| 1 | EARTHWORK: |
| 2 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5M including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50M(a) All kinds of soil. |
| 3 | Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m |
| 4 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete. |
| 5 | CEMENT CONCRETE WORKS: |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering, shuttering,- All work upto plinth level:(a) 1:4:8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) |
| 7 | RE-INFORCED CEMENT CONCRETE WORKS: |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: |
| 9 | (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with |
| 11 | (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: |
| 13 | (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | STEEL REINFORCEMENT: |
| 15 | Reinforcement for RCC work i/c straightening, cutting, bending, placing in position and binding all complete. |
| 16 | (a) Thermo-Mechanically Treated bars |
| 17 | FORM WORKS: |
| 18 | Providing form work i/c centering & shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in: |
| 19 | a). Foundation, footing, bases of column etc and mass concrete. |
| 20 | b). Column, pillar, posts and struts (square rectangle or polygon in plain). |
| 21 | c). Lintels, beams , plinth beams, girders, bresummer and cantilever withwater proof ply12 mm thick |
| 22 | d). suspended floor,roofslandingbalconies ans access platform withwater proof ply12 mm thick |
| 23 | e).Stairs (excluding Landings) except spiral-staircase. |
| 24 | f). Weather shade, Chhajjas corbels etc. including edges |
| 25 | BRICKWORKS: |
| 26 | Brick work with 1st class burnt clay F.P.S(non modular) bricks in foundation & plinth in cement mortar 1 : 4 (1cement :4 coarse sand). |
| 27 | HalfbrickmasonrywithIstclasscommonburntclayF.P.S.(non modular) bricksin superstructure above plinth level upto floor V level in cement mortar 1 : 3 (1cement :3coarse sand). |
| 28 | WOOD WORKS: |
| 29 | Providing wood work in frames of doors, windows, clerestorywindows andotherframes wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia. And length (hold fast or dash fastener shall be paid for seperately(a) Local best quality Teak wood |
| 30 | Providing and fixing panelled or paneled and glazed shutters for doors,windowsand clerestory Windows i/c ISI marked M.S.butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for seperately, all complete as per direction of Engineer-in-charge.(a)Local best quality Teak wood. -35 mm thick shutters |
| 31 | Providing 40X3mm flat iron hold fast 40cm long i/c fixing to frameswith 10mm dia. Bolts, nuts and wooden plugs and embedding in cement concrete block 30X10X15 cm 1:3:6 mix (1 cement : 3coarse sand: 6 stone aggregate 20mmnominal size). |
| 32 | Providing and fixing bright finished brass 100 mm door mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 33 | Providing and fixing ISI marked oxidised M.S. Tower bolts black finished(barrel type ) with screws etc. complete. |
| 34 | (a) 250x10mm |
| 35 | (b) 100x10 |
| 36 | Providing & fixing ISI marked oxidisedM.S. Sliding bolts with screws etc. Complete.(a) 250X16mm. |
| 37 | FLOORING: |
| 38 | Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with waterabsorption’s less than 0.08% and conforming to IS : 15622 ofapproved make in all colours and shades, laid on 20mm thickcement mortar 1:4 (1 cement: 4 coarse sand) including groutingthe joints with white cement and matching pigments etc.,complete. |
| 39 | Size of Tile 600 x 600 mm |
| 40 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer),with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (Icement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm.including grouting the joint with white cement & matching pigments etc. complete. |
| 41 | Size of Tile 600x600 mm |
| 42 | STEEL WORKS: |
| 43 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffering, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-Charge, (for payment purpose only weight of the stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 44 | Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 45 | FINISHING: |
| 46 | 15mm cement plaster on rough side of single or half wall of mix: 1: 4 (1 cement : 4 coarse sand) |
| 47 | 12mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement . |
| 48 | Providing and applying white cement based putty of average thickness1mm of approved brand and manufacturer over plastered surface to prepare the surface even and smooth complete. |
| 49 | Distemperingwith oil bound washable distemper of approved brand and manufacturer to give an even shade. New work (two or more coats) over and including priming coat with cement primer :- |
| 50 | Finishing walls with Arcylic Smooth exterior paint of requierdshade :New work (two or more coat applied @ 1.67 ltr/10 sqm. Over and including base coat of water proofing cement applied @ 2.20 kg/10 sqm) |
| 51 | Making plinth protection 50 mm cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggrt. of 20 mm nominal size)over75 mm bed of dry brick ballast 40 mm niminal size well rammed ans consolidated and grouted with fine sand including finishingthe top smooth. |
| 52 | I). Watersupply andSanitary Installation |
| 53 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 54 | External work- 50 mm nominal outer dia Pipes |
| 55 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 56 | Internal work- 32mm nominal outer dia Pipes |
| 57 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 58 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 59 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 60 | (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 61 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 62 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia |
| 63 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 64 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. Pan |
| 65 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 66 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 67 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 68 | Providing and fixing toilet paper holder: C.P. brass |
| 69 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 70 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 71 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm |
| 72 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia |
| 73 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring^ conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes . |
| 74 | a).75mm dia |
| 75 | b).110mm dia |
| 76 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cuttingand making good the walls etc.Internal work - Exposed on wall |
| 77 | Internal work - Exposed on wall |
| 78 | 25 mm diameters |
| 79 | 32 mm diameter |
| 80 | Providing and fixing G.I. pipes complete with G.I. fittings including Trenching and refilling etc.external work - |
| 81 | 15 mm |
| 82 | 20 mm |
| 83 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc.complete : 50 to 80 mm nominal bore |
| 84 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 85 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. : 15 mm Nominal bore |
| 86 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 87 | 15 mm nominal bore |
| 88 | 25 mm nominal bore. |
| 89 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 90 | Supplying and Fixing water pump to supply water with necessary fitting. |
| 91 | a) 2 HP water pump |
| 92 | II). WATER RESERVOIR |
| 93 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil. |
| 94 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - a) 1:4:8 (1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 95 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 96 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 97 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement witha) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 98 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 99 | a). Foundations, footings, bases of columns, etc. for mass concrete. |
| 100 | b). suspended floor,roofslandingbalconies ans access platform withwater proof ply12 mm thick |
| 101 | c). Lintels, beams , plinth beams, girders, bresummer and cantilever withwater proof ply12 mm thick |
| 102 | Reinforcement for RCC work i/c straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars |
| 103 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 104 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete..a),40mm thick with 20mm nominal size stone aggregate. |
| 105 | III). SEPTIC TANK |
| 106 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil. |
| 107 | Fillingavailableexcavated earth (excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 108 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - a) 1:4:8 (1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 109 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering --All work upto plinth level: 1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size). |
| 110 | Brick work in 1st class common burnt clay F.P.S ( non modular ) bricks in foundation and plinth in : Cement motar 1:4 (1cement:4 coarse sand) |
| 111 | Honey-comb brick work 10/11.4 cm thick with 1st class common burnt clay FP.S. (non modular) bricks in superstructure above plinth level and upto floor V level in cement mortar 1 : 4 ( 1 cement : 4 coarse sand) |
| 112 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with ( a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 113 | Reinforcement for RCC work including Straightening, cutting, bending,placing in position and binding all complete. |
| 114 | (a) Thermo-Mechanically treated bars. |
| 115 | Providing form work i/c shuttering and centering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m. And removal of the same for in-situ reinforced concrete and plain concrete work in |
| 116 | (a).Foundation, footing, bases of columns etc. and mass concrete. |
| 117 | b). suspended floor, roofslandingbalconies ans access platform withwater proof ply12 mm thick |
| 118 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) |
| 119 | Supplying and fixing C.I. Cover with frame (for manhole and chambers) |
| 120 | 600x450 mm rectangular C.I. Cover (light duty) 23 kg |
| 121 | SH:- Providing of IEI |
| 122 | Sub-Head -I (Wiring) |
| 123 | Wiring for light point / fan point/Exhaush Fan point /call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit with piano type switch,phemolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. |
| 124 | Group C |
| 125 | Wiring for light point /power point plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit alongwith 1 no.4.sq.mm FR PVC insulated copper conductor single core cable for loop earting etc as required. |
| 126 | Wiring for circuit / sub main wiring alongwith earth wire with following size of FR PVC insulated copper conductor, single core cable in surface /recessed steel conduit as required. |
| 127 | a) 2X1.5.mm² +1x1.5mm² earth wire |
| 128 | b) 2X2.5.mm² +1x2.5mm² earth wire |
| 129 | c) 4X4.mm² +2x4mm² earth wire |
| 130 | d) 4x6mm2+2x6mm2 earth wire |
| 131 | Sub- Head-II |
| 132 | ( Fittings & Accessories) |
| 133 | S/F Recess Mounting LED down Lighter BGSL 0101WH,220223,cast aluminium housing fixed with collimated lens,1x1W white LED mounted on MCPCB ,extruded Al heat sink spring loaded mounting clips, complete with connections etc as reqd. |
| 134 | Supplying, installation testing and commissiong of ceiling fan, capacitor type suitable for low voltage operation including wiring the down rods of standard length (upto 30 cm ) with 1.5 sq.mmFR PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (ISI marked approved) |
| 135 | a) 1200 mm sweep |
| 136 | Supplying & fixing stepped type blanking plate on existing modular plate and switch box excluding modular plate as reqd. |
| 137 | Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc. as reqd. |
| 138 | 2) 5/6 amps switch |
| 139 | 4) 3 pin 5/6 amps socket outlet |
| 140 | 3) 15/16 amps switch |
| 141 | 5) 6 pin 15/16 amps socket outlet |
| 142 | Supplying, Installation of exhaust fan upto 305 mm sweep in the opening, including marking the holes to suit the size of above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 143 | Supply and fixxing of following size of PVC casing and capping along with accessories etc. |
| 144 | (a) 20mm |
| 145 | Providing and fixing of lightning conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. complete as reqd. |
| 146 | S/F Bus Bar chamber with 4 strips copper bus bar of length 900mm suitable for 400 amp capacities complete with all accessories i/c connection earthing the body etc. as reqd |
| 147 | Sub- Head- III |
| 148 | (DB,s & MCB,s) |
| 149 | Supplying and fixing 8 way,(2+8 way) single door pole and neutral, prewired, sheet steel MCB distribution board, 240V on surface/ recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate interconnection, including powder coat painting, earthing etc. as required.( But without MCB/RCCB/Isolator). |
| 150 | S/F \"B\" series,SP MCB. Supplying and fixing following 5 amps to 32 amps rating 240 Volts, B series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required. |
| 151 | a) Single Pole and neutral |
| 152 | S/FDP MCBisolator: Supplying and fixing following rating, double pole,240 volts, isolator in the existing MCB DB complete with connection,testing and commissioning etc. as required. |
| 153 | a)100 amps. |
| 154 | Sub-Head - IV |
| 155 | ( Earthing ) |
| 156 | Earthing with Copper earth plate 600mmx600mmx6mm thick i/c accessories, and providing masonary encloure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt ) as required. |
| 157 | P/F 25mmx5mm copper strip in 40mm dia G.I.pipe from earth electrode as reqd. |
| 158 | Sub- Head- V |
| 159 | Switch Gear (Main Switch) Change Over |
| 160 | P/F400 amp. TPN stand ground on load change over switch (Compact design) 415/500 V including connection etc as reqd. |