| 1 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out insoft/loose soil complete all as specified and directed. |
| 2 | Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc or for cess well cess pits man holes pier holes etc n.exc 10 sqm on plan n.exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed. |
| 3 | Excavation over areas n exc1.5 m deep and getting out in soft/losse soil complete all as specified anddirected. |
| 4 | Excavation over areas exc 1.5 m but n. exc 3 m deep and getting out in soft/losse soil complete all as specified anddirected. |
| 5 | Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate ) as in foundation, filling and mass concrete complete all as specified and directed. |
| 6 | Material and labour for moorum/ red bajri filling in floors or pavings including spreading levelling water and well ramming in layers not exc 15 cm thick complete all as specified and directed. |
| 7 | Materials and labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 8 | Material and labour for brick work with fly ash brick, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6)complete all as specified and directed. |
| 9 | Materials and labour for half brick thick brick work with fly ash bricks,old size, straight or curved on plan to any radius built in cement mortar(1:4) complete all as specified anddirected. |
| 10 | Material and labour for providing 40 mm thick damp proof course in cement concrete (1:2:4) type B-0 (using 12.50 mm graded stone aggregate) mixed with WPC @ 200 ml/ bag (50 Kg) of cement or as per manufacturers instruction to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.Note : WPC shall be included in the quoted rates of item. |
| 11 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 12 | Removing excavatedmaterial notexc 50 m and depositing where directed at a level not exc 1.5 m above the starting point as in soft/loose soilcomplete all as specified and directed. |
| 13 | Material and labourfor 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surface and finish the surfaceseven and smooth without using extra cement as in wall complete all as specified and directed. |
| 14 | Material and labour for 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) andfinish the surfaceseven and smooth without using extra cement as in wall complete all as specified and directed. |
| 15 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqmcomplete all as specified and directed. |
| 16 | Materials and labour for preparation of new plastered surfaces of walland applying three coat ofwhite wash complete all as specified and directed. |
| 17 | Supply and fix rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe 410 -W (Gde-E- 250) quality-A including one shop coat of red oxide zinc chrome primer complete all as specified and directed. |
| 18 | Supply and fix mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 19 | Material and labour for structural steel work in plates/ Base plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk)forming holes,without anyattachment conforming to Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed. |
| 20 | Supply and fix mild steel screw bolts diameter of neck 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n exc 5cm long complete all as specified and directed. |
| 21 | Supply and fix mild steel screw bolts diameter of neck 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.50cm and n exc 30cm long complete all as specified and directed.. |
| 22 | Supply and fix 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and directed. |
| 23 | Supply and fix 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and directed. |
| 24 | Material and labour for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 25 | Material and labour for 100mm thick PCC (1:4:8) type D-2 (using 40mmgraded stone aggregate) as in sub base of floor complete all as specified and directed. |
| 26 | Material and labour for 75mm thick PCC (1:2:4) type B-1 (using 20mmgraded stone aggregate) as in floor andfinish the surfaceseven and smooth without using extra cement complete all as specified and directed. |
| 27 | Material and labour forjoint free anti skid outdoor pavement coloured tiles (good grip series) of size 300 x 300 x 10mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 20mm thick screed bed in cement mortar (1:6) complete all as specified and directed. |
| 28 | Material and labour for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in plinth protection and finish theconcrete surface even and smooth without using extra cement complete all as specified and directed. |
| 29 | Material and labour for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade \"B\" complete all as specified and directed. |
| 30 | Material and labour for PCC (1:3:6) type C1 (using 20 mm graded stone aggregate ) as in surface channels, drains and manholes etc complete all as specified and directed. |
| 31 | Material and labour for mild steel TMT bar 10 mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 32 | All as per item No 31.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and .-ditto-. |
| 33 | Material and labour for reinforced cement concreteM-25 (Design Mix) (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 34 | Material and labour for reinforced cement concreteM-25 (Design Mix) (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 35 | Material and labour for reinforced cement concrete M-25 (Design Mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 36 | Material and labour for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished flat surfaces of concrete complete all as specified and directed. |
| 37 | Material and labour for form work to sides of pillars, posts, struts, piers, columns and stanchions with rough finished square, rectangular or polygonal surface of concrete complete all as specified and directed. |
| 38 | Material and labour for form work to sides and soffits of floor or roof beams, slab, girders, bres-summers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished flat surfaces of concrete complete all as specified and directed. |
| 39 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girthand applying two coats ofsynthetic enamel paint over a coat of red oxide zinch chrome primer complete all as specified and directed. |
| 40 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girthand applying one coat ofsynthetic enamel paint complete all as specified and directed. |
| 41 | Supply and fix 1mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 42 | Supply and fix MS Butt hinges heavy weight cold rolled 125mm sizecomplete all as specified and directed. |
| 43 | Suplly and fix 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not lessthan 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 44 | Supply and fix 125mm long mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed. |
| 45 | Supply and fix 150mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed. |
| 46 | Material and labour for precastcement concrete (1:2:4)type B0 (12.5 mm graded agregate) louvres and jallies, 25mm thick (measured solid), including all mould- ings set jointed and pointed in cement mortar (1:4) including necessary formwork complete all as specified and directed. |
| 47 | Supply and fix PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed . |
| 48 | Supply and fix expanded metal (weight not exc 4 Kg per sqm), cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel memberscomplete all as specified and directed. |
| 49 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 50 | Material and labour for light/fan point wiring (surface type) with single core PVCinsulated unsheathedmultistranded FR-LSH copper conductor cable of 1100 volts grade size 1.5 sqmm (nominal area) drawing in and including 20mm dia non metallic heavy dutyPVC conduit with all fittings including PVC board for housingswitches, sockets with fixing materials with one single core PVC insulated unsheathed multistranded FR-LSH copper conductor cable of 1100 volts grade size 1.5 sqmm (nominal area) as earth continuity wire and connected to earth dolly complete all as specified and directed.Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 51 | All as per item No. 50.00 here-in-before but for one five pins 5 Amps switch socket outlet point on independent board and -ditto-. |
| 52 | Supply and fix switch piano one way 5/6 amps240 volts, single polecomplete allas specified and directed. |
| 53 | Supply and fix switch socket combination 2 in 1,5 pin , 5 amps flush type complete allas specified and directed. |
| 54 | Material and labour for surface type sub-main wiring comprising single core , 2 runs of 4 sqmm nominal cross sectional area, FRLSHmultistranded copper conductor cable, PVC insulated unsheathed 1100 volts gradedrawing in and including appropriate dia of heavy duty non metalic PVC conduit and its fittings complete including provision of 1 run of 4 sqmm nominal cross sectional area, single coreFRLSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earthwirecomplete all as specified and directed.Note :-Extra length of cables/ wire required for connection to MCBs/DB\"s shall be included in quoted rate. |
| 55 | Supply and fix sheet metal enclosure SPN DB 4 ways double door having facility to fix SPN MCB in incomer and MCBs in outgoing, metal door IP-43 type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. |
| 56 | Supply and fix MCB SPN, 240 Volts, 40 amps, \"C\" series, breaking capacity 10 KA complete all as specified and directed. |
| 57 | Supply and fix MCB SP, 240 Volts, of 6 to 32 amps current rating, 10 KA breaking capacity \"C\" series complete all as specified and directed. |
| 58 | Material and labour for earthing complete with GI earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by 15 mm bore GI pipe (medium grade) including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 30 x 30 x5 cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion complete all as specified and directed.Note:- GI wire upto 7.5m length including testing shall be included in quoted rates. |
| 59 | Material and labour for earthing continuity conductor or main earthing lead fixed to wall or recess or chases with25 x 3.15 mm aluminium strip fixed on porcelin insulator at distance 100 cm interval complete all as specified and directed. |
| 60 | Material and labour for soldering/brazing tothe copper/aluminium strip joints in replacement of existing nuts bolts joints complete all as specified and directed. |
| 61 | Supply and fix air termination single pointed copper rod, 12mm dia and 300mm long including necessary fixing arrangment using clamps,nuts and boltscomplete all as specified and directed. |
| 62 | Material and labour for test point termination box made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos, 8 mm dia, 25mm long hexagonal heads screw for lighting conductors complete all as specified and directed. |
| 63 | Supply and fix thermoplastic enclosure box of size 300x150x170mm with opaque lid fasteners for tool operation protection of IP-66 for fixing of test point terminal box complete all as specified and directed. |
| 64 | Supply and fix next generation energy saving 100 Watt LED high bay light with pressure die cast housing integrated PC optics, IP 66 protection IK08, 5700K, 240 V, system efficacy upto 150 lumen/watt,impact resistivity a safety chain and surge protection minimum 5KV, suitable for suspended /surface mounting including control gear and suspension system complete all as specified and directed. |
| 65 | Supply installation, commissioning and testing of feeder pillar box (CPRI Approved) outdoor canopy type, floor mounted cubical type, dust and vermin proof made out of 3.15mm thick CRCA sheet of suitable size with 40mm x 40mm x 6mm MS angle section with hinged cubical doors with front and rear side openable with locking arrangement with powder coated paint over a coat of red oxide metal primer complete with and including provision of following accessories: -Incoming :- (a) MCCB rating 100 Amps, 4 pole breaking capacity 36 KA 415 volts with adjustable thermal and magnetic release type-01 No.(b) Copper busbar size of 200 Amps rating and fixed on 08 Nos porcelain insulator - 04 Nos. (c ) Indicator lamp LED (RYB) - 01 Set .(d) 3 Phase Digital Voltmeter - 01 No.(e) 3 Phase Digital ammeter - 01 No.Outgoing - (a) MCCB 32 Amps, 415 Volt, 16 KA with adjustable thermal and magnetic release type-03 Nos. |
| 66 | Materials and labour for steel tubular swaged poles, type-410, SP-31 (overall length 9.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coats of black bituminous paint throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, painting black & yellow alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified anddirected.Note: Excavation and earth work and PCC shall be measured and paid separately under respective items. |
| 67 | Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor)of size 120 Sqmm, 3.50 core, 1100 Volts, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified and directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. |
| 68 | Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor)of size 50 Sqmm, 3.50 core, 1100 Volts, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified and directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. |
| 69 | Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor)of size 16 Sqmm, 4 core, 1100 Volts, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified and directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. |
| 70 | Supply and fix PVC insulated multicore FR PVC sheathed 1.5 sqmm 3 core multistrand copper conductor for connection of security light from Junction Boxto security light complete all as specified and directed. |
| 71 | Supply and fix street light bracket made of 1.5 RM length of GI pipe of light grade of 40 mm dia in proper shaped, bend, threadedand drilling holes for wire entry and MS clamps made of 40x5mm (02 Nos) with nut & bolts of suitable size in proper shape cmplete all as specified and directed. |
| 72 | Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate ) as in foundation, filling and mass concrete complete all as specified and directed. |
| 73 | Material and labour for PCC (1:2:4), type B1, (using 20mm graded stone aggregate), as in coping of pole including necessaryformwork complete all as specified and directed. |
| 74 | Supply and fix loop in loop out junction box of size 300 x 200 x 105 mm made out of 1.6mm thick SMC sheet weather proof dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 04 nos aluminium bus bar of size 20 x 5 mm fixed on insulator and one MCB of capacity 10 Amp complete fixed on pole with and including suitable size MS flat iron clamp nut , bolt and washers of suitable size etc. complete all as specified and directed. |
| 75 | Material and labour for earthing complete with GI earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by 40 mm bore GI pipe (medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 30 x 30 x 5cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 15 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion complete all as specified and directed.Note:- GI strip upto 7.5m length including testing shall be included in quoted rates. |
| 76 | Supply and fix LED street light fittings of 120 Watt made of pressure die cast aluminium housing with toughened glass cover, IP66 protection, high power LEDs with secondary lenses and system efficacy should be minimum 120 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device and 10 KV surge protection device in luminare. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed. |
| 77 | Material and labour for sand cushioning with clean and dry river sand for protection of UG cable with approved sand of uniform thickness. laid dry, filling in trenches and punning down in proper required layers complete all as specified and directed. Note:- Punned down thickness shall be measured for payment. |
| 78 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified anddirected. |
| 79 | Supply and fix 25 mm dia HDPE pipe of pressure rating 6 kgf/cm2for passing of cable through PCC foundation from trench to cable junction box and also for protection of security light cable from junction box to light fitting with necessary clamp nuts and bolts complete all as specified and directed. |
| 80 | Material and labour for boring of holes horizontally under the road/pavemen/hard standing etc without disturbing top surface to cross the cable including material and labour for inserting GI pipe 50mm dia (meduim grade) complete all as specified and directed.Note-Necessary infrastructure required for boring shall by arranged by the contractor and cost of the same included in quoted rates. |