| 1 | EARTHWORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 3 | Excavating, supplying and filling of local earth (including royalty) bymechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete |
| 4 | CONCRETE WORK |
| 5 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from naturalsources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) |
| 6 | Reinforced Cement Concrete |
| 7 | FORM WORK Centering and shuttering including strutting, propping etc. and removalof form for Foundations, footings, bases of columns, etc. for massconcrete Footing Bases of Column |
| 8 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 9 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 10 | DESIGN MIX CONCRETE |
| 11 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 13 | Steel Reinforcement |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | FLOORING |
| 16 | Dry brick on edge flooring in required pattern with bricks of classdesignation 7.5 on a bed of 12 mm mud mortar, including filling jointswith Jamuna sand, with common burnt clay non modular bricks. |
| 17 | 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete. |
| 18 | MASONRY WORK |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 20 | HALF BRICK MASONRY |
| 21 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | FINISHING |
| 23 | PLASTER 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 24 | 12 mm cement plaster finished with a floating coat of neat cement ofmix :1:4 (1 cement: 4 fine sand) |
| 25 | PAINT |
| 26 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :13.41.1 New work (two or more coats) over and including waterthinnable priming coat with cement primer |
| 27 | With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/steel works |
| 28 | Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 29 | STEEL WORK |
| 30 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Using 48.3MM OD ( 3.2 MM Thick & 3.56KG/Mtr) |
| 31 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 32 | ROOFING |
| 33 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shapewherever required |
| 34 | Providing and fixing precoated galvanised steel sheet roofingaccessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester topcoat 15-18 microns using self drilling/ self tapping screws complete :12.51.1 Ridges plain (500 - 600mm) |
| 35 | Providing & fixing false ceiling at all height including providing &fixing of framework made of special section, power pressed fromM.S. sheets and galvanised with zinc coating of 120 gms/ sqm(both side inclusive) as per IS : 277 and consisting of angle cleat ofsize 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at1200mm c/c, one flange fixed to the ceiling with dash fastener12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleatfixed to the angle hangers of 25 x10 x0.50mm of required lengthwith nuts & bolts of required size and other end of angle hangerfixed with intermediate G.I chanels 45 x15 x 0.90mm running at thespacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each havinglips of 10.5mm, at 450mm c/c, shall be fixed in a directionperpendicular to G.I intermediate channel with connecting clip madeout of 2.64mm dia x 230mm long G.I wire at every junction, includingfixing perimeter channels 0.50mm thick 27mm high having flangesof 20mm and 30mm long, the perimeter of ceiling fixed to wall/partitions with the help of Rawl plugs at 450mm centre, with 25mmlong dry wall screws @ 230mm interval, including fixing of CalciumSilicate Board to ceiling section and perimeter channels with thehelp of dry wall screws of size 3.5 x25mm at 230mm c/c, includingjointing & finishing to a flush finish of tapered and square edges ofthe board with recommended jointing compounds, jointingtapes,finishing with jointing compounds in three layers covering upto 150mm on both sides of joints and two coats of primer suitablefor boards, all as per manufacture\"s specification and also includingthe cost of making opening for light fittings, grills, diffusers, cut outsmade with frame of perimeter channels suitably fixed, all completeas per drawings, specificaton and direction of the Engineer in chargebut excluding the cost of painting with: mm thick Calcium Silicate Board made with Calcareous& Siliceous materials reinforced with cellulose fibermanufactured through autoclaving process. |
| 36 | DEMOLITION WORKS |
| 37 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 metres lead as per direction of Engineer - in- charge. |
| 38 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. |
| 39 | Dismantling steel work in built up section in angles,tees,flats and channels including all gusset plates,nuts,cutting rivets,welding etc.including dismembering and stacking within 50metres lead water tank with stagging L/S=7400 kg |
| 40 | INTERNAL ELECTRICAL WORKS (CPWD DSR 2018 E&M) |
| 41 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 42 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sq.mm+1x1.5 sq.mm earth wire |
| 43 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 44 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 180 mm X100 mm X 60mm deep |
| 45 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module (125 mm x 125 mm) |
| 46 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 47 | 3 pin 5/6 A socket outlet |
| 48 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole |
| 49 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 50 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 51 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 52 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Please Enable Macros to View BoQ information |