Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Four Way Cassette type VRF Indoor UnitsSupply, installation, testing and commissioning of following minimu capacity 4- way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh airprovision compatible for Remote2.0 TR Four Way Cassette type AC Unit |
| 2 | 3.2 TR Four Way Cassette type AC Unit |
| 3 | 4.0 TR Four Way Cassette type AC Unit |
| 4 | 24.0 HP Capacity |
| 5 | 26.0 HP Capacity |
| 6 | VRF System Remote ControllerSupply / Installation / Testing and Commissioning of Cordlesss remotes for VRF indoor units( For Hi Wall Type IDUs ) |
| 7 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 8 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 9 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 10 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 11 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 12 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 13 | 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thickinsulation |
| 14 | 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thickinsulation |
| 15 | Refrigerent Gas First Charge24.0 HP Capacity |
| 16 | 26.0 HP Capacity |
| 17 | Y JOINTS: Supply, installation, testing & commissioning of Ref Nut/Y-jointsbrass for indoor and outdoor units of suitable size as per requirement. As per specification/drawings and as directed by Engineer In Charge. |
| 18 | Supply and laying, testing & commissioning of following sizes of Copperconductor controlcables through PVC conduit on existing tray including fixing clamps & proper connections to equipments etc. complete as required. As per specification/drawings and as directed by Engineer In Charge.2CX 1.5 Sq.mm |
| 19 | Power & Communication Cabling For VRF SystemPower Cabling to individual Outdoor units with PVC conduits. ( From PowerPanel to VRF ODU ) |
| 20 | Communication Cable between Outdoor Units & Indoor Units with PVC conduits |
| 21 | Transportastion , Lifitng and Shifting at Site |
| 22 | Supply,instalation,estingnd Commissioning of canera Mounting,1 xNetwork Video Recorder (NVR) 2MP/ 4Channel/ H265+ compression/ 1SATA/ 2TB Storage Managed Switch, 1x3KVA Online 15min Battery Backup (Legrand/Vertiv), NetworkCable, Connectors, Outdoor Cubical Rack (IP66) and other Associate Accessories complete and inculuding CMC and AMC. |
| 23 | CIVIL WORKExcavation in foundation in ordinary soil, loam, clay or sand including lift upto 1.5 m & lead upto 30m Including filling watering & ramming of excavated earth into the trenches or into the space between the building & the sides of foundation trenches or in to the plinth removal & disposal of surplus earth as directed by the engineer in charge upto a distance of 30m from the foundation |
| 24 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. from the site of work & including watering, dressing etc. Rate includes cost of all materials, labour and T&P etc. required for proper completion of the work. (including royalty) |
| 25 | Cement concrete with 4 cm. (1½\") gauge approved stone, ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. |
| 26 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cementcontent of 300 kg /cum (All works upto plinth level ) |
| 27 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra Concrete of M25 grade with minimum cement content of 300 kg /cum (All works above plinth and upto floor V level) |
| 28 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra Concrete of M25 grade with minimum cement content of 300 kg /cum (All works above plinth and upto floor V level) |
| 29 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra Concrete of M25 grade with minimum cement content of 300 kg /cum (All works above plinth and upto floor V level) |
| 30 | First Class brick work in 1 : 4 cement & fine coarse sand mortar in foundation & plinth including supply of all materials labour & tools and plants etc. required for proper completion of the work. |
| 31 | First Class brick work in 1 : 4 cement & fine coarse sand mortar in super structure, including necessary cutting and moulding of bricks as required and also including honey comb brick work. Thickness of wall not to be less than 1.5 brick thick. |
| 32 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 33 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 34 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) : Flush / Ruled/ Struck or weathered pointing |
| 35 | 15mm thick cement plaster with cement mortar in proportion of 1:4 cement and coarse sand. |
| 36 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick- work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage and over lapping & hooks |
| 37 | Providing and laying rectified glazed ceramic floor tiles of size 600x600 mm, of 1st quality conforming to IS:15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thik cement mortar 1:4, jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 38 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 39 | Finishing walls with water proof cement paint of aprooved make and quality on new work with two coats to give an even shade, including supply of all material, labour and T&P etc. required for proper compilation of the work. |
| 40 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 41 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 42 | Providing and fixing Ist quality ceramic glazedtiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 43 | Excavation in foundation in ordinary soil, loam, clay or sand including lift upto 1.5 m & lead upto 30m Including filling watering & ramming of excavated earth into the trenches or into the space between the building & the sides of foundation trenches or in to the plinth removal & disposal of surplus earth as directed by the engineer in charge upto a distance of 30m from the foundation |
| 44 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. from the site of work & including watering, dressing etc. Rate includes cost of all materials, labour and T&P etc. required for proper completion of the work. (including royalty) |
| 45 | Cement concrete with 4 cm. (1½\") gauge approved stone, ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. |
| 46 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cementcontent of 300 kg /cum (All works upto plinth level ) |
| 47 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra Concrete of M25 grade with minimum cement content of 300 kg /cum (All works above plinth and upto floor V level) |
| 48 | First Class brick work in 1 : 4 cement & fine coarse sand mortar in foundation & plinth including supply of all materials labour & tools and plants etc. required for proper completion of the work. |
| 49 | First Class brick work in 1 : 4 cement & fine coarse sand mortar in super structure, including necessary cutting and moulding of bricks as required and also including honey comb brick work. Thickness of wall not to be less than 1.5 brick thick. |
| 50 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 51 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 52 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) : Flush / Ruled/ Struck or weathered pointing |
| 53 | 15mm thick cement plaster with cement mortar in proportion of 1:4 cement and coarse sand. |
| 54 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick- work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage and over lapping & hooks |
| 55 | Providing and laying rectified glazed ceramic floor tiles of size 600x600 mm, of 1st quality conforming to IS:15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thik cement mortar 1:4, jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 56 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 57 | Finishing walls with water proof cement paint of aprooved make and quality on new work with two coats to give an even shade, including supply of all material, labour and T&P etc. required for proper compilation of the work. |
| 58 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 59 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 60 | Providing and fixing Ist quality ceramic glazedtiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 61 | DOOR/ WINDOWS/FALSE CEILINGProviding and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWDSpecification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mmor even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof theEngineer-in-Charge. With 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G-21 |
| 62 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Teesections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 63 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 64 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 65 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 66 | Fixed window / ventilator with mullion / transom.Using R1 series with frame (33mm & above ) x (35mm & above) & mullion (33mm & above) x (50mm & above). (Height upto 0.90 metre) |
| 67 | DOOR/ WINDOWS/FALSE CEILINGProviding and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWDSpecification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mmor even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof theEngineer-in-Charge. With 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G-21 |
| 68 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Teesections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 69 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 70 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 71 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 72 | Fixed window / ventilator with mullion / transom.Using R1 series with frame (33mm & above ) x (35mm & above) & mullion (33mm & above) x (50mm & above). (Height upto 0.90 metre) |
| 73 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 74 | Supply & fixing of power plug with 15 amp 250 volts flush type switch & 5 pin 15 amp 250 volts flush type socket in suitable M.S. box of 175 mm * 100mm * 50 mm size with bakelite sheet cover 3 mm thick fixed with brass machine screws & washers complete in all respect. |
| 75 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 4.00 sq. mm. With 1 x 2.5 sq.mm. Earth wire In 20 mm dia conduit. |
| 76 | 2x 6 sq. mm. With 1 x 4 sq.mm. Earth wire In 25 mm dia conduit. |
| 77 | 2 x 16 sq. mm. With 1 x 10 sq.mm. Earth wire In 32 mm dia conduit. |
| 78 | Supply and laying of heavy duty PVC conduit complete with bend and other accessories as required and 14 S.W.G. fish steel wire etc. in slab alongwith reinforcement before concreting and plastering complete in all respects.20 mm dia. PVc conduit |
| 79 | 25 mm dia. PVC conduit |
| 80 | S/F of surface / flush mounting TPN Distribution board without MCB complete in all respects as directed at site .12 WAYS Cat(A) |
| 81 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve Cat(A) |
| 82 | Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per direction and satisfaction of engineer-in-charge.40 Amp 2 Pole |
| 83 | Supply & burrying of safe earthing electrode T-39 (Hot Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixtuer (CCM) Having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of rataining capacity along with 30cm squre C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 GI, strip will be extra)Make:as approved in U.P.P.W.D., & C.P.R.I. Certified |
| 84 | Supply & Laying of 25mm x 3mm G. I. strip from earth electrode directly in the ground as required complete in all respect. |
| 85 | S/F of single light wall bracket on matching M.D.F.E.G. board base etc. complete in all respects.Category AAA |
| 86 | Supply & fixing of Recess/Surface/Pendent mounting round 6 to 8 Watt LED down lighter having powder coated die cast Aluminium housing with heat sink, diffuser/reflecter, and driver set complete in all respect. Category AAA |
| 87 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 88 | Supply and Fixing of LED Tube Light with batten suitable for up to 2X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 89 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 90 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. |
| 91 | Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. |
| 92 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 93 | S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I rules. |
| 94 | Supply & Erection of factory fabricate & wired metal clad dust and vernim proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB\"s (Four pole 36 KA with thermal magnetic release) switches complete and instrument chamber etc. completed in all respects. The instrument chamber shall be seprated and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F, KW etc) in each phase with touch type selector switches for different readings , intrument fuses, current transformer etc. the panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB\"s shall be completed with suitable cable and boxes, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have Ammeter.The panel board shall be fabricated with CRCA shee with a minimum thicness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B only.Incoming 200Amp. MCCB-1No. Outgoing 100 Amp MCCB-1 No & 63 Amp MCCB-3Nos |
| 95 | Supply & erection of AC 1200mm Sweep, 220/240 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-BEE-5 Star rated |
| 96 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX300 mm sweep |
| 97 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 98 | Supply & fixing of power plug with 15 amp 250 volts flush type switch & 5 pin 15 amp 250 volts flush type socket in suitable M.S. box of 175 mm * 100mm * 50 mm size with bakelite sheet cover 3 mm thick fixed with brass machine screws & washers complete in all respect. |
| 99 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 4.00 sq. mm. With 1 x 2.5 sq.mm. Earth wire In 20 mm dia conduit. |
| 100 | 2x 6 sq. mm. With 1 x 4 sq.mm. Earth wire In 25 mm dia conduit. |
| 101 | 2 x 16 sq. mm. With 1 x 10 sq.mm. Earth wire In 32 mm dia conduit. |
| 102 | Supply and laying of heavy duty PVC conduit complete with bend and other accessories as required and 14 S.W.G. fish steel wire etc. in slab alongwith reinforcement before concreting and plastering complete in all respects.20 mm dia. PVc conduit |
| 103 | 25 mm dia. PVC conduit |
| 104 | S/F of surface / flush mounting TPN Distribution board without MCB complete in all respects as directed at site .12 WAYS Cat(A) |
| 105 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve Cat(A) |
| 106 | Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per direction and satisfaction of engineer-in-charge.40 Amp 2 Pole |
| 107 | Supply & burrying of safe earthing electrode T-39 (Hot Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixtuer (CCM) Having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of rataining capacity along with 30cm squre C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 GI, strip will be extra)Make:as approved in U.P.P.W.D., & C.P.R.I. Certified |
| 108 | Supply & Laying of 25mm x 3mm G. I. strip from earth electrode directly in the ground as required complete in all respect. |
| 109 | S/F of single light wall bracket on matching M.D.F.E.G. board base etc. complete in all respects.Category AAA |
| 110 | Supply & fixing of Recess/Surface/Pendent mounting round 6 to 8 Watt LED down lighter having powder coated die cast Aluminium housing with heat sink, diffuser/reflecter, and driver set complete in all respect. Category AAA |
| 111 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 112 | Supply and Fixing of LED Tube Light with batten suitable for up to 2X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 113 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 114 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. |
| 115 | Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. |
| 116 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 117 | S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I rules. |
| 118 | Supply & Erection of factory fabricate & wired metal clad dust and vernim proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB\"s (Four pole 36 KA with thermal magnetic release) switches complete and instrument chamber etc. completed in all respects. The instrument chamber shall be seprated and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F, KW etc) in each phase with touch type selector switches for different readings , intrument fuses, current transformer etc. the panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB\"s shall be completed with suitable cable and boxes, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have Ammeter.The panel board shall be fabricated with CRCA shee with a minimum thicness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B only.Incoming 200Amp. MCCB-1No. Outgoing 100 Amp MCCB-1 No & 63 Amp MCCB-3Nos |
| 119 | Supply & erection of AC 1200mm Sweep, 220/240 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-BEE-5 Star rated |
| 120 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX300 mm sweep |
| 121 | FIRE External fire hydrant landing valve with stand post |
| 122 | 100 mm dia MS heavy-duty external ring main |
| 123 | 100 mm dia MS vertical riser |
| 124 | Internal hydrant landing valve with hose cabinet |
| 125 | 63 mm dia hose reel |
| 126 | 65 mm dia MS branch piping |
| 127 | Fire stopping for riser |
| 128 | Automatic sprinkler heads |
| 129 | 32 mm MS branch lines |
| 130 | 65 mm MS header |
| 131 | Sprinkler test & drain assembly |
| 132 | Flexible sprinkler drops |
| 133 | Addressable fire alarm control panel |
| 134 | Smoke/heat detectors |
| 135 | Manual call points |
| 136 | Hooters with flasher |
| 137 | FRLS fire alarm cable |
| 138 | Response indicators |
| 139 | Programming & integration |
| 140 | 6 kg ABC extinguishers |
| 141 | 4.5 kg CO2 extinguishers |
| 142 | 9 L foam/water extinguishers |
| 143 | Commissioning of extinguishers |
| 144 | Fire water storage tank |
| 145 | Electric fire pump |
| 146 | Diesel fire pump |
| 147 | Jockey pump |
| 148 | Pump control panel |
| 149 | Suction & delivery piping |
| 150 | Power & control cabling |
| 151 | Earthing works |
| 152 | Photoluminescent exit signs |
| 153 | LED exit sign boards |
| 154 | Floor path marking |
| 155 | Fire escape route plans |
| 156 | Training session |
| 157 | Hydraulic testing |
| 158 | System commissioning |
| 159 | As-built drawings & documentation |
| 160 | Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989Providing and fixing soil, waste and vent pipes :100 mm dia |
| 161 | Providing and fixing collar :100 mmSand cast iron S&S as per IS - 3989 |
| 162 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaSand cast iron S&S as per IS - 3989 |
| 163 | Providing and fixing heel rest sanitary bendSand cast iron S&S as per IS - 3989100mm die |
| 164 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast Iron/Cast Iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 100mm dia pipe |
| 165 | Providing and fixing 100 mm dia C.P. grating of approved quality and colour |
| 166 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100mm |
| 167 | Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989Providing and fixing soil, waste and vent pipes :100 mm dia |
| 168 | Providing and fixing collar :100 mmSand cast iron S&S as per IS - 3989 |
| 169 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaSand cast iron S&S as per IS - 3989 |
| 170 | Providing and fixing heel rest sanitary bendSand cast iron S&S as per IS - 3989100mm die |
| 171 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast Iron/Cast Iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 100mm dia pipe |
| 172 | Providing and fixing 100 mm dia C.P. grating of approved quality and colour |
| 173 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100mm |
| 174 | ProjectorSITC of DLP Laser Phosphor projector with Laser light source having 20,000 hrs life or more, of 10000 ISO Lumens or more, WUXGA resolution(1920 x 1200) and Contrast ratio(dynamic) 20,000:1 or better. Inbuilt capability of Vertical & Horizontal Keystone correction, Digital Zoom. The projector should have sealed light engine for dust protection. The projector should be Full HD 3D ready. Inputs: 1 x VGA in/out, 2 x HDMI, 1 x HDBaseT, 3G-SDI in/out Controls: 3D sync in/out, RS232, Audio in/out stereo. Control: Crestron RoomView, AMX & RS232 with appropriate Lens(Make:Barco/Digital Projection/Chiristie/Vivetek or Equivalent) |
| 175 | Assembly and mounting of projector as per site plan .brackets and tilt/pan arrangement systems for projection layout. |
| 176 | Media Server complete with software including Lifetime license for blending/ mapping geometry correction, edge blending, color correction and 2D/3D mapping and hardware with following specs or better: The display server should support 5120 x 2880px resolution. It should have 32GB RAM, i7 Processor, min. 1TB NVME Gen 4 storage, 1GBP/S Ethernet and 4 x USB 3.2 ports, rack rail mountable chassis, with Integrated Graphic Card with EDID File Save function having min. 8GB. It should be preloaded with Windows 10. Approved makes: Dataton/ Vioso/ Asus |
| 177 | SITC of Main show Control Server and hardware with accessories in Rack mounted media control server should be in 4U with built-in hardware for 2D, 3D mapping, animation as per following details:-The server should have 4 DP 1.4v outputs with each channel supporting 4K. The server should have 1 X 10 GBP/S ethernet port with 2 USB3 ports.It shall comprise on Intel Core i7 Series Processor and should follow BIS Certification, norms with following minimum specifications. 4096X2160 Resolution @60hz max , 16 GB RAM system memory, Minimum 2TB SSD storage, Dedicated 6GB GPU, Audio Jack 3.5mm for stereo output.(Make: HP/Dell/Asus or Customized) |
| 178 | SITC of edge blending mapping software, controlling multiple outputs like video, lights and unlimited audio and sequences to be loaded on Show control Server etc complete as required.(Make: Watchout/D3/VIOSO/7th Sense or Equivalent) |
| 179 | Optical Fibre Signal SystemSITC of Combines copper and fibre optic cable for a hybrid, long distance HDMI® connectivity solutionSupports resolutions up to 4K@120Hz, 8K@60Hz as well as both static and dynamic HDR formats including Dolby Vision & HDR10+Ultra High-Speed HDMI® certified with support for HDMI features including VRR and eARC |
| 180 | LightsSITC of 40W RGBL Source Wash Light with the Following Specification : Max Power - 40W, Voltage - AC100~240V, Minimum Light efficiency (lm/W) > 45 lm/w, Lumen/Kg > 1000 lm/kg, Minimum Lumen (Full Colour On) > 1800 lm, Minimum Lumen (RED) > 670 lm, Minimum Lumen (Green) > 1170 lm, Minimum Lumen (Blue) > 250 lm, Standard Optical System -12°/30°/45°/60°/12*50°/15*50°, Dimming - 24Bit, CCT - 1800K-10000K with 14 In-Built Presets, Fast Colour Pickup - 24 In-Built Presets, Impact Projection - IK10, Ingress Protection - IP67, Protocol - DMX + RDMMake - Creative Illumination / Arctik / LT/ Jaquar/ Panasonic/ LBT / Cameo / ROXX lighting or Equivalent |
| 181 | SITC of 60W RGBL Source Linear Graze Light with the Following Specification : Max Power - 60W, Voltage - AC100~240V, Minimum Light efficiency (lm/W) > 67 lm/w, Lumen/Kg > 1870 lm/kg, Minimum Lm/M (Full Colour On) > 6100 lm/M, Minimum Lumen (Full Colour On) > 4100 lm, Minimum Lumen (RED) > 2500 lm, Minimum Lumen (Green) > 4100 lm, Minimum Lumen (Blue) > 950 lm, Standard Optical System -15°/25°/30°/60°/10*60°/15*30°/60*10°/40*15°, Dimming - 24Bit, CCT - 1800K-10000K with 14 In-Built Presets, Fast Colour Pickup - 24 In-Built Presets, Fixture Length - 666mm / 2Ft, Impact Projection - IK10, Ingress Protection - IP67, Protocol - DMX + RDM, Make - Creative Illumination / Arctik / LT/ Jaquar/ Panasonic/ LBT / Cameo / ROXX lighting |
| 182 | SITC of Ethernet to DMX/RDM gateway With 2 Universes of bi-directional DMX to standard DMX512-A conversion and ArtRDM support and additional In-Built Overdrive Mode for DMX500K support. The gateway should have Daisy-chain capability to expand your network. The gateway should support HTP/LTP merging for DMX sources And Should be capable of Configuring DMX output refresh rate. The hardware should accept sACN Sync as well as ArtSync to fully synchronize Art-Net data for all output ports. The gateway should have Max. refresh rate > 40FPS, Network speed = 10/100Base-T And Should Support Power over Ethernet IEEE 802.3af. The Hardware should be in Complaince with RCM (Aus/NZ), CE / WEEE (EU), UKCA (UK), FCC (USA). Make - Arctik / Cameo /Claypacky / Avolite / Enttec/ Madrix / Creative Illumination / LBT or Equivalent |
| 183 | SITC of 6-port, DMX/RDM isolated splitter with 7-24v DC power input range and removable terminal plugs for simple wiring. The Device should housed within a compact, electrically-insulated form factor with flexible mounting options. The Device should have 1500V Opto-isolation between each DMX port to protect against stray voltages on the DMX line and should support Support for DMX512-A and ANSI E1.20 RDM.. Make - Arctik / Cameo /Claypacky / Avolite / Enttec/ Madrix / Creative Illumination / LBT |
| 184 | SITC of 60W RGBL Source Wash Underwater Light with the Following Specification : Max Power - 40W, Voltage - AC100~240V, Minimum Light efficiency (lm/W) > 45 lm/w, Lumen/Kg > 1000 lm/kg, Minimum Lumen (Full Colour On) > 1800 lm, Minimum Lumen (RED) > 670 lm, Minimum Lumen (Green) > 1170 lm, Minimum Lumen (Blue) > 250 lm, Standard Optical System -12°/30°/45°/60°/12*50°/15*50°, Dimming - 24Bit, CCT - 1800K-10000K with 14 In-Built Presets, Fast Colour Pickup - 24 In-Built Presets, Impact Projection - IK10, Ingress Protection - IP67, Protocol - DMX + RDMMake - Creative Illumination / Arctik / LT/ Jaquar/ Panasonic/ LBT / Cameo / ROXX lighting or Equivalent |
| 185 | Audio SystemSITC of Ceiling + Pendant speaker system designed for top-tier audio performance and seamless aesthetic integration. Featuring a sturdy steel enclosure and a polypropylene front. The Speaker should comply the following Specification : Frequency Range (-10 dB) - 75 Hz – 20 kHz. Nominal Impedance - 8 ohms. Conical Coverage - 125º. Transformer Taps 70 V - 8 Ω / 5 W / 10 W / 15 W. Transformer Taps 100 V - 8 Ω / 10 W / 20 W / 30 W. RMS Power Handling - 50 W. Peak Power Handling - 200 W. On-axis Sensitivity 1W/1 m - 89 dB SPL. Maximum Peak SPL at 1 m - 12 dB. Audio Input Connector - 4-way Phoenix 3.8 mm. Enclosure Construction - Steel. Enclosure Geometry - Round. Cut Out Diameter - 185 mm (7,3 in)Make : VAL/DAS Audio/ Tannoy/Adamson/LD System /D&B Audiotechnic/Martin Audio/Amplifyx or Equivalent. |
| 186 | Supply of 12\" Two-way Speaker with one 1.25-inch HF titanium compression driver having Frequency Response(-3dB):- 62Hz-20KHz; Frequency Range (-10dB):- 50Hz-20KHz, Axial Sensitivity ≥ 97 dB & Long Term Power Handling of ≤ 500W (at a Nominal Impedance of 8Ohms). The Loudspeaker should have a Max. SPL of >129 dB.The Sound Dispersion should be at least 90˚ x 50˚ |
| 187 | Supply of 18\" Subwoofer with a Frequency Response(-3dB):- 51Hz-160Hz; Frequency Range (-10dB):- 45Hz-200Hz ; Axial Sensitivity > 99dB & Long Term Power Handling of ≤ 500W (at a Nominal Impedance of 8 Ω). The Loudspeaker should have a Max. SPL of >131dB |
| 188 | SITC of Accessory for Converting the Above mentioned Speaker into a Pendant System. Make : VAL/DAS Audio/ Tannoy/Adamson/LD System /D&B Audiotechnic/Martin Audio / Amplifiyx or Equivalent. |
| 189 | SITC of multi-purpose installation Amplifiers featuring a built in DSP with matrix routing, Crossover settings, EQ, Limiters and ability to store and load speaker presets. The amplifiers have built in Wireless-Access-Point (WAP) for the simple connection and coonfiguration via WiFi. The Product should be with the following Minimum Specification : Channels 4 x Lo-Z / 2 x Hi-Z. Output power @ 2Ω 4 x 500 W (SE) - (BTL). Output power @ 4Ω 4 x 500 W (SE) 2 x 1000 W (BTL). Output power @ 8Ω 4 x 250 W (SE) 2 x 1000 W (BTL). Output power @ 70V2 x 1000 W BTL . Output power @ 100V 2 x 1000 W BTL . Power Consumption 700 W . Output Circuitry UMAC™ Class D - full bandwidth PWM modulator with ultra-low distortion. Output Voltage 500.X Variants: 45 Vrms (S.E) - 90 Vrms (BTL) - 70/100V (Hi-Z), 800.X Variants: 55 Vrms (S.E) - 110 Vrms (BTL) -70/100V (Hi-Z). Signal To Noise-Ratio > 108 dB (A-weighted, 20 Hz – 20 kHz, 8 Ω load). THD+N (typical) < 0.05% (20 Hz – 20 kHz, 8 Ω load, 3 dB below rated power). Frequency Response 20 Hz – 20 kHz (+/- 0.5 dB, 8 Ω load, 3 dB below rated power) Protection Circuits Short circuit -, DC -, Undervoltage -, Temperature - and Overload protection Power Supply UREC™ universal mains switch mode power supply with Power Factor Correction (PFC) and standby converter Operating Temperature 0 – 40 C.Operating Voltage/Frequency Universal Mains, 100 V – 240 V, 50 Hz – 60 Hz Standby Consumption <0.5 .Accessories Rack Mounts (Included).Power Ratings 1 % THD @ 120 Vac and 230 Vac Make : VAL/DAS Audio/Tannoy/Adamson/LD System/D&B Audiotechnic/Martin Audio / Amplifiyx / Lab Gruppen or Equivalent. |
| 190 | SITC of Wall-mounted Networked / PoE Controller With the follwing features, Connect up to 8 x Wall-S1 per PowerZoneTM Connect amplifier, Allocate any Wall-S1 to any sound zone in the PowerZoneTM Control web app, Easily change source or manage volume in a zone – with pre-set minimum and maximum levels, PoE for easy network pairing, real-time device syncing with system and controller power supply, PIN code protection for both basic and advanced access, including system shutdown when leaving a location Intuitive menu for easy installation and system set-up – also easy handover to users, Customisable screen and backlight allowing brightness and colour control, Built high-performance polymer material with a touch-friendly matte finish and concealed screws Available in standard white RAL9003 and black RAL9005. Works with PowerZoneTM Connect Amplifiers.(Approved Make : LD Systems / DAS Audio / Tannoy / Amplifyx / Adamson or Equivalent) |
| 191 | SITC of Wall mount brackets for Above mentioned Speakers |
| 192 | SITC of multi-purpose installation Amplifiers featuring a built in DSP withmatrix routing, Crossover settings, EQ, Limiters and ability to store and load speaker presets. The amplifiers have built in Wireless-Access-Point (WAP) for the simple connection andconfiguration via WiFi. The Product should be with the following Minimum Specification :Channels 4 x Lo-Z / 2 x Hi-Z Output power @ 2Ω 4 x 500 W (SE) - (BTL)Output power @ 4Ω 4 x 500 W (SE)2 x 1000 W (BTL) Output power @ 8Ω 4 x 250 W (SE)2 x 1000 W (BTL) Output power @ 70V 2 x 1000 W BTL Output power @ 100V 2 x 1000 W BTL Power Consumption 700 W Output Circuitry UMAC™ Class D - full bandwidth PWM modulator with ultra-low distortionOutput Voltage 500.X Variants: 45 Vrms (S.E) - 90 Vrms (BTL) - 70/100V (Hi-Z), 800.X Variants: 55 Vrms (S.E) - 110 Vrms (BTL) - 70/100V (Hi-Z) Signal To Noise-Ratio > 108 dB (A-weighted, 20 Hz – 20 kHz, 8 Ω load)THD+N (typical) < 0.05% (20 Hz – 20 kHz, 8 Ω load, 3 dB below rated power)Frequency Response 20 Hz – 20 kHz (+/- 0.5 dB, 8 Ω load, 3 dB below rated power)Protection Circuits Short circuit -, DC -, Undervoltage -, Temperature - and Overload protectionPower Supply UREC™ universal mains switch mode power supply with Power Factor Correction (PFC) and standby converterOperating Temperature 0 – 40 COperating Voltage/Frequency Universal Mains, 100 V – 240 V, 50 Hz – 60 HzStandby Consumption <0.5 WAccessories Rack Mounts (Included)Power Ratings 1 % THD @ 120 Vac and 230 Vac Make : VAL/DAS Audio/Tannoy/Adamson/LD System/D&B Audiotechnic/Martin Audio / Amplifiyx / Lab Gruppen or Equivalent. |
| 193 | control Room Cabling And MiscSITC of UTP 4 pair CAT 6 A LAN Cable in the existing surface/recessed steel/ PVC conduit as required. 1 run of cable |
| 194 | SITC following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness Make : Customized. |
| 195 | SITC testing and commissioning of 19\" Equipment Rack of 42U size with proper connections etc complete as required. Make : Customized. |
| 196 | SITC of 8-Port 10GBPS RJ45 Ethernet Switch, Each port is capable of sending and receiving data at 1-10 Gbps transfer speed. Make: D-Link / Cisco / TP-Link. |
| 197 | SITC of 24-Port 10GBPS RJ45 Ethernet Switch, Each port capable to sending and receiving data at 100-1000 mbps transfer speed. Make: D-Link / Cisco / TP-Link. |
| 198 | SITC of Dp to HDMI adaptor support 4K@60 resolution Make : Bluerigger /Cable Creation or Equivalent |
| 199 | SITC of 27\" Full HD Monitor, support DP and HDMI Input make: LG/ Samsung/ Dell |
| 200 | SITC ofMultimedia Keyboard Mouse WirelessMake: Dell/ Logitech/ HP |
| 201 | SITC of Flexible DMX512 Lighting Control Cable, 4 Conductor 24 AWG (7x32) stranded tinned copper, Foam PE insulation, foil shield plus 90% TC braid with 24 AWG stranded TC drain wire, all weather TPE jacket. (Dlink/Belden/Molex/Polycab/ Rellison) |
| 202 | SITC of 2 x 2.5 sq mm Copper Speaker Cable in in the existing surface/ recessed steel/ PVC conduit of specified make, complete with proper connections etc complete as required. (Make: Krystal/Finolex/Belden/ Rellison/Polycab ) |
| 203 | SITC of 2 x 4 sq mm Copper Speaker Cable in in the existing surface/ recessed steel/ PVC conduit of specified make, complete with proper connections etc complete as required. (Make: Krystal/Finolex/Belden/ Rellison/Polycab ) |
| 204 | SITC of 3CX2.5 Sqmm Cu PVC Felexible Cable Make : Havells/Polycab/Finolex or Equivalent. |
| 205 | SITC of 3CX4 Sqmm CU Flexi Cable Make: Havells/Polycab/Finolex or Equivalent. |
| 206 | SITC of Dual Band Wifi Access Point, support 2x ethernet port for loop throw signal transfer Make : TP-LINK/ D-link/ Cisco |
| 207 | Supply installation testing and commissioning of 60 KVA UPS with min 15 Minutes Backup Make: Microtek/ Eaton/ Vertiv/ APS or Equivalent. |
| 208 | SITC of 11\" Touch Panel with Minimum 3GB RAM and 64GB Internal Storage, IOS 15 or Android 12 or better.Make: Apple / Samsung / Lenovo/ Equivalent |
| 209 | Interactive Panel Size - 55\", with thin client, Type Technology - Backlit D- LED (IPS Panel), Brightness - 400 cd/m², Typical Contrast Ratio - 1200:1 , Dynamic Contrast Ratio - 30000:1, Native Resolution - 4K Ultra-HD (3840 x 2160) , Viewing Angle (H/V) - 178ᴼ/178ᴼ, Aspect Ratio - 16:9, Refresh Rate (Hz) - 60 Hz, Estimated Life Time - 50,000 Hours (Typical), Display Color (BIT) - 1.07 Billion (10-bit), Installation Orientation - Landscape, Response Time - 8 ms, Anti-Glare - Anti Glare Coating, Bonding - Zero Optical Bonding, Technology - Infrared Touch, Annotation - Supported, Touch - 20 Points, Passive Pen - ±1mm, Touch - ±1mm, Touch Resolution - 32,768 x 32,768, Surface Protection - Thick Toughened Glass (Level 7H on Mohs scale of Mineral Hardness), Touch Tools - Finger, Stylus, Glove, Opaque Objects, Simultaneous Writing, Pen, Touch, Palm Erase - Yes, Writing Stylus/Pen Location - Magnetic Mounting on IFPD Panel Front, System Version - Androidᵀᴹv13.0, Browser - Yes, Office - Yes, CPU Quad-core, Internal Storage - 32 GB, RAM - 4GB, Inputs Side Panel - 1 x Mini AV(3.5 mm mini jack, 2 x HDMI 2.0(60 Hz/4K), HDMIv2.0 (ARC) x1, Inputs Front Panel - 1 x HDMI 2.0(60 Hz/4K), Outputs Side Panel - 1 x HDMI-Out, 1 x SPDIF-Out, 1 x Earphone Out (Stereo Audio), USB Side Panel - 1 x USB-B(Touch), 1 x USB-A 2.0, 2 X USB-A 3.0 , USB Front Panel - 2 x USB-A 3.0, 1 x USB-B3.0, 1 x USB-C, Ethernet Side Panel - 1 x RJ45 Input, 1 x RJ45 Output, Control Side Panel - 1 x RS232C Control Signal Interface, Antenna Wi-Fi + Bluetooth - 3 + 1 (Wi-Fi 6, 802.11a/b/g/n/ac 2.4 GHz / 5GHz 2T/2R, Bluetooth 5.2), IR Receiver - Yes, Make : LG/Panasonic/Samsung/ or Equivalent. |
| 210 | Interactive Panel Size - 86\", Type Technology - Backlit D- LED (IPS Panel), Brightness - 400 cd/m², Typical Contrast Ratio - 1200:1 , Dynamic Contrast Ratio - 30000:1, Native Resolution - 4K Ultra-HD (3840 x 2160) , Viewing Angle (H/V) - 178ᴼ/178ᴼ, Aspect Ratio - 16:9, Refresh Rate (Hz) - 60 Hz, Estimated Life Time - 50,000 Hours (Typical), Display Color (BIT) - 1.07 Billion (10-bit), Installation Orientation - Landscape, Response Time - 8 ms, Anti- Glare - Anti Glare Coating, Bonding - Zero Optical Bonding, Technology - Infrared Touch, Annotation - Supported, Touch - 20 Points, Passive Pen - ±1mm, Touch - ±1mm, Touch Resolution - 32,768 x 32,768, Surface Protection - Thick Toughened Glass (Level 7H on Mohs scale of Mineral Hardness), Touch Tools - Finger, Stylus, Glove, Opaque Objects, Simultaneous Writing, Pen, Touch, Palm Erase - Yes, Writing Stylus/Pen Location - Magnetic Mounting on IFPD Panel Front, System Version - Androidᵀᴹv13.0, Browser - Yes, Office - Yes, CPU Quad-core, Internal Storage - 32 GB, RAM - 4GB, Inputs Side Panel - 1 x Mini AV(3.5 mm mini jack, 2 x HDMI2.0(60 Hz/4K), HDMIv2.0 (ARC) x1, Inputs Front Panel - 1 x HDMI 2.0(60 Hz/4K), Outputs Side Panel - 1 x HDMI-Out, 1 x SPDIF-Out, 1 x Earphone Out (Stereo Audio), USB Side Panel - 1 x USB-B(Touch), 1 x USB-A 2.0, 2 X USB-A 3.0 , USB Front Panel - 2 x USB-A 3.0, 1 x USB-B3.0, 1 x USB-C, Ethernet Side Panel - 1 x RJ45 Input, 1 x RJ45 Output, Control Side Panel - 1 x RS232C Control Signal Interface, Antenna Wi-Fi + Bluetooth - 3 + 1 (Wi-Fi) Make : LG/Panasonic/Samsung/ or Equivalent. |
| 211 | CONTENT CREATIONDesign Specification of Digital content: for 30 minutes show - Designing content iwith all the voice over, script writing, Story telling, with proper sound effects, background music in one Language.Treatment• Story Structuring, Scripting, Screenplay, Concept Stylization Story Boarding, Recording of VO (Voice Over) • Creation of Animatics • Surface Zone Divisions • Zone Allocation on POV • Production pipeline finalizations Pre-Production & Production • Camera Blocking • Animation • UV Unwrap on surface • Surface Mapping and Seeding • Scale Treatment • VFX Planning • Content compilation Post-Production • Final Scale Mapping on POV • Application of Lightning and Shaders • Lighting and Effect renders • Zone wise composting • Primary Render • VFx of POV Zones • Post VFx Render (Low Res) • Finalization |
| 212 | SITC of meticulously crafted scale model diorama depicting spacecraft, equipment, and surrounding environments etc. Constructed using advanced materials such as FRP, resin, and other specialized design elements. |
| 213 | Supply, integration of Av connectors with reputed make , Switch, socket,conduit, lighting control console, Projection Mapping for sucessfully running the ShowProgramming/ integration of show with content, effect etc. including cost of cueing, programming DMX based intelligent Luminaries and system integration etc. |
| 214 | Supply,Installation & Integration for control room of required size with Air-conditioning systemof appropriate capacity in Control room to maintain temperature for coolingof equipments 5 star BEE rated 2 ton or higher capacity split AC with inverter technology stabilizer free operation and all necessory requirements for show control. |
| 215 | Supply of Fire Extinguishers as per local( State) fire safety rules & regulations. |
| 216 | Supply , installation , testing & commissioning of electrical Distribution panel with proper earthing,( copper bas bar, reputed make MCB) for Av equipment, Rack,& other light as per calculation of load or as per Site condtion, asper direction incharge |
| 217 | SITC of Dynamic Exhibit - Complete Zone wise Exhibits • Space Rockets • Satellite • Rover (motorized) Other Geared automated roof controllers for moving exhibits up and down with controllers. (Sync Hardware & Software for triggering by Watchout not included currently.) |
| 218 | 3D Wall murals in FRP |
| 219 | Cladding work on walls with 12 mm WPC board / PLY board on GI metal structure |
| 220 | Cladding work on walls with Acoustic Panels on GI metal structure |
| 221 | Cabling for the entire setup including earthing as required |
| 222 | Lightweight MS fabrication with Tubular Section-Providing and fixing partitions/ wall lining work made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, with two coats of approved steel primer etc. |
| 223 | WPC Cladding -Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N(Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 224 | Carpet Tile Flooring -Providing & installtion of nylon based solution dyed carpet tiles or planks with 16/18 Oz quality, should pass smoke density test, UV treated, diementinally stable, Standard carpet made CRI Green label plus approved carpet with heavy duty performance as per approved design including marking of Universal Symbol of accesibility, complete in all respect including PVC backing below the carpet. Rates quoted should include cost of adhesives, fixing , cutting welding of carpet etc complete in all respects. Carpet shall be of Tile Type 50 x 50 cms or 100 cm x 25 cm. All carpet types shall be of same thickness (min. 16/18 oz / Sq mt). It shall be loop carpet or VLOC. Total thickness 6-8mm. PVC Backing for carpet shall be non-toxic fume producing, Should follow properties and must be able to pass all the related tests |
| 225 | Paint/ Putty-Finishing walls , including paint , putty, primer,with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail