| 1 | Providing and fixing overhead cabinets of 18 mm thick Pre-laminated particle boardcarcass & shutter and back ply attached 9 mm thick PLPB with lock handle lace etc of approved brand (Action Tesa/crossbond/Century or equivalent) Size 2100x450x450 mmcomplete as per direction of Engineer-in-charge. |
| 2 | Providing and fixing overhead cabinets of 18 mm thick Pre-laminated particle boardcarcass & shutter and back ply attached 9 mm thick PLPB with lock handle lace etc of approved brand (Action Tesa/crossbond/Century or equivalent) Size 4200x450x450 mm complete as per direction of Engineer-in-charge. |
| 3 | Providing and fixing overhead cabinets of 18 mm thick Pre-laminated particle boardcarcass & shutter and back ply attached 9 mm thick PLPB with lock handle lace etc. of approved brand (Action Tesa/crossbond/Century or equivalent). Size 3600x450x450 mm complete as per direction of Engineer-in-charge. |
| 4 | Providing and fixing overhead cabinets of 18 mm thick Pre-laminated particle boardcarcass & shutter and back ply attached 9 mm thick PLPB with lock handle lace etc. of approved brand (Action Tesa/crossbond/Century or equivalent). Size 1200x450x450 mm complete as per direction of Engineer-in-charge. |
| 5 | Providing and fixing linear work station with Table top 25 mm thick Pre-laminated particle board, 18 mm thick PLPB gable also with 2 mm thick pvc edge banding as per- laminated approved, 45 mm thick aluminium partition half white pin board and half white markar with double racewayfor power point and data cable also wire manager with divider and both side partition of approved brand (Action Tesa/crossbond/Century or equivalent) Size..1200X600X1200 mm |
| 6 | Providing and fixing pedestal with all over making carcass and facia17 mm thick Pre-laminated particle board with 2 mm thick pvc edge banding as per laminated approved, 2 small drawer and 1 big drawer with handle and lock complete of approved brand (Action Tesa/crossbond/Century or equivalent) Size.. 400x450x600 mm |
| 7 | Providing and fixing cabin table with Table top 36 mm thick Pre-laminated particle board, 25 mm thick PLPB gable 17 mm thick PLPB modesty, 2 mm thick pvc edge banding as per laminated approved completeof approved brand (Action Tesa/crossbond/Century or equivalent) Size..1500X750X750 mm |
| 8 | Providing and fixing aluminium partition of 65 mm thick aluminium profilewith ACP sheet and glass 5 mm height 300 mm full finish complete as per direction of Engineer-in-charge. |
| 9 | Providing and fixing aluminium door shutterof60x40 mm thick aluminiumprofileACP sheet of approved brand (Aludecor/ Alucobond/Eurobond/VIVA/Alstone/Alstrong or equivalent) and glass. Glass height not be less than 300 mm full finish complete. Size..600X60X1500 |
| 10 | Providingand fixingaluminiumdie cast body tubular typeuniversal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 11 | Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 12 | Size of Tile 600x600 mm |
| 13 | ProvidingandlayingVitrifiedtilesindiferent sizes (thickness tobe specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 14 | Size of Tile 600x600 mm |
| 15 | Providingandfixingtiledfalseceilingof specifiedmaterialsof size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet,1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like difusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 16 | 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fibermanufacturedthroughautoclavingprocesstogive stablecrystallinestructurewith minimumcompressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coeficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. |
| 17 | Providing andapplyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 18 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 19 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 20 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 21 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 23 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 24 | With cement mortar 1:4 (1cement: 4 coarse sand) |
| 25 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 26 | Of area 3 sq. metres and below |
| 27 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 28 | For thickness of tiles 10 mm to 25 mm |
| 29 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 30 | Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. |
| 31 | With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm. |
| 32 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 33 | For fixed portion |
| 34 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 35 | Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 36 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 37 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 38 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 39 | Add Cost Index@3% on SL No. 10 to 38 |
| 40 | Providing and fixing 12 mm thick toughned glass for aluminium or steelwindow including gasket ruber beading and misc. fittings complete as per direction of Engineer-in-charge. |
| 41 | Supplying and Installation of Roller Blinds (synthetic material) as per direction of Engineer-in-Charge. |
| 42 | Providing and fixing Mortise lock with all accessories godrej or equivalent complet set as per direction of Engineerin-charge. |
| 43 | Deduction for metallic (steel) scrap of buildings like as damaged angles, sheets,bar, steel conduit, rusted GI pipe, damaged door window fittings, damaged sanitary and water supply fittings and similar materials etc. |
| 44 | Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading into approved municipal dumping zone/ground or as approved by Engineer-in-charge, beyond 50 metre initial lead, for all leads including all lifts involved. |
| 45 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 46 | Group C |
| 47 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cablein surface/ recessedmedium class PVC conduit alongwith 1No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 48 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cablein surface/ recessedmedium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 49 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. |
| 50 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 51 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 52 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 53 | Supplying and fixing following rating, double pole, 240 V, isolator in theexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. |
| 54 | 63A |
| 55 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,residual current circuit breaker (RCCB),having a sensitivity current 30mA inthe existingMCBDBcomplete with connections, testing and commissioning etc. as required. |
| 56 | 25A |
| 57 | Supplying and fixing followingrating, four pole, (threephase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existingMCBDB complete with connections, testing and commissioning etc. as required. |
| 58 | 25A |
| 59 | Add Cost Index@3% on SL No. 45 to 25 |
| 60 | Providing and fixing half quarter copper pipe for air conditioner including insulation, wire, casing caping etc. as per direction of Engineer-in-charge. |
| 61 | Supplying and Fixing of600x600 mm false ceiling LED lightof 30-35 watt Phillips/Havells or equivalentapproved brand as per direction of Engineer-in-Charge. |
| 62 | Supplying and Fixing wall mounted fan(Havells/crompton or equivalent) of approved brand as per direction of Engineer-in-Charge. |
| 63 | Providing and fixing GI floor Raceway cable tray of (150x75 MM) 16 Guage i/c junction box with nut bolt coupler with cover to use cables as dividers to seperate the cables and to carry networking cables as approved and directed by Engineer-in-charge |
| 64 | Supplying and installation of 2 ton non-invertor split Air Conditioner Mitsubishi / O General or equivalent, 3 star rating humidity controlled up to 70% including out door stand, copper pipe & drainage pipe (up to 6 metre length) . |