| Sl. No. | Item Description |
| 1 | Building Work |
| 2 | Design, fabrication and assembly for provision of (factory made) precast underground utility structures of 6 m wide x 4.2 m high x 9 m long With 1m corridor and retaining wall on 3 sides as per the Drawing attached at various locations. (As per Dwg attached) Steel work in Standard I & Channel Section (Fe350) along with Tubular (round, square or rectangular hollow tubes of grade YST 310 etc. trusses,Fabrictaed I section/ Box sections in plates with adequate stiffners for composite/ non composite actions with concrete, Shear studs to be provided and welded as per structural drawings. , sky light, facade frame work, portal frame work, column, runner, purlin , paragola or similar location etc., including cutting, hoisting, fixing in position at all heights and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(Holding down bolts and chemical HILTI anchor or equivalent) |
| 3 | SWT 110KL |
| 4 | Design and Construction 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | SENTRY POST |
| 6 | Design and Erection of Santry Post with PPGI Sheet, MS Sections, Play Board etc (internal electrical & water supply shall be measured in respective schedule |
| 7 | PUMP HOUSE |
| 8 | Construction of Pump House with Operator room and attach toilet of size 10m x 6m = 60 Sqm as per permanent specs & drg complete all as specified and directed by Engr in Charge |
| 9 | GENR SET ROOM |
| 10 | Construction of Genr Set Room 5.46m x 6.46m = 35.27 Sqm as per permanent specs & drg complete all as specified and directed by Engr in Charge |
| 11 | RCC SEMI UG SUMP |
| 12 | Design and Construction of RCC UG Sump of capacity 200 KL complete as per permanent specification complete all as specified and directed by Engr-in-charge |
| 13 | DEMOLITION AND DISMANTLING WORK |
| 14 | Demolition of cement concrete (reinforced) in ground floor and pavings n exc 15cm thickness (below or above ground level) |
| 15 | Dismantling of framed timber scantlings 40 Sqcm over in section, in any position |
| 16 | Dismantling boarding, any description, fixed in any position with nails |
| 17 | Dismantling structural steel work including doors, gates but exc framed truss etc |
| 18 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness incluing Nainital or similar pattern roof coverings / wall claddings |
| 19 | Taking down chowkhats (window/door) or frames with shutter (without taking off shutters from the frame) n exc 1.50 Sqm each complete as specified and directed |
| 20 | Taking down chowkhats (window/door) or frames with shutter (without taking off shutters from the frame) exc 1.50 Sqm and n exc 4.00 Sqm each complete as specified and directed |
| 21 | LOADING RAMP |
| 22 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 24 | M&L for Brick work in CM 1:4 using Fly ash brick complete as specified and directed |
| 25 | Providing and laying in position machine batched and machine mixed design mix 1:2:4 cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering work, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. |
| 26 | FLAME PROOF LIGHTING |
| 27 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross-sectional area, single core PVC insulated (FRLS), unsheathed multistrandedcopper conductor cable 1100 Volts gradedrawn through and includingrigid stove enamelled steel conduit of suitable sizemedium grade and accessories ISI marked for flame proof wiring incl steel flexible pipe, Jnction box/terminal boxfor connection the fittings and1.5 Sqmm nominal cross sectional area, single core PVC insulated (FRLS), unsheathed multistranded copper conductor cable earth continuity wire to common earth and connected to earth dolly for one light / fan point controlled by one switch complete all as specified and directed |
| 28 | M&L Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed |
| 29 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 30 | Supply and fixing Flame proof DB of 2 Way including flame proof MCB SPN of capacity 16 Amp complete all as specified and directed |
| 31 | Supply and fixing flame proof exhaust fan of capacity 300 mmsweep 230 V, 50 Hz including fixing of louvers complete all as specified and directed |
| 32 | LIGHTING PROTECTION |
| 33 | M&L in replacement earthing complete with Copper earth plate electrode size 600X600X3.15 mm thickburried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including copper earth strip 20x3 mmby means of bolts ,nuts, check nuts & washers ofgalvanised iron and connected to test point all asshown in electrical plate No 3 of Sl part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm gradedcrushed stone aggregatereinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GIprotection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. NOTE :- copper earth strip 20x3.15mm and protection pipe beyond 7.5 metre will be measured and paid separately. |
| 34 | FENCING AND GATE |
| 35 | M&L for Cement concrete type D2 1:4:8 using 40mm graded aggregate in foundations, filling and massconcrete |
| 36 | M&L posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 37 | M&L mil steel bars 10mm dia and over cut to length, bent to shape required including cranking etc conforming to Fe-410W Gde E-165 |
| 38 | Supply only MS chain link fencing any size or type complete all as specified |
| 39 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire |
| 40 | S&F MS screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long |
| 41 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm diabarbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ingbolts, including, securing or tying at crossings etc as directed |
| 42 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified |
| 43 | Removal excavated land material exc 250mtr but n exc 500 mtr and depositing where directed |
| 44 | FIRE FIGHTING SYSTEM FIRE PUMPS, SUCTION AND DELIVERY, CONTROL PANEL |
| 45 | Supply, install and testing Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with \"range of operation\" 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply 70m Head. 1260 LPM discharge complete all as specified and directed. |
| 46 | Supply and fix Mild Steel class \"C\" diesel pump exhaust pipe 150mm dia with one layer of 10mm thick asbestos rope insulation and including all fitting clamp/ structural steel supports complete all as specified and directed |
| 47 | Supply, install and testing Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with \"range of operation\" 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 70m Head, 1620 LPM discharge. (Note : VFD drive or multistage pump arrangment shalll be provided to control high pressure at lower floors FHC upto last bunker |
| 48 | Supply, install and testing Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start/stop operations for 440 V, 3 phase, 50 Hz 70 m head 180 LPM discharge complete all as specified and directed. |
| 49 | Supply and fix footvalve conforming to IS of250mm dia size complete all as specified and directed |
| 50 | Supply and fix strainer Y-type conforming to IS of 250mm dia size complete all as specifed and directed |
| 51 | M&L for fabrication of water suction/delivery header pipe using C-Class MS pipe of suitable size/dia as required at site, provided with both end flanged dead plugs for future extensions if any, havingminimum two nos 20-25cm long flanged inlet suction water pipe connections using suitable size MS pipe and heavy duty drilled flang, and minimum four or more Nos 20-25cm long flanged delivery water pipe connection points using suitable dia size MS pipe and heavy duty drilled flang including all necessary cutting drilling, welding work as per site requirment and necessary accessories like drilled flanges, blank flangefor dead plug, flanged reducers/tapers, 15mm socket end nipples for connection of water pressure guage, suitable size GI Nut, Bolts, washers, rubber gaskets, PCC or brick work for support to header pipe etc including making necessary inlet and outlet pipe connections using special pipe fittings all as directed and specified.Note : Suitable dia MS pipe with special fittings if any required shall be measured and paid separately under relavant item. However cost of rubber gaskets, GI Nut, bolt and washer shall include in quoted rates. |
| 52 | Supply, Installing & testing and commissioning LT starter panel, 6 Zone control for automatic operation of fire pump with digital programmble controller module forfire fighting electric supply control, factory made Indoor type floor mounted, LT panel Cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Copper bus bar 400 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.0mm thick Stainless steel sheet and 40 x 40 x 5mm thick angle iron frame work, both front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 6 Sqmm. The scope of work includes the following :- |
| 53 | INCOMMING :-(a) MCCB 4 Pole 315 amps ,415 Volt of breaking capacity 36 KA (Ics=100 % of Icu) with Adj Thermal & Fixed Magnetic Type - 01 Nos(b) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio as per Legrand Cat No MIM15- 01 Nos(c) LED Indicator lamp (R,Y,B) - Set of Three.(d) 6-Zone fire fighting controllar electronic type with suitable accessories-01 NosOUTGOING :-(e) Star-delta starter suitable for automatic & manual operation of electric driven main C/F fire pump through low/high water pressure switch controller including MCCB FP 160A, 25kA, 415V, Digital Volt-Amp meter, SPP, pump ON/OFF LED indicator, auto/manual rotary switch, ON/OFF push switch etc - 02 Nos.(f) Star-delta starter suitable for automatic & manual operation of electric driven Jocky fire pumpthrough low/high water pressure switch controller including MCB FP 40A, 25kA, 415V, Digital Volt-Amp meter, SPP, pump ON/OFF LED indicator, auto/manual rotary switch, ON/OFF push switch etc- 01 Nos.(g) Star-delta starter suitable for automatic & manual operation of electric driven Terrece Booster fire pumpthrough low/high water pressure switch controller including MCB FP 40A, 25kA, 415V, Digital Volt-Amp meter, SPP, pump ON/OFF LED indicator, auto/manual rotary switch, ON/OFF push switch etc - 01 Nos. (h) Digital controllar, 240VAC/12VDC, for automatic/manual operation of disel engine driven fire fire pump,through low/high water pressure switch controller, including Engine ON/OFF LED indicator, auto/manual rotary switch, ON/OFF push switch etc including backsupply connection from DC battery for smooth auth operation of DG set on mains supply failure- 01 Nos.(j) MCB SPN 25 amps, 10kA, 415 Volt, C-series - 02 Nos (light load) |
| 54 | FIRE HYDRANT AND PLUMBING WORK |
| 55 | Supply and fix Dual plates CI wafer type check valve(high pressure NRV), tested to pressure of 15Kg/ Sqcm complete set for following bore dia pipes :- |
| 56 | (a) 150mm dia size |
| 57 | (b) 100mm dia size |
| 58 | (c) 80mm dia size |
| 59 | Supply and fix Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm. |
| 60 | Supply and fix Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows, Air release valve etc and all accessories complete. |
| 61 | Supply & fix fire hydrant landing valve type-A (double head outlet) of 63 mm dia conforming to IS 5290. |
| 62 | Supply & fix fire hydrant landing valve type-B (double head outlet) of 63 mm dia conforming to IS 5290. (01 Each bldg GF FHC) |
| 63 | EXTERNAL FIRE BRIGADE INLET CONNECTION |
| 64 | Supply and fix MS cabinet (approx not less than 750mm x 600mm x 450mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete |
| 65 | M&L for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6.30 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 32 X 6mmGI earth wire as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mmc/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work includinglaying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion..(Note : 1.If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt.) |
| 66 | FIRE EXTINGUSHER FOR PUMP HOUSE AND POWER HOUSE, G/F OPERATOR ROOM :- |
| 67 | Providing and fixing 6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged all as specified and as directed. |
| 68 | Providing and fixing CO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket complete all as specified and as directed. |
| 69 | Providing and fixing 9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged all as specified and as directed. |
| 70 | EXTERNAL ELECTRIC SUPPLY |
| 71 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed |
| 72 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core |
| 73 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core |
| 74 | Supply and fix LED street light 35/36 W IP 65 complete with all connected accessories |
| 75 | Design, Supply, Installation,Testing and commissioning of LT weather proof panel (1200mmx1200mmx500mm)board outdoor type powder coatedoutdoor type double door shutter, made out of CRCA 3.15 mm thickouter and 2 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminiumbus bar 200 ampswith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved, indicator lamps R-Y-B, selector switches and internal wiring including making PCC foundationheight not less than 0.6 Mtr above ground level and 0.3 mtr below ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etc. The bottom portion of enclosure shall be minimum 0.6 mtr above ground level and 0.3 mtr below ground level of legs of angle iron ).The panel should have Busbar clearance of 25 mm for Ph to Ph and 19 mm for Ph to neutral, Zero Stray voltage doors and panels, polyster glass support for insulation. The cable alleys should be 300 mm wide and it should be fitted with hinged door that open up to and angle of 95 Deg. The provision of cable entry should be from Bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B asForm of sepration. Panel should be suitable for sesmic zone V. The panel should be equiped with suitable size of CT and display meter for VAF measurement. (a) Aluminium bus bar capacity 200 Amps for Phase-R-Y-B-3 Nos & neutral -4 Nos (b) MCCB FP 36 KA 160 Amps- 1 Nos(I/C)(c) MCCB FP 16 KA 32 Amp - 03 Nos (Outgoing)(d) MCB TPN 10 KA32 Amps - 02 Nos (outgoing) (d) Street light timer digital type - 01 Nos including contactor and necessary accessories for function of timer(e) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-200 Amps (g) complete control panel wiring withstranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder(f) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwithselector switch - 01 No 0-500 V |
| 76 | Supply,Installation,Testing and commissioning of LT weather proof Feeder Piller panel (450mmx450mmx15mm)board outdoor type powder coatedoutdoor type hingeddoor shutter, made out of CRCA 3.15 mm thickouter with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminiumbus bar 100 ampswith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply including 63 Amp MCCB TPN 16 KA complete. |
| 77 | Earthing complete with Chemical earthing with copper earthplate 90x60cmx5mm & copper earth strip 32x6mm, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to copper earth strip of size 20 x 3 mm by means of bolts, nuts, check nuts and washers of copperall as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 78 | M&L for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6.30 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 32 X 6mmGI earth wire as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mmc/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work includinglaying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion..(Note : 1.If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt.) |
| 79 | S&F in replacement of existing loop in-out junction box with non metalic PVC junction box suitable of size 350mm x 250mm with connector 4 way and including one MCB SP 6 A, 230V alongwith 2 Nos \"C\" Clamps and back clamp made up of 20x3 flat iron and fixing on pole with necessary nuts bolts, washers, 2 Nos cable glands of size not exc 4 core 25 sqmm, Cable lugs as required complete including taking down old UNSV boxes all as specified and as directed. |
| 80 | Supply and fix LED flood light 70 W IP 65 complete with all connected accessories |
| 81 | M&L for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6.30 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 4 mm diaGI earth wire as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mmc/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work includinglaying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion..(Note : 1.If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt.) |
| 82 | M&Llocal sand dry, filling in trenches around under ground cable complete all as specified and directed. |
| 83 | Material and labour for laying DWC (Double wall corrugated ) pipe conforming or IS 16205 (electric cable use)of nominal outer dia 50 mm and inner dia 38mm for laying electrical cables under trenches / under road/ wall complete all as specified and directed. |
| 84 | EXTERNAL WATER SUPPLY |
| 85 | Supply, installation, testing and commissioning ofSubmersible pump, electric driven 415 V, TP suitable for lifting of water from SWT supply and Install complete upto 3 HPcomplete all as specified and directed. |
| 86 | S&F Submersible starter panel of suitable sizemade out of CRCA sheet of 3.15 mm thick out door type automatic star delta starter suitable for 5 HP with contactor, control MCBs, phase preventor, timer relay etc including necessary foundation for erection of starter panel complete all as specified and directed |
| 87 | Supply and connecting flat submersilbe cable suitable for 3 HP submersilbe motor 3 core of size 4 Sqmm complete all as specified and directed |
| 88 | FIRE ALARM |
| 89 | Supply and fixing of fire extinguisher dry Misttype 6 ltrs capacity including fire ball 06 Nos of capacity 1.3 Kgs complete all as specified and directed |
| 90 | Supply and fixing of fire alarm and smoke detector and connected networking work including control panel of each bunker, wireless remote hooters and duty room control panel complete |
| 91 | STANDBY SUPPLY |
| 92 | Supply, installation, testing and commissioning of Silent DG set 82.5 KVA, 3 phase 4 wire , 415 volts , 1500 RPM, 50 Hz power supply with power factor 0.8, coupled directly to alternator mounted on a common base frame plate suitable forcomplete with integral acoustic enclosure having silent features to withstand all weather conditions and for outdoor application with AMF Panel. The design of the DG set shall confirm the CPCB IV+ norm/ regulation with fuel tank, battery and standard accessories, PCC foundation siutable to mount DG set as per size recommended by OEM and the height of the plinth shall be 45cm above the ground level all as specified and directed with the following specifications. Note: Contractor shall submit the detailed OEM drawing for approval of Engr-in-Charge.(a) ENGINE: Diesel engine of suitable capacity to match the 82.5 KVA alternator under NTP conditions with provision of 10% overload for 1 hour in every 12 hours running. The engine shall consist of following: (i) Fly wheel (ii) Radiator, Air to Air after cooler, pusher fan & fan drive arrangement. (iii) Dry type air cleaner with restriction indicator (iv) Fuel injection system (v) Radiator fan (blower type) with guard (vi) Gear driven water pump (vii) Fuel filter (viii) 12 V DC electrical starting system (ix) Exhaust silencer heavy duty residential type (x) First fill of lubricating oil (xi) Sensors for oil pressure, coolant temperature & level.(b) Control panel: The control panel with microprocessor based DG Set controller for engine and alternator parameter in one console including complete internal wiring and shall confirm dust proof & vemin proof. The control panel consists of the following parts: (a) Auto start control module with Auto Mains Failure control module as per latest version. (b) MCCB of adequate rating. (c) Indicating lamps for DG ON, Mains ON, Load on DG, Load on Mains etc.(d) Key switch (e) Set of current transformers and MCBs (f) Controller shall monitor and display the engine speed, oil pressure, coolant temperature, frequency, voltage, current, power factor and fuel level, battery voltage and modules for comprehensive engine and alternator protection, display the array of warning, electrical trip and shutdown alarm. The controller shall provide a record of most recent fault conditions. Fault history stored in the control non volatile memory. (g) Emergency stop : Annuciated whenever an emergency stop signal is received.(c) Alternator: Alternator self excited, self regulated brushless single bearing alternator 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz coupled to engine with consisting of following parameters. (i) Type : Self excited self regulated with automatic voltage regulator (ii) Rating 82.5 KVA at 0.8 PF lagging. (iii) Speed : 1500 RPM (iv) Connection: Star conenction (v) Ventilation: Self Ventilated. (vi) Insulation: Class \"H\" (d) AMF Panel : The AMF Panel outdoor type suitable for 82.5 KVA DG set factory fabricated, floor mounted, front operated, totally enclosed dust and vermin proof with suitable Incomer and Outgoing MCCBs 4 pole type, CTs, Indicating lamps LED(RYB) for Incoming/Outgoing, Illuminating push buttons with elements LED type with NO/NC, Digital MFM3 phase 415 V AC - 01 Each, battery charger of suitable capacity, AMF controller 12V DC - 01 Each, Aux relay/coil voltage of suitable capacity complete. |
| 93 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 3.5 core 120 sqmm |
| 94 | Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting framesuitable size for fixing the I/C & O/G MCCB mentioned below made out of angle iron 45 x 45 x 6 mm and four numbers of 250 Amps aluminum strips / bars duly insulated on insulators - 4 Nos / suitable size Bakelite sheet, free space between MCCBs / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel as required, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires of suitable size and comprising and including the following :(A) Main Incoming(i) MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 160 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA - 01 No.(ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs(iii)LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set(B) Main Outgoing(i) On-load changeover switch 100 Amp 4 pole - 01 Nos(ii) MCCB conforming to IS:13947 (Part-II), IEC-947, TP (3 pole), 63 Amps, 415 volts, 50 Hz, rupturing capacity 26 KA - 02 No. (ii) MCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 32 Amps, 415 volts, 50 Hz, rupturing capacity 10 KA - 04 No. |
| 95 | M&L for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6.30 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 32 X 6mmGI earth wire as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mmc/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work includinglaying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion..(Note : 1.If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt.) |
| 96 | M&Llocal sand dry, filling in trenches around under ground cable complete all as specified and directed. |
| 97 | ROAD PATH AND CULVERT |
| 98 | M&L for soiling (or sub base) 150mm thick spread thickness with broken boulders, 80 to 40mm size interstices filled, surface formed and rolled to required level, camber, gradient all as specified and directed. |
| 99 | Rolling and consoildating formation surfaces with 8 to 12 ton power roller complete all as specified and directed |
| 100 | M&L for 150mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in sub base of floors etc, complete all as specified and directed. |
| 101 | M& L for 200MM thick PQC controlled (quality) cement concrete of minimum flexural strength of 40 Kg per Sq Cm in field at 28 days loswer control limit (LCL) in pavement slabs using minimum 400Kg of cement per cubic metre laid in bays to required gradient and camber including necessary form work and using full width fully mechanised pavar complete all as specified and directed |
| 102 | Supply only polyster triangular fibre as secondary reinforcement all types of concrete and mortar (@0.25% by wt of cement) |
| 103 | M&L Forming 20mm wide expansion joint filled with pre-formed compressible synthetic filler board , applying bond breaker tape on top of filler board HD 100 for complete width of joint , provision of closed cell polyethylene back up rod 28mm to 30mm dia filled with polysulphate or polyurethane based sealant (minimum depth of sealent above backup rod shall be 20mm), priming the side and applying masking tape on edges of jointto prevent accidental spillage of sealant and removing the masking tape after sealant is appied for thickness of concrete slab complete all as specified and as directed. The sealant shall conform to IS-5818 and MAV of +30% with 10 years warranty. |
| 104 | M&L Forming contraction/dummy joints 70mm deep and 6mm wide (using diamond cutter) and top 13mm (minimum above back up rod) filled with polyurthane sealent and priming the sides with two coats of primer provision of closed cell polyethelene back up rod 8mm dia and applying masking tape on edges of joint to prevent accidental spillage of sealent on top surface and to give a neat finished to the sealent and removing the masking tape after sealent is applied complete all as specified and as directed. The sealent shall comform to IS-5818 and MAV of +30% with 10 years warranty. |
| 105 | M&L Forming contraction joint 10mm wide and 80mm deep for quality concrete slab, cleaning the complete joint and top primed with primer and filled 10mm with polyurthane thermo setting type sealent over 10mm deep polythene back up material and pasting polythene adhesive tape all along on the both edges of joint and removing the same after filing and tooling the material inside the joint to remove spilled over material complete all as specified and directed. |
| 106 | M&L finishing surface of concrete roads, pavements but by brooming complete all as specified and directed |
| 107 | Forming embankments incl raising earth spreading levelling in layers n.exc 30 cm thick etc all as specified |
| 108 | Removing of excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point |
| 109 | Supply and fixing delinators of MS pipe 45 mm dia 900mm long with top 230 mm provided with flurescent tape and covered with wire mesh 90 mm dia and 300 mm long embedded in PCC 1:2:4 along side road complete all as specified and directed. |
| 110 | AREA DRAINAGE |
| 111 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm.complete all as specified and directed. |
| 112 | Removing excavated material soilnexc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified. |
| 113 | M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 114 | M&L Cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 115 | M&L Cement concrete 1:2:4, type B-1(using 20mm graded stone aggregate) in surface channels and drains complete all as specified and directed. |
| 116 | M&L Pre-cast cement concrete 1:3:6 type C-1(using 20mm graded stone aggregate) block masonrywith solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and directed. |
| 117 | M&L Extra for forming 40 cm inner girth fair finished drains or channels i.e. exc 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 118 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping including formed work complete all as specified. |
| 119 | M&L Rendering 15mm thick in cement mortar 1:4 on fair faces of brickwork or concrete surfaces and finished the surfaces even and smoothcomplete all as specified and directed. |
| 120 | RETAINING WALL |
| 121 | M&L PCC 1:4:8 type D2, using 40mm graded stone aggregate as in Cement concret in foundations\" filling and mass concrete complete all as specified. |
| 122 | M &L forRCC M-25 design mix as in footing, foundation beams, plinth beams, bases of columns complete all as specified and directed. |
| 123 | M&L for RCC M-25 design mixas in walls, retaining walls, basement walls, ballast walls and the like of any thickness above top of footing including attached pilasters and buttresses and making necessary weep holes including PVC pipe complete all as specified and directed. |
| 124 | Use and waste of form work to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to batter, flat, rough finish surface of concrete complete all as specified and directed. |
| 125 | Use and waste of form work to walls, retaining walls, basement walls, ballast walls and the like including attached pilasters and buttresses and similar work vertical or to batter, flat, fair finished surface of concrete complete all as specified and directed. |
| 126 | S&F mild steel TMT bar 10 mm dia and over, as in reinforcement, cut to length, bent to shape etc, including binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 127 | S/F 110 mm dia PVC (SWR) pipes single socketed fixed in walls and floors or trenches etc. as in weep holes of retaining wall complete all as specified. |
| 128 | M&L hand packing broken stone or boulders (any thickness) at back of walls over arches andraising (or lowering) to the required level complete all as specified |
| 129 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as specified and directed. |
| 130 | Removing excavated soil n exec. 50m and depositing where directed at a level n exc. 1.5 mavove the starting point |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail