Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M & L Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil. Complete all specified and directed by Engr-in-Charge. |
| 2 | Excavation over areas n.exc 1.50 m deep and getting out in soft/loose soil complete all as specified. |
| 3 | Removing excavated material to distance not exc50 metre and depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge |
| 4 | Returning, filling in, including spreading, levelling,watering and well ramming in layers not exc 25 cm thick with soil etc complete all as specified. |
| 5 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified. |
| 6 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as infoundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. |
| 7 | Use and removal of steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed. |
| 8 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as inColumns, pillars, piers, posts and struts complete all as specified. |
| 9 | Use and removal of steel formwork to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for rough finished surfaces of concrete complete all as specified and as directed. |
| 10 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Beams, cantilevers, bressummers, lintel over 1.5 span complete all as specified. |
| 11 | Use and removal of steel formwork to sides and soffits of floor or roof beams, beam launchings, girders, bressummers, lintels,cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for rough finished surfaces of concrete complete all as specified and as directed. |
| 12 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as inSlabs supported on walls,beams and columns in floors,roofs, complete all as specified. |
| 13 | Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed. |
| 14 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 15 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6 mm to 8 mm, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 16 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 17 | S & F GI wire cloth / mesh with2 mm dia of wire, average aperture not exceeding 10mm and fixed with tinned tacks or stainless steel wire staples as in lateral reinforcement for concrete, wall, panels/ modules all as per manufacturer\"s instructions, as specified and as directed. |
| 18 | M & L modular bricks in cement mortar 1:6 with Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in etc complete all as spd and directed. |
| 19 | M & L modular bricks in cement mortar 1:4 with Brickwork with flyash bricks, straight or curved on plan to any radius i n half brick thick walls,built in etc complete all as spd and directed. |
| 20 | M & L for Preparing the surfaces of concrete roof and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thickin cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cementincluding mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight notless than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately. |
| 21 | M&L for rendering 15 mm thick in cement mortar (1:6) onbrick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified. |
| 22 | M & L for rendering 5mm thick in cement mortar 1:4 including mixing water proofing compound as per manufacurers instructions over a backing coat of 10mm thick in CM 1:4 on concrete or brick masonry surfacesand finishing the top surface even and smooth without using extra cement complete all as specified and as directed.Note: Water proofing compoundwill be measured and paid separately. |
| 23 | Supply only integral water proofing compoundof approved make |
| 24 | M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling finished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | M&L Preparing of new surface of wall and applying twocoatsof Cement base paint over a coat of alkali resistent primer.Complete all as specified and directed |
| 26 | M & L for preparing newly plastered ceiling surfaces and applying threecoats of white washing complete all as specified and as directed. |
| 27 | M & Lpreparation of newly plastered surfaces of wall and applying two coats ofOBD over a coat of primer including preparation ofsurfaces on walls as specified and directed. |
| 28 | M&L formachine cut kota stone slab flooring 20-25 mm thick over screed bed or bedding layer 20 mm thickin CM1:6, and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing & polishing complete. |
| 29 | M&LKota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade including backing coat 10mm thick in CM 1:4 . |
| 30 | M&L for Non - skid (joint free) coloured Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors/skirting including screed bed or bedding lasyer of mortar 15 mm thick in cement mortar 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 31 | M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 350 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 32 | S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed. |
| 33 | S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed. |
| 34 | S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed. |
| 35 | S & FStop Valves/angle valves, 15 mm dia, cast copper alloy with capstan head, fancy type Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and as directed. |
| 36 | S & F fancy type Bib Taps, Long Body, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Typewith crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-107KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 37 | S & FVitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of lowor high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMTcheck nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and \"P\" or \"S\" trap complete all as specified and as directed. |
| 38 | S & FVitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe and fixed, 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed. |
| 39 | S & F PTMT Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges, fixed with and including Chromium plated brass screws and wooden/plastic cleats [Minimum weight 190 Grams] complete all as specified and as directed. |
| 40 | S & F PTMT Soap Dish with screws complete all as specified and as directed. |
| 41 | S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. |
| 42 | S & F Ball Valves, 25 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 25mm - 455 Grams] etc complete all as specified and as directed. |
| 43 | S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed. |
| 44 | M & L for 40mm bore dia High Density Polyethylene Pipes [HDPE] of pressure rating 6 KGf / Sq.cm laid in trenches or fixed to walls or ceilings or in floors etc. complete all as specified |
| 45 | S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 46 | S & F 75mm outlet PVC [SWR] Floor trap with grating including jointing with solvent cement complete all as specified and as directed. |
| 47 | S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and as directed. |
| 48 | S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed. |
| 49 | S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed. |
| 50 | S & F 110 mm bore PVC [SWR] Branch Piece, Single [Single\"Y\"] equal or unequal jointing with solvent cement complete all as specified and as directed. |
| 51 | S & F 75 mm bore PVC [SWR] Branch Piece, Single [Single\"Y\"] equal or unequal jointing with solvent cement complete all as specified and as directed. |
| 52 | S & F 110mm bore PVC [SWR] Gully Trap with grating including jointing with solvent cement complete all as specified and as directed. |
| 53 | M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding15 cm thick watered and rolled/rammed to a true surface complete all as specified. |
| 54 | M & L for 75 mm thick, PCC 1:3:6, Type C-1, using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth complete all as specified and as directed. |
| 55 | M & L for 100 mm thick, PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in sub floor, floor ect, surfaces finished even and smooth complete all as specified and as directed. |
| 56 | M & L for 25 mm thick, PCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in floor, surfaces finished even and smooth complete all as specified and as directed. |
| 57 | S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC \"C\" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed. |
| 58 | S & F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed. |
| 59 | S & F 100 mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed. |
| 60 | S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 125 mm long complete all as specified and as directed. |
| 61 | S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed. |
| 62 | Supply only 4.00 mm thick Sheet Glass ordinary quality in squares exceeding 0.5 Sq.m in each pane complete all as specified and as directed. |
| 63 | S & FStainless steel curtain rod, 20 mm dia with fixing brackets, end caps etc complete all as specified and as directed. |
| 64 | Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 125 mm x 60 mmfor doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc and applyinga shop coat of red oxide primer including providing PCC 1:3 :6 type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified and as directed by the Engineer-in-Charge |
| 65 | S & F Factory made, 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 66 | S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 \"D\" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed.Make : NCL type-4000 Series (Note : Glass and wiremesh shall be measured and paid separately under respective items) |
| 67 | S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 68 | S & F Aluminium anodised barrel Tower Bolt of size 300 mm size of extruded section complete all as specified and as directed. |
| 69 | S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed. |
| 70 | S & F Floor Door Stopper of size 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed. |
| 71 | M & L for preparation of new undecorated painted wooden surface of any description not otherwise described, over 10 cm width or girth and applying twocoats of Synthetic Enamel paint over one coat of pink primer complete all as specified and as directed. |
| 72 | M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 73 | M & L for providing pre construction anti termite treatment for the backfill in contact with foundation by applying emulsion at the rate of 7.5 litres per square metre of vertical surface [Area of the substructure in contact with back fill] complete all as specified and as directed. |
| 74 | M & L for providing pre construction anti termite treatment for the top surface of filled earth by applying emulsion at the rate of 5 litres per square metre ofsurface complete all as specified and as directed. |
| 75 | M & L for providing pre construction anti termite treatment for the soil under plinth protection by applying emulsion at the rate of 5 litres per square metre of surfacearea complete all as specified and as directed. |
| 76 | M & L for providing pre construction anti termite treatment for the soil along with external perimeter of building by applying emulsion at the rate of 2.25 litres per running metre of the perimeter wall complete all as specified and as directed. |
| 77 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on planand n exc 1.5 m in depth and getting out soft/Disintegrtated rock complete all as specified. |
| 78 | S&F Mild steel work (framed) including grills, gratings stringers, treades, landing, blusters, hand rails etc including cleats, brackets, ladders, walk way, railings and similar work etc complete including cutting, welding with proper overlapping & welding with angle iron bottom as conforming to Fe 410 Gde E-250, complete all as specified and directed by Engineer-in-Charge. |
| 79 | S&F 600 x450 mm fancy typeor bevelled edge mirror of selected quality glass, mounted on 6mm thick ACbuilding board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified. |
| 80 | S&F vitreous china Urinal pot white (size-31x37x64 cm) including partition, waist pipe screw with wall fixing complete, Make-Hindware Cat Part No 60010 or equvallent in Parry ware/cera as approve by GE. |
| 81 | S&F in repair health faucet with double lock 1 meter brass plated stainless steel flexible hose and wall hook complete all as specified and directedMake -Jaquar , Cat Part-No - 563 |
| 82 | S & F in repair CP paper holderof Make-AKP-35751P of Jaquar or equvelent in kohler. complete all as specified and directed. |
| 83 | S & F in repair , PVC connections 15mm size with PTMT nuts of length 450mm and fixed all as specified and as directed. |
| 84 | S & F in repair corner glass shelf set of 3 Nos with bracketof Make-CAN-1173 of Jaquar or equvelent. complete all as specified and directed. |
| 85 | S & F Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staple. |
| 86 | S & F 35 mm, 2nd class hard wood factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all as spd and directed. |
| 87 | S & F 300 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified and directed by engineer incharge |
| 88 | M&Lreinforced cement concrete M 25 type Design mix (20mm graded agg ) Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres etc complete all as spd and directed. |
| 89 | M&L for Formwork to,rough finished surfaces of flat concrete, staircases with sloping or stepped soffits including risers and stringers including landings,etc complete all as spd and directed. |
| 90 | M & L Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 105 mm x 60 mmfor doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc and applyinga shop coat of red oxide primer including providing PCC 1:3 :6 type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified and as directed by the Engineer-in-Charge |
| 91 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4)for bedding of tilescomplete all as specified. |
| 92 | M&L 10 mm thick rendering in cement mortar (1:3) on vertical surfaces for backing of tiles/granite etc complete all as specified. |
| 93 | M&L forNon - skid (joint free) coloured Ceramic tiles 7 to 8 mm thickarea of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 94 | S&F for Vitreous China Urinal, Half stall type, white including waste pipe and water splinder, etc complete all as specifed and directed. |
| 95 | M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments over 15mm thick cement screed bed in cement mortar 1:4 complete all as specified and directed. |
| 96 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Chajjas complete all as specified. |
| 97 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock. |
| 98 | S & F 150mm bore Reinforced concrete pipes, class NP 2 with one collar per length of pipe. |
| 99 | M & L Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregates, as in concrete bed to RCC drain pipes in any depth including packing under and haunching against the sides of pipes 150mm bore after the pipes are laid, jointed and tested all as specified.Note : Drain pipes shall be measured and paid separately. |
| 100 | M & L forSFRC Cover and frame (heavy duty HD-20 grade designation) of suitable size conforming to IS 12592 , total weight of cover frame to be not less than 182 kg, including cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded aggregate20 mm nominal size ) centring , shuttering for fixing of cover , complete all as specified and as directed. |
| 101 | M & L Cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregates as in benching for manholes, bands, coping, bed plate and for embedding rungs etc. with slightly chamfered or rounded angles including necessary form work, if any, and finishing exposed surface even and smooth without using extra cement complete all as specified. |
| 102 | M & L Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete etc. complete all as specified. |
| 103 | M & L Brick work with sub class ‘B’ bricks, old size straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar 1:4 including corbelling and arches where shown on drawings including raking out joints of internal surfaces and pointed flush on external surfaces as the work proceeds complete all as specified. |
| 104 | 15mm thick cement plaster in cement mortar 1:4 to brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.( including water proofing compound as per manufacturers instruction ) |
