| Sl. No. | Item Description |
| 1 | Sch \"A\" Part-I (Building Work)Note :This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5. |
| 2 | Total amount of Sch \"A\" Part II (Site clearance, Excavation and Earth work) |
| 3 | Total amount of Sch \"A\" Part III (Internal Water Supply) |
| 4 | Total amount of Sch \"A\" Part IV (Internal Electrification) |
| 5 | Total amount of Sch \"A\" Part V(Path) |
| 6 | Total amount of Sch \"A\" Part VI (Area Drainage) |
| 7 | Total amount of Sch \"A\" Part VII (Sewage Disposal) |
| 8 | Total amount of Sch \"A\" Part VIII (External Water Supply) |
| 9 | Total amount of Sch \"A\" Part IX (External Electrification) |
| 10 | Total amount of Sch \"A\" Part X (Cooling Appliances) |
| 11 | Total amount of Sch \"A\" Part XI (Hot Water Supply) |
| 12 | Total amount of Sch \"A\" Part XII (Rain Water Harvesting) |
| 13 | Total amount of Sch \"A\" Part XIII { ( UG Sump) (Only for RRC)} |
| 14 | Sch \"A\" Part - XIV(Miscellaneous Items for B/R and E/M works)Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as \"Rs 0.00 under col.5 siginifies this fact only. |
| 15 | INTERNAL WATER SUPPLYS&F for two way Angle cock/ angle valve, fancy type, chromium plated, ISI marked with crutch or butterfly handle, screwed down, screwed for iron pipe and fixed to 15mm bore pipeand fixed complete all as specified and as directed. |
| 16 | S&F for 3 in 1 , CP wall mixture for mixing hot and cold water with overhead shower arrangement screwed down for iron pipe and and fixed for 15mm bore pipecomplete all as specified and as directed. |
| 17 | INTERNAL ELECTRIFICATIONM&L for point wiring complete forOne light/Ceiling Fan/Exhaust fan pointcontrolled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , heavy duty PVC conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. |
| 18 | M&L for point wiring complete for One LED light pointcontrolled by two2-way switches with PVC insulated and unsheathed FRLSH cable1.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , heavy duty PVC conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and all as specified and directed.complete .Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. |
| 19 | M&L for point wiring complete for One 5 pin 5 Amp switch socket out let point on an independent board with PVC insulated and unsheathed FRLSH cable2.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , heavy duty PVC conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 2.5 Sqmm PVC FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete for max four nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. |
| 20 | M&L for point wiring complete with PVC insulated and unsheathed, FRLSHcable 2.5 sqmm (nominal area), ISI marked, stranded copperconductor single core including ISI marked 20mm dia PVC conduit concealed in wall and heavy duty PVC conduit in roof/floor slab & ceiling, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm FRLSH cablePVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all for max two nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost. |
| 21 | S&F switch piano flush type 5/6 Amps single pole two way complete all as specified and dierected. |
| 22 | S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSIBin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 centigrade, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed. |
| 23 | S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSIBin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed. |
| 24 | Supply and fixing LED street light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,fixed to pole or wall of building with and including suitableBracket made out of40 mm dia GIlightgrade pipe, 1.20 m long bent to shape by cutting & weldingas required & directed and fixed withtwo Nos of FI clamps 50x6 mm to be tightened with suitable size of bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer, and including connecting the fittingto electric sourcewith & including twin twisted copper flexible wire of size 1.5 sqmm three core with suitable size flexible PVC conduitincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. |
| 25 | S&F for 10 Watt Bulkhead luminaries including LED light driver holder connecting up with 3 core flexible copper conductor cable of suitable size with inbuilt electronic driver duly wired upto terminal block & fixing arrangment for fixing the light fitting complete all as specified & directed. |
| 26 | Supply and fixingBLDC type Ceiling fan 1200 mm sweep five star rated single phase 230V AC, Min 220 CFMwith fan remote , five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling roseincluding PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceilingfan motor not less than 0.5 mtr long for connection complete all as specified.Note:- Necessary Fan hook deemed to be included in item rate. |
| 27 | Supply and fixing 300 mm sweep five star rated Exhaust Fanmade of study engineering plastic body with with louver shutter 230V, 50 Hz , 1200 RPMqresistant to colour change with approved colour andcomplete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipefrom celling rose to exhaust fan motorcomplete all as specified and directed. |
| 28 | S&F MCCB VTPN DB 4 way sheet metal enclosure double door type, 415 Volts AC, with 200 amp rated fully insulated strandad copper bus bar for phase & surrounded with neutral bus bar and two common neutral bars, two earth bar incl cable ties for cable management suitable for housing MCCB/TPN 415Volt as incomer IP-54 protection with metal doors on standard steel sheet of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB & MCCBbut with enclosure blank plates complete all as specified and directed. |
| 29 | Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 4 wayall as specified and directed . |
| 30 | Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 8 wayall as specified and directed . |
| 31 | Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 12 wayall as specified and directed . |
| 32 | S&F MCB TPN 32 amp, 4 Pole, with breaking capacity 10 KA, 415 V AC, 50 Hz with 3 pin & earth plug with socket and one triple pole MCBcomplete all as specified and directed. Note: This item is catered for connection of evaporative air cooler/central air cooling machine |
| 33 | S&F MCCB 4 pole 415 V AC 50 Hz fixed type 125 amps with breaking capacity 25 KA complete all as specified and directed. |
| 34 | S&F MCB SPN 32/40 Amps \"C\" series,10 KA 240 Volts ,AC ISI marked all as specified and directed . |
| 35 | S&F MCB 6-32 Amps single pole,240V/415 V, \"B\" Series, 50 Hz ,ACwith breaking capacity 10 KA , complete all as specified and directed. |
| 36 | M&L submain wiring with two single core 4 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealed in wallsurface / ceiling for sub main connection including 4 sqmm FRLSH one single corePVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 4 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. |
| 37 | M&L submain wiring with four single core 4 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealed in wallsurface / ceiling for sub main connection including 4 sqmm FRLSH one single corePVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Four single core 4 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. |
| 38 | M&L submain wiring with two single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealedin wallsurface / ceiling for sub main connection including one 6 sqmm FRLSH one single core PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. |
| 39 | S& F dish TV cable cord of size 1.5 Sqmm solid copper conductor triple insulated steel wire mesh inner sheathing earth continuity conductor & overall PVC sheathed circular compete all as specified & directed. |
| 40 | M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. belowground level connecting to galvanised earth lead wire 4.0 mm diaas earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixingwith 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and directed . |
| 41 | AREA DRAINAGE M&L Precast M-25 grade epoxy coating factory made RCC \"U\" shape drain block ofsize 450mm width and average depth 600mm as per site condition and wallthickness 80 mmincluding reinforcement as per manufacture instructioncompleteall as specified and directed. |
| 42 | M&L Precast factory made reinforced cement concrete cover slab M-25 of thickness 130 mm including reinforcement as per manufacture instruction completeall as specified and directed. |
| 43 | SEWAGEDISPOSAL Supply & laying 200 mm internal dia double walled corrugated pipe (DWC pipe) Class SN8 (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth external annular corrugatedand smooth internal surfaces for non-pressure undergound Sewerage & Drainage application confirming to IS: 16098-2013 including all materials labours, T&P required for proper completion of work,laid and jointed etc complete all as specified and directed. |
| 44 | M&L for RCC Septic tank designed to carry sewage and sullage water, excavationin any type ofsoil,PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls andRoof Slabincluding beams etcwithVent shaft , manhole openings with cover connectionetc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users.As per TD-CELZ/TD-750 Sheet No 1/2 and 2/2 complete all as specified and directed. |
| 45 | Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size (2.4 M dia x 3.0 M effective depth). As per TD-CELZ/TD-576 Sheet No 1/2 and 2/2 complete all as specified and directed. |
| 46 | EXTERNAL WATER SUPPLY Cutting existing CI/GI pipe line 150 mm dia for insertion of tee of size 150 x 150 x 80 mmfor branch connection including excavation and earth work complete |
| 47 | Cutting existing GI/DI pipe line 150 mm dia for insertion of tee of size 150 x 150 x 50 mmfor branch connection including excavation and earth work complete |
| 48 | M & L in replacement of NRV cast iron both ends flanged, 150 mm bore ISI marked and incl all nuts bolts, sheet and gaskets etc including taking out old existing unservicable NRV complte all as specified and directed |
| 49 | M&L in replacement of 80 mm dia sluice valve class PN-1.6 heavy duty flanged ends drilled , ISI-marked confirming to IS:14846 suitable for following bore pipe, wheel oprated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valveincl. making arrangement for safe working all as specified and directed. |
| 50 | Construction of Sub-class \"B\" brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work,750cm x 750cm x100cm thick base for foundation with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, 230 mm thick brick work in cement mortar (1:6), 10 mm thick rendering in cement mortar (1:4)on internal & exposed surfaces including mild steel sheet cover ofsize 0.75m x 0.75m x 3mm thick and angle iron of size (30 x 30 x 5) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface including necessary earthwork & demolition of existing old valve pit complete all as specified and directed. |
| 51 | Construction of Sub-class \"B\" brick masonry valve pit chamber of size 600 mm X 600 mm X 600 mm (internal dimensions) including necessary excavation & earth work,750cm x 750cm x 100cm thick base for foundation with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, 230 mm thick brick work in cement mortar (1:6), 10 mm thick rendering in cement mortar (1:4)on internal & exposed surfaces including mild steel sheet cover of size 75cm x 75cm x 3 mm thick and angle iron of size (30 x 30 x 5) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface including necessary earthwork & demolition of existing old valve pit complete all as specified and directed. |
| 52 | Supply, install, testing and commissioning electric driven submersible pump set horizontal tpe 5 HP 3 Phase 415 Volts 50 Hz with suction and delivery 80 mm dia pipe dishcharge capacity capacity 9.60 lts/sec at with head not less than 24 mtrincluding necessary accesssories for fixing arrangement complete all as speciffed and directed. |
| 53 | Supply and fixing submersible cable PVC insulated flat copper conductor multistranded of size 4 Sqmm 3 core complete all as specfied and directed. |
| 54 | Fabrication, supply, installation, testing and commissioning of outdoor type LT feeder pillar box of over all size 1.20 x 0.75 x 1.0 mwith with front and rear opening doors with electrolysis Aluminium bus bars of 1 ½ times of the incoming capacitywith provision of extension, dust and vermin proof, cubical, cable alloy for all the feeders, panel fabricated out of 3.15 mm thick CRCA sheet (CPRI tested type) duly pre-treated and powder coated, factory fabricated panel and consisting of the following and as specified and directed:- Incominga)Incoming - MCCB4P 100 amps, adjustable thermal & magnetic setting 16 KA , 415 volts, 50Hz, Ics=100% Icu- 01 Nob0DOL starter suitable for pump and motor 3 phase 415 Volts 50 Hz AC-02 Nos(d)S&F Digital Panel mounted Ammeter 96 mm square type complete with selector switch complete with suitable size of CT\"s - 01 Set (e) S&F Digital Panel mounted Voltmeter 96 mm square type complete with selector switch - 01 No(f) S&F Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(g)S&F RYBLED indicating lamp - 01 set. |
| 55 | EXTERNAL ELECTRIC SUPPLY :M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installationand including glands and with 4 terminals for terminating oneincoming and outgoingUG cable of size 10/6 sqmm 2 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and boltswith suitable busbarall as spcd and directed. |
| 56 | Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 09 mtr long, all as specified and shown on drawings including the followings:-(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:3:6) type D-2 using 20 mm graded stone aggregate as in coping including form work complete. (d)Painting of poles externally with two coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.(e) Painting of coping shall be cement base paint complete all as directed.(f) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed.Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately. |
| 57 | Supply, installation, testing and commissioning in replacement of out doortype LT Feeder pillar box size0.90 m x 0.75 m x 0.45 m in depth made out of 3.15mm thick CRCA sheet ( CPRI type tested) and MS structural section of 50 x50 x 6 mm comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted onsuitablebus bar insulators, 200 Amps rating suitably drilled and tapped for bolts withopenable two part front and rear shutter,hinged front and rearpanelsand locking arrangement, bottom plate provided with the requires numbers of cable entries / opening including cable glands and cable lugs with heat strinkable PVC sleeving having RYB-B colour code ,powder coated painting complete embedded in PCC 1:3:6 type C-2 ( using 40 mm graded aggregate ) n. exc. 0.45 cumand provision of following accessories complete all as specified and as directed ( Note :-MCCB will be measured and paid separately.) |
| 58 | S & F MCCB of 160 Amps, 4 pole, 415 volts, 50 Hz25 KA breaking capacitywith adjustable thermal magnetic release with spreader link on both sides complete all as specified and directed. |
| 59 | Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 32x6 mm as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 40 mm pipemedium grade for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore GI Pipe medium grade for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. |
| 60 | Supply and laying Galvanised Iron pipe light grade on Road, drain, culvert, roof and wall of dia 50 mm for protction of cable complete all as specified and directed. |
| 61 | COOLING APPLIANCES Supply, installation, testing & commissioning of Air cooler 5 star rating of capacity 30000 CMH, 3 KW , 3 Phase, 415 Volt, 50 Hz, 1440 RPM, noise DB < 79 made of engineering plastic injectio moulding body top/down discharge including dust filter, water tank should not less than 60 Ltr with water drain feature on auto/manual mode and installation of all connected items i.e double deflection grills of suitable size and Nos including GI Ducting (22 Gauge) with canvas/thermal insulation alongwith three phase electrical connection, mounting arrangement of Air Coller on MS structure complete all as specified and directed. |
| 62 | Supply, installation, testing & commissioning of Air cooler 5 star rating of capacity 22000 CMH, 1.5 KW , 3 Phase, 415 Volt, 50 Hz, 1440 RPM, noise DB < 79 made of engineering plastic injectio moulding body top/down discharge including dust filter, water tank should not less than 35 Ltr with water drain feature on auto/manual mode and installation of all connected items i.e double deflection grills of suitable size and Nos including GI Ducting (22 Gauge) with canvas/thermal insulation alongwith three phase electrical connection, mounting arrangement of Air Coller on MS structure complete all as specified and directed. |
| 63 | Supply, installation of LT DRIVEN SIELENT Exhaust fan 5 star rating of capacity 10000 CMH, 1400 RPM,3 Phase, 415 Volt, 50 Hz, power consumption 0.37KW with auto shutter feature and size not more than 650x650x460mm includingthree phase electrical connection with necessary opening in the wall for fixingthe same complete all as specified and directed. |
| 64 | Supply & installation of PVC grill of size not less than 8\" x 16\"to allow the airflow inside the building and ensuring comfort in interior space complete all as specified and directed. |
| 65 | Supply and fixing ofheavy duty Water cooler storage type, ISI marked, electric dirven 230 Volt, 50Hz, single phase, complete with all internal accessories stainless steel body and tank, power saving PUF insulation as stable cold water thermal steel , 10 degree to 25 degree autocut facility, overload protection, stainless steel front panel, extended plasctic leg, eco- friecly verson with non CFC refrigerent, energy eficient, confirming to relevant IS and PF shall not be less than 0.85 comprassor and approximet storage capacity of 180Ltr and nominal cooling capicty of 150Ltr/ Hourcomplete all as specified and directed.Note for Air COOLER& Water COOLER Items:-(a)Minimum warranty 2 years on product, 10 years on compressor & 5 years condensor .(b)Item mfg date should not be older than 06 Months from installation date.(c)All items must have a permanent type vinyl sticker on outer body bearing following details and quoted rate are deemed to inclusive cost of sticker.(i)Machine Srl No._____________ (ii)MES No______________ (iii)Date set to work.____________(iv)PRB Page No ______________.(v) Location__________________(vi) CA No.________________________ |
| 66 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 0 .5 KVA complete all as specified and directed. |
| 67 | Supply and fixing mild steel strucural work including welding work as per site requirement for mounting the PVC Water tank (Make up tank) as per air coller requirement complete all as specified and directed. |
| 68 | HOT WATER :Supply and Installation of Solar water heating system ,Flat plate collector type ,with heat exchanger of 200 litre per day capacity ,with electrical heating back up complete all as specified and as directed. |
| 69 | RAIN WATER HARVESTING :M&L loose filling with pea gravel of size 1/18\" to 3/18\" to as in filter bed of approved quality complete all as specified and directed. |
| 70 | Drilling of hole in any kind of soil /strata by mechnical percussion or rotary ring method below GL including electric loging through any type of strata soil/rock disposal of soil within 10 mtr keeping space for pea gravel packing and including loweringand extraction of perforated PVC pipes of dia 200mm complete all as specified. |
| 71 | S&F Perforated PVC pipe 200mm dia in any length and fixed in any position including inverted earthen pots with holes on top complete all as specified. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy