| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 2 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 4 | Dismantling of wall and celling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness inlcuding cover fillets, complete all as specified and as directed. |
| 5 | M & L of 6 mm thick veneered decorative plywoode,grade 1 (with decorative face veneers on one faces) in ceiling, fixed with nails to timber frame work, complete all as specified and as directed. |
| 6 | M & L of 6 mm thick veneered decorative plywoode,grade 1 (with decorative face veneers on one faces) on wall, fixed with nails to timber frame work, complete all as specified and as directed. |
| 7 | M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails not exc 3 sqcm in section, complete all as specified and as directed. |
| 8 | M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails exc 13 sqcm & n.exc 25 Sqcm in section, complete all as specified and as directed. |
| 9 | M&L for dismantling2nd class softwood in scantling clean swan timber framed and fixed to the position, complete all as specified and as directed. |
| 10 | S&F2nd class softwood in scantling clean swan timber framed and fixed to the any position, complete all as specified and as directed. |
| 11 | Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed. |
| 12 | S&F Softwood 2nd class Clean sawn with butt joints eaves boards 20 mm thick, complete all as specified and as directed. |
| 13 | M&L Weather boarding, 25 mm thick, wrought both sides, V-jointed to give 20mm laps and fixed, complete all as specified and as directed. |
| 14 | Excavation in trenches in any type of soil, n exc 1.5 M wide and n exc 1.5 M deep for foundation, etc or for shafts, wells, manholes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil, complete all as specified and as directed. |
| 15 | Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm, complete all as specified and as directed. |
| 16 | Removing of excavated soil not exceeding 50m and depositing where directed at a level not exc 1.5 M above the starting point, complete all as specified and as directed. |
| 17 | M&L Plain Cement concrete Type D-2, 1:4:8 (40mm graded aggregate),in foundation, filling and mass concrete, complete all as specified and as directed. |
| 18 | M & L for brick work with sub class \"B\" bricks (old sizes) straight or curved on plan exceeding 6 mtr mean radius built in CM (1:6), complete all as specified and as directed. |
| 19 | S & F Mild steel TMT bars 10 mm dia and over, quality conforming to Grade 415 MPA cut to length , bent to shape required including cranking , bending and binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 20 | All as per item above but 5mm dia and above including 10mm dia in stirrups, complete all as specified and as directed. |
| 21 | M&L pre-cast reinforced cement concrete Type B-1, 1:2;4, (20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands etc, complete all as specified and as directed. |
| 22 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces ofbrick workor cement concrete surfaces including finishing to surfaces even and smooth without using extra cement, complete all as specified and as directed. |
| 23 | M & L For rendering 15 mm thick plastering on otherthan fair faces ofbrick work or stone masonry in CM (1:6) and rendering is to be finished even and smooth w/o using extra cement, complete all as specified and as directed. |
| 24 | M & L 75mm thick PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement, complete all as specified and as directed. |
| 25 | M&L for cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in subbase under floor, complete all as specified and as directed. |
| 26 | M&L for 25 mm thick PCC type B1 (1:2:4) using 20 mm graded aggregate as in slope correction under floor tile, complete all as specified and as directed. |
| 27 | M&Lnon skid coloured printed ceramic tile 7 to 8 mm thick(Square / rectangular)area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm,in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colur of tiles over 15 mm thick screed bed in CM (1:4), complete all as specified and as directed. |
| 28 | M & L for glazed ceramic tiles in vertical surface 450x300x10 mm thick colour and design (as approved) in vertical surfaceand jointed in neat cement slurry and pointed in whiter or colour cement to match the colour of tiles over 15 mm thick cement plaster using CM (1:4), complete all as specified and as directed. |
| 29 | Preparation of newly plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and as directed. |
| 30 | S&F 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed. |
| 31 | S&F Plain, framed,panelled shutters thickness 35 mm of 2nd class softwood,(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and as directed. |
| 32 | S&F 2nd class soft wood glazed and skeleton shutters 35 mm thick , open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and as directed. |
| 33 | S&F Glazed and skeleton shutters thickness 30 mm,(2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Sectionspecified 8 clause 8.24(b), complete all as specified and as directed. |
| 34 | S&F Door closer hydraulically regulated cost iron body designation No 1 universasl type suitable for door shuutters up to 700 mm in width and of weight not more than 35 kgs, complete all as specified and as directed. |
| 35 | S&F Aluminium anodised, barrel tower bolts 100 mm of extruded section and fixed, complete all as specified and as directed. |
| 36 | S&F Aluminium anodised, barrel tower bolts 150 mm of extruded section and fixed, complete all as specified and as directed. |
| 37 | S&F Aluminium alloy, anodised, sliding door bolt 200 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed. |
| 38 | S&F M S Butt hinges 100 mm medium weight, cold rolled mild steel and fixed, complete all as specified and as directed. |
| 39 | S&F M S Butt hinges 75 mm medium weight, cold rolled mild steel and fixed, complete all as specified and as directed. |
| 40 | S&F Aluminium handles 100 mm , cast type,anodised and fixed, complete all as specified and as directed. |
| 41 | S&F Aluminium handles 150 mm , cast type,anodised and fixed, complete all as specified and as directed. |
| 42 | S&F floor door stopper long 140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and as directed. |
| 43 | M&L two coats of synthetic enamel paint over and incl a coat of pink primer including preparation of surface on new wooden sruface over 10 cm width or girth, complete all as specified and as directed. |
| 44 | S&F Sheet glass thickness3.00 mm,ordinary quality and glazing with oil putty in square exceed 0.5 sqm in each pane, complete all as specified and as directed. |
| 45 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded agrregate) as insub base of floors, finished even and fair over well/rammed/compacted earth, complete all as specified and as directed. |
| 46 | M&L for providing and laying 60mm thick factorymade chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory ompaction by using plate vibrator, filling he joints with fine sand and cutting of paver block as per required size and attern, finishing and sweeping extra sand, complete all as specified and as directed. |
| 47 | S & F Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including screed bed 15mm thick comple in CM (1:4), complete all as specified and as directed. |
| 48 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar, complete all as specified and as directed. |
| 49 | M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) , complete all as specified and as directed. |
| 50 | M&L for preparation of new surfaces of walls and applying two coats of cement base paint, complete all as specified and as directed. |
| 51 | S&F in repair 2nd class softwood in scantling clean swan timber framed and fixed to the position including dismantling, complete all as specified and as directed. |
| 52 | Dismantling floor hearth wall tilling including cement mortar bedding, removing serviceable tiles to store and rubbish of the permishes, complete all as specified and as directed. |
| 53 | M&L20-25mm thickmachine cut kota stone slab flooring over 15mm thick cement screed base in cement mortar 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed. |
| 54 | M&L20-25mm thick machine cut kota stone slabin riser of steps, skirting, dado and pillar laid including 15mm thick rendering on stone masonry surfaces or surface other than fair face of brick-work or concrete surfaces on one side of lathing jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed. |
| 55 | Demolition of cement concrete (unreinforced) in any position andany thickness (below or above ground level), complete all as specified and as directed. |
| 56 | M&L for 6mm thick Asbestos cement building board fixed to existing framework incl dismantling of existing, complete all as specified and as directed. |
| 57 | M&L for Preparation ofun plastered surfaces of ceiling and applying two coat of white wash, complete all as specified and as directed. |
| 58 | M&L for Preparation ofun plastered surfaces of wall and applying two coat of white wash, complete all as specified and as directed. |
| 59 | Taking down chowkats or frames but with shutters (without taking off shutters from the frame) exceed 1.5 Sqm and not exceed 4.00 sqm, complete all as specified and as directed. |
| 60 | S&F 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed. |
| 61 | M&L for 2nd class 35mm thick Plain frame panelled shutter with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressuretreated, complete all as specified and as directed. |
| 62 | S&F Sheet glass thickness3.00 mm,ordinary quality and glazing with oil putty in square exceed 0.5 sqm in each pane, complete all as specified and as directed. |
| 63 | M&L Preparation of new wooden surface of any description and two coat of synthetic enamel paint, not otherwise descri-bed,over 10cm width or girth, complete all as specified and as directed. |
| 64 | M&L Preparation of old wooden surface of any description and two coat of synthetic enamel paint, not otherwise described,over 10cm width or girth incl complete removal, complete all as specified and as directed. |
| 65 | Aluminium anodised, barrel tower bolts 200 mm of extruded section and fixed, complete all as specified and as directed. |
| 66 | S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed. |
| 67 | Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed. |
| 68 | S&F Softwood 2nd class Clean sawn with butt joints eaves boards 20 mm thick, complete all as specified and as directed. |
| 69 | M&L Weather boarding, 25 mm thick, wrought both sides, V-jointed to give 20mm laps and fixed, complete all as specified and as directed. |
| 70 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. |
| 71 | M&Lfor point wiring for using 1.5Sqm nominal cross section area copper conductor multistandardPVC unsheathed, FRLS cable in and including using pvc casing caping not less than 25mm size and fitings including pvc boxwith suitable size of pvc sheet for top cover(ISI marked) fitted with chromium plated steel screws and washer and 1.5 Sqmmnominal cross section area multistandared copper conductor FRLS green pvc insulated unsheathed earth wire and conecting to earth dolly using color code as per IS including terminal boxes suitable for fixing socket and switches all as specified as directed by engineer in charge. |
| 72 | (a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 73 | (c)One 3 pin 5 Amp switch socket outlet on independent board |
| 74 | (d) One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 75 | M&Lfor point wiring for using 2.5 Sqm nominal cross section area copper conductor multistandardPVC unsheathed, FRLS cable in and including using pvc casing caping not less than 25mm size and fitings including pvc boxwith suitable size of pvc sheet for top cover(ISI marked) fitted with chromium plated steel screws and washer and 2.5 Sqmmnominal cross section area multistandared copper conductor FRLS green pvc insulated unsheathed earth wire and conecting to earth dolly using color code as per IS including terminal boxes suitable for fixing socket and switches all as specified as directed by engineer in charge. |
| 76 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. |
| 77 | S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed. |
| 78 | S&FSocket outlet 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and as directed. |
| 79 | S&FSocket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed. |
| 80 | S&F Switch socket combination 2 in1, 3 pin,5 and 15Amp flush type,universal complete all as specified and as directed. |
| 81 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 82 | S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed. |
| 83 | S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires,complete all as specified and asdirected. |
| 84 | S & F in repairs MCB, SPN 63 Amps 240 VoltsC curve, complete all as specified and as directed. |
| 85 | S&F in repairs Distribution Board, SPN 8 Way, Double door, complete all as specified and as directed. |
| 86 | S & F in repairs MCB,SPN 40 Amps 240 VoltsB curve, complete all as specified and as directed. |
| 87 | S & F MCB Single pole 6-32A Amps 240 Volts B Curve, complete all as specified and as directed. |
| 88 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep BEE 5 star rated with brushes direct connect motor, complete all as specified and as directed. |
| 89 | Supply and fixing LED lights fittings 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 90 | S&F LED light fitting 1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 91 | S&F in replacement LED Mirror Light 10 W, Decorative ultra slim square profile with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. suitable for surface mounting on a ceiling or wall, complete all as specified and as directed. |
| 92 | S&FLED bulb inverter type of capacity 9 watt (ISI marked) complete with all accessories base, complete all as specified and as directed. |
| 93 | M&L in repairs for Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc |
| 94 | Supply ,Laying ,connecting/ Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade withstranded aluminumconductor conforming to IS :7098, laid in trenches/ducts/fixed to wall /roofs/ poles all as specified of size2 Core 10 sq mm . including Taking outold unservicable cable from any space, complete all as specified and as directed. |
| 95 | Supply ,Laying ,connecting/ Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade withstranded aluminumconductor conforming to IS :7098, laid in trenches/ducts/fixed to wall /roofs/ poles all as specified of size2 Core 25 sq mm . including Taking outold unservicable cable from any space, complete all as specified and as directed. |
| 96 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable,complete all as specified and as directed. |
| 97 | M&L for Sub class \"B\" bricks laid dry width wise across the line of cable in treanchs as cable protection,complete all as specified and as directed. |
| 98 | S&F GI Tubing light grade 40mm dia with all fitting; laid in trenches,complete all as specified and as directed. |
| 99 | Note:- Schedule of credit Rs 1,06,886.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. |