| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 3 | a) In cement mortar |
| 4 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 5 | a) 15 mm to 40 mm nominal bore |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level: |
| 8 | a) 1:2:4 ( 1 Cement: 2 M.sand : 4 graded stone aggregate 20 mm nominal size) |
| 9 | Providing and laying cement Concrte in retaining walls, return walls (any thickness) including attached pilasters, columns, piers, abutmets, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc., upto floor five level, excluding the cost of centring, shuttering |
| 10 | a) 1:2:4 (1 cement: 2 M.sand : 4 graded stone aggregate 20 mm nominal size) |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 50 in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 12 | a) Cement mortar 1:6 (1 cement: 6 M. sand) |
| 13 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 14 | a) Using M.S. angels 40x40x6 mm for diagonal braces |
| 15 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 16 | a) Hot finished welded type tubes. |
| 17 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 18 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 19 | a) Barge board (Upto 300 mm) |
| 20 | b) Crimp curve |
| 21 | c) Gutter (600 mm over all girth) |
| 22 | White washing with lime to give an even shade: |
| 23 | a) New work (three or more coats) |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 25 | a) One or more coats on old work. |
| 26 | 12 mm cement plaster of mix: |
| 27 | a) 1:6 (1 cement : 6 M.sand) |
| 28 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 29 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-charge . |
| 30 | a) With cement mortar 1:4(1 cement: 4 M. sand). |
| 31 | Cutting the branches of trees over the roof of the Telephone exchange building including disposal of unserviceable materiasl etc. all as directed by the E-in-c |