| 1 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 2 | Material and labour for brick work with sub class \"B\" brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 3 | Material and Labour for brick work with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 (using old size bricks)including demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 4 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 5 | Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and smooth (without using extra cement) complete all as specified and directed. |
| 6 | Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, surface finished even and fair (without using extra cement) complete all as specified and directed. |
| 7 | Material and labour for 10mm thick rendering on concrete surface in cement mortar 1:3 surface finished and smooth as in ceiling complete all as specified and directed. |
| 8 | Material and labour for preparation of newly plastered surface of walls including corners and applying two coats ofdistemper oil emulsion over applying one coat of wall care putty not less than 1mm thick, finish wall surface even and smooth all as specified and directed. |
| 9 | Material and labour for two coats of exterior grade 1st quality weather coatpaints over a coat of alkali resistant priming paint over applying of 1-1.5 mm thick wall care putty finish wall surface even and smooth including preparation of new plaster external surfaces of wall etc complete all as specified and directed. |
| 10 | Material and labour for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 11 | Material and labour for complete removal of existing decorated surface and preparation of walls and applying two coat of oil bound distemper over andincluding 1-1.5mm thick wall care putty complete all as specified and directed. |
| 12 | Material and labour for preparation of old decorated surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed. |
| 13 | Material and labour for complete removal of existing treatment of walls including corners and applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm wall surface even and smooth including 1-1.5mm thick wall care putty complete all as specified and directed. |
| 14 | Material and labour for preparation of old decorated surfaces of walls and applying one coat of cement base paint in any tint complete all as specified in SSR Part I and directed. |
| 15 | Material and labour for preparation of old decorated surfaces of ceiling and applying one coat of white wash complete all as specified in SSR Part I and directed. |
| 16 | Material and labour for preparation of old painted surfaces of wood of any description over 10 cm width or girth and applying one coat of synthetic enamel Paint complete all as specified and directed. |
| 17 | Material and labour for applying one coat of synthetic enamel paint on old painted steel surfaces/concrete surfaceof any description including preparation complete all as specified and directed. |
| 18 | Material and labour for Vitrified Ceramic tiles light shade 7-8 mm thick (square/rectangular) polished area of each tiles exceeding 0.42 Sqm but not exceeding 0.72 sqm in floor etc. over and including screed bed 15 mm thick in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile including dismantling of existing tiling complete all as specified and directed. |
| 19 | Material and labour non skid/mat finish coloured joint free ceramic tiles 7 to 8 mm thick, area of each tile exc. 0.11 sqm but not excd. 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, including dismantling of existing tiling complete all as specified and directed. |
| 20 | Material and labour for glazed ceramic colour tiles size 300 mm x 450 mm x6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existingwall tiling including cement mortar bedding (but not backing) andrubbish off the premisescomplete all as specified and directed. |
| 21 | Demolition of Cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 22 | Material and labour 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in leveling course to floors complete all as specified and directed. |
| 23 | Material and labour for 75mm thick cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed. |
| 24 | Material and labour for cement concrete type B1 1:2:4 (20mm graded aggregate) as in window or door cills, lintels, copings. kneelers, apex stones, posts, boundary pillars, bonders (for stone walling), brackets, etc. with plain fair faces, including chamfers, weatherings, throating etc. complete all as specfied and directed. |
| 25 | Supply and fixfor 15 mm bore pipe medium grade galvanised iron with all fittings fix ed to wall and ceiling or laid in floor including taking down of old unserviceable pipes, complete all as specified and directed. |
| 26 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and directed. |
| 27 | Supply and fix medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing including dismantling of old tubing complete all as specified and directed. |
| 28 | Taking down CI/AC/PVC pipes incl fittings upto 110mm dia and removing from site complete all as specified and directed. |
| 29 | Supply and fix PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls or laid in trenches or floors complete all as specified and directed. |
| 30 | Supply and fix PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls or laid in trenches or floors complete all as specified and directed. |
