| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation |
| 3 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)(B) Do - by fine sand |
| 4 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 5 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 6 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 7 | (I) Cement concrete with graded stone ballast (40 mm size excludingshuttering)In ground floor(A) [Pakur Variety](a) 1:3:6 proportion |
| 8 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety |
| 9 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.II. (JSW/JSPL/SHYM/SRMB/BMASL/I/ELECTROSTEEL/SSL) |
| 10 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. IN GROUND FLOOR |
| 11 | (f) 25 mm to 30 mm shuttering without staging in foundation |
| 12 | Brick work with 1st class bricks in cement mortar (1:6) (a)In foundation and plinth |
| 13 | (b) In superstructure, ground floor |
| 14 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor |
| 15 | Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured fromrolled steel sections conforming to IS 7452-1974 with non-frictionprojecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match withexisting surface complete in all respect excluding glazing.In Ground floor(a) Fixed type steel windows as per IS sizes with horizontal glazingbars. |
| 16 | (viii) M.S. integrated grill as per approved design integrated withsteel window or ventilator, joints continuously welded with M.S. Flats and bars. |
| 17 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortarincluding rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excludingcost of chipping over concrete surface](i) With 1:6 cement mortar (b) 20 mm thick plaster |
| 18 | (i) With 1:6 cement mortar (c) 15 mm thick plasterIn Ground floor(ii) With 1:4 cement mortar |
| 19 | Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m |
| 20 | Supplying and laying in the specified patter of Interlocking Concrete Block Pavments(ICBP) with concrete blocks (Either concrete grade as specified as per Table 1 of IS 15658:2006) manufactured in steel mould clamped to a vibrating table by hydraulic pressure(as per cl no. 6.30 of IRC:SP:63(2018), from BIS license manufacturer, with spacer nib (Small prruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per cl no. 3.26 of IS 15658) and of specified size and shape with aspect ratio(The ratio of length to thickness of a paver block, as per cl no. 3.3 of IS 15658) as per Table 2 of IS 15658 with flexrual strength/breaking load as per Annexure G of IS :15658, on the prepared base course of specified CBR as per Table 1 of IRC SP 63(2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35 mm thick (Grading of bedding sand as per clause 6.5.1 of IRC SP 63) and filling up the gaps in between paver blocks with joint filling sand (The gradding of the joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per cl no. 8.7 of IRC SP 63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edges gap.60mm thick. |
| 21 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (asnecessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.In ground floor.3 mm. thick topping (High polishing grinding on this item isnot permitted with ordinary cement).Using grey cement(iii) 35 mm. thick |
| 22 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erectionall complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer InCharge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof.I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 23 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor(ii) Grill weighing above 16 Kg./sq.mtr and above |
| 24 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or bothfaces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost ofall labour and materials. |
| 25 | Suppling, fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT (Base Metal Thickness) (0.50mm TCT (Total coated thickness excluding paint), G550 (min 550 yield strength), of Zincalume metallic coating (IS15965) with high Solar Reflectance Index (SRI) value for better colling as per thermatech technology, 1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg. The steel sheet shall be fastened with 40 micron zinc coated or 25 micron zinc-tin alloy coated, hex head, self-drilling screw as per IS 3566-2002 Class 3 fastener. The base steel shall be coated with zinc-aluminium alloy Zincalume (AZ150)(i.e. 55% Al, 43.4% Zinc, 1.6% Si) minimum of 150 g/m2 coating total on both sides, pre-painted with colorbond XRW (xterior roofing, walling) paint system of 35 micron Super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material. A) WITH 0.5 MM THICK SHEET. |
| 26 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.In Ground Floor:(a) One Coat |
| 27 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat)a) Normal Acrylic Emulsion |
| 28 | White washing including cleaning and smoothening surface thoroughly.All floors :(c) Three coats (on new works only). |
| 29 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc |
| 30 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 31 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. |
| 32 | B) UPVC Fittings:a) Plain Tee(ii) 110 mm. Dia |
| 33 | d) Shoe(ii) 110 mm. Dia. |
| 34 | Supplying best Indian sheet glass panes set in putty (as per I.Sspecification) and fitted and fixed with teak wood beads and nailscomplete. (In all floors for internal wall & upto 6 m height for externalwall)(ii) 4 mm thick |
| 35 | ELECTRICAL WORK:Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC |
| 36 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. (i) On Board |
| 37 | Supplying and fixing PVC Rigid Conduit \"FR\" [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. (a) 20mm size |
| 38 | 25mm size |
| 39 | Distribution wiring 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 40 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 41 | Supplying & Fixing solderless copper sockets by crimping of copper wires.1.5 sq mm |
| 42 | 2.5 sqmm |
| 43 | 4 sqmm |
| 44 | 6 sqmm |
| 45 | Supply & delivery of 1.1KV Grade 3 crore 10 Sq. Mm multy stranded alluminium Armoured cable, [Make-Gloster/Havells/Polycab/KEI] |
| 46 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 3 core 10 sqmm cable |
| 47 | (b) Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 48 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish inclu. Following size GI[Hot Dip] Wire as Earthing as per GS. (i) From 2.5 sqmm to 35 sqmm inclu. earthing attachement in 2 x 10 SWG GI [Hot Dip]wire |
| 49 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 50 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. (b) 32 mm dia |
| 51 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 4 Way |
| 52 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 53 | upply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required |
| 54 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. (b)6 Module |
| 55 | (a)Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 56 | (a) Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 57 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+8 way [Legrand] |
| 58 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/Schneider/Siemens/ Crabtree/L&T] as per direction of EIC. 40A DP |
| 59 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per GS [Make-Legrand/Schneider/Siemens/ Crabtree/L&T] as per direction of EIC. 6-32 SP |
| 60 | Supply and delivery of twin Industrial type LED luminatries with aluminium extrusion heat sink incl. Supply of 2nos. 18W LED Tube with LED Batten. [Make-SURYA, 2x T-8 Cat no. SLE TL DS 18 PAL EXT & SUB 218 T8 LED or equivalent Magik/ Philips/ CG/Bajaj/Wipro/Havells as approved by EIC]. |
| 61 | Supply & fixing of 240V, 30W Floodlight is a compact LED Floodlight with system luminious efficacy of 110m/w, proctected to IP66, with front toughened glass, with discrete high lumen LED complete with all accessories. [Make-SURYA, Cat no. SLE FL 30w IP66 LMS NEO-N or equivalent Model Philips/Wipro on celling as per direction of EIC]. (With 2 years warranty) |
| 62 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 63 | Supply & fixing MS FAN clam of two piece type for RC celling as approved specification as per GS. |
| 64 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. Making necy. connections etc. |
| 65 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 66 | Supply of 1200mm sweep celling fan complete with blades, canopy, fork, rubber bush etc. as per GS (Make-Crompton High speed of equivalant model or orient, Usha as approved by EIC] (With 2 years warranty) |
| 67 | Add GST 18% over the Sub-Total upto item No. 66 |
| 68 | Labour Welfare CESS 1% over the Sub-Total upto item No. 67 Please Enable Macros to View BoQ information Compatibility Report for V3_BOQ_Percentage_Template.xls Run on 5/11/2015 12:49 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Significant loss of functionality # of occurrences Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 \"BoQ1\"!A1:II34 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 15.0 |