|
| 1 | Excavation in foundation for retaining, breast walls etc, in all types of soils androcks including all lead, lift and disposal of surplus material as per direction ofengineer - in - charge, as per drawing and technical specifications Clause 305.1 ofMORD Specifiction |
| 2 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (P.C.C grade M 10 Nominal mix 1:3:6) |
| 3 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (P.C.CNominal mix 1:2:4) |
| 4 | Randam Rabble(RR) Boulderstone masonary in 1:6 cement sand mortar with Boulderstone in R/wall, B/wall,and Parapets worksi/c all costof material, labours and T&P etc. for proper completion of the work. |
| 5 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. |
| 6 | Hand Packed stone filling in back of wallls including cost of allmaterials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 7 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Brick masonry in 1:3 cement mortar |
| 8 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 9 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 10 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.( 0.63 mm thick with zinc coating not less than 275 gm/ m²) |
| 11 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.( 0.63 mm thick with zinc coating not less than 275 gm/ m²) ( excluding Galvanised steel corrugated sheets ) |
| 12 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 13 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378)- (250x10) |
| 14 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) - (125mm) |
| 15 | Float glass panes { 4 mm thick glass pane (weight not less than 10kg/sqm)} |
| 16 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) - (300x16) |
| 17 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with AluminiumComposite Panel Cladding, with open grooves for linear as well as curvilinear portions of thebuilding , for all heights and all levels etc. including: |
| 18 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete ( Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides) |
| 19 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : ( Of area beyond 3 sq. Metres) |
| 20 | 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 21 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : ( New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution) |
| 22 | 12 mm cement plaster finished with a floating coat of neat cement of mix : ( 1:3 (1 cement: 3 fine sand)) |