| 31 | Supply and fix PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed. |
| 32 | Supply and fix PVC (SWR) bends of 75 mm dia, any radius complete all as specified and directed. |
| 33 | Supply and fix PVC (SWR) junction single Tee equal or unequal 110 mm dia complete all as specified and directed. |
| 34 | Supply and fix PVC (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed. |
| 35 | Supply and fix rotational moulded polyethylene water storage tanks capacity of tank 500 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site complete all as specified and directed. |
| 36 | Supply and fix rotational moulded polyethylene water storage tanks Capacity of tank 1000 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site complete all as specified and directed. |
| 37 | Supply and fix in repair PTMT Ball valves 20 mm bore, high pressure with epoxy coated Aluminium rods & high density plastic ball screwed and fixed complete all as specified and directed. |
| 38 | Supply and fixing in repair heavy duty thread type PVC water tank cover with fixing frame fixed on PVC tank with 4 Nos of screws for 500/1000 ltrs tank complete all as specified and directed by the Engr-in-Charge. |
| 39 | Material and labour for cleaning of water storage tank capacity not exceeding 1000 litres, mechanically using pressure pump with disinfectant chemical including cleaning & removing all scale & dirt etc from existing tanks, mouths of circulating pipes and outer surface of any description & washing down in the manner and marking the outer surface of overhead tank with synthetic enamel paint using stancils (Date of cleaning month & Year) complete all as specified and directed. |
| 40 | Taking out& removing existing roof treatment of any description completely upto concrete surfaceincluding racking out joints, hacking for key,sweeping clean and scrubbing down with water etc to remove dust etc,complete all as specified.. |
| 41 | Material and labour for brushing neat cement slurry @ 3 Kg of cement per Sqm on cleaned roof/wall surface complete all as specified. |
| 42 | Material and labour for rendering 10 mm thick in cement mortar 1:4 mixed with water proofing compound @ 3% by weight of cement in roof surface, complete all as specified and as directed.(Note- WPC shall be measured and paid separetely.) |
| 43 | Supply only integral water proofing compound as per manufacturers instructions ,complete all as specified. |
| 44 | Material and labour for Water proofing roof treatment withPolymeric water proofing membrane of weight not less than 3Kg/sqm and minimum 3mm thick, five layers with center core as 90 micron high molesuvre, high density polythene film sand witched between two layers of polymeric (Static polythene based) between laminated on both sides with 20 micron HMDPF film over a coat of hot blown bitumen with 85/25 grade @ 1.20 Kg/Sqm after priming the surface with bituminous emulsion@ 0.30 Litre/Sqm on plastered surface. Water proofing membrane should be laid with over laps 150 mm at ends and 75 mm for sides and shall be bounded uniformity by LPG torch flame over the polymeric water proofing membranes apply semi hot blown bitumen 85/25 grade @ 1.20 Kg/ sqm dusted sand over the coat of the coat @0.5 Kg/Sqm, and applying aluminium reflective paint over it complete all as specified and as per manufacturers instructions. NOTES : - (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor\" risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. Contractor\"s quoted rate for this item shall deemed to be inclusive of this aspect. |
| 45 | Dismantling of Asbestos cement (corrugated, semicorrugated or plain, etc.) sheets in roof coverings complete all as specified and directed. |
| 46 | Supply and fix for prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajja and parapet wall covering fixed with self tapping screws complete all as specified and as directed. |
| 47 | Supply and fix for prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick (AZ-150) of an ecofriedly colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed. |
| 48 | Material and labour for providing & fixing false ceiling ofDesigner tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grams, both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and cross \"T\" of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main \"T\" at 600 mm c/c toform a grid of 1200x600mm and secondary cross \"T\" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mmand laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main \"T\", bottom exposed width of 15mm of all \"T\"\" sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width including dismantling of old boarding complete all as specified and directed. |
| 49 | Dismantling of old timber scantlings 40 sq cm and over in section in any position in unframed work complete all as specified and directed. |
| 50 | Supply and fix for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe 410-W(Gde E-250) quality-A including fixing with fasteners not less than 12mm dia complete all as specified and directed. |
| 51 | Demolition of reinforced Cement concrete as in overhead tank of any description and in any position not otherwise specifically provided for complete all as specified and directed. Note: Capacity of tank not execeeding 2000 ltrs |
| 52 | NOTE:- Amount of credit ofRs. 72450.00for retrieved materials is mentioned in Schedule of Credit Page No 18 of tender documents in pdf form which will be deducted offline while acceptance of tender. |