| 105 | Supply only water proofing compound |
| 106 | M&L cement 1:2:4, type B2, using 40mm aggregate in surface channel and drains, benching and similar work etc. as specified and directed. |
| 107 | Extra for forming fair finished drain or channel 30cm internal girth in cement concrete using extra cement including forms, moulds/mitred, stopped ends etc. |
| 108 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed. |
| 109 | Removal of excavated surplus soil to a distance exc. 500 m but n exc 1.5 km and deposited where directed complete all as specified and as directed. |
| 110 | S & F on site LLDPE septic tank of capacity for 10 User\"s designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for all necessary functioning. Complete all as specified and directed. |
| 111 | M&L Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/ DWC complete filled with brick bats of size 1.80 mtr dia and 3.00 mtr in effective depth complete all as specified. |
| 112 | Demolition of cement concrete in ground floor andpavings n.exc. 15cm thick (Below or above ground level) and removing the same complete, all as specified & directed by Engineer-in-charge. |
| 113 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/disintegrated rock etc Complete all as specified and directed. |
| 114 | M&L for 75 mm thick cement concrete type D-2 1:4:8with )using 40 mm graded stone aggregates) asin sub base of flooring etc Complete all as specified and directed. |
| 115 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved, design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand etc Complete all as specified and directed |
| 116 | M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping ,kneeles, bed plates,apex stones,benching, gola, slightly rounded and similar items complete all as specified and as directed. |
| 117 | Removal of excavated surplus soil to a distance exc. 500 M but n exc 1.5 km and deposited where directed complete all as specified and as directed. |
| 118 | M & L for 100 mm thick, Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) etc as in floorings/pavings of path, finished even & smooth , without using extra cement,complete all as specified. |
| 119 | E&M Items |
| 120 | M & L forconcealed point wiring complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia,with MS stove enamelled modular typesunkenboxes including earth dollywith cover plate with frameof modular typeof approved make and colour including 1.5 sqmm multistranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified anddirected for the followings :- |
| 121 | One light / fan point controlled by one way switch |
| 122 | One 5 Amp socket outleton independent board. |
| 123 | One5 Amp socket outlet on same board. |
| 124 | One bell/buzzer point controlled by one bell push |
| 125 | One light point controlled by two 2-way switch |
| 126 | All as per above item No-119 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed,FRLS cable for 15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified andas directed. |
| 127 | S&F in replacement socket outlet 6A-2/3 Pin combined 2 module 240 volts AC 50 hz ISI markedmodular type complete all as specified and directed. |
| 128 | S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module 240 volts AC 50 hz ISI markedmodular type complete all as specified and directed. |
| 129 | S&F in replacement switch 6 amps modular type one one way 240 volts AC 50 hz ISI marked complete all as directed. |
| 130 | S&F in replacement switch 16 amps modular type one one way 240 volts AC 50 hz marked complete all as directed. |
| 131 | S&F in replacement modular type bell push 6 amp one module 240 volt ISI marked complete all as specified and directed. |
| 132 | S&F in replacementBell, DING DONG AC 230 Volts single pole type complete all as specified and asdirected. |
| 133 | S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals completeall as specified and asdirected. |
| 134 | S & F of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of4.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note:(i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 135 | S & F ofsub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directedwith and including one run of6.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note:(i) Two runs of 6.0 sqmm cable and one run of 6.0sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 136 | S&Fof sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 8 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make ofMCBs and DB should be same |
| 137 | S&F in replacement of single pole and neutral enclosure with 2 pin and metal earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and as directed.Make-Havells/Indoasian/Legrand |
| 138 | S&F in replacement of Double door three phasedistribution board4 way IP 54 IK 09loadline VTPN with 125 Amp MCCB to be used as incomer and made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar250 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection complete all as specified and directed (Note:-(a) Rate of MCCB and MCBs are included in quoted rate. (b) capacity of Single pole MCB shall be provided as per requirement and direction. (c) Make of MCB /MCCB and DB should be same. |
| 139 | S&F in replacement MCB SP 6 to 32 Amps,240 volts curve \"B\",breaking capacity 10KA,all as specified. |
| 140 | S&F in replacement MCB SPN16 to 40 Amps,240 volts,curve \"C; breaking capacity 10 KA, all as specified. |
| 141 | S & F In replacement ofmodular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and asdirected. |
| 142 | S & F in replacement ofmodular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified as as directed. |
| 143 | S&F inmodular blanking plate, 1 module ISI Marked complete all as specified and as directed. |
| 144 | Supply and fixing in repair ofEarthing to DBs with galvanised steel earth plate electrode60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board includingexcavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.Note- cost of 7.5 RM of GI wire shall be included in quoted rate |
| 145 | S&F in replacementenviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting PC housing ,high efficient LEDs with opal diffuser and IP65 protectio, lumen efficacy 85 lm/watt with colour temerature 3500K/6500K as per site requirement, THD≤20 CRI>80,2.5 kV surge protection all as specified and directed. |
| 146 | S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. |
| 147 | S&F in replacement of enviroment friendly indoor decorative 9/10 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. |
| 148 | Supply & fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as specified and as directed by Engr-in-Charge. |
| 149 | Supply & fixingexhaust fan, steel body AC single Phase. 230V of size 300 mm sweep double bearing with, 1400 RPM, blades, and frame and louver complete all as specified and as directed by Engr-in-Charge. |
| 150 | Supply and fix electric water heater, storage type with SS tank and outer body made out of ABS & PP, heating element of 2 KW storage capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, SS connection piece of suitable length etc complete all as specified and as directed by Engr-in-Charge. |
| 151 | S&F LED bldg light fitting 35/36 Watt, having uniformty ratio 0.25 , high pressure die cast aluminium housing , heat resistant toughened glass frame , IP-65 protection complete with lamp & connected items and connection with suitable cable from celing rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2 m long bend to shape and fixed on wall with flat iron clamps nut, bolts washers etc specified and directed |
| 152 | Supply and fixingLED type flood light 120 watt 230 watt volts AC outdoor type with t IP 65 classprotection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range140v to 270 V, totallumen efficiency =80 lm/watt , THD≤20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. |
| 153 | Supply, laying, jointing and testing XLPELTCable insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed systemof size 4.0 core x 25Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed. |
| 154 | Supply, laying, jointing and testing XLPELTCable insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and of size 2.0 core x 10 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed. |
| 155 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 25 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 156 | Excavation in trenches in soft/loose soilnot exceeding 1.5 meter wide & not exc 1.5 mtrdeep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge. |
| 157 | Returning, filling in including spreading levelling watering and well ramming in layersnot exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge.. |
| 158 | Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 159 | M & Lfor dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed . |
| 160 | Material labour for common burnt clay bricks, sub class \"B\" grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge |
| 161 | Supply and fixingof GI tubing, light grade, 80 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete. |
| 162 | Supply and fixingof GI tubing, light grade, 50 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete. |
| 163 | M&L for cutting GI pipes 80 mm Diafor insertion of new tees,branches connecton for new branch including any tee and necessary accessories complete all as specified and directed. |
| 164 | M/Lvalve pit chamber of size 450 X 450 X 450 mm internal dimension , 6mm thick MS steel cover with 2 Nos MS hinger suitable size welded with angle iron frame of 40x40x6mm thick with lifting hooks and locking arrangement complete with necessary earth work, brick work in cm (1:6), 230 mm thick PCC bed (1:4:8) type D-2, 150mm thick, 15mm thick cement plaster in cm 1:4 internal surface complete and external surface of wall up to 300 mm front top and applying a coat of black bituminous paint to the steel surface complete. |
| 165 | M&L for tubing medium grade galvanized with all fitting laid in trenches complete of size 20 mm bore complete all as specified and directed. |
| 166 | M&L for tubing medium grade galvanized with all fitting laid in trenches complete of size 15 mm bore complete all as specified and directed. |
| 167 | M&L for Gun-metal gate valve of size 20 mm with iron wheel head, screwed both ends for iron pipe and fixed. |
| 168 | All as per Item No 5 Above but15 mm Bore |
| 169 | Excavation in trenches in soft/loose soilnot exceeding 1.5 meter wide & not exc 1.5 mtrdeep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge. |
| 170 | Returning, filling in including spreading levelling watering and well ramming in layersnot exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge.. |
| 171 | Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail