| 1 | Taking down chowkhats or frame n.exc 1.50 Sqm each with shutter without taking off shutter from framed complete incl removing from site complete all as directed |
| 2 | S&F powder coated Aluminium anodised hanging type glazed window manufactured with approved aluminium section with two hang shutters each shutter width same of the length of window with the following specifiecation and making good the adjascent surfaces :-(a)Two Nos Window frame of each window of cross section 50.5mmx40mmx1.5mm thick over all size 101mmx40mmx1.5mm thick, .(b) hanging type smooth shutters of cross sections 91.80mmx31.75mmx1.1mm thick. (c) hanging shutter frame of cross section 40x18x1mm.(d) Aluminium glazing stip of size 18.2x16.66mm. (e)4mm thick flat glass superior quality for one shutter. (f) IDPE rubber gasket for fixing glass. (g) Aluminium aldropbolt 150mm, 2 No each shutter. (h) 02 Nos Aluminium handle 150mm per shutters. (j)aluminium wire cloth 0.36mm stainless steel nominal dia of wire and average width of aperature 1.40mm for one shutter (k) 2 Nos Each shutter 100mm mild steel butt hinges .(k) Fixing screws for frame with wall 06 per window with fancy design.(Note: Window will be measured outer to outer frame and no extra to be paid. The grill will be fixed between the two window frame. window iron grill will be measured and paid separately in respective item. |
| 3 | Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etccomplete all as directed. |
| 4 | M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement. complete all as directed. |
| 5 | M&L for applyingtwo to three mm thick coat ofwall care putty and making the surface even and smooth on entire satisfaction of Engineer-in-Charge& preparation of surfaces for further treatment and after prepration of surfaces, applying two coats of oil bound distemper over & including a coat of primer on newsufaces complete all as specified and directed. |
| 6 | M & L for PCC (1:2:4), type (B-1) using 20 mm graded stone aggregate as in filling of hold fast and similar work all as specified and directed. |
| 7 | M&L for M.S Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. complete all as specified and directed. |
| 8 | M & L for preparation of New or previously un-treated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 9 | Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etccomplete all as directed. |
| 10 | M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement.complete all as specified & directed. |
| 11 | M&L for rendering 15 mm thick on other than fair faces of bricks/concrete surface in cement mortar (1:4) mixed withusingWPC as per manufacturer\"s instructions finishing the surfaces even and smooth without using extra cement complete all as specified & directed.(WPC shall be measured & paid seperetly) |
| 12 | M&L for 10 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as specified and directed. |
| 13 | M&L for preparing newly platered surfaces and applying two coat of distemper oil emulsion white or tinted over priming plastered or other surface with alkalli-resistant priming paint over and including 1mm thick wall care putty on ceiling complete all as specified and directed |
| 14 | Complete removal of existing treatment of ceiling surfacesand applying two coats of distemper oil emulsion white or tinted over priming plastered or other surface with alkalli-resistant priming paint overand including 1mm thick wall care putty on ceiling complete all as specified and directed |
| 15 | M&L for preparing newly platered surfaces and applying two coat of distemper oil emulsion white or tinted over priming plastered or other surface with alkalli-resistant priming paint overand including1mm thick wall care putty on walls complete all as specified and directed |
| 16 | Complete removal of existing treatment and applying two coats of distemper oil emulsion white or tinted over priming plastered or other surface with alkalli-resistant priming paint over and including 1mm thick wall care putty on walls complete o all as specified and directed |
| 17 | M&L for preparingthe new plastered surfacesand applying twocoats of exterior Emulsionweather proofpaint white or tinted on walls/soffit of chajjasurfaces complete all as specified directed. |
| 18 | Complete removal of existing treatment and applying two coats of exterior Emulsionweather proof paint white or tinted on walls/soffit of chajjasurfaces complete all as specified directed. |
| 19 | Supply only integral water proofing compound,ISI marked |
| 20 | Taking down chowkhats or frame exc 1.50 Sqm but n.exc 4.00 Sqm each with shutter without taking off shutter from frame complete andremoving from site. complete all as directed. |
| 21 | Resecuring or easing and adjusting without taking down shutter of any description exc 1 sqm and n exc 2 sqm each complete all as directed. |
| 22 | M&L for Pressed steel frames for doors (105X60MM) with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.including filling of PCC 1:3:6 type C0complete all as specified and directed. |
| 23 | M&L for 35mm thick 2nd class HW rail and style plain framed, factory made paneled shutter (one panel) without interlocking rail and 12mm veneered particle board with commercial veneering on both faces the size of rail and style as per IS -1003 (Pt-I)kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 24 | S & F powder coated anodised alm ventilator louvre type with two separate frame of size 50.5mmx40mmx1.5mm thick (01x frame for fixing of 5mm thick coloured glass & 01x frame for fixing SS wire mesh) powder coated anodised aluminiumsection weighing 0.55 kg/m including 5mm thick coloured glass, SS wire mesh and necessary joining cleats, glazing clips, rubber packing, side handles fixed to wall with fastener etc, complete all as specified & directed. |
| 25 | S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube S&F in opening all as shown on drawing and specified. |
| 26 | S&F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap inside for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rail with suitable PVC sheet bending and jointed to gather with solvent cement supplying and fixing in the frame at site as per specification and drawing. complete all as specified & directed. |
| 27 | S&F in repairs for galvanised steel wirecloth 0.56 mm nominal dia of wire and average width of aperture 1.00 mm complete all as specified & directed. |
| 28 | S&F butt hinges 100mm long medium weight cold rolled MS and fixed complete all as specified & directed. |
| 29 | S&F 150 mm long aluminum anodized barrel tower bolt extruded section complete all as specified & directed. |
| 30 | S&F aluminum handles cast type anodize 150 mm long complete all as specified & directed. . |
| 31 | S&F aluminium alloy anodized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alumionium alloy and fixed 300mm long complete all as specified & directed. |
| 32 | M & L for preparation of New or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 33 | M&L for preparation of old painted steel surfaces of any description over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 34 | M&L for preparation of old painted surfaces of wood and wood based materials of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 35 | Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level including removal of same to exceeding 1 Km but not exceeding 1.5 Km complete all as directed. |
| 36 | Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc. |
| 37 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed. . |
| 38 | M&L for glazed ceramic tiles coloured of size 350x250x7mm/450x350x7mm thick fixed in verticle surfaces, set and jointed in neat cement slurry and pointed in white and colour cement to match incl 10mm thick screed bed in CM 1:4 as specified & directed.. |
| 39 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular)area of each tiles exceeding 0.06 sqm but n.exc 0.11sqm infloor etc,over 15 mm thick screed bed in CM(1:4),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed. |
| 40 | M&L for coloured non skid cermic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed in CM 1:6 all as directed. |
| 41 | All as item No 40 here in before but on vertical surface as skirting over and incl 10 mm thick rendering in CM 1:3 |
| 42 | M & L for 25mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in flooring finished even and fair.complete all as specified & directed. |
| 43 | Demolition of reinforced cement concrete(reinforcement cut as required to facilitate demolition) of slab, of any description and in any position not other wise specically provided for removalof same to exceeding 1 Km but not exceeding 1.5 Km complete all as specified and directed. |
| 44 | Demolition of brick work built in cement mortar or lime mortar complete of any description all as directed. |
| 45 | M & L for brick work with fly ash modular bricks straight or curved on plan exc 6m mean radius built in CM 1:6 including Demolition of brick/stone work built in cement mortar including all quoins, arches, pillar including coping etccomplete all as specified anddirected.. |
| 46 | M&L for 100 mm thick PCC 1:4:8 Type D-2 using 40mm graded stone aggregate as in sub base all as specified and directed. |
| 47 | M&L for 75 mm thick PCC 1:3:6Type C-2 using 40mm graded stone aggregate as in plinth protection etc, laid to slope of 1:12 and shall be laid in alternate bays n.exc 1.5 m in length, joints 20mm wide will be provided every 1.5m and filled with sealing compound grade ‘A’ the joints between external wall and plinth protection shall also be laid with ceiling compound grade ’A’, finishedcement concrete surface even and smooth all as specified and directed. |
| 48 | M&L forrepair and rendering 10mm thickin on 1:3on chajjas not exceeding 60cm width after removing cracked plaster and concrete includingcleaning of viisible reinforcementandtreating with cement slurry also necessary repair to cracked concreteif any with cement concrete1:2:4 Type B-0 using 12.5mm gradedstone aggregateincluding necessary scafolding work for double/single storey bldgsall as specified and directed. |
| 49 | M/L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in sunken floor .average thickness 50mm and making adequate slop towards spout pipe etc complete all as specified and directed. |
| 50 | M&L for rendering 10mm thick on fair faces of brick or concrete surfaces and finishing the surfaces fair and even without using extra cement in CM (1:4) mixed with WPC as per manufacturer\"s instructions complete all as specified and directed. (WPC will be measured and paid separately) . |
| 51 | M&L for PCC (1:5:10) type E2 using 40mm graded brick aggregate as in sunken portion complete all as specified and directed. |
| 52 | S&F 32 mm dia GI spout light grade for sunken portion complete complete all as specified and directed. |
