| 1 | Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etcandremoval of entire debris as ordered outside MD land complete all as directed. |
| 2 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick above or below ground level andremoval of entire debris as ordered outside MD land complete all as directed |
| 3 | Demolition of unreinforced cement concrete as in roofs, floors (other than ground floors), in any description of beams, staircases, landing, chaj-jas etc including removingof existingAPP membrane any thickness / Screed any thickness etc and removalofentiredebris as ordered outside MD land complete all as directed. |
| 4 | Demolition of reinforced cement concrete as in any description (reinforcement cut as required to facilitate demolition)including removing of debris as ordered outside MD land complete all as directed. |
| 5 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of debris to a distance not exceeding 50 mts and depositing where directed. |
| 6 | Dismantling of ACCorrugatedor semi corrugatedsheet etcanythicknessincluding ridges as in roof covering and stacking at site where directedand removal of debris to a outside MOD land and depositing where directed complete all as directed. |
| 7 | Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stackingserviceable tiles at site andremoval of entire debris as ordered outside MOD land complete all as directed. |
| 8 | Demolition of stone slabs and tiles of any description or thickness in floors, platform, aprons etc., laid, bedded and pointed in any mortar ,stackingserviceable slbs at site andremoval of entire debris as ordered outside MOD land complete all as directed. |
| 9 | Taking down chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from frame) and stacking at site where directed. |
| 10 | All as per item 6here-in-above but exceeding 1.5 Sqm but not exceeding 4 Sqm each |
| 11 | Taking down shutter of any description exceeding 1 Sqm but not exceeding 2 Sqm each and stacking at site where directed. |
| 12 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for in this Schedule all as directed |
| 13 | M&L for Separating, scraping and cleaning ofreinforcement (Demolition of concretemeasured Separately). |
| 14 | M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified. |
| 15 | All sameas per itemNo 14 here-in-above but solid blocks not exceeding 10 cm thick -do- |
| 16 | Cutting holes of size Exc. half brick but not exc. one brick in brick walls in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortarfor insertingholdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 TypeB-1 as required including making good as per its original specification with out any extra costcomplete all as directed. |
| 17 | S&F Second class hard wood factory made kiln - seasoned, plain, solid, straight chowkats and frames , wrought, framed, rebated on the solid, rounded or chamfered , put togetherwith glue, pinned at joints and fixed in position complete all as directed. |
| 18 | S&F 30 mm thick Flush shutters, solid core construction, with block coard core & plywood face panels commercial type on both side conforming to IS 2202 (Part- I) -1999, including internal liping beading all round fixed as in Door Shutter,Cup board shutter & Kitchen rack allas specified. |
| 19 | S&F solid PVC door frame of size 50X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification all as directed. |
| 20 | S&F Factory made solid panel pvc doorshutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing |
| 21 | S & F150 mm long aluminium, anodised , barrel tower bolt (ISI marked) of extruded section and fixed. |
| 22 | S&F 100mm size butt hinges, medium weight stainless steeland fixed . |
| 23 | S&F 150 mm size aluminium alloy handles (ISI Marked) cast type anodisedandmatt finishnot less than Gd AC 10 of IS: 1868 :1986 fixed. |
| 24 | S&F 300 mm long aluminium alloy, anodised sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed. |
| 25 | Supply and fixing aluminium anodised powder coatedtubular curtain rod 20 mm dia, fixed in required lengths complete all as specified and as directed |
| 26 | Supply and fixing decorative type brackets suitable forcurtain rod of 19 mm dia)projecting type fixed with brass chromium plated screws & PVC sleeves/rawl plug complete all as specified and as directed |
| 27 | S&F Floor door stopper 140 mm of aluminium alloy powder coated and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 28 | S&F Bands, straps, supports or stays for rainwater, hold fasts; wall ties; and similar small articles steel conforming to Fe-290 Gde-E-165. |
| 29 | Cutting/chipping the spalling concrete surfaces of columns, beams, facias, slabs, Chajjas & cartilevers etc., and trimming cleaning the surfaces of any thickness as ordered andapplying epoxy treatment for bonding old demolished concrete surfaces incl application of one coat of notozinc primer to the exposed reinforcement and over plastering in CM 1:4 average 20mm thick finishied even and smooth without using extra cement to level the surface etc incl necessary scafolding as required at site and where required complete all as specified and directed |
| 30 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. andbrushing thesamewith neat cement slurry with 3.0 Kg ofcement perSqm completeall asdirected. |
| 31 | M&L for 25 mm thick plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in floor and finished the surface suitable to receivefloor tilescomplete all as directed. |
| 32 | M & L non-skid coloured joint freeceramic tiles 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified. |
| 33 | All same as per item No 32here - in - above but each tile exceeding 0.18 Sqm butnotexceeding 0.36Sqm-do- |
| 34 | All same as per item No 32here - in - above but as in dado & skirting with10 mm thick 1 : 4 cement mortar screed - do - |
| 35 | M&L glazed ceramic coloured tiles of size 350x250x7 mm / 450x350x7 mm thick, on verticals surfaces, set and jointed inneat cement slurry including 10 mm thick back coat in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to matchcompleteall directed.(Note for item Nos 32 to 35 : i) Quoted rateis deemed to be inclusive of cement screed. ii) Colour of tiles shall be got appproved before incorporation in the work) |
| 36 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite , laid over andincluding15 mm thick screed bedding in cement mortar 1 : 6 all as specified & directed.(Note: Quoted rateis deemed to be inclusive of cement screed.) |
| 37 | M&L for rendering 15 mm thick in CM 1:6 on brick work or concrete surfacefinished the surface even and smooth without using extra cement complete all as specified. |
| 38 | M&L for rendering 5 mm thick in CM 1:3 onconcrete surface as in ceiling,chajja,roof projection etc. finished the surface even and smooth without using extra cement complete all as specified. |
| 39 | M&L Preparation of Old decorated surface and applying two coat of white wash on ceiling etc complete and as directed. |
| 40 | M&L for preparation of newly plastered surfaces of walls & applying three coats of white washon newly plastered surface of ceilings complete all as specified |
| 41 | M&L preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 1-2 mm thick wall care putty as ordered complete all as specified. |
| 42 | Complete removal of existing treatment and preparation of surface of wall ,washing,rubbing down and stopping of distempered and painted surface ,applying a coat of 1mm thick Birla wallcare putty for smooth finished of the surface and applying two coat of oil bound distemper all as specified and directed. |
| 43 | M & L Two coats of 1st quality synthetic enamel paint over a coat of pink primer on new wooden surface of any description over 10 cm in width or girth including necessary preparation of new wooden surface complete all as directed. |
| 44 | M&L Preparation of Old painted steel surfaceof any description and applying one coat of synthetic enamel paint over 10cm width or girth. |
| 45 | Taking down old rusted / wornout 15 mm bore GI tubing after necessary disconnection & S&F new 20 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed on walls/ceiling or laying in floors making necessary connection& testing on completion complete all as directed. |
| 46 | Taking down old rusted / wornout 20 mm bore GI tubing after necessary disconnection & S&F new 25 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed on walls/ceiling or laying in floors making necessary connection& testing on completion complete all as directed. |
| 47 | S&F in Repair CP Bib Tap Sink Cock wall mounted with150 mm long swivel spout & wall flangeall as directedby the Engineer -in -charge. |
| 48 | S&F in repairs 15mm Bib taps chromium plated fancy type cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for union.Make:Prayag 8306 or equivalent |
| 49 | S&F in repairs 2 in 1 CP 15mm Bib taps Quarter turn fancy typewith crutch or butterfly handle screwed down, screwed for iron pipe or for union. Make : Cera CL 2016 or equivalent |
| 50 | S&F in repairs Stop valve/Angle stop valve, 15 mm bore, cast copper alloychromium plated fancy type with long shank and cup concealed type. Make Cera F8040204 or its equivalent |
| 51 | S&F in repairs Brass chromiun platedtubular towel rail, 20mm dia ‘D’ type, 60CM long between flanges, fixed in repair. |
| 52 | S&F in repairsShower rose with brass chromium plated shower rose with or without swivel joints, 100mm size including fixing to steel pipe or union. Make: Cera Cat No-F7020304 or Equivalent |
| 53 | S & F in repairs chromium plated health faucet(ABS) with 1 metre long flexible pipe suitable for 15mm bore pipe complete all as specified and directed. |
| 54 | S&F in repairs CP Soap dish 150mm, fixed to wall with chromium plated brass screws |
| 55 | S & F Sheet glass shelf assembly consisting of 5.5mm thick shee glass shelf 12 cm wide with chromiumplated bracketguard and railing60 cm long all as specified and directed. |
| 56 | S & F glass corner shelf 8mm thick including CP railingradius 250mm complete all as specified and directed. |
| 57 | S&F towel ring of PTMT fixed with and including chromium platedbrass screws and wooden /plastic cleats(minimum weight 90 gms).washers |
| 58 | S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints fixed to wallin repars complete all as directed. |
| 59 | S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints fixed to wallin repars complete all as directed. |
| 60 | S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 61 | S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 62 | S&F 110 mm bore PVC (SWR) junction single (single ‘T’), equal or unequal with access door |
| 63 | S&F 75 mm bore PVC (SWR) junction single (single ‘T’), equal or unequal with access door |
| 64 | S&F 110mm bore PVC (SWR) branch piece, double (double ‘Y’) equal or unequal with access door |
| 65 | S&F 75mm bore PVC (SWR) branch piece, double (double ‘Y’) equal or unequal with access door |
| 66 | S&F in repair 75 mm size PVC (SWR) floor trap with grating including jonting the same with solvent cement complete all as directed. |
| 67 | S&F PVC (SWR) Vent cowl 110 mm bore size fixed complete all as directed. |
| 68 | S&F PVC (SWR) Vent cowl 75mm bore size fixed complete all as directed. |
| 69 | S&F in Repair Chromium Plated Steel Grating of 100mm size With or Without Waste Hole. |
| 70 | S&F 550 mm X 400 mm size white flat backvitreous china wash hand basin including chromium plated pillar tap cap stain head suitable for 15 mm bore of pipe , PVC connection 15 mm dia 45 cm long with chromium plated nuts and bolts and suitablewashers, PVC waste 32 bore CP waste coupling chain and plug , porcelain stopper including CI bracket fixed in repair complete all as diirected. |
| 71 | S&F in repairs 600mm x 450mm looking mirror of selected quality glass not less than 5mm thick, mounted on 6mm thick AC building board or commercial plywood including aluminium framing and fixed to PVC rawl plugs with chromium plated brass screws and cup washers complete all as specified. |
| 72 | S&F in repair sinksmade of stainless steel ( gde 304) 1mm thick kitchen or laboratory with CP waste coupling including ball and chain 300mm long with brass cap rubber plug, 32mm bore PVC waste pipe (heavy duty ) 90 cm long, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets & overall size (Approximate) 915mm x 460mmx203mm bowl size 410mm x 330mmx203mm Make :Nirali, Elegance(regular) Rangeequivelent ofPRAYAG /Diamond |
| 73 | &F in repairs stainless steel Kitchen plate rack of overall minimum size 900mm x 800mm and 250mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws all as directed.Note : Weight of rack shall not be less than 6.00 Kg. Make PRAYAG / equivelent of Nirali/Diamond/ Blue star / Parry ware |
| 74 | S&F in Repair Vitreous China Wash down water closet pan pedastel pattern (EWC) white in colour with and incl plastic water seat and cover white closed pattern with flat bottom and cover and MS chromium plated hinging device incl connection to outgoing pipe and flushing pipe complete all as specified & directed. |
| 75 | S&F in repairs 10 ltr capacity PVC Low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 600mm long etc complete. |
| 76 | E&M : Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing taken down materials to a place where ordered for crediting includingmaking good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed.. |
| 77 | Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalicconcealed conduit on stone/Brick Bldg conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thicklaminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :-(a) One light / Fan / bellpoint controlled by one 5 Amps switch one way |
| 78 | (d) One light point contrlled by one 5Amps withtwo way switchs , single pole |
| 79 | (b) One 3 pin socket point 5 Amp on independent board |
| 80 | (c) One 3 pin socket point 5 Amp on same board with other switches.(to be provide new point as user reqairment) |
| 81 | All as per item No. 77 here-in-above but with 2.5sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed. |
| 82 | Supply and fix Switch piano, flush button single pole, 5 Amps one way. |
| 83 | Supply and fix Switch piano, flush button single pole, 5 Amps two way. |
| 84 | Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose |
| 85 | Supply and fix Switch socket combination flush type 6/16 Amps 3/3 pin universal multipurpose |
| 86 | Supply and fix bell push, flush button single pole, 5 Amps one way. |
| 87 | Supply and fixDoor bell electronic, multi music type,230 volt AC. Make : Anchor/Havell/Polycab |
| 88 | Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC square blocks. |
| 89 | Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. |
| 90 | Taking down existinglight fittings fixed in any descriptionand S&F new 10 Watt , 6000K, 230 Volt,2ft Batten surface and wall mounted LED batten with aluminium extruded channel powder coated par glare free light with PVChousing & integrated electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete fixed as per manufacturers instructions and making necessary electricalconnections and testing on completion complete all as directed. . Make : Havells/wipro/surya/ Philips |
| 91 | Taking down existinglight fittings fixed in any descriptionand S&F new 20 Watt , 6000K, 230 Volt,4ft Batten surface and wall mounted LED batten withaluminium extruded channel powder coated par glare free light with PVC housing & integrated electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete fixed as per manufacturers instructions and making necessary electricalconnections and testing on completion complete all as directed. . Make : Havells/wipro/surya/ Philips |
| 92 | S&F in repairbldg security light light fittings 1x 35 Watt Ac 230v out door typeLED street light with high pressuredie cast aluminium and heat ressistent complete with driver ,lamp bracket with impact and corrosion resistentincluding thermal managment in multiple optics complete, IP65/66 and wired with all accessories and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size all as specified and directed. Make : Crompton Greaves/Bajaj/ Philips |
| 93 | S&F inrepair street light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flat iron clamp of size50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 94 | S&FSheet metal enclosure (ISI marked) distribution board for 240 volts, 8 Way SPN Vertical type, doubledoor, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed. |
| 95 | S&FSheet metal enclosure (ISI marked) distribution board for 415 volts, TPN 4 way Verticaltype, doubledoor, triple pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed. |
| 96 | S & F MCCB TPN100 Amps 415 volts, \"C\" Series 10 kA rupturing capacity providing in DB complete all as specified and directed by Engr-in-charge. |
| 97 | S & FMCB single pole 6 to 32 Amps 240 volts, 10 kA rupturing capacity providing in DB completewith all as specified and directed by Engr-in-charge. |
| 98 | S & F MCB single pole & neutral 40 Amps 240 volts, 10 kA rupturing capacity providing in DB completeall as specified. |
| 99 | Taking down old existing sub main wiring and provide new submain wiring with 2 runs of 6 Sqmm single core PVC insulated, unsheathed, multi strandedcopper conductor and one single core 6 Sqmm PVC insulated , unsheathed , multi strandedcopper cable as earthing lead as per IS : 694 / 1990 drawn through and includingnon-metallic PVC rigid conduit of size 20/ 25 mm diaconcealedin walls etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 6 Sqmm cable , one run6 Sqmmcableand one run of PVCshallbe measured as oneunit length) . |
| 100 | Takingdown any capacity & type ofwater geysers fixed in any description after necessary waterdisconnection & refixingthesame or different location as ordered after other B&Rrepair works are completed in all respectsincluding provn ofnew 600 mm long PVC connection pipe & pair ofPVC \"HOT\" & \"COLD\" connections , making necessarywater connection & testing on completion completeallas directed. |
| 101 | Taking down and Refixed any type and size of Exhaust fan in any description after making necessary connections & testing on completion and making good distrubed surfaces of wall, floors, etc complete all as directed. |
| 102 | Rewinding of Exhaust fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed . |
| 103 | M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thickburied directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 4 mm dia by means ofof nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified. |