectronically isolated from the input & RDM-through port and should share a common ground reference. All six output ports should have an independent output driver to boost the DMX/RDM signal.Maximum Power Consumption of device should be 4.5W complete all as specified and directed |
| 53 | Supply, Installation, Testing and Commissioning of Programming and commissioning of Facade lighting system with allnecessary hardware and softwares complete as per design approved by Accepting Officer complete all as specified and directed |
| 54 | Supply, Installation, Testing and Commissioning of JV BOXVoltage Stabilizer DMX Power Cablewith all accessories as required for complete operation of Façade lighting system complete all as specified and directed |
| 55 | VRF OUTDOOR UNITSupply, installation, testing and commissioning of following VRF / VRV outdoor units, having R410A / R407C refrigerant, multiple Nos. of inverter, digital scroll compressors, air cooled condenser fan with motor, microprocessor control panel, starter controls for all scroll compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes for interconnecting various capacity modules, charging port and all other required accessories, & hardware, first charge of refrigerant and all other required accessories, hardware like T joints etc., all enclosed in an enclosure with weather resistant powder coating paint for withstanding all ambient conditions for continuous outdoor operation, suitable to operate on 3-Phase, 380-415 V, 50 Hz AC power supply complete all as specified and directedNOTES: [i] The VRF/ VRV system shall be provided with mounting base and antivibration pad(s). All the accessories, hardware, software, consumables etc. whether specifically mentioned or not but required to put the VRF / VRV System into service up to the satisfaction of the Engineer-in-charge including testing, commissioning as per specifications, site constraints shall be deemed included in the scope of the work.[ii] Nothing extra shall be payable for these systems under any circumstances. All the consumables including first charge of refrigerant (R410A / R407C) and oil for the proposed VRF / VRV system shall be deemed inclusive in the scope of work. The topping of refrigerant and oil shall also be included in the scope of work for arresting leakages if any. The unit shall be lifted using crane / sufficient manpower and installed on suitable pedestal / MS rail / bots & nuts etc, all complete as requirement of site conditions. |
| 56 | (a) VRF / VRV outdoor units of min. 18 HP combined heating + cooling capacity at site conditions |
| 57 | (b) VRF / VRV outdoor units of min. 20 HP combined heating + cooling capacity at site conditions |
| 58 | REFRIGERANT COPPER PIPINGSupply, installation, testing and commissioning of refrigerant copper piping (duly insulated with 19 mm thick closed cell elastomeric nitrile rubber tubular insulation) of hard drawn / soft drawn copper pipe, laid on walls / roof / ceiling well supported at specific intervals with metallic supports and screwed with anchor fasteners and necessary accessories, jointing / brazing etc., including connection between outdoor unit to indoor units as required complete all as specified and directedNOTES: [i] The sizing of refrigerant copper piping shall be confirmed / vetted by the OEM.[ii] All piping inside the ceiling shall be properly supported using necessary clamps and all externals refrigerant lines shall be properly protected using necessary PVC (HDPE) pipes with accessories to suit the site conditions.[iii] The quantity of these items of works shall be measured as per actuals requirements of site conditions. The vendor shall accept the accepted rate as per the actual measured quantities. |
| 59 | (a) 5/8\" (15.9 mm) (Liquid) |
| 60 | (b) 1 1/8\" (28.6 mm) (Gas) |
| 61 | Supply, installation, testing and commissioning of variable refrigerant flow distribution Ref-nets joint (Y-joint) in the gas and liquid lines for outdoor unit complete all as specified and directed |
| 62 | M&L for 25 / 32 / 40 mm dia .PVC drain water pipe including bends, collars & elbow etc,and duly insulated with 9 mm thick tubular insulation of closed cell elastomeric nitrile rubber as required complete all as specified and directed. |
| 63 | M&L for square / rectangular / round neck 525 mm X 525 mm rectangular neck 4-way discharge ceiling supply diffuser having neck velocity ≤ 600 ft/min, throw ≥ 26\" @ 150 ft/min velocity NC ≤ 37 for air flow ≥ 1450 ft3/min ceiling Supply diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed (AIR TERMINAL) |
| 64 | M&L for square / rectangular / round neck 450 mm X 450 mm rectangular neck 4-way discharge ceiling supply diffuser having neck velocity ≤ 600 ft/min, throw ≥ 26\" @ 150 ft/min velocity NC ≤ 37 for air flow ≥ 1450 ft3/min ceiling Supply diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed |
| 65 | M&L for square / rectangular / round neck 375 mm X 375 mm rectangular neck 4-way discharge ceiling supply diffuser having neck velocity ≤ 600 ft/min, throw ≥ 26\" @ 150 ft/min velocity NC ≤ 37 for air flow ≥ 1450 ft3/min ceiling Supply diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed |
| 66 | M & L for square / rectangular / round neck 300 mm X 300 mm rectangular neck 4-way discharge ceiling supply diffuser having neck velocity ≤ 600 ft/min, throw ≥ 26\" @ 150 ft/min velocity NC ≤ 37 for air flow ≥ 1450 ft3/min ceiling Supply diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed |
| 67 | M&L for square neck 525 mm X 525 mm rectangular neck 4-way discharge ceiling return diffuser @ 150 ft/min velocity NC ≤ 25 for air flow ≥ 830 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed |
| 68 | M&L for square neck 450 mm X 450 mm rectangular neck 4-way discharge ceiling return diffuser @ 150 ft/min velocity NC ≤ 25 for air flow ≥ 830 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed |
| 69 | M&L for square neck 375 mm X 375 mm rectangular neck 4-way discharge ceiling return diffuser @ 150 ft/min velocity NC ≤ 25 for air flow ≥ 830 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed |
| 70 | M&L for square neck 300 mm X 300 mm rectangular neck 4-way discharge ceiling return diffuser @ 150 ft/min velocity NC ≤ 25 for air flow ≥ 830 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed |
| 71 | M&L for CBRI certified 16-gauge GI fire damper, at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated crossovers (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555 complete all as specified and directedThe fire dampers shall meet the following criteriaon:[i] Bare fire dampers with 400 mm sleeve[ii] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position[iii] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers[iv] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer. |
| 72 | (a) Motorized, spring return type, combination fire and smoke damper |
| 73 | (b) Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. |
| 74 | Supply, installation, testing and commissioning of high performance airfoil class 1A leakage rated GI volume control damper having galvanised steel hat channel frame reinforced with corner braces, galvanised steel airfoil shaped blades (double skin construction) of 14 gauge thicknes, neoprene blade edge seals, flexible metal compressible jamb seals, stainless steel sleeve, linkage concealed in frame, etc. tested as per AMCA Standard 500-D-98 complete all as specified and directed |
| 75 | S & F of FM approved flexible pre-covered self-extinguishing thermal insulation made of flexible insulation foam based on synthetic rubber with polymeric covering reinforced with polyester scrim, for insulation of air conditioning ductwork both indoor and outdoor conditions to prevent condensation, reduce energy losses, prevent scratches, mechanical damage and frost on pipes, tested for maximum +85 ᵒC & minimum 0 ᵒC service temperature in conformance with EN 14706, EN 14707 & EN 14304; tear strength > 38 kN/m & tensile strength > 1.5 MPa in conformance with DIN ISO 34-1 & DIN EN ISO 1978; thermal conductivity (λ) ≤ 0.035 W/mK @ 0 ᵒC, ≤ 0.037 W/mK @ 24 ᵒC & ≤ 0.039 W/mK @ 40 ᵒC temperature in conformance with EN 12667 & EN ISO 8497; water vapour diffusion (μ) ≥ 7000 in conformance with EN 12086 & EN 13469; water absorption by volume ≤ 0.2% in conformance with ASTM C 1763; Class O with dura fire performance in conformance with BS 476 Part 6: 1989; Class 1 surface spread of flame in conformance with BS 476 Part 7: 1997; HB, V-0 flammability in conformance with UL-94; UV & moisture in conformance with EN ISO 4892-2 method A & B and having zero ozone depletion potential & zero global warming potential, no risk of galvanic corrosion, good UV resistance, good resistance to mechanical impact, etc., in pre-covered self-adhesive sheets with self-seal and other necessary accessories complete all as specified and directed |
| 76 | (a) 19 mm thick thermal insulation (for supply air ducting) |
| 77 | (b) 13 mm thick thermal insulation (for return air ducting) |
| 78 | Supply, install, testing and commissioning of Variable Air Volume (VAV) unit to match duct sizewith pressure independent(AHRI certified)with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals, consisting of BACnet/MSTP communicable DDC controller (fully controllable BTL certified) damper actuator, low pressure velocity transducer and temperature sensor (with digital room thermostat), VAV shall be dynamically calibrated and tested in factory on live test bed as per 500-1000 CFM, each unit shall be supplied with LCD display room thermostatic controller with 10mtr suitable communicable wire complete all as specified and directed. |
| 79 | Supply, install, testing and commissioning of Variable Air Volume (VAV) unit to match duct sizewith pressure independent(AHRI certified)with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals, consisting of BACnet/MSTP communicable DDC controller (fully controllable BTL certified) damper actuator, low pressure velocity transducer and temperature sensor (with digital room thermostat), VAV shall be dynamically calibrated and tested in factory on live test bed as per 1000-1300 CFM, each unit shall be supplied with LCD display room thermostatic controller with 10mtr suitable communicable wire complete all as specified and directed. |
| 80 | Supply, install, testing and commissioning of Variable Air Volume (VAV) unit to match duct sizewith pressure independent(AHRI certified)with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals, consisting of BACnet/MSTP communicable DDC controller (fully controllable BTL certified) damper actuator, low pressure velocity transducer and temperature sensor (with digital room thermostat), VAV shall be dynamically calibrated and tested in factory on live test bed as per 1300-1800 CFM, each unit shall be supplied with LCD display room thermostatic controller with 10mtr suitable communicable wire complete all as specified and directed. |
| 81 | Supply, install, testing and commissioning of Variable Air Volume (VAV) unit to match duct sizewith pressure independent(AHRI certified)with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals, consisting of BACnet/MSTP communicable DDC controller (fully controllable BTL certified) damper actuator, low pressure velocity transducer and temperature sensor (with digital room thermostat), VAV shall be dynamically calibrated and tested in factory on live test bed as per 2000-2600 CFM, each unit shall be supplied with LCD display room thermostatic controller with 10mtr suitable communicable wire complete all as specified and directed. |
| 82 | Supply and installation of refrigerator, electric driven (single phase), capacity 195 Litres, BEE 5 star rated complete all as specified and directed. |
| 83 | Supply, install, testing and commissioning of voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type, designed for input variation between 170V to 250V with stablized output voltage at 230V with accuracy of ±2.5% and of capacity 1.0 kVA complete all as specified and directed. |
| 84 | Supply, install, testing and commissioning of voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type, designed for input variation between 170V to 250V with stablized output voltage at 230V with accuracy of ±2.5% and of capacity 0.50 kVA complete all as specified and directed. |
| 85 | Supply, Install, Testing and commissioning of a remote annunciator / Repeater Panel with supervised wireless link to the FACP, showing Alarm / Supervisory / Fault with zone / device text. Polling interval ≤10s; loss-of-comms trouble ≤60s. Back - lit LCD, LEDSs (Alarm, Supervisory, Fault, Power, Link), internal buzzer (≥75 dB @ 1 m) with silence key as permitted. Power 230 V AC with charger and batteries sized for ≥ 24 h standby + 30 min alarm. Enclosure IP54 for indoor brigade room. Provide mounting hardware, pairing, signal survey, labels, and commissioning records complete all as specified and directed. (to be placed at Fire Station / Guard Room) |
| 86 | S&F Data line Surge Protection Device (SPD) suitable for RS-485, two stage, replaceable Modules, single phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in FACP & Repeater Panel and making connections complete all as specified and directed |
| 87 | Supply, installation, testing and commissioning of FM approved & UL listed Remote power Supply conforming to UL864 & 1481 and NFPA 72 with integral battery charger capable of charging up to 18 Ah batteries to provide regulated and filterred 24 VDC power to notificattion appliance circuits, having power - supervision relay, fully regulated and filtered power output. AC trouble report selectable for immediate 2-hour delay, selectable earth fault detection, etc complete as specified and directed |
| 88 | Supply, installation, testing and commissioning of UL listed (fire fighter\"s) addressable Telephone Jack mounted to a single - gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete as specified and directed |
| 89 | Supply, installation, testing and commissioning of UL listed Fire Fighters Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete as specified and directed |
| 90 | M & L for transparent FR PVC insulated, twin core copper conductor flexible Speaker Cable haivng stranded annealed tinned copper conductor, PVC insulated cores twisted to form pairs, shielded forinterference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 mm² including laying, termination and ferruling complete as specified and directed |
| 91 | S&F6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure COշ gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. ccomplete as specified and directed |
| 92 | S&F4.5 kg light-weight squeeze grip COշ type fire extinguisher, conforming to IS 15683: 2006, with COշ gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed |
| 93 | Supply, Installation Testing & Commissioning of Autimatic fire extinguishers - ceiling mounted clean agent (HFC236fa) capacity of agent 6 Kg, filling tolerance by mass 6-5%, Certification Standard - PED BSU Tested, Dia of Shell - 240mm, Total Height with base (Approx) -341mm, MOC or Shell - Steel CR2 , Test Pressure- 35 Bar, Service Pressure - 10 Bar, Type of operation - Automatic, Type of Pressure Gauge - Magnetic Bourdon tube type, Min Discharge time - 4 to 9 Sec, Operating temp range -30 ºC to +60 ºC complete all as specified and directed. (to be placed at Utility Room & Telephone Exchange) |
| 94 | S&F the following type of Signages made out of 3 mm thick opaque PVC foam board with computer cut. PVC non - reflective self adhesive vinyl painted foarm board, complete with mirror fasteners complete as specified and directed |
| 95 | (a) Signage having size 300 mm X 150 mm reading \"EXIT\" in 12.5 mm block letters in Green and white background, self illuminated properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level.These lights shall emit the maximum light required even during the electricity supply or in Black out period with high energy efficiency manufactured using superior quality Aluminium Extrusion body raw material complete as specified and directed |
| 96 | (b) Signage having size 500 mm X 500 mm, indicating the \"Floor Number\" in bold type and at 75 mm high numerals in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non - reflective self adhesive vinyle painted foam board, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete as specified and directed |
| 97 | (c) Signage having size of 450 MM X 150 MM reading \"FIRE EXTINGUISHER\" in 12.5 mm block letters in White and Red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non - reflective self adhesive vinyle painted foam board, properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete as specified and directed |
| 98 | (d) Signage having size of 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the \"STAIRCASE\" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete as specified and directed |
| 99 | Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type \"Motor Control Center\" (MCC) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. The MCC shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of Aluminimum / Copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i] Circuit Breaker (a) 250 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz, FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload) - 01 No. |
| 100 | Serial item No. 20.062 continued...[ii] Instrumentation & Measurement (a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 No. (b) 250/5A CI. 1.0 C.T. with 15 VA burdon - 01 No[iii] Indication & Annuciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set[C] OUTGOING[i] Circuit Breaker (a) 200 A, 415 V, Ics = 100%, Icu = 25 kA, 50 Hz, 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting,front indication LEDs - 01 No. (b) 32 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz, 3P MCCB, conforming to IEC 60947-2:2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting,front indication LEDs- 01 No. (c) 32 A, 250 V, Ics = 100% Icu = 25 kA, 50 Hz, 1P MCCB, conforming to IEC 60947-2:2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting,front indication LEDs- 02 No.[ii] Motor Starter / Drive (a) Fully automatic digital soft starter suitable for 55 KW drive having adaptive acceleration control, built-in RTD & thermistor inputs, programmable auto start / stop, emergency run operation, fully programmable overload trip, etc. complete with contactors, push button, LED indicators, auto / manual selector switch, current sensing type single phase preventer complete with all accessories and wiring etc. - 01 Nos. (b) Fully automatic DOL starter, suitable for 5.5 KW motor, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.- 01 No. |
| 101 | Serial item No. 20.062 continued...[iii] Controller (a) Control for diesel engine comprising of automatic / manual selector switch & three attempts starting device, timers and relays as required, push buttons, start / stop in manual mode, indicating lamp for high / low lubrication oil pressure, high water temperature and engine on indication, battery charger suitable for 12 V / 24 V DC with boost and trickle selector switch, 0- 30 V DC voltmeter and 0-20 A DC ammeter complete with all standard relays and accessories for automatic operation of the diesel engine - 01 No. [for diesel engine pump] [iv] Instrumentation & Measurement (a) 200/5A CI. 1.0 C.T. with 15 VA burdon - 02 Nos. (b) 50/5A CI. 1.0 C.T. with 5 VA burdon - 02 Nos. (c) 0-200 A Digital ammeter - 02 Nos. (d) 0-50 A Digital ammeter - 02 Nos.[v] Indication & Annunciation (a) LED status indicators (ON, OFF, TRIP) - 06 Set Notes : [i] The busbars shall be of double deck arrangement for rating ≥ 1600A interleaved/non-interleaved design as per OEM. Separation of busbar shall be as*per Form 4b.[ii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250 A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. |
| 102 | Serial item No. 20.062 continued...[iii] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified/not specified above or in the SLD.[iv] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V.[v] The Panel shall be purchased from the original equipment manufacturer (OEM) authorised franchises only.[vi] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical)of the Panel shall be supplied by the OEM.[vii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O./representative.[viii] The Contractor shall intimate the Engineer-in-charge of the routine tests in the OEM factory in presence of a representative nominated by the Engineer-in-Charge before dispatch. |
| 103 | M&L for low smoke zero halogen (LSZH) fire survival control cable with circuit integrity conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire - resistant mica tapes covered by an extruded layer of cross - linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LSZH) compound. single layer of galvanized steel wires and thermoplastic (LSZH) compound sheath,suitable for operating temperature range -40ºC to +90ºC and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete as specified and directed . |
| 104 | (a)2 core, 2.5 mm² (for instrumentation) |
| 105 | (b)3 core, 2.5 mm² (for auto start/stop panel) |
| 106 | (c) 12 core, 2.5 mm² (for diesel engine pump) |
| 107 | M&L for 1.1 kV grade fire survival cable with fire rating FS (950/FWS) conforming to IS17505-1: 2021, and having electrolytic annealed plain / tinned copper (Class 1/2) conductor conforming to IS 8130: 2013, mica tape layer (s) primary insulation, cross linked PE (XLPE) / cross linked HFFR secondary insulation, thermoplastic HFFR inner sheath, glass fibre heat barrier tape, galvanized round wire armour, thermoplastic HFFR (HFS-TP 90) / Cross Linked HFFR (HSF-XL 90) outer sheath including necessary clamping / dressing with cable ties and termination complete as all specified and directed |
| 108 | (a) 3 core, 35 mm² FS (950 / FWS) Cable |
| 109 | (b) 3 core, 4 mm² FS (950 / FWS) Cable |
| 110 | S&Fperforated hot dipped galvanized iron Cable tray of size 300 mm x 50 mm x 1.60 mm having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittings viz, joints, bends, tees, etc, in convenient sections of length complete including cable tray supports and associated accessories complete all as specified and directed. |
| 111 | S&Fperforated hot dipped galvanized iron Cable tray of size 150 mm x 50 mm x 1.60 mm having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittings viz, joints, bends, tees, etc, in convenient sections of length complete including cable tray supports and associated accessories complete all as specified and directed. |
| 112 | S&Fperforated hot dipped galvanized iron Cable tray of size 100 mm x 50 mm x 1.60 mm having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittings viz, joints, bends, tees, etc, in convenient sections of length complete including cable tray supports and associated accessories complete all as specified and directed. |
| 113 | M&L for PN 1.6 rated 200 mm NB polypropylene Vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed |
| 114 | S&F 25 mm dia Ball Valve, designed & manufactured as per IS:9890 (1981) and tested as per BS 6755 Part - I, having floating type three piece design, CS body, SS-304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. |
| 115 | S&F 40 mm dia Ball Valve, designed & manufactured as per IS:9890 (1981) and tested as per BS 6755 Part - I, having floating type three piece design, CS body, SS-304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. |
| 116 | S&F 80 mm dia Ball Valve, designed & manufactured as per IS:9890 (1981) and tested as per BS 6755 Part - I, having floating type three piece design, CS body, SS-304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. |
| 117 | M&L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed |
| 118 | S&Forirface plate made out of 6 mm thick SS 304 with oriface of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm³ complete as specified and directed |
| 119 | Supply, installation, testing and commissioning of automatic Air-vent valve with 20 mm end connections, brass body and cover, plastic float, brass cap etc. suitable for maximum operating pressure of 16bar and maximum operating temperature 100° C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed. |
| 120 | S&F modular telephone / computer socket (RJ-11) with MS box, inner plate and outer plate complete all as specified and directed. |
| 121 | Supply, installation, Testing and commissioning of 8 mm Aluminum Round Conductor as specified in drawing and meets the requirements along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 122 | Supply, installation, Testing and commissioning of Polyamide Roof conductor holderfor fixing of aluminium conductor on parapet with M8 female thread or diameter 7mm, M8 Screw having weather and temperature withstand resistant from -35 to +90 degree Celsius tested, by fixing holder @ 1 meter distance along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 123 | Supply, installation, Testing and commissioning of Polyamide roof cable holder for flat roof conforming DIN:48829 form B1 closed form with bottom, filling weight 1 Kg (frost resisant concrete), sleeve from polyethylene, black. Conductor holder @ 1 meter distance along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 124 | Supply, installation, Testing and commissioning of 3 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305 part-3 Nominal size Ø 10/16 mm aluminium rod, semi hard (E-AlMgSiO5 corresponds to DIN 48801) suitable to withstand high wind load complete with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 125 | Supply, installation, Testing and commissioning of wall fixing cross bar clamp for conductor upto 16mm dia using hot dip galvanised steel complete with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 126 | Supply and fixing alumiium conductor 8mm dia conductor with air termination rod upto 16mm withcomplete accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 127 | Supply, installation, Testing and commissioning of cross universal connector for T cross & parallel connections to route vertical down conductor / mesh formation using hexagonal bolt M10X30 of hot dipped galvanised iron etc as required conforms to the requirements according to IS-IEC 62305 complete as recommended by OEM / Manufacturer all as specified and directed |
| 128 | Supply, installation, Testing and commissioning of cross universal connector for T cross & parallel connections with expansion joint 02 Nos per joint using hexagonal bolt M10X30 of hot dipped galvanised iron etc as required conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305) complete as recommended by OEM / Manufacturer all as specified and directed |
| 129 | Supply, installation, Testing and commissioning of expansion piece with connector for equalising temperature related length changes, in the conductors at every 20 meters length for round conductor 8mm rod along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 130 | Supply, installation, Testing and commissioning of Copper coated round conductor 10mm dia with 100 micron copper coating along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 131 | Supply, installation, Testing and commissioning of Copper coated round conductor 10mm dia with 100 micron copper coating along with necessary accessories for Vertical Column Riseras specified in drawing & Meets the requirements of IS/IEC 62305 complete all as specified and directed. |
| 132 | Supply of clamp for connection with reinforced steel of diameter 16-40mm and with 8mm dia conductorwith all fixing accessoriesas specified in drawing & meets the requirements of OEM standards complete all as specified and directed. |
| 133 | Supply, installation, Testing and commissioning of connectors for T cross and parallel connections with hexagonal bolt M10X30 high-grade hot dip galvanised according to DIN VDE 0185-305 (IS-IEC 62305) along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed |
| 134 | Supply, installation, Testing and commissioning of earth fixed point, made of Stainless Steel grade 316L, connection to earthing systems, air terminals and reinforcement using contact plate of 79 mm diameter, made of rustproof stainless steel (V4A), clamping bolt 10mm diameter, rustproof (V2A), with plastic cover complete all as specified and directed |
| 135 | Supply, installation, Testing and commissioning ofconnector with 8−10 mm with pressure trough with 1 fix contact clamping screw, nut and serrated washer including pre-mounted pressure sump, steel conforms to the requirements according to IEC 62305 complete all as specified and directed. |
| 136 | S&F LED 0.50 Watt green lamp complete all as specified and directed. |
| 137 | S&F LED 0.50 Watt red lamp complete all as specified and directed. |
| 138 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 250 kVA (200 kW),415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Rangapahar (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features conforming to IS 10002: 1981 and latest CPCB-IV+ guidelines and comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 3 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering250 kVA (200 kW) atoutdoor atmospheric conditions at Rangapahar, (Taking all derating factor into consideration),12/24 Volt (as per manufacturer recommendations) electric battery start incl suitable size battery, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . |
| 139 | Serial item No. 20.093 continued....(ii) ALTERNATOR: Brushless AC alternator, conforming to IS 13364:1992, 3 Phase, 415 Volt, 4 wire, rated for output of 200 kW(250 kVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \"H\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi)Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification(vii) AMF Panel: -Microprocessor / Relay based pedestal mounted outdoor use AMF control panel of suitable rating made up of 3.15 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW,frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d)All standard relays, circuitsand protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. |
| 140 | Serial item No. 20.093 continued....(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn.Note: The cost of necessary items required for Remote Monitoring of DG set for collection of following parameters are deemed to be included in the quoted rate of contractor (i) Mechanical & Engine parameters - Real time fule volume in the tank, alert for low fuel levels, engine speed (RPM), oil pressure, coolant temperature, oil & coolant levels, battery status, engine run hours, Exhaust parameters like NOx, CO, PM(ii) Electrical and Alternator parameters - Voltage, current, Power output (kW, kVAr, kVA, kWh/kVAh, frequency, load percentage(iii) Real time operational status (running, stop, idle, failed to start, etc), Alarms & notifications (emergency stop, over voltage, low oil pressure, high temperature and other safety aspects.NOTE:(a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at Site and the cost is deemed to be including in above offer.(c) All expences for Testing of DG Set be included.(d) One set of latest Spare part catalogue with price, exploded view of parts and user\"s manual are deemed to be included in the offer.(e) All civil work including foundation for DG set as per manufacturer\"s drawing/specification, foundation for AMF panel.(f) The rate quoted is deemed to be included for initial filling of radiator colant and lubricating oil upto level.(g) Temperory shed for DG shed is deemed to be included in the quoted rate. |
| 141 | Serial item No. 20.093 continued....Testing : (i) All routine test certificates from the manufacturer in respect of the diesel engine, alternator and the control panel will be made available by the contractor.(ii) The Generating set shall be run for a period of 12 hours, of which at least 6 hours shall be at the rated load and for a period of one hour at 10% over load in above 12 hours running.(iii) All instruments, equipments, materials including DHPP and Engine oil and labour required for testing will be made available by contractor at his own cost and unit rate in Sch \"A\" will be deemed to be included for testing to the entire satisfaction of Engr-in-Charge :-(a) Insulation resistance test on the alternator and control panel. (b) High voltage test as per BS-2613 clause 33 on the alternator when still hot. (c) Efficiency test at rated load and over load.(d) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(e) All test as described above under testing clause shall be carried out in presence of officer nominated by accepting officer. |
| 142 | All as per serial item No. 20.093 above but for 160 KVA (128 KW) capacity of DG Set. |
| 143 | M&L for Cutting existing DI pipe 250mm dia for insertion of reducer DI Tee, size 250x250x100mm including all alterations or additions, fittings and jointing materials complete all as specified and directed. |
| 144 | Supply, install, testing & commissioning of Air release valve, Cast iron, double air outlet, flanged ends, 100 mm connected to 100mm dia main line, ISI marked conforming to IS 14845 including making new flanged joints with 3 mm thick rubber gasket with necessary bolts, nuts, washer etc of suitable size complete all as specified anddirected. |
| 145 | Supplying, laying in trenches and testing of centrifugally cast (spun) ductile iron pipes of 100 mm dia suitable for pressurized water delivery with spigot & socket end, class \"K-7\" conforming to IS:8329/2000 (latest version) - blast furnace slag cement with portland cement propertiies suitable for (push on) rubber gasket jointing with inside cement mortar lining and black bitumen external coating, duly ISI marked in any length complete all as specified and directed.Note:- The cost of welding/concrete work required for proper fixing/connection of the pipe line is deemed to be included in the unit quoted rates. |
| 146 | Supply, install, testing and commissioning of openwell submersible pump set with cast iron impeller, directly coupled with motor, suitable for minimum total head 28 meter and discharge min 14 CUM/HR operated on AC 3 phase, voltage 415V, 50 Hz. The motor casing shall be of cast iron, pump shaft / motor shaft shall be of stainless steel. The pump and motor shall comply to all the requirements of relevant IS. complete all as specified and directed (1W + 1S)NOTE : (i) Design / Drawing / BOM of the pump set including complete accessories is to be obtained from Manufacturer / Supplier & is to be got approved from the Engr-in-Charge & GE before placing final order to the manufacturer.(ii) The cost of foundation/grouting for pump set is deemed to be included in the quoted rate. |
| 147 | S&F Flat Three Core weather proof PVC Insulated & PVC Sheathed Industrial Cable for Submersible pump, multi stranded copper conductor 1100V, 4 sqmm conforming to IS:694 for connection from starter to pump sets complete all as specified and directed. |
| 148 | S&F MCB TP 16 Amps,415 Volts,10 KA, \"C\" series complete all as specified and directed. |
| 149 | Supply, install, testing and commisioning of factory made pump controller in Galvanised steel sheet enclosure of IP55 protection, with DOL starter suitable for motor rating upto 7.5 HP, AC 3 duty, 415 V (Coil Voltage - 200-400 V), 50 Hz, 3 Phase, relay range 9-14 A complete with specifications :-Contactor : Heavy duty 4 Pole ContactorDigital Ammeter : 0-50A R-Y-BDigital voltmeter : 0-500V RY-YB-BROverload protection & Under load ProtectionOver voltage & under voltage protectionSingle phase preventer : with current and voltage sensingSwitch : Auto-ManualPower and control wiring : CopperOutput : TerminalsLED Indicating lamp : Motor ON & Trip indication, R-Y-B Push button : ON/OFF |
| 150 | M&L for construction of brick masonary in cement mortar (1:4) valve pit of internal dimension 1200 mm x 1200 mm x 1200 mm including 3.15 mm thick MS Sheet cover,angle iron frame made out of 50 mm x 50 mm x 6 mm MS angle iron,hinges, locking arrangement , 15 mm thick plaster in cemrnt mortar (1:4) internally, 20 mm thick plaster in cement mortar (1:6) externally up to 15 cm depth fro the ground level, two coats of black bituminous paint over a coat of red oxide primer on MS cover both internally and externally, 150 mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate at bottom with 100 mm clear projection from the outer face ofbrick wall all round,including necessary earth work complete all as specified and directed. |
| 151 | S&F Ultrasonic type water level sensor for 01 for UG sump, with dead band of less than 0.6 meter, IP 66 protection, accuracy of 0.25% of /f.S and RS485 Modbus RTU communication protocol, capable for working in ambient temperature of 0 degrees to 75 degrees centrigrade, non-condensing at 25 degree centrigrade and humidity up to 95% with response time of less than 1 sec with 230 V AC to 24 V DC, 50 HZ power supply LCD display type, vertical type mounting on water tank with all connections and fixing including clamp, nits, bolts complete of size all as.The spcified level sensor shall be equipped with QR codes designed for geo-tagging purposes.These QR codes shall integrate with an asset management system, allowing for efficient tracking and management of the level sensor.By scanning the QR code, userrs should be able to access derailed information about the asset\"s location, usage history, maintenance schedules, and performance data.This system shall enhance the visibility and control over the assets, ensuring the are effectively monitored and maintined. Geo-tagging via QR codes should provide a streamlined solution for asset tracking, improving operational efficiency and reucing the risk of asset loss or mismangement complete all as specified and directed. |
| 152 | Supply, Installation, Testing & Commissioning of Magnetic Float Operated Pivoted Level Switch (FPS) high, low or intermediate point level switching and ideal for over head tanks with inaccessible tops or bottoms complete with following Specifications :-Installation : Normally slide / Top for special applicationsEnclosure X Cable entry: Cast AI IP66 x PG 11 Gland MOC : SS316Float Dia x Min SG : Ø50/Ø60 x SS (≥0.7 SG)Process Connection : Flanged or srewedMagnetic Switch Assembly : Micro switch in hermetically sealed casing (SPDT) 5A, 250VAC / 24 VDCSwitching Differential : Fixed : 15 ± 5 mm Adjustable : between 40 & 300 mm depending upon float, trim length & cam positioning for SS MOCRepeatability / Accuracy : ± 1 mm / ± 2 mm Load / Insulation : Resistive / 150 M Ohm at 500 VDC (Min)Temperature Range : StandardFinish: Regular |
| 153 | S&F SCADA ready actuated electri butterfly valve for 100 NB size water supply systems, with open area installation line pressure maximum-7 Bars , Ends-wafer, Duty -on/off, 230 V AC/24 V DC, IP 67, enclusore, insulation class F, complete with travel switch and torque switch of size 100 NB (may reduce as per site). The specified butterfly valve shall be equipped with QR codes designed for geo-tagging purposes.These QR codes shall integrate with an asset management system, allowing for efficient tracking and management of the level sensor.By scanning the QR code, userrs should be able to access derailed information about the asset\"s location, usage history, maintenance schedules, and performance data. This system shall enhance the visibility and control over the assets, ensuring the are effectively monitored and maintined. Geo-tagging via QR codes should provide a streamlined solution for asset tracking, improving operational efficiency and reucing the risk of asset loss or mismangement complete all as specified and directed. |
| 154 | S&F electromagnetictype flow meter suitable for 100 mm bore pipe, flow range: 0 to 200 cu .mtr/hr, liquid clean /semi clean water, wire length min 10 mtr, with IP-67 protection, 1.4 KV isolation, accuracy of less than± 0.3% of MV, linearity of 0.5 % of MV, mounting in horizontal position, water pressure: Nominal pressure upto 200 KPa, shouldaccountfor the water hammer depending on the valve closure time, current output:4 to 20 mA, local indicating through LCD display and RS 485 Modbus RTU communicationprotocol, capable of working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade and Humidity upto 95% with response time of less than 1 Sec, workingon 90-250V AC, 50Hz, Body and flanged material SS 304 or higher grade steel electrode material standard hastelloy, including necessary welding work, cutting of existing MS/DI/CI/GI piupe line and inserting newXX mm bore MS pipe with necessary MS bends and straight pipe upto 06 mtr and connectingwith existing pipe line with necessary flanged, nut, bolts, gasket and DI/CI specials.The flow meter must have inretface with computer / laptop & should be able to monitor & control from computer, quoted rate shaa also include necessary Hardware/software) complete all as specified and directed. Make: Krohne, omega, onicon, E&H mgt, ABB, Siemens. Note : The cost of wires/ cables any size/ type and length required at site as per OEM,s requirementsincluding all accessories requiredfor proper functioning of the plant deemed to be included with this item. |
| 155 | Supply, Installation, Testing and Commissioning of pressure transmitters in the water supply lines.The Pressure Transmitter needs to be with proper wiring including necessary with following specification complete all as specified and directed:- Pressure Range: 0 bar to 16 barEnclosure : Weather proof IP 65Ambient temperature : -40 TO 70 Deg CAccuracy : 0.5 %Must have RS485 Modbus enabled communication |
| 156 | Supply installation and commissioning of RS485 Communication cable, two pairs stranded copper, (7*32) tinned copper conductors, polyethylene insulation, twister pairs, aluminium / polyster 100% coverage, Tinned copper braid shield 90% coverage, 24 AWG strained tinned copper drain wire, armoured, PVC jacket with the following specifications:(i) Outer jacket : Polyvinyl Chloride, 0.34 in(ii)Conductor DCR : 24 Ω/100 ft(iii)Nominal outer shleid DCR : 2.2 Ω/100 ft(iv)Nominal capacitance conductor to conductor : 12.8mF/ft(v)Nominal capacitance conductor to other conductor to shield 23 mF/ft(vi)Nominal capacitance conductor to conductor : 12.8mF/ft(vii)Frequency : 1 Mhz(viii)Nominal insertion loss : 0.6 DB/100m |
| 157 | Supply, installation, Testing and commissioning of UPS of suitable capacity with adequate battery back up consisting of sealed maintenance free batteries with weatherproof enclosure and locking arrangement complete including electric connection from tapping and to PLC based control panel with armoured copper wire including isolation transformer and surge protection device complete all as specified and directed. Note : - (i) The scope of work includes intergrating the UPS with PLC based panel so as to ensure that the PLC based panel, communication panel and the motorised valves, sensor, electromagnetic flow meter are functional even in case of power failure for a mimimum of 30 Min.(ii) UPS shall be provided at Pump House |
| 158 | Supply, Installation Testing & Commissioning of Indoor type PLC (Programmable Logic Controller) / RTU (Remote terminal Unit) based Automation, Protection Panel for UG & O/H Service cum Fire tank, Pumps & Valve operation, energy monitoring with feature of wireless Dual SIM Card based communication, suitable for control and monitoring of 2 Nos. openwell Pumps, 1 No. Motorized Butterfly Valve, 01 No Ultrasonic level sensor, 01 No Techtrol Magnetic Float Operated Pivoted Level Switch, 1 No pressure transmitters, 01 Nos. electromagnetic Flow Meters. The panel should be of suitable size front opening type, fabricated from 2.00 mm thick CRCA Sheet & mounting channel 40x40x5mm made out of Angle iron with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size. The Panel should have the following functionalities complete all as specified and directed:- (a) Protection Panel for Borewell monitoring & Control.(b) Automatic Pump On/Off, Automatic Priming and Air Release (if reqd)(c) Automatic Operation of Motor Actuated Butterfly Valves & level control of semi-UG sump(d) Automatic Toggling of Pumps(e) Auto Change Over in Case of Pump Failure(f) Pressure Gauges / Transmitters shall be installed in piping systems to measure drop across.(f) Single Phasing Prevention, phase sequence corrector(g) Online UPS with battery system of adequate capacity. (h) Manual Mode Operation (all connected sub systems at filtration plant) from the RTU/ PLC based Control Panel. |
| 159 | Serial item No. 20.110 continued.....(j) Additionally the panel should have following specifications:- (i) Discrete Input Logic: - Sink/Source, Discrete Output Logic: - Positive Logic (Source).(ii) Should have suitable No. of Discrete Input conforming to IEC 61131-2 Type - 1 & Discrete Output: - Relay/Transistor (iii) Protocol supported : isolated serial link: Modbus master/slave and DNP 3.0 (iv) Standard supported :- ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, EN/IEC 61131-2:2007(v) Web Services:- Integrated Web Server(vi)Should have 02 Nos. isolated RS 485 communication port, 1 Nos. Ethernet communication port with 10BASE-T/ 100BASE-TX. Should be able to latch with minimum number of Slave: - 64 Modbus TCP, & adequate DNP3.0 master/ slaves.(vii)RTU/ PLC shall be based on ARM based Controller with at least 600GHz clock frequency and 512MB RAM(viii)PLC/RTU shall be certified by NABL for electromagnetic compactability and radio distrubance standards as per CISPR22, IEC 61000-4-2:2008, IEC61000-4-3:2010, capable of sending data to multiple route and on precise location.(ix)Contractor shall consider in quoted rates for any changes in logic within 5 years of installation as per requirement of department.(x)There shall be 01 No. HMI- 10\"Graphical Touch screen display with following specifications :(xi)01 No. RS 485 and 01 No. USB port& Ethernet port(xii)Serial multilink, USB downloading port& Ethernet port(xiii)Support external data storage on a USB memory stick for storing production data and backing up applications.(ixx)01 No. SMPS of 6.5 A or above rating (to be decided as per panel design by the contractor) as suitable according to panel design.(xx) Suitable No. of interposing relays of220VAC or 24VDC coil rating and 4A contact rating. (xxi) Suitable No. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays. |
| 160 | Supply, Install, Testing and Commissioning of 11kV 630 Amps 21 KA for 3 Sec.SF6 insulated, both side extensible, outdoor duty Ring main unit, fully motorized, in combination of 2 Nos. Load Break Switch as incomer, 01 NosVCB module as Outgoing, 1 No. LBS as Bus - Sectionalizer (CSLVC), consisting of copper busbar in SF6 insulated 304 (Non - Ferrite Non - Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. The Breaker shall have mechanical ON/OFF indicator with hand trip device and spring charging, spring release coil. The HV switchgear and control gear should be confirming to IEC - 62271-1,100,200. The RMU gas tank should be internal arc tested for 21 KA for 1 second with IAC - AFLR classification for gas tank. The complete RMU mimic and cable chamber should be covered by a single door to have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing and VI of VCB should be RMU Manufacturer\"s own make. RMU should have following:- 1 No, microprocessor based self powered numerical relay with Over Current / Earth fault & short circuit protection (with Rs 485 port and modbus protocol) in each VCB feeder, Relay should display each phase current.- 3 Nos, Protection CT shall be of Burden 2.5 VA, ratio 200 - 100/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB outgoing feeder. |
| 161 | Serial item No. 20.111 continued.....(CT ratio is indicative and may vary during detailed engineering).- 1 No Manometer for each tank- 1 No Voltage passage indicator for each feeder.- There must be mechanical interlock between Incomers and bus sectionalizer. Note for RMU :- (i) Cost of supply and fix of RMU havingterminals / disconnecting links for termination of CT wiring including fuses complete all as required at site are deemed to be included in the quoted rate. (ii) Cost of Foundation including construction material as per manufacture design complete is deemed to be included in the quoted rate.(iii) Rate is inclusive for dismantling, taking down existing HT cable from 4 pole / 2 pole structure and connecting RMU.(iv) Rate of cable end joint shall be measured and paid seperately under relevant item.(v) Cost of additional base channel required at site shall be measured and paid seperately.(vi) Rate is inclusive for any other works which are not included in item but required at site for commissioning of RMU / VCB including marking, numbering, by synthetic enamel paint providingdanger board etc.(vii) Contractor shall provide AMC include callibration of HT panels, VCBs, CT / PTs, Relay settings for the RMUhere in above under defect liability period (DLP) i.e 24 months by engaging Service Engineer from OEM of eqpts without any extra cost and site inspection, testing and callibration report will be submitted on before commissioning and subsequently once in six months to Engr-in-charge .(viii) Rate is inclusive for submitting completion Drg and network details after testing & commissioning but before completion of work. Display board (illuminated) of size not less than 2.0 Mtr x 1.5 Mtr shall also be provided by the contractor at MRS Sub Stn without any extra cost. (ix) Detail Technical Specification of SF6 Metal enclosed, Outdoor / Indoor Ring Main Unit (RMU) as per Particular Specification . |
| 162 | Supply, Installation, Testing and commissioning of Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head existing End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per existing AMR infrastructure available in the station. The smart meter may be based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter shall be inclusive of SITC of CT havingRated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (800/5) complete all as specified and directed. |
| 163 | Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (TTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Outdoor factory fabricated of 3.15 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour wit necessary insulators for incoming/outgoing Circuit breakers including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded up to 30 cm complete as latest edition of IS 8623, IS 13947 & IS 2147 all as specified in technical specification mentioned in PS clause and directed. (Main LT panel at SS)INCOMING:-ACB 4 pole, 800 Amps, 50 kA, Microprocessor based with LSIG protection alongwith complete connected assy as per OEM Manual draw out type,- 01 No. (Main LT panel - Substation) |
| 164 | Serial item No. 20.113 continued.....OUTGOING:-(a) MCCB 4 P 400A, 36 kA, Miroprocessor based electronic release with LSIG protection - 02 No(For Bldg Non-DG load & Utility 250 kVA DG AMF panel)(b) MCCB 4 P 250A, 36 kA, Miroprocessor based electronic release with LSIG protection - 02 No(01- 160kVA DG AMF panel, 01 Spare)(c) MCCB 4 P 125A, 25 kA, Thermal Magnetic based, adjustable range 0.7 to 1 In - 02 No (01-Solar, 01-Spare)(d) Intelligent panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs -01set(e) LED indicating lamps with colour R,Y,B - 01 set |
| 165 | Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection plinth mounted Outdoor factory fabricated of 3.15 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour wit necessary insulators for incoming/outgoing Circuit breakers including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20 mm graded crush stone aggregate up to 30 cmas latest edition of IS 8623, IS 13947 & IS 2147 complete all as specified and directed. (Utility panel near AMF panel - DG power) |
| 166 | Serial item No. 20.114 continued.....INCOMING:-MCCB 4 pole, 400 Amps, 36 kA, Miroprocessor based electronic release with LSIG protection- 01 No.OUTGOING:-(a) MCCB 4 P 320A, 36kA, Miroprocessor based electronic release with LSIG protection - 01 No (To Bldg Utility panel)(b) MCCB 4 P 160A, 25kA, Thermal Magnetic based, adjustable range 0.7 to 1 In - 02 No (For Fire pump panel + 01 Spare)(c) MCCB 4 P 16A, 16kA, Fixed Thermal Magnetic release - 03 No (01 S/S, 01 Street light, + 01 Spare)(d) Intelligent panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs -01set(e) LED indicating lamps with colour R,Y,B - 01 set(f) Cost of plinth for mounting of panel is deemed to be inclusive in the quoted rate of contractor |
| 167 | Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Indoor factory fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour wit necessary insulators for incoming/outgoing Circuit breakers including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded up to 30 cm complete as latest edition of IS 8623, IS 13947 & IS 2147 complete all as specified in and directed.(Admn Bldg EPCC panel - DG power) |
| 168 | Serial item No. 20.115 continued.....INCOMING:-MCCB 4 pole, 250 Amps, 36 kA, Miroprocessor based electronic release with LSIG protection- 01 No.OUTGOING:-(a) MCCB 4 P 63A, 16kA, Fixed Thermal Magnetic release - 06 No (Each at one floor + 01 Spare)(b) MCB 4P 6-32A, 16 kA \"C\" curve - 03 Nos (01-Bldg faccade lighting, 01-Security light, & 01-Spare)(c) Intelligent panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs -01set(d) LED indicating lamps with colour R,Y,B - 01 set |
| 169 | Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Indoor factory fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour wit necessary insulators for incoming/outgoing Circuit breakers including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded up to 30 cm complete as latest edition of IS 8623, IS 13947 & IS 2147 complete all as specified and directed. (Admn Bldg - Non DG power)INCOMING:-MCCB 4 pole, 320 Amps, 36 kA, Miroprocessor based electronic release with LSIG protection- 01 No.OUTGOING:-(a) MCCB 4 P 63A, 16kA, Fixed Thermal Magnetic release - 04 No (1st, 2nd & 3rd floor + 01 Spare)(b) MCCB 4 P 40A, 16kA, Fixed Thermal Magnetic release - 03 No (Ground & Roof floor + 01 Spare)(c) Intelligent panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs -01set(d) LED indicating lamps with colour R,Y,B - 01 set |
| 170 | Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Indoor factory fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour wit necessary insulators for incoming/outgoing Circuit breakers including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded up to 30 cm complete as latest edition of IS 8623, IS 13947 & IS 2147 complete all as specified and directed. (Utility panel at Admn Bldg- DG power)INCOMING:-MCCB 4 pole, 320 Amps, 36 kA, Miroprocessor based electronic release with LSIG protection- 01 No.OUTGOING:-(a) MCCB 4 P 200A, 16kA, Fixed Thermal Magnetic based - 02 No (For VRF AC unit + 01 Spare)(b) MCCB 4 P 16A, 16kA, Fixed Thermal Magnetic based - 04 No (For lift -03 Nos + 01 Spare)(c) MCB 4P 16A, 16kA, \"C\" curve - 03 No (01-Fire alarm, 01-Terrace pump + 01 Spare)(d) Intelligent panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs -01set(e) LED indicating lamps with colour R,Y,B - 01 set |
| 171 | Supply, Installation, Testing & Commissioning of Feeder Field Controller for RMU automation (RMU), complete with all accessories suitable for application for Distribution Automation system, wherein the said Feeder Field Controller shall be capable of getting integrated to SCADA Control Centre, with establishment of communication link. The said Feeder RTU shall have at least 16DIs, 4AIs and 12DOs. (Field Controller Makes: Deos Automation (Open.wrt), Schneider (Easergy), Right Watts (RB4.x), Siemens(A8000)). The Field Controller should be mounted in a panel of size400mm x 800mm x 300mm (minimum) fabricated from 1.6mm thick CRCA sheet and must be powder coated. It shall be installed at indoor and, and shall be consisting of following:A. Panel Specifications (Field Controller shall use IEC 60870-5-104 and IEC61850 communication protocol for communicating to master station) and shall have the following specifications:(i) A Programmable Field Controller, with bidirectional operation on at least on DNP3.0/ Modbus/ DLMS/ IEC61850/IEC61870-5-104 protocols (all mandatory and selectable), having at least 800 MHz processor, having operational temperature from 0-70degC (commercial grade) with 512 MB RAM, along with following type test certificates from any NABL approved lab (The certificates must bear the NABL logo on it). It must have: LAN (ethernet ports): 3Nos. (10/100Mbps full duplex) RS485: 2 Nos ports, USB port for enabling fast transmission. |
| 172 | Serial item No. 20.118 continued.....Conducted and Radiated Emission test as per CISPR 22:2018, Immunity to Electrostatic discharge Test as per IEC 61000-4-2 ::2008, Immunity to Radiated Test as per IEC 61000-4-3-2010, Immunity to fast Transients Test as per IEC 61000-4-42012, IEC 61000-4-5:2014 (Up to 2 KV), Immunity to RF fieldinduced conducted disturbance Test as per IEC 61000-4-6:2013, Power frequency IEC 61000-4-8, Dry heat IEC 60068-2-30 (per cycle) Damp Heat IEC 60068-2-30 (Per cycle),mDielectric strength cl.6.8 of IEC 61010-1 (i) with stated Digital and analog Inputs / outputs, expansion modules, RTC etc. (ii) suitable for working on fiber optic, GPRS and CAT6 cable, (iii) Transformer/ SMPS with regulated output voltage of 230V +/- 5%, (iv) along with inbuild modem to transmit data over 4G with fallback to 3G/2G that shall be enabled on MBIM/ QMI protocols (communication products (such as Modems) from the countries sharing land borders with India shall NOT be accepted)(v) Set of Control Relays and suitable MCB and (vii) audio visual indicator etc. (vii) Suitable No. of LED Indicators for easy visualization (viii) Selector Switches (ix) Push Buttons/ Illuminated Push Buttons (x) 1.5 sqmm multistranded internal wiring with ferruling and suitable lugs.(xi). Panel should communicate with Central System through hard wired/wireless connectivity.The installation shall be complete and operative in all respects (site testing with simulator may be done with third party) and shall conform to the highest standard of engineering, design and workmanship. |
| 173 | S&F Cast iron cable route indicator width 4\" with embossing mark as HT/LT cable, shall be directly burried into the ground and having withstand capacity in all type of weather conditions and physical impact and painted with bright colour. complete as specified and directed |
| 174 | S&F street light junction box mistral IP 65 thermoplastic enclousers with transperent door 4mm thick in 4 modulus in single row of size 52 x 202 x 117 with SP 0.5 Amp MCB and including clamp of size 25x3 mm thick of flate iron with bolt, nut etc required in mounting in steel tubular pole 9.0 mtr long complete all as specified and directed. |
| 175 | Fabrication, supply, installation, testing & commissioning of IP-66, IK10 protection, outdoor type, double door pedestal, Street light timer controlled panel of 5kW,3 phase, 4 wire, 415 Volt AC, 50 Hz with an astronomical timer driving two three phase feeders complete with floor mounted, fabricated of 3.15 mm CRCA MS sheet of suitable size with UV-stable gasket, duly powder coated complete with locking arrangement, earthing terminals, with FRLSH control wiring includingmounting Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs with all complete accessories. Complete panel unit grouting60 cm above ground level by providing necessary angle iron support on all four corner embedded in PCC (1:2:4) using 20 mm graded up to 30 cm with the following:-Bus-bar : 3P+1N - Aluminium busbar, 40 A mounted on 1.2 kV insulation sleeves, form-2bIncomer : 4P 25A MCCB, 10kA, adjustable thermal magnetic release - 01 NoOutgoing : (i) MCB 4P 16 A, 10kA \"C\" curve - 02 Nos(ii) Power contactor - 4P, 16-20 A AC - 01 No(iii) Surge Protection device Type 2, 3P+N, Uc 275 V (N-PE)/320-350 V (L-PE), Imax≥20 kA per pole, with thermal disconnector and remote contact - 01 NoControl & automation:- |
| 176 | Serial item No. 20.121 continued.....(i) Astronomical timer : Legrand Astro Rex or equivalent, 2 channel, 230V AC, ≥per chan(pilot duty), lay/long programmable, DST auto, ±120 min offset - 01 No(ii) 3 position (Hand-Off-Auto) selector - 01 No(iii) Master bypass : AUTO/BYPASS selector to force panel ON irrespective of timer - 01 No(iv) Manual OFF pushbutton -02 (per outgoing feeder)(v) LED indicating lamps with colour R,Y,B - 01 setNote: (i) Clearance for 25% future feeders shall be made provisioned(ii) The cost of earthwork, panel foundation is deemed to be included in the quoted rate of contractor |
| 177 | M&L for connection of junction box to street light luminaire using wiring with two runs (P-N) of single core 1.5 Sqmm (nominal area) FR PVC insulated and unsheathed multi-stranded copper conductor cable 1100 volts grade and one run of FR PVC insulated and unsheathed multi-stranded copper conductor of size 1.5sqmm single core as earth continuity wire drawn through PVC conduit (Heavy grade) and tightening/fasteningthe same by aluminium strip with the pole complete all as specified and directed. Notes :- Two run of single core 1.5 Sqmm wire and one run of single core 1.5 Sqmm earth conductor wire and one run of PVC conduit all together shall be measured as one unit. |
| 178 | Supplying and laying of DWC HDPE pipe ISI marked of size 120mm m dia (OD-120 mm & ID-103 mm nominal) along with all accessories like socket, bend, couplers etc. conforming to IS:14930, Part Ilwith fitting and cutting, jointing etc. in the existing trench as required complete all as specified and directed. |
| 179 | Supplying and laying of DWC HDPE pipe ISI marked of size 90mm m dia (OD-90 mm & ID-76 mm nominal) along with all accessories like socket, bend,etc. conforming to IS:14930, Part Ilwith fitting and cutting, jointing etc. in the existing trench as required complete all as specified and directed. |
| 180 | M&L for construction of platform of size 3.00 x 3.00 x 2.00 m high from GL for plinth mounting of transformer of capacity 500 KVA,including excavation in trenches not less than 1 mtr, PCC (1:5:10) type E2 for foundation, brick work in cm (1:6), PCC (1:2:4) type B1 in copping, plaster 10 mm thick in cm (1:6) on brick / concrete surface, 75 mm thick PCC (1:4:8) type B1 as in sub base , 100 mm thicPCC (1:2:4) type B1 as in floring using extra cement, returning filling and removal on surplus soil, chain link fencing 1.8 m high made out of 4 mm dia of GI wire 150x100mm mesh, MSangle iron 50x50x6mm as fencing post in embeded in brick /PCCat 2 mtr interval each side as approved 1 No steel gate (3.5m clear) spanwith locking arrangement made out of 15 mm dia ms rod & 50x50x6 mm angle iron frame, painting with 2 coats of aluminium paint over a coat of red oxide primer and 3 coats of white washing on cement work including 2 Nos ISMB 100 mm chanel for fixing transformer including ramp of suitable size mounting of transformer and suitable size of steps/ stairs over plate form complete all as specified and directed. |
| 181 | Design, supply, installation, testing and commissioning of Roof Top Solar Power Generation plant of capacity 50 kW (AC) (Minimum 60 kWp) (DC) at output voltage 415 volt, 50 Hz, on grid connected complete with structure and foundation comprises design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lightning arrester, weather station, SCADA system, earthing, connecting wires/cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as per DBR. (Annexure-I)Note : Contractor shall also ensure the followings:-(i) Annual maintenance contract for 05 years complete all as specified and directed (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer(iii) Repairing of all installations if required will be carried out on site or at service center. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.(iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer-in-Charge(v) Security of all SPV equipments shall be complete responsibilities of Station Authorities. |
| 182 | Boring for bored cast-in-situ piles 600 mm dia. in any type of soil using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed. |
| 183 | Boring for bored cast-in-situ piles 1200 mm dia. in any type of soil using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed. |
| 184 | M&L for Reinforced cement concrete (design mix) M-30 grade design mix as in Cast-in-situ piles etc., complete all as specified and as directed. Note: Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate quoted shall be deemed to included this aspect. |
| 185 | M&L for Reinforced cement concrete (design mix) M-35 grade design mix as in Cast-in-situ piles etc., complete all as specified and as directed. Note: Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate quoted shall be deemed to included this aspect. |
| 186 | Carrying out initial pile load tests for 600 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 187 | Carrying out initial pile load tests for 1200 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 188 | Conducting low strain integrity test on 600mm diameter RCC cast-in-citu piles, data analysis and submission of report. (min 10 piles per visit) complete all as specified and directed. |
| 189 | Conducting low strain integrity test on 1200mm diameter RCC cast-in-citu piles, data analysis and submission of report. (min 10 piles per visit) complete all as specified and directed. |
| 190 | Carrying out routine pile load tests for 600 mm diapile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 191 | Carrying out routine pile load tests for 1200 mm diapile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 192 | PHASE II (COMPREHENSIVE MAINTENANCE WORK) |
| 193 | Comprehensive Maintainanceof 2 x 18 HP and 2 x 20 HP VRF AC plantwith AHU ducted air distribution system by OEM/ Authorised dealer of OEM including preventive maintainance services and attending all call breakdowns.Checking, maintaining and ensuring smooth function of the Air conditioning system equipments without any abnormalities in noise, temperature,pressures and current drawn by the motors and carrying out rectification/repair/replacement of defective parts.The key inclusion in the contract are maintaince and repair/replacement of following components in Air conditioning system:- (a) VRF outdoor unit (b) Refrigeration circuit(c) AHU(d) Ducted air distribution unit with complete control unit (e) All the electrical components /sensors/control panel/Remote Monitor units connected toOEM control panel. The scope of work under AMC inclusive the following:-(a) 04 (Four) routine services in a year on quarterly basis includes:- (i)Checking of cooling efficiency and tunning of system for its efficient operation. (ii) Checking of motors, control circuits & panels, communication unit. (iii)Cleaning of evaporator and condenser coils, blowers & fans, AHUs, duct system, diffusers, dampers, etc (iv)Checking tightness of regular operational units like motor, pump, belt and otherunits to ensure its smooth operation..(b) Immediate attendance of breakdown, if any.(c) Repairing of leakage, Refrigerant gas charging, if necessary. |
| 194 | (a) Comprehensive annual maintenance of complete VRF AC unitheld at Admin Bldg, 3 Corps, RMS for first year after defect liability period complete all as specified and directed. |
| 195 | (b) Comprehensive annual maintenance of complete VRF AC unitheld at Admin Bldg, 3 Corps, RMS for second year after defect liability period complete all as specified and directed. |
| 196 | (c) Comprehensive annual maintenance of complete VRF AC unitheld at Admin Bldg, 3 Corps, RMS for third year after defect liability period complete all as specified and directed. |
| 197 | Comprehensive Maintenance of electrically operatedpassenger lift capacity of 13 Passenger (884 Kg) covering the following major aspect of preventive maintenanceand attendeing repair work including identifying of faults, replacement of all faulty spares for optimum performance and maximum safety of LIFT (G + 4) floors by OEM / authorised dealers all as specified and directed.Notes (i) Rate deemed to included to replace spare parts as required at site.(ii) Servicing to be done monthly once and intermittent repair work to be done against fault occurs by OEM/Authorised dealer & spares shall be procured from OEM (iii) Servicing periodically all wire ropes and chains [where fitted] as often as required to maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair or replace conductor cables and hoist way and machine room elevator wiring.(iv) Servicing periodically all safety devices and governors and make all customary safety tests.(v) Systematically servicing and adjust the following components: Machine, Worm Gear, Thrust Bearings, Drive Sheave, Drive Sheave Bearings, Break Contact, Lining and components, gear oil/lub oil.(vi) Servicing of Motor, Rotating Elements, Commutator, Brushes, Brush Holders, Bearings, Coils,Resistance for operating and Motor Circuits, Magnet Frames & other Mechanical parts.(vii) Servicing & replace defective parts of Controller, Selector, Leveling devices, Cams, relays, solid State Components eg. PCB’s, Transducers, Resistors,Condensers, Power Amplifiers, Transformers, Contacts, Leads, Dashpots, Timing Devices, Steel Selector Tapes and Mech,& Electrical Driving equipment.(viii) Servicing & replace defective parts of ARD,infrared device and Amplifiers/Sills. |
| 198 | (a) Comprehensive annual maintenance of lift held at Admin Bldg, 3 Corps, RMS for first year after defect liability period complete all as specified and directed. |
| 199 | (b) Comprehensive annual maintenance of lift held at Admin Bldg, 3 Corps, RMS for second year after defect liability period complete all as specified and directed. |
| 200 | (c) Comprehensive annual maintenance of lift held at Admin Bldg, 3 Corps, RMS for third year after defect liability period complete all as specified and directed. |
| 201 | Comprehensive annual Maintenance of DG set 250 kVA covering the following major aspect of preventive maintenanceand attendeing repair work including identifying of faults, replacement of all faulty spares for optimum performance and maximum safety by OEM / authorised dealers all as specified and directed.Note : 1The Tender shall carryout the following works during Annual Maintenance Contract period along with the servicing of the Diesel Generator sets:-(i) General check up & preventive maintenance as per schedule. (a) Check lube oil level and conditioning of lube oil, top up/refill if required. (b) The oil filters shall be replaced whenever oil is changed. (c) The air filters shall be cleaned periodically with compressed air, check batteries and top up with distilled water if required. (d) Engine safety viz., high water temperature gauge, oil pressure gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.(e) Coolant level and conditioning of coolant shall be checked and refilled if required(g) Check fan and alternator drive belts and tightened if required. (h) The governor shall be checked and tuned for proper functioning.(i) Check for leaks if any and shall be rectified. (j) Check reports shall be submitted every month/during every breakdown calls.(k) Checking and servicing of engine for smooth running, its unusual sound and color of smoke from exhaust and set it right in case of deviations.(l) Checking and repairing the leakage of fuel, lubricating oil and coolant.(m) Cleaning and changing of Air filters as per requirement.(n) Setting of Valves tappets whenever required.(o) Checking and repairing of accessories drive, Turbo Charger and crankshaft endplay whenever required.(p) Checking of alignment and alignment of Engine and Alternator as per requirement.Note : 2For annual comprehensive maintenance of DG set, one DG technician (semi-skilled) on two shift (one day shift and one-night shift) will be provided by the contractor who shall be responsible to attend for routine day to day maintenance and facilitate in case of any failure of DG set. The cost of labour is inclusive in the quoted rate of contractor. |
| 202 | (a) Comprehensive annual maintenance of 250 KVAheld near 3 Corps substation, RMS for first year after defect liability period complete all as specified and directed. |
| 203 | (b) Comprehensive annual maintenance of 250 KVAheld near 3 Corps substation, RMS for second year after defect liability period complete all as specified and directed. |
| 204 | (c) Comprehensive annual maintenance of 250 KVAheld near 3 Corps substation, RMS for third year after defect liability period complete all as specified and directed. |
| 205 | Comprehensive annual Maintenance of DG set 160 kVA covering the following major aspect of preventive maintenanceand attendeing repair work including identifying of faults, replacement of all faulty spares for optimum performance and maximum safety by OEM / authorised dealers all as specified and directed.Note : 1The Tender shall carryout the following works during Annual Maintenance Contract period along with the servicing of the Diesel Generator sets:-(i) General check up & preventive maintenance as per schedule. (a) Check lube oil level and conditioning of lube oil, top up/refill if required. (b) The oil filters shall be replaced whenever oil is changed. (c) The air filters shall be cleaned periodically with compressed air, check batteries and top up with distilled water if required. (d) Engine safety viz., high water temperature gauge, oil pressure gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.(e) Coolant level and conditioning of coolant shall be checked and refilled if required(g) Check fan and alternator drive belts and tightened if required. (h) The governor shall be checked and tuned for proper functioning.(i) Check for leaks if any and shall be rectified. (j) Check reports shall be submitted every month/during every breakdown calls.(k) Checking and servicing of engine for smooth running, its unusual sound and color of smoke from exhaust and set it right in case of deviations.(l) Checking and repairing the leakage of fuel, lubricating oil and coolant.(m) Cleaning and changing of Air filters as per requirement.(n) Setting of Valves tappets whenever required.(o) Checking and repairing of accessories drive, Turbo Charger and crankshaft endplay whenever required.(p) Checking of alignment and alignment of Engine and Alternator as per requirement.Note : 2For annual comprehensive maintenance of DG set, one DG technician (semi-skilled) on two shift (one day shift and one-night shift) will be provided by the contractor who shall be responsible to attend for routine day to day maintenance and facilitate in case of any failure of DG set. The cost of labour is inclusive in the quoted rate of contractor. |
| 206 | (a) Comprehensive annual maintenance of 160 KVAheld near 3 Corps substation, RMS for first year after defect liability period complete all as specified and directed. |
| 207 | (b) Comprehensive annual maintenance of 160 KVAheld near 3 Corps substation, RMS for second year after defect liability period complete all as specified and directed. |
| 208 | (c) Comprehensive annual maintenance of 160 KVAheld near 3 Corps substation, RMS for third year after defect liability period complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail