| 1 | Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level complete all as specified and directed. |
| 2 | Dismantling of stone slabs & tiles of any description or thickness (except ceramic tiles) in floors, aprons etc laid bedded & pointed in any mortar complete all as specified and directed |
| 3 | M&L Cement concrete 1:3:6, type C-1 (using 20 mm graded stone aggregate) as in sub base, levelling course, coping, etc complete all as specified and directed |
| 4 | M & L 50 mm thick PCCtype B - 1 1:2:4 using 20 mm graded stone aggregate as inflooring, path, Hardstanding, etcfinish even & smooth with using extra cement complete all as specified and directed |
| 5 | M & L 40 mm thick PCCtype B - 1, 1:2:4 using 20 mm graded stone aggregate as inflooring,etcfinish even & smooth with using extra cement complete all as specified and directed. |
| 6 | Forming construction joint 30mm deep x 10mm wide filled with Grade \"B\" sealing compound complete all as specified and directed. |
| 7 | Supply only 38mm wide glass dividing strips, 3mm thick complete all as specified and directed. |
| 8 | M&L Cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base etc. complete all as specified and directed. |
| 9 | M&L Cement concrete 1:2:4, type B-0 (using 12.50 mm graded stone aggregate) as in levelling course, flooring / hardstanding, coping, window cilletc. complete all as specified and directed. |
| 10 | M/L for Screed bed or bedding layer of cement mortar 15 mm thick for laying floors finishes in cement mortar 1:4 complete all as specified and directed. |
| 11 | M/L for pre polished Chequered cement concrete tiles 20cmX20cmX25mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed. |
| 12 | M&L for Hardcore of broken stone boulder ofgauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and as directed. |
| 13 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed |
| 14 | M&L for Machine pressed precast conctete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 15 | All as per Sl. item No. 14.00 above but except paver blocks. |
| 16 | M & L for 75 mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mmwideand 65mm deep joints shall be made at 3 mtr intervel andat each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3. |
| 17 | Chipping off existing loose, damaged concrete from RCC members of all affected RCC Columns, beams,slabs and chajjas on external and internal facades etc beyond main reinforcement carefully with chisel and hammer including relieving structural members such as column, beam and slabs of their superimposed load partially or fully by provision of adjustable steel props, frames,etc. Providing and applying \"Rusticide SS\" Rust passaviator or equivalent as specified in the brand names to existing reinforcement bars including wire brushing of reinforcement,cleaning,washing of concrete,etc complete as directed. Providing and applying two coats of rust preventor slurry made out of \"polyalk Fixoprime\" or equivalent as specified in the brand names and cement in prorortion 1:1.5 to existing reinforcement bars as directed complete. Providing and applying bonding coat of slurry made out of \"Polyalk EP\" or equivalent as specified in the brand names and cement in proportion 1:1 to concrete and reinforcement substrates complete as directed. Providing and applying \"Polyalk EP\" or equivalent as specified in the brand names. Providing modified cement mortar in required proportion ((1:5:15) to RCC members including hand packing, curing and making the surface rough for plastering. |
| 18 | M&L TMT bars 10 mm dia and over cut to length bend to shape required, including cranking, bending spirally for hoping for columns hooking ends and binding with MS steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed. |
| 19 | Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc. complete all as specified and directed. |
| 20 | Demolition of brick work built in cement mortar. |
| 21 | M&L brick work with sub class \"B\" brick straight or curved on plan exc 6m means radius build in cement mortar 1:4 complete all as specified and directed. |
| 22 | M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and fair without using extra cement complete all as specified and directed. |
| 23 | M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) on wall finishing the surfaces even and fair without using extra cement complete all as specified and directed. |
| 24 | M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) withusingWPC (WPC shall be measured seperetly)on wall finishing the surfaces even and fair without using extra cement complete all as specified and directed. |
| 25 | M&L for 10 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as specified and directed. |
| 26 | Supply only water proofing compound (liquid), ISI marked. |
| 27 | M&L for preparation of newly plastered surface and applying 02 two coat of oil bound distemper over a coat of alkali resistant primer including two coat of wall care putty complete all as specified and as directed. |
| 28 | M&L for preparation of newly plastered surface of ceiling and applying 02 two coat of oil bound distemperover a coat of alkali resistant primer complete all as specified and as directed. |
| 29 | M&L for preparation of newly plastered surface and applying two coat ofAcrylic Smooth exterior paint of required shade (Camouflage) applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as per manufacturer instruction. |
| 30 | Demolition of cement concrete reinforced as in chullah hoods , shelves and plate form etc. complete all as specified and directed |
| 31 | M&L for RCC as in kitchen platform, shelves, etc type BO 1:2:4 (12.5 mm graded aggregate) including necessary form work complete all as specified and directed. |
| 32 | S&F mild steel deformed bars 8 to 10mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns, hooking and binding with and including mils steel wire (annealed) not less than 0.9 mm dia quality conforming to Fe-410-S or F-410-0 etc. complete all as specified and directed. |
| 33 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 34 | S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen with plugs, washers, waste coupling, waste pipe incl bedding in cement mortar to dwarf wall or incl fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as directed and specifed . |
| 35 | S&F in repair block boards 18/19mm thick gde 2 quality, interior grade, commercial type for cupboard shutter, shelf, etc. complete all as specified and directed. |
| 36 | S&F in repair 18/19mm thickpre-laminated particle board interior grade, prelaminated one side with decorative choice lamination & other side balancing white laminationfor cupboard shutter, shelf, etc. complete all as specified and directed. |
| 37 | S & F 75 mm size Butt hinges medium weight cold rolled mild steel and fixed. |
| 38 | S&F 100mm long hasp & staple aluminium anodised wire type,incl bolt to hinge plate and fixed with screw complete all as specified and directed. |
| 39 | S & F Aluminium anodised handles of extruded section and fixed 125 mm long. |
| 40 | M/L preparation of new wooden surface any description over 10 cm width or girth and applying two coat synthetic enamel paint over a coat pink primer all as spfd . |
| 41 | M & L preparation of old decorated surfaces and applying one coat of oil bound distemper on walls, white or tinted complete all as specified and directed. |
| 42 | M&L for preparation of old wall surfaces and applying onecoat ofAcrylic Smooth exterior paint of required shade complete all as specified and directed. |
| 43 | Taking down aluminium doors shutters only (area exc 1.0 sqm but not exc 2.0 sqm each)and dismantling all members and reassembling the same with and including new screws, new rubber gasket,new aluminium beads & cleats of existing make and also refixing the handles & mortice locks in existing position with and including new screws including refixing the door shutters in same opening complete all as specified & directed. |
| 44 | Taking down aluminium window shutters only (area exc 1.0 sqm but not exc 2.0 sqm each)and dismantling all members and reassembling the same with and including new screws, new rubber gasket,new aluminium beads & cleats of existing make and also refixing the handles & mortice locks in existing position with and including new screws including refixing the door shutters in same opening complete all as specified & directed. |
| 45 | Taking down complete existing treatment of roof/ parapet,Mud puska on roof /parrapet including plastering, brick tiles, stone slabs and leeping any thickness including removal etc. complete all as specified and directed. |
| 46 | M&L Brushing neat cement slurry (3 Kg of cement per Sq M) mixed with water proofing liquid in the proportion,water proofing liquid,water & cement (1:4:7) oras per manufacture instructions for bonding of old concrete surface to new concrete complete all as specified and directed. |
| 47 | M&L PCC 1:2:4 type B-0(using 12.5mm graded crushed stone aggregate) mixed with integral waterproofing chemical compoundmixed in proportion 200 millilitre per 50 Kg cement as in padding, benching,Sunken portion etc on roof surface for corecting/making proper slope on roof, etc. complete all as specified and directed. |
| 48 | M & L cutting 75 mm wide and 65 mm deep in brick wall / PCC block / RCC surface any location shaping horizontal facegrooves filled with PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate with and including water proofing chemical compoundmixed in proportion 200 millilitre per 50 Kg cement or as per manufacturers instructions laid when concrete is still green complete all as specified and as directed. |
| 49 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed. |
| 50 | M&L Rendering 10 mm thick in cement mortar 1:4 on concrete / brick surfaces with liquid water proofing compound@ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smoothwithout using extra cement over roof / sunken slab /wall complete all as specified and directed.Note : Water proofing liquid will be measured and paid seperately . |
| 51 | M&L for Water proofing treatment on \"Non approachable / non accessible roof\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer complete all as specified and directed. |
| 52 | (i)Applying approved bituminous based primer conforming to IS : 3384-1995 @ 0.3kg/Sqm to be applied on top surface of prepared surface till the surface is properly impregnated. |
| 53 | (ii)Laying APP (Atactic polypropylenePolymer Modified preffabricated membrane) waterr proofing membrane of weight not less than 3 kg/sqm with minimum 100mm side overlap along the length from downward to upward completely sealed with torch application/hot blown lamps. |
| 54 | (iii)Applying two coats of bituminous based aluminium paint @ 0.3kg/Sqm. |