| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | a) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 4 | a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 5 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 6 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: |
| 7 | (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. |
| 8 | (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. |
| 9 | (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. |
| 10 | (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. |
| 11 | For the purpose of measurement the entire treated surface will be measured. |
| 12 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 13 | a) In 75x75 mm deep chase |
| 14 | 12 mm cement plaster of mix : |
| 15 | 1:6 (1 cement: 6 coarse sand) |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 17 | One or more coats on old work. |
| 18 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 19 | Raking out joints in cement mortar and preparing the surface for filling of open joints with cement slurry in brick tile of terrace for water proofing treatment including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. |
| 20 | Providing and fixing 15 mm nominal bore C.P. brass 2 way bib cock of approved quality as per direction of Engineer-In- Charge. |
| 21 | P/F cPVC make Health Faucet as per direction of E-IN Charge |