| 53 | M&L for bitumen blown 85/25 applied hot two coats to concrete surfaces at rate of 1.2 Kg/sqm per coat complete all as specified & directed.. |
| 54 | M&L for polythene film black 200 micron laid in floors etc complete all as specified & directed. |
| 55 | M&L for roof treatment over in-accissible roofs in repair by complete removel of existing oldtreatment , properly cleaning and drying concrete surfaces and treatedwith following specifications:(a) Brushing neat cement slurry @ 3Kg per Sqm on roof slab.(b) 15 mm thick cement plaster fair finished using cement mortar (1:4) mixed with WPC (as per manufacturer instruction) on roof slab.(c) Applying oil based bitumen primer @ 0.30 ltr/Sqm on plastered surface.(d) Applying modified APP polymeric membrane 3mm thick and minimum weight 3.00 Kg / Sqm for water proofing of roof , sealing as directed at site with 100 mm over laps as per manufacture\"s instruction.(e)Applying two coat of aluminium paint over bituminous surface of membrane.complete all as specified and directed |
| 56 | Demolition of side wall and top of old RCC water tanks 1000/500 ltrs capacity excluding tank beam and tanks bottom slab after removing existing inlet and outlet connection with all fitting and reparing remaining structure with plastering and making the surface flat and level in CM 1:4complete all as specified and directed. |
| 57 | Dismantling of existing water tanks and removinging to store and S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top double layered) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed.complete all as specified & directed. |
| 58 | S&F in repair for PVCconnection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as specified and directed. |
| 59 | Cutting chases in brickwall pinning in making good to facings where required and pointing in cement mortar 1:3 to ends and cutting chases for concealed water tubing and making good cutting n.exc. 10 cm girth.complete all as specified & directed. |
| 60 | Taking up or down steel tubing and connection of 15 mm bore complete all as directed at site |
| 61 | All as per item No 60 here-in-before but for 20 mmbore pipe |
| 62 | S & F 15 mm bore galvanised steel water tubing medium gradewith and including all fittings and fixed to walls and ceilings or laid under floorscomplete all as specified and directed. |
| 63 | All as per item No 62 here-in-before but for 20 mm bore |
| 64 | S&FAngle 15 mm bore, fancy type chromium plated, or butterfly handle, screwed both ends for iron pipe or for unions and fixed. complete all as specified & directed. |
| 65 | S&F in repair, 15mm borebib taps fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed |
| 66 | S&F in repair, 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipecomplete all as specified and directed. |
| 67 | S&F in repairs Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed |
| 68 | S&F in repairs for shower rose chromium plated with or without swivel joints 125 mm dia complete all as specified and directed |
| 69 | S&F in repairs for pillar tap of 15mm bore pipe, fancy type cast copper alloy with capstain head chromium plated with or without lettered “hot or cold” with long screwed shanks and fly nuts screwed for iron pipe fixed complete all as specified and directed. |
| 70 | S&F in repair vitreous china wash basin, white flat back size 550 x 400 mmincluding waste, chain & plug and poreclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated for WHB etc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waste pipe fitted complete all as specified and directed |
| 71 | S&F in repair Vitreous China urinals, bowl type flat back, size of 465 x 355 x 265 mm (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) including 32mm dia waste pipe fitted complete all as specified and directed |
| 72 | M &L 600x450mm beveled edge mirror of selected quality glass mounted on 6mm thick AC building boardor commercial ply wood and fixed to wooden ply with chromium plated brass screws and cup washers. complete all as specified & directed. |
| 73 | S&F brass chromium plated tubular towel rail 20 mm dia \"D\" type 60 cm long between flanges complete all as specified and directed |
| 74 | S&F in repair for 10ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene complete all as specified and directed. |
| 75 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittins,heads,shoes,bends,swan-necks,etc including removing from site. complete all as specified & directed. |
| 76 | M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 77 | M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 78 | S&F PVC (SWR) bends 110 mm bore of any radius all as specified & directed |
| 79 | S&F PVC (SWR) bends 75 mm bore of any radius all as specified & directed.. |
| 80 | S&F PVC (SWR) junction single (singleT) equal or unequal110mm bore provided with access door all as specified & directed.. |
| 81 | S&F PVC (SWR) junction single (singleT) equal or unequal 75mm bore provided with access door all as specified & directed.. |
| 82 | S&F 110 mm bore PVC (SWR) vent cowl.complete all as specified & directed. |
| 83 | S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement.complete all as specified & directed. |
| 84 | S&F 110mm dia PVC (SWR) WC connector with lip ring |
| 85 | S & F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays of 100mm bore of pipe Including bolts and nuts and securing ends of stays to wall or roof. complete all as specified & directed. |
| 86 | S & F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays of 75mm bore of pipe Including bolts and nuts and securing ends of stays to wall or roof, complete all as specified & directed. |
| 87 | S&F vitreous china squatting pan ORRISA Pattern of size 580x 440mm white with integral foot rest complete (excluding cistern and flush pipe) with provn of lime concrete including backing joints complete all as specified & directed. |
| 88 | S&F in repairs CP soap dish approximate size 160x160x90mm complete all as specified & directed. |
| 89 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as directed. |
| 90 | Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good thedisturbed surfaces of walls,floors roofs etc complete all as directed. |
| 91 | Taking down old/unserviceable MCB DB SPN any capacity by disconnection of electric connectionincludingMCBs,Isolators,etc and making good to disturbed surface complete all as directed. |
| 92 | Taking down Old/ Unserviceable MCBDBs TPN / Main Switchesby disconnection of electric connection including old unsvMCCBs,MCBs, isolators etc and making good to distrubed surface complete all as directed. |
| 93 | M&L for point wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed.Note: Therate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing ofswitch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces. |
| 94 | All as per Ser item No 93 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 95 | All as per Ser item No 93 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 96 | All as per Ser item No.93 here - in - before but one lightpoint controlled by two 2 - way switches,with wire 1.5 Sqmm size |
| 97 | All as per Ser item No 93 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 98 | S&F Switch modular 2 way 6 Amps 230 vcomplete all as specified and directed at Site. |
| 99 | S&F Switch modular 1 way 6 Amps single pole complete all as specified & directed. |
| 100 | S&F Switch modular singlepole , one way 16 Amps complete all as specified and directed. |
| 101 | S&F Socket modular 2/3 pin combined 6 Amps complete all as specified and directed. |
| 102 | S&F Socket modular 2/3 pin combined 6/16 Amps complete all as specified & directed. |
| 103 | S&FCeiling rose,3 terminal PVC/polycarbonatecomplete all as specified and directed. |
| 104 | S&F modular fan regulator step type,230 Volts single phase 120 wattcomplete all as specified and directed at site. |
| 105 | M&L for submain complete with 2x 4 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm diaas per site requirement along walls/ceilingetc including 4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces.(iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length) |
| 106 | Supply and fixMCBDB SPN 12 way double door with metal door suitable forhousing of MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. |
| 107 | Supply and fix MCBDB TPN 4 way with metal door suitable forProvision ofincommer and out going MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 108 | Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed at site. |
| 109 | S&F in replacement ofMCB SP 6 to 32 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 110 | S&F in replacement of MCB DP 40Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles. |
| 111 | S&F in replacement ofisolator DP 63 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 112 | S&F in replacement of LEDtube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting withaluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed at site. |
| 113 | S&F in replacement of Lienear & compact9 wat LED mirror light with decorative grey end caps,polycarbonate body and ribbed opal diffuser including 2/3 core flexible copperwire with flexible pipe ceiling rose to light fittings complete all as specified and directed at site. |
| 114 | M&L for repair and greshing of ceiling fan of any size sweep single phase. Ceiling fan of any size opening from any height or any locations, fan opening from hook, clamp & refixing the same after cleaning and greshing with required necessary cutting/welding/granding job or required store such as nuts, bolts, washer and suitable length mild steel/ down rod duly making holes etc complete as specified and directed. |
| 115 | S&F in replacementExhaust fan , steel body complete with louvers shutter AC single phase 230 bolts of size380 mm sweep and including makingof holes/in existing hole of suitablesizefan base after cutting of brick/stone wall suitable sizecomplete all as specified and directed. |
| 116 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of depth not less than 0.90x 0.60 x 2.25 mtr below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earthstripof size 25x3 mm, 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth lead protection pipe light gade GI of size 32/40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I connected to earthing lead with Main switch/main control board,filling with charcoal dust 200 Kg, and common salt 100 KG ,including necessary excavation and earth work in any type of soil ,perforated watering pipe,funnel with wire mesh,earth lead protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 8 mm dia TMT bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EICNote :(i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm top of GI Plate. |
| 117 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |