| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone masonry built in CM including all quoins complete all as specified and directed. |
| 2 | Demolition of plain cement concrete (unreinforced) in ground floor and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 3 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and as directed. |
| 4 | Excavation in trenches in soft/loose soilnot exc.1.50 m wide and not exc.1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out complete all as specified and directed. |
| 5 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. |
| 6 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard/dense soil complete all as specified and directed. |
| 7 | M&L for hardcore of broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 8 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soft/loosesoil complete all as specified and directed. |
| 10 | Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. |
| 11 | M&L for RCC 1:2:4 nominal mix type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 12 | M&L for Plain Cement Concrete Type D-2, 1:4:8(using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 13 | M&L for precast cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate)blockmasonry with solid blocks exc 10cm in width and setting in CM 1:6 complete all as specified and directed. |
| 14 | M&L For Plain Cement concrete 1:3:6 type C-2 (Using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 15 | M&L for providing plain cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs other than for roof kerbs or mud stops, rounded or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 16 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate in forming channel, benching inside manholes (1/2 or 3/4 section) in manholes and as in coping including necessary form work complete all as specified and directed. |
| 17 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 18 | Extra for forming fair finished channel or drain of 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred stopped ends etc complete all as specified and directed. |
| 19 | M&L for Precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cover slab for manholes set in CM 1:4 including necessary form work complete all as specified and directed. |
| 20 | Cutting holes in brick walls built in CM for inserting hold fast and making good dismantled portion in CM 1:3 or PCC 1:2:4 (type B0) using 12.5 mm graded aggregate, depth of embedded portion of hold fast not exceeding half brick complete all as specified and directed. |
| 21 | M&L for brick work with sub class \"B\" bricks of old size, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed. |
| 22 | M&L for brick work with sub class \"B\" bricks of old size, straight or curved on plan to any radius built in CM 1:4 in half brick thick complete all as specified and directed. |
| 23 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, wall and similar work; not exceeding 200mm thick (Horizontal or sloping) for flat rough finished surface & concrete complete all as specified and as directed. |
| 24 | Taking down door chowkats or frames not exceeding 1.50 sqm with shutters (without taking off shutters from the frame) of any description complete all as specified and directed. |
| 25 | Taking down door chowkats or frames exceeding 1.50 sqm but not exceeding 4.00 sqmwith shutters (without taking off shutters from the frame) of any description complete all as specified and directed. |
| 26 | Taking down shutters of any description exc 1.00 Sqm and n.exc 2.00 Sqm, complete all as specified and directed. |
| 27 | M&L for taking down shutters of any description exc 2sqm each and refixing in the same opening complete all as specified and directed. |
| 28 | S&F 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint complete all as specified and directed. |
| 29 | S&F for 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 30 | M&L for 600 x 600mm false ceiling tiles (Gypsum board of decorative type) of 9mm thick with powder coatedmain tee of size 24 x 32 mm, having 0.27mm x0.25 mm gauge @ 1200mm c/c rotary stitched cross tee size of 24 x27 mm, gauge 27 mm and cross tee of size 24 x 27 mm having 0.25 mm gauge @ 1200 mm c/c and angle of size 19 x 19 mm gauge 0.35 mm fixed on periphery of wall and all above grids are suspended at every 1200 mm c/c in both direction by 2mm thick GI wire and all as per manufacture instructions complete all as specified and directed. |
| 31 | S&F providing PVC FALSE CEILING consisting of 600mm x 600mm, 5mm (±0.25) thick Plain embossedPVC sheetof Density 600 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company, used as panel insert in a frame work made using powder coated aluminum T- section of sizes 1” x1”( 25x25mm, 19 gauge or 1mm thick )in square pattern of grid sizes of 2’x2’( 600x600mm ). The aluminum framework is supported from the ceiling with the help of \"J\" hook and G.I. wire / 6mm M.S. rods of required sizes to maintain proper level etc. The aluminum framework is supported on side wall with the use of aluminum L-section of size 1”x1” ( 25x25mm) angles etc. complete all as specified and directed. |
| 32 | S&F Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm (+ -0.2mm), Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated), Corner striker, Secondary Strikers, Cylinder, Door transmission gear made of mild steel with multi point locking system with strikes, 3D Hinges of zinc alloyed (white powder coated) and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose) complete all as specified and as directed. |
| 33 | S&F Butt hinges of size 100mm extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed. |
| 34 | S&F for brass, sliding door bolt 250 mm long with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed. |
| 35 | S&F for brass, barrel tower bolt 150mm with cast or sheet barrel and of extruded section rolled or cast bolts and fixed complete all as specified and directed. |
| 36 | S&F for extruded brass handle 150mm fabricated type polished complete all as specified and directed. |
| 37 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor 150 mm size of cover plate complete all as specified and directed. |
| 38 | M&L for Door closer hydraulically regulated, aluminiumbody, designation No. 3 universal type, suitable for door shutters upto 851 to 1000 mm in width and of weight between 60 to 80 kg, ISI marked, complete all as specified and directed. |
| 39 | S&F Mortice lock, aluminium body, 4 lever, 150 mm size, vertical type with two keys complete all as specified and directed. |
| 40 | S&F Powder coated anodised aluminium frame with all fixing arrangements for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc aluminium section of powder coating not less than 50 micron complete all as specified and directed. |
| 41 | S&F Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats and locking arrangement, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete all as specified and directed.Note: Powder coating shall not be less than 50 micron. |
| 42 | S&F Powder coated Anodised aluminium door shutters, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, handles 2 nos in each door, hinges, anodised aluminium snap beading, complete all as specified and directed. Note: Powder coating shall not be less than 50 micron. |
| 43 | S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ annealing, C.P. brass/ stainless steel screws, complete all as specified and directed. |
| 44 | S&F mild steel framed worksuch as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 45 | S&F mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240, complete all as specified and directed. |
| 46 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and includingMS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 47 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws with necessary washers/welding complete all as specified and as directed. (The profile of the sheet as specified and directed). |
| 48 | S&F 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 49 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 50 | M & L for 100 mm thick cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) surface is to be finished smooth & even with using extra cement complete all as specified and directed. |
| 51 | M&L for Non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,in floors etc, laid in with 1.50mm spacer and grouted with epoxy joint filling material set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile including screed bed 15 mm thick in CM (1:6) complete all as specified directed. |
| 52 | M&L 40mm thick cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) in slab flooring, complete all as specified and directed. |
| 53 | M&L dark shade Vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm and n exc 1.00 Sqm, in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bed in CM 1:6, and pointed in coloured cement to match complete all as specified and as directed |
| 54 | M&L dark shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm and n exc 1.00 Sqm, set and jointed in neat cement slurry over and including 10 mm thick plaster in CM 1:4, and pointed in coloured cement to match in skirting etc complete all as specified and as directed. |
| 55 | Taking down cement plaster from brick or stone including raking out joints, hacking for keys, scrubbing down with water etc, wall of any description complete all as specified and directed. |
| 56 | M&L for 15mm thick cement plaster in CM 1:4 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on external wall complete all as specified and directed. |
| 57 | M&L 10mm thick cement plaster in CM 1:6 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on internal walls complete all as specified and directed. |
| 58 | M&L for 15mm thick cement plaster with water proofing compound in CM 1:4 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on external wall complete all as specified and directed. Note: Water proofing compound shall be measured separately. |
| 59 | M&L for 15mm thick cement plaster in CM 1:6 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on external wall complete all as specified and directed. |
| 60 | M&L for 20mm thick Granite (of any size) (table rubbed and polished) work in cooking platform, in steps, jambs, pillars, window-cills, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed or bedding layer of mortar 20 mm thick for laying floor tiles in cement mortar 1:4, complete all as specified and as directed. |
| 61 | M & L for Preparation of new plastered surfaces and applying two coats of white wash on wall surfaces complete all as specified and directed. |
| 62 | M&L for new wall surface applying waterproof cement based putty @ 300 Gm (undiluted) per Sqm of average thickness 1 mm over the putty surface with mechanical wall sander having mechanical vacuum mechanism with RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust and applying two coats of oil bound emulsion distemper over one coat of interior wall primer using airless spray technology with max two working pressure of 3300 PSI and capable of operating single spray gun with max material hose length of 30 m the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying oil emulsion should be able to spray in hard to reach area and penetration of oil emulsion on the surface etc. by skilled labour as per following steps complete all as specified and directed.(a) Mix the putty powder by adding water as per manufacturer instructions and mix with putty mixer with the mixing capacity of min 2.50 kg putty per minute.(b) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 litres per minutes with a maximum pressure 3300 PSI.(c ) Allow 6-8 hrs time to dry the putty surface. |
| 63 | M&L for new wall surface applyingtwo coats of cement base paint over one coat of wall primer using airless spray technology with max two working pressure of 3300 PSI and capable of operating single spray gun with max material hose length of 30 m the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to spray in hard to reach area and penetration of acrylic emulsion on the surface etc. by skilled labour as per manufacturer instructions complete all as specified and directed. |
| 64 | M&L for preparation of old decorated ceiling surface and applyingtwo coat ofOBD complete all as specified and directed. |
| 65 | Complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc by skilled labour and applying waterproof cement based putty @ 300 Gm (undiluted) per Sqm of average thickness 1 mm over the putty surface with mechanical wall sander having mechanical vacuum mechanism with RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust and applying two coats of interior acrylic emulsion paint over one coat of interior wall primer using airless spray technology with max two working pressure of 3300 PSI and capable of operating single spray gun with max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to spray in hard to reach area and penetration of acrylic emulsion on the surface etc. by skilled labour as per following steps complete all as specified and directed:-(a) Mix the putty powder by adding water as per manufacturer instructions and mix with putty mixer with the mixing capacity of min 2.50 kg putty per minute.(b) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI.(c ) Allow 6-8 hrs time to dry the putty surface. |
| 66 | S&F plain sheet glass ordinary quality 4mm thick as in doors, window, showcase aluminium frame work & similar work with or without glass roller area exc 0.50 Sqm including neoprene gasket complete all as specified and directed. |
| 67 | S&F 5.5mm sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed. |
| 68 | M&L for preparation of new steel surface of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer of red oxide zinc chrome complete all as specified and directed. |
| 69 | S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm including waste coupling of PTMT of 40mm dia(half or full threaded) (Minimum weight 60 gms) complete all as specified and as directed. |
| 70 | S&F GI tubing 15 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 71 | S&F GI tubing 20 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 72 | S&F 15 mm dia chromium plated bib taps (fancy type), cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete with check nut 15mm bore complete all as specified and as directed. |
| 73 | S&F GI pipe light grade of dia 40 mm with all fittings laid in trenches complete all as specified and as directed. |
| 74 | M&L for plain cement concrete 1:3:6 type C-2 (Using 40mm graded stone aggregate) for concrete bed to 200mm dia pipe including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 75 | M&L for 200mm internal dia RCC NP3 class pipe laid in trenches jointed with CM 1:1 and tested complete all as specified and directed. |
| 76 | M&L for cutting into existing manholes for 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 77 | Taking down existing unserviceable point wiring of any type/size of light/fan/socket/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area complete all as specified and directed. |
| 78 | Taking down existing unserviceable light fittings, security light fittings, bulk head fittings, fall ceiling light fittings etc. from any height of building complete all as specified and directed. |
| 79 | Taking down existing unserviceable Distribution boards with MCB\"s/MCCB\"s of any capacity complete all as specified and directed. |
| 80 | Taking down earthing material, plate and pipe etc from 2.25 mtrs depth complete all as specified and directed. |
| 81 | M&L for concealed Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade, ISI marked, 20 mm bore with conduit accessories for wiring concealed in wall, including provision of fabricated branded pressed steel terminal box concealed of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards/sockets/regulators of any size modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch.Note(1) The wiring shall be done in proper colour coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealed conduit including plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 82 | All as per Sl item No 81 above but for One ceiling fan/exhaust fan point controlled by one switch through modular regulator complete all as specified and as directed. |
| 83 | All as per Sl item No. 81 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent modular board complete all as specified and as directed. |
| 84 | All as per Sl item No. 81 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same modular board complete all as specified and as directed. |
| 85 | M&L for Point wiring complete with two runs of 4 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade, ISI marked, 20 mm bore with conduit accessories for wiring concealed in wall, including provision of fabricated branded pressed steel terminal box concealed of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards of any size modules for housing modular switches, sockets,etc and provn of 4 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one 15 Amps socket outpoint independent boardNote(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealed conduit including plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 86 | M&L for point wiring in PVC casing & capping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 4sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawl plug including 4sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles all as specified and directed for One light/bell/Fan point controlled by one, one way switch. |
| 87 | S&F Point wiring complete with 2.5 sqmm single core PVC insulated heavy duty ISI marked, unsheathed cable 1100 volts grade with multistranded copper conductor FRLS drawn through and including non metallic rigid PVC Conduit not less than 20mm dia and conduit accessories fixed to walls/floors/ceiling etc., and including provision of PVC insulated heavy duty copper conductor, 2.5 sqmm for earth continuity conductor and connected to common earth dolly, for 6 pin 6/16 Amps socket out controlled by 15 Amps switch complete all as specified and as directed. |
| 88 | S&F single pole Modular switch 1 way 6 Amps, 1 Module complete all as specified and as directedNote:(i)All light/fan switches shall besymbol embossed (light/fan) typecomplete all as specified and as directed.(ii) All switches for sockets shall be LED indicator type. |
| 89 | S&F single pole Modular switch 1 way 16 Amps, 1 Module with red LED indicator complete all as specified and as directed. |
| 90 | S&F Socket modular type multipurpose 2/3 Pin, 6 amps, 230 volts 2 Module complete all as specified and directed. |
| 91 | S&F Socket modular type multipurpose 3/6 Pin, 16 amps, 230 volts 2 Module complete all as specified and directed. |
| 92 | S&F Modular ceiling fan regulator stepped socket size, 2 module suitable to work on 230 volts complete all as specified and as directed |
| 93 | S&F ceiling rose three terminal surface bakelite type AC 50 Hz, 230 volts of size 65 x 50 mm complete all as specified and as directed |
| 94 | S&F MCB SP 6 to 32 Amps 240 volts C type with rupturing capacity 10 KA complete all as specified and as directed. |
| 95 | S&F MCB SPN 40 to 63 Amps 240 volts C type with rupturing capacity 10 KA complete all as specified and as directed. |
| 96 | S&F MCB TP, 40 to 63 Amps, rupturing capacity 10 KA 415 volts suitable for fixing in existing DB of any capacity complete all as specified and as directed. |
| 97 | S&F MCCB 415V, 16KA, 100 amps 4 Pole, thermal magnetic release fixed type, short circuit and over load protection suitable for DB complete all as specified and as directed. |
| 98 | S&F sheet metal enclosure MCB DB SPN 8 way double door with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed. |
| 99 | S&F of TPN DB 4 way double door vertical load line with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 100 Amps 16 KA, 4P made out of CRCA sheet housing duly powder coated and confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed. |
| 100 | S&F Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB of 32 A complete all as specified and as directed. |
| 101 | S&F MCB TPN, 100 Amps, rupturing capacity 10 KA, 415 volts suitable for fixing in existing DB of any capacity complete all as specified and as directed. |
| 102 | S&F of TPN DB 4 way double door horizontal made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed. |
| 103 | S&F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) complete all as specified and as directed. |
| 104 | S&F rigid PVC conduit of 20/30 mm diameter ISI marked complete all as specified and as directed. |
| 105 | S&F in repair MCB Single pole, 230 volts, 20 Amps, \"B\" Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed. |
| 106 | S&F Triple pole and Neutral enclosure with a two pin and earth plug and socket complete with one triple pole MCB (AC Box) complete all as specified and as directed. |
| 107 | S&F SPD 3 phase 4 pole Type 2 with pluggable model for each phase in 15 KA, I max total 50 KA complete all as specified and as directed. |
| 108 | M&L for fix in repair of PVC AC/ box with 20 Amp MCB DP, Socket and plug top, PVC, 3 Way complete all as specifeid and directed. |
| 109 | Cutting the existing road of suitable sizeincrossing and making good the disturbed surface of road to its original specification complete all as specified and directed. |
| 110 | Supply, laying and testing in trenches, LT underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 25 Sqmm, 4 core multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed. |
| 111 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed. |
| 112 | Supply and fixing cable routeindicator,made of MS sheet of size 200 mm x 150 mm x 3 mm thick,spot welded with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2 ( using 40mm graded crushed stone aggregate) block 30cm x 30cmx 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint and showing size of cable HT /LT complete all as specified and directed. |
| 113 | M&L Submain concealed wiring with 4 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metallic rigid PVC concealed conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulated sheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed.Note:-(1)The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2)The cost of cutting of chases of required width and depth for conduit including plastering, painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(3) The Five runs of copper wire, one run of PVC conduit shall be measured as one running meter. |
| 114 | M&L Submain concealed wiring with 2 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metallic rigid PVC concealed conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulated sheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed.Note:-(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2)The cost of cutting of chases of required width and depth for conduit including plastering , painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(3) The three runs of copper wire, one run of PVC conduit shall be measured as one running meter. |
| 115 | M&L for sub-main wiring with two runs of 4sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing capping of suitable size and fixing accessories should be concealed/fixed to wall/roof/floor and including suitable PVC casing capping with 4sqmm copper earth wire after taking out the existing sub-main wiring, making good to the disturbed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit/casing Capping will be measured as one length. Three run of 4Sq mm and PVC conduct/ Casing capping is measured as one Run or one Meter. |
| 116 | M&L for removing defective exhaust fan from the site, rewinding of the exhaust fan of any sweep upto 450mm complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer\"s design and instructions including varnishing complete including taking down, transportation, assembling back and refixing complete all as specified and directed. Note : 1.The items are to be removed from the site to be taken for rewinding from MES stores and returned to MES stores after necessary repair works. 2. The transportation for the same is inclusive of the rate quoted. |
| 117 | Taking out defective capacitor and supply and fix new capacitor of 4 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed. |
| 118 | M&L inrepairs of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate).Note:-(a)Earthing value should be less than 5 ohms.(b)If desired value of earth resistance not achieved during testing, the earthing work shall be redone by the contractor at free of cost to achieve the desire value of earthing resistance. The rate quoted by the contractor deemed to be inclusive of the provision. |
| 119 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 120 | S&F LED batten light fitting 20 Watts 4 feet surface / wall mounted aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and as directed. |
| 121 | M&L for light fitting with LED batten light fitting 20 Watts 4 feet surface / wall mounted aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. |
| 122 | S&F track mounted light 10 Watt with modern design, compact size with high power COB LED to provide focussed light with connector electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and as directed. |
| 123 | S&F track Light of length 2m with suitable accessories complete all as specified and directed. |
| 124 | S&F spot light8Watt with powder coated aluminium housing and pressure die-cast heat sink having high efficiency including c three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 125 | Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjustable power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with 5 Star rating as per BEE guidelines and ISEER Value 3.95 for air conditioner of capacity 2 TR complete all specified and directed. |
| 126 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1 TR complete all as specified and directed. |
| 127 | Supply, fixing, jointing and testing copper tubing with nominal diameter 1-1/8 inch of thickness not less than 1.2mm for liquid line to connect without door unit complete all as specified and directed. |
| 128 | Supply, fixing, jointing and testing copper tubing with nominal diameter 3/8 inch of minimum thickness not less than 0.9mm including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unit complete all as specified and directed. |
| 129 | M&L for fabrication of base stand made from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC including painting with two coats of metal paint over one coat synthetic enamelled black paint complete all as specified and directed. |
| 130 | S&F PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed. |
| 131 | S&F air curtain 4 ft long, 220-240 V, 50 Hz, RPM(Max/Min) 2700/2100, Body MS power coated, Nos of blowers-03 Nos of blowers-03, No of motors-02 Nos(single phase), Blower material-ABS, Noise level-50-70db, CFM-825, Max air velocity 21 m/s and with motion sensor complete all as specified and as directed. |
| 132 | S&F Modular metal flush terminal boxes with lumina plate and frame suitable for 1 module complete all as specified and as directed. |
| 133 | S&F Modular metal flush terminal boxes with lumina plate and frame suitable for 2 module complete all as specified and as directed. |
| 134 | Supply & fix Special standing seam fixture Clamp for Air terminal on Metal Structure -Site specific complete all as specified and directed. |
| 135 | Supply & fix Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol, 3 mtr mast complete all as specified and directed. |
| 136 | Supply & fix 8mm dia solid Aluminium Conductor for Down Conductor and tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 complete all as specified and directed. |
| 137 | Supply & fix Aluminium conductor holding clamp suitable for fixing 8 mm Down Conductor, Conductor holder @ 1 meter distance should be tested as per IEC-62561-2 conditioning & Ageing test, conducted in the Govt. accredited third party laboratory to meet the requirement of IS/ IEC 62305 complete all as specified and directed. |
| 138 | Supply & fix Standing Seam clamp to hold 8 mm Al conductor at every 1m distance on the top roof without any drilling on roof, Installation can be made through simple fastening system, mainly used for seaming sheet roof application tested as per IEC-62561-2 for conditioning & Ageing test & conducted in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 62305 complete all as specified and directed. |
| 139 | Supply & fix Cross splicer should be tested for conditioning, Ageing Test & Lightening impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol complete all as specified and directed. |
| 140 | Supply & fix Aluminium Straight Splicers for 8mm and 10mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol complete all as specified and directed. |
| 141 | Supply & fix Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305 complete all as specified and directed. |
| 142 | Supply & fix test link in order to disconnect the earth termination system for enabling measurements. SS Test Link To connect Round to Flat conductor complete all as specified and directed. |
| 143 | Material and Labour for maintenance free comprising of 17.2 mm dia 3 mtr long Earth electrode of low carbon steel electrode with 250 micron copper bonding, 50 pounds of Ecosafe based environment friendly backfill and suitable clamp, back-fill earthing enhancing compound should strictly be a Eco Safe carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (like in metals) and should not depend on moisture for conduction. Back-fill compound should be environment friendly, should solidify when mixed water and set like concrete and should not leach/diffuse into the ground.Back-fill compound shall not mix with any soil while pouring in the bore hole.Test Certificate as per IEC :62561-7 for Back-fill compound shall be submitted along with the material.17.2 OD SS clamp both side, Eco friendly rust proof heavy duty weather proof Polyethylene Earth pit chamber with following dimensions: 254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). |
| 144 | Supply and Installation of 10 mm copper bonded Round steel solid Conductor for ring earthing meet the requirements of IS/IEC 62305 and IEC 6256-2, Type B earthing has been proposed for complete buildings complete all as specified and directed. |
| 145 | Supply and fix PVC insulated multistrand copper conductor 25.0 sqmm wire all as specified and directed. |
| 146 | M&L for test terminal block made out of gun metal or phosphorus bronze 75mmx75mmx25mm with accessories complete all as specified and directed. |
| 147 | S&F danger notice plate made of high quality material (screwed down plastic, copper label or threaded label) inscribed with \"Earthing lead - Do not disconnect\" including durable, legible, fade resistant letters and securely fixed with appropriate fastners and mounting accessories complete all as specified and directed.Note for Item No.143 to 147: (i) Earthing value should be constant for 15 years from the date of installation. Certification for the same to be obtained by the contractor from OEM and submitted to Engr In Charge before completion of work. (ii) In case the value are not found within limit ie less than 1 Ohm of Equipments, less than 5 for LA and power supply the same to be rectified by the contractor free of cost for 15 years.(iii) The following test certificate shall be submitted to Engineer In charge prior to supply of material : (a) Certificate for copper bonded electrode alongwith control number duly certified by CPRI, Short circuit withstanding capacity of the copper bonded rod from an independent laboratory (NABL accredited Laboratory). (iv) Resistivity test certificate for the backfill compound from an independent laboratory (NABL accredited laboratory) (v) Contractor has to install the earthing in ring system in order to obtain desired value as mentioned in Ser No II of Note.(vi) Rate quoted by the contractor for earthing deemed to inclusive of cost of Exothermic joints and cost for ring formation etc. nothing extra will be paid to the contractor.(vii) Make for Item No. 134 to 147 : Rail Tech Engg Works, Hyderabad/ MCML Bangalore/ JEF Techno Switches Pvt Ltd/ Thirumala /True Power Ltd